• 제목/요약/키워드: Hybrid heating

검색결과 196건 처리시간 0.023초

Fabrication and Micropatterning of a Hybrid Composite of Amorphous Calcium Carbonate and Poly(ethylenimine)

  • Lee, Hyun-Sook;Ha, Tai-Hwan;Kim, Hyun-Min;Kim, Kwan
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권3호
    • /
    • pp.457-462
    • /
    • 2007
  • Amorphous calcium carbonate (ACC) can readily be prepared using ethanol as the reaction medium and ammonium carbonate as the source of carbon dioxide. Other additives, or any elaborate pH control are not needed to form the initial calcium carbonate precipitate. Ammonia generated from ammonium carbonate maintains the reaction medium in a neutral or weakly basic condition, retarding the crystallization of ACC, while ethanol itself inhibits the dissolution of ACC. The ACC prepared in this way provides a rare opportunity to fabricate molded biomimetic crystals in vitro, but the ACC is too fragile to be fabricated into proper shapes. The malleability of ACC is, however, greatly enhanced by incorporating poly(ethylenimine) (PEI). The ACC/PEI composite can then be fabricated, using a proper mold or template, into mechanically durable biomimetic crystals of definite shape. The ACC in the ACC/PEI composite can further be transformed into vaterite by heating under N2 atmosphere, while the native ACC simply converts into calcite.

주거용 태양열 하이브리드 이산화탄소 열펌프 시스템의 성능특성에 관한 해석적 연구 (Simulation Study on the Performance Characteristics in the Solar Hybrid R744 Heat Pump for Residential Applications)

  • 김원석;조홍현
    • 설비공학논문집
    • /
    • 제23권10호
    • /
    • pp.678-686
    • /
    • 2011
  • Simulation study on the operating characteristics in the solar hybrid R744 heat pump system for residential applications was carried out with heat pump operating temperature, outdoor temperature and solar radiation. As a result, collector operating time is decreased by 1.5 hours due to the increase of water temperature in the heat storage tank when the heat pump operating temperature rises. Heat pump operating time is reduced by 19.4% owing to the high temperature of a heat storage tank. Besides, indoor heating time is decreased from 10.3 to 5.5 hours as the indoor temperature increases from $3^{\circ}C$ to $11^{\circ}C$. In addition to, when the solar radiation rises from 10 to 20 MJ/$m^2$, the maximum outlet temperature of a solar collector is increased from $65^{\circ}C$ to $71^{\circ}C$.

Dual Mode Phase-Shifted ZVS-PWM Series Load Resonant High-Frequency Inverter for Induction Heating Super Heated Steamer

  • Hisayuki Sugimura;Hidekazu Muraoka;Tarek Ahmed;Srawouth Chandhaket;Eiji Hiraki;Mutsuo Nakaoka;Lee, Hyun-Woo
    • Journal of Power Electronics
    • /
    • 제4권3호
    • /
    • pp.138-151
    • /
    • 2004
  • In this paper, a constant frequency phase shifting PWM-controlled voltage source full bridge-type series load resonant high-frequency inverter using the $4^{th}$ generation IGBT power modules is presented for innovative consumer electromagnetic induction heating applications, such as a hot water producer, steamer and super heated steamer. The bridge arm side link passive capacitive snubbers in parallel with each power semiconductor device and AC load side linked active edge inductive snubber-assisted series load resonant tank soft switching inverter with a constant frequency phase shifted PWM control scheme is evaluated and discussed on the basis of the simulation and experimental results. It is proved from a practical point of view that the series load resonant and edge resonant hybrid high-frequency inverter topology, what is called, DE class type, including the variable-power variable-frequency regulation function can expand zero voltage soft switching commutation area even under low output power setting ranges, which is more suitable and acceptable for newly developed induction heated dual pack fluid heaters. Furthermore, even the lower output power regulation mode of this high-frequency load resonant tank inverter circuit is verified so that this inverter can achieve ZVS with the aid of the single auxiliary inductor snubber.

샘플링 기반 민감도를 이용한 국부 유도 가열용 코일의 최적 설계 (Optimal Design of Local Induction Heating Coils Based on the Sampling-Based Sensitivity)

  • 최낙선;김동욱;김동훈
    • 한국자기학회지
    • /
    • 제23권3호
    • /
    • pp.110-116
    • /
    • 2013
  • 본 논문에서는 전자기 결합 문제에 대한 효율적인 최적 설계를 위하여 샘플링 기반 민감도법을 제시하였다. 전자기 해석과 열/구조 해석 사이의 결합 특성에 무관하게 최적해를 도출하기 위하여 블랙박스 개념에 기초한 설계기법이 적용되었다. 현 설계점을 중심으로 초입방체 국부 영역에서 크리깅 근사모델을 생성하고 근사모델의 기저함수의 미분을 통하여 설계민감도 값을 도출하였다. 제안된 설계기법은 샘플링 기반 설계기법과 민감도 기반 설계기법의 장점만을 취한 혼합형 설계기법으로 열/구조 특성과 강성 결합된 전자기 문제의 최적 설계에도 적용이 가능하다. 제안된 방법은 비선형성이 강한 수학 예제 및 과도상태 해석이 요구되는 국부 유도가열용 코일 설계에 적용하여 그 정확성과 타당성을 검증하였다.

