• 제목/요약/키워드: Hybrid power system

검색결과 1,312건 처리시간 0.027초

가스터빈/연료전지 혼합발전 시스템의 열교환기 설계 (Design of the recuperator for the gas turbine/fuel cell hybrid power generating system)

  • 곽재수;양수석;이대성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2105-2110
    • /
    • 2004
  • Plate-fin type recuperators for the gas turbine/fuel cell hybrid power generating system were designed using commercial design software, MUSE. Heat transfer efficiency and total pressure drop in the recuperator were calculated to confirm required recuperator performance. Both counter flow and cross flow type plate-fin recuperators were designed. Results show that the counter flow type has higher efficiency and short core length, but the cross flow type is simpler to construct because the cross flow type does not need additional distributors. Two or three headers for the each recuperator core will be designed and tested to evaluate best header design. The designed recuperators and headers which will be designed later will be constructed, tested, and used in gas turbine/fuel cell hybrid power generating system.

  • PDF

스마트 제어를 이용한 하이브리드 형 제어장치 연구 (A Study on Hybrid Control Unit Using a Smart Control)

  • 김희철
    • 한국전자통신학회논문지
    • /
    • 제11권11호
    • /
    • pp.1093-1100
    • /
    • 2016
  • 본 연구는 슈퍼캐패시티 EDLC(:Electric double layer capacitor)를 적용한 가로등용 태양광-풍력 하이브리드 발전시스템 성능의 우수함과 안정성을 입증하고자 한다. 독립전원용 태양광-풍력 하이브리드 발전시스템의 부하로 LED 광원을 이용한 조명장치를 적용하고 고출력 발전시스템을 통한 가로등 시스템 장치의 개발을 목표로 하고 있다. 발전된 전력을 배터리에 저장하는데 있어서 보조장치로 적용될 EDLC는 기존의 컨트롤러와는 달리 배터리의 고출력과 긴 수명을 보장할 수 있어 기존장치에 비해 유지보수가 적게 들고 우수한 성능을 확보할 수 있다.

Design of the Electronic Anti-Fouling System for a Wave Energy Converter

  • Lee, Ji-Young;Oh, Jin-Seok
    • 한국항해항만학회지
    • /
    • 제33권7호
    • /
    • pp.501-504
    • /
    • 2009
  • There are many difficulties to supply constant power to marine facilities which operate in the sea. Especially, there is a limit to stand alone power supply systems due to the influence of weather conditions. That's why a hybrid power supply system is required to overcome these problems. This paper will describe an Electronic Anti-Fouling System (EAFS) to maximise the power efficiency for a solar - wave hybrid power generation system. A main factor reducing the efficiency of a Wave Energy Converter (WEC) is due to the attachment of aquatic life forms. Therefore the aim of this research is to develop a simulation programme to enable the design of more efficient EAFS for hybrid power generation systems and to provide valuable data for production of more efficient EAFS.

ESS 기능을 갖는 하이브리드 UPS (Hybrid UPS with Energy Storage System Function)

  • 임승범;홍순찬
    • 전력전자학회논문지
    • /
    • 제19권3호
    • /
    • pp.266-275
    • /
    • 2014
  • This paper proposes the hybrid UPS(Uninterruptible Power Supply) with ESS(Energy Storage System) function. The proposed hybrid UPS is operating in four states, which are normal state, battery state, ESS state, and bypass state. In case of peak load time or power shortage, the system is operating in ESS state in which the stored energy of the battery is used to manage the power effectively. The validity of proposed system are verified by simulations and experiments.

하이브리드 광 추적방식의 태양광 발전 시스템 (Solar Power Generation System with Hybrid Sun Tracker)

  • 이재민;김용
    • 한국산업융합학회 논문집
    • /
    • 제13권2호
    • /
    • pp.69-75
    • /
    • 2010
  • This paper describes the design and implementation of hybrid sun tracking solar power generation system designed by combining astronomical data with optical tracking mechanism. The advantages of proposed power generation system are small amounts of calculation for tracking operations and enhancement of 40% of power generation at best. This system is able to track toward optimal position for maximum sun-lights under scattered lights due to clouds. The performance of implemented power generation system is confirmed by field experiments.

  • PDF

태양광 배터리 Hybrid 전력공급시스템 9가지 운전 모드 시험결과 및 무고장 연속 운전을 위한 자동제어 알고리즘 개발 (Experimental Test Results of Nine Scheduling Operational Modes of PV and Battery Hybrid System for the Development of Automatic Control Algorithm for Continual Operation without being shut-downed)

  • 송택호;양승권;김민정
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권1호
    • /
    • pp.25-32
    • /
    • 2019
  • K-BEMS 시스템은 태양광과 배터리를 Hybrid PCS 및 EMS로 구성하여, 건물에너지 절감 및 건물 PEAK 부하를 감축하기 위해 도입되었으며, 200여 한전 사옥에 보급되어 시범 운영되고 있다. K-BEMS 시스템을 보다 안정적으로 그리고 효율적으로 운영하기 위한 K-BEMS 연구과제를 2016년 1월부터 2018년 현재까지 전력연구원이 약 3년간 걸쳐 수행하였다. 본 논문에서는 K-BEMS 연구과제에서 수행한 9가지 Scheduling 운전 모드 시험 결과 및 3년간의 Scheduling 운전 결과 발견한 문제점, 그리고 이 문제점 해결을 위해 도입한 제어 알고리즘을 보여 주고 있다. K-BEMS 9가지 Scheduling 자동제어 운전모드 시험을 수행 하였으며, 이 중 3가지 운전모드에서 알고리즘 개선 사항을 발견하였는데, 이들 3가지 경우 모두 배터리 연계 운전과 관련이 있는 것으로 드러났다. 배터리 SOC(State of Charge)는 통상 20% 이상에서 운전되는데, 20% 이하가 되면 배터리 보호 차단기가 동작하여 K-BEMS 자동 운전이 정지되는 현상을 발생한다. 그런데 이 Hybrid 자동제어 모드에서, 배터리 차단기 trip시 태양광 공급마저 중단되는 현상을 발견하였다. 그러므로, Hybrid 공급모드에서 배터리의 차단기가 동작될 경우, 태양광 단독운전으로 자동 전환하여 태양광 공급마저 중단되지 않도록 알고리즘을 재구성하여 자동제어 운전하는 것이 총 에너지 절감 측면에서 반드시 필요한 것으로 분석되었다. 이 때, 계측제어 오차를 감안하여야 하며, 배터리 정지를 너무 보수적으로 의식하여, SOC 운전 Range를 너무 축소해서 운전하면 당초의 피크 부하 저감 이라는 경제성 목표를 달성할 수 없으므로, 효과적인 hybrid 운전(건물 피크 부하 감축 운전)을 위해서는 정지된 SOC 값을 컴퓨터가 기억하고 있다가, 향후 재가동 자동제어 운전시에서는 SOC Range값을 변경 조정 하여 최적 제어 운전하는 자동제어 알고리즘이 PV & Battery hybrid peak load demand control에서 반드시 필요한 것으로 나타났다.

태양열 화학반응 복합발전시스템의 설계 및 시공 사례 (Design and Construction Experiences of Solar Thermal Chemical Reaction Hybrid Power Generation)

  • 이상남;강용혁;김진수;윤환기;유창균;김종규
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.688-692
    • /
    • 2007
  • Solar thermal power generation allows additional benefits of cheap thermal storage and easy hybridization with other fossil fuel-driven power generation. KIER has been performing the project for solar thermal chemical reaction hybrid power generation. The project is to build and operate the first solar thermal chemical reaction hybrid power generation system in Korea. For concentrating solar thermal energy $m^2$ dish type concentrator was adapted and a heliostat is installed for reflecting horizontal insolation to the dish concentrator. At the moment building the dish concentrator including mirror and heliostat with sun tracking system was completed and it's performance are being closely evaluated. This paper will introduce some detailed designs and construction procedures which we have experienced so far.

  • PDF

독립형 풍력기반 Smart Microgrid 시스템의 현장 실증 시험을 위한 도서지역 전력 및 경제성 시뮬레이션 (Power and Economic Simulation of Island for the Field Demonstration Test of Smart Microgrid System Based on Stand-alone Wind power)

  • 강상균;이은규;이장호
    • 신재생에너지
    • /
    • 제10권3호
    • /
    • pp.22-30
    • /
    • 2014
  • The isolated self-generating electricity with diesel engine generator has been used in islands far away from main land. It costs high because of increasing oil price, and unsafe to have supplying oil and its related components by ship due to unexpectable marine conditions. Therefore there is the need for the hybrid system of renewable energy like wind or solar energy systems with oil engine generator, which can reduce oil use and extend oil supplying period. In this study, the feasibility of such hybrid system with smart micro grid on the eight islands of Jeon-nam province is surveyed to find good place for the demonstration test of the hybrid system. In each island, 3 wind turbine systems of 10 kW and photovoltaic of 20 kW are tested with already installed diesel engine. The performance and costs of the hybrid system in each island are compared in the given conditions of solar and wind energy potential. As a result of the study, Jung-ma island is recommended for the optimum place to make real field demonstration test of isolated hybrid generating and smart grid systems.

Power Quality Control of Hybrid Wind Power Systems using Robust Tracking Controller

  • Ko, Heesang;Yang, Su-Hyung;Lee, Young Il;Boo, Chang-Jin;Lee, Kwang Y.;Kim, Ho-Chan
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.688-698
    • /
    • 2015
  • This paper presents a modeling and a controller design for a hybrid wind turbine generator, especially with an operating mode of battery energy-storage system and a dumpload that contribute to the frequency control of the system while diesel-synchronous unit is not in operation. The proposed control scheme is based on a robust tracking controller, which takes an account of system uncertainties due to the wind flow and load variations. In order to provide robustness for system uncertainties, the range of operation is partitioned into three operating conditions as sub-models in the controller design. In the simulation study, the proposed robust tracking controller (RTC) is compared with the conventional proportional-integral (PI) controller. Simulation results show that the effectiveness of the RTC against disturbances caused by wind speed and load variation. Thus, better quality of the hybrid wind power system is achieved.

Modeling of Solar/Hydrogen/DEGS Hybrid System for Stand Alone Applications of a Large Store

  • Hong, Won-Pyo
    • 조명전기설비학회논문지
    • /
    • 제27권11호
    • /
    • pp.57-68
    • /
    • 2013
  • The market for distributed power generation based on renewable energy is increasing, particularly for standalone mini-grid applications in developing countries with limited energy resources. Stand-alone power systems (SAPS) are of special interest combined with renewable energy design in areas not connected to the electric grid. Traditionally, such systems have been powered by diesel engine generator sets (DEGS), but also hybrid systems with photovoltaic and/or wind energy conversion systems (WECS) are becoming quite common nowadays. Hybrid energy systems can now be used to generate energy consumed in remote areas and stand-alone microgrids. This paper describes the design, simulation and feasibility study of a hybrid energy system for a stand-alone power system. A simulated model is developed to investigate the design and performance of stand-alone hydrogen renewable energy systems. The analysis presented here is based on transient system simulation program (TRNSYS) with realistic ventilation load of a large store. Design of a hybrid energy system is site specific and depends on the resources available and the load demand.