저에너지주택의 지열히트펌프시스템 냉·난방 성능분석 (Heating and Cooling Performance Analysis of Ground Source Heat Pump System in Low Energy House)

  • 백남춘;김성범;신우철
    • 설비공학논문집
    • /
    • 제28권10호
    • /
    • pp.387-393
    • /
    • 2016
  • A ground source heat pump system maintains a constant efficiency due to its stable heat source and radiant heat temperature which provide a more effective thermal performance than that of the air source heat pump system. As an eco-friendly renewable energy source, it can reduce electric power and carbon dioxide. In this study, we analyzed one year of data from a web based remote monitoring system to estimate the thermal performance of GSHP with the capacity of 3RT, which is installed in a low energy house located in Daejeon, Korea. This GSHP system is a hybrid system connected to a solar hot water system. Cold and hot water stored in a buffer tank is supplied to six ceiling cassette type fan coil units and a floor panel heating system installed in each room. The results are as follows. First, the GSHP system was operated for ten minutes intermittently in summer in order to decrease the heat load caused by super-insulation. Second, the energy consumption in winter where the system was operated throughout the entire day was 7.5 times higher than that in summer. Moreover, the annual COP of the heating and cooling system was 4.1 in summer and 4.2 in winter, showing little difference. Third, the outlet temperature of the ground heat exchanger in winter decreased from $13^{\circ}C$ in November to $9^{\circ}C$ in February, while that in summer increased from $14^{\circ}C$ to $17^{\circ}C$ showing that the temperature change in winter is greater than that in summer.

폴리비닐 부티랄에 붙힌 지르코늄 알콕시드 졸을 사용한 전기방사에서 지르코니아 나노섬유 제조와 광발광 (Photoluminescence and Fabrication of Zirconia Nanofibers from Electrospinning an Alkoxide Sol Templated on a Polyvinyl Butyral)

  • 고태경;한규석;임태균;오성규;한상환
    • 한국세라믹학회지
    • /
    • 제47권4호
    • /
    • pp.343-352
    • /
    • 2010
  • A zirconia gel/polymer hybrid nanofiber was produced in a nonwoven fabric mode by electrospinning a sol derived from hydrolysis of zirconium butoxide with a polyvinyl butyral. Results indicated that the hydroxyl groups on the vinyl alcohol units in the backbone of the polymer were involved in the hydrolysis as well as grafting the hydrolyzed zirconium butoxide. In addition, use of acetic acid as a catalyst resulted in further hydrolysis and condensation in the sol, which led to the growth of -Zr-O-Zr- networks among the polymer chains. These networks gradually transformed into a crystalline zirconia structure upon heating. The as-spun fiber was smooth but partially wrinkled on the surface. The average fiber diameter was $690{\pm}110\;nm$. The fiber exhibited a strong but broad blue photoluminescence with its maximum intensity at a wavelength of ~410 nm at room temperature. When the fiber was heat-treated at $400^{\circ}C$, the fiber diameter shrunk to $250{\pm}60\;nm$. Nanocrystals which belonged to a tetragonal zirconia phase and were ~5 nm in size appeared. A strong white photoluminescence was observed in this fiber. This suggests that oxygen or carbon defects associated with the formation of the nanocrystals play a role in generating the photoluminescence. Further heating to $800^{\circ}C$ resulted in a monoclinic phase beginning to form In the heat-treated fibers, coloring occurred but varied depending on the heating temperature. Crystallization, coloring, and phase transition to the monoclinic structure influenced the photoluminescence. At $600^{\circ}C$, the fiber appeared to be fully crystallized to a tetragonal zirconia phase.

마그네트론 스퍼터링 법을 이용한 IZO/Ag/IZO 다층 박막 투명 면상 발열체 (IZO/Ag/IZO Multilayers Prepared by Magnetron Sputtering for Flexible Transparent Film Heaters)

  • 박소원;강동령;김나영;황성훈;전승훈;;김태훈;김서한;박철우;송풍근
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.114.2-114.2
    • /
    • 2017
  • Transparent film heaters (TFHs) based on Joule heating are currently an active research area. However, TFHs based on an indium tin oxide (ITO) monolayer have a number of problems. For example, heating is concentrated in part of the device. Also, heating efficiency is low because it has high sheet resistance ($R_S$). Resistance of indium zinc oxide (IZO) is similar to ITO and it can be used to flexible applications due to its amorphous structure. To solve these problems, our study introduced hybrid layers of IZO/Ag/IZO deposited by magnetron sputtering, and the electrical, optical, and thermal properties were estimated for various thickness of the metal interlayer. It was found that the sheet resistance of the multilayer was mainly dependent on the thickness of the Ag layers. The $R_S$ of IZO(40)/Ag/IZO(40nm) multilayer was 5.33, 3.29, $2.15{\Omega}/{\Box}$ for Ag thickness of 10, 15, and 20nm, respectively, while the $R_S$ of an IZO monolayer(95nm) was $59.58{\Omega}/{\Box}$. The optical transmittance at 550nm for the IZO(95nm) monolayer is 81.6%, and for the IZO(40)/Ag/IZO(40nm) multilayers with Ag thickness 10, 15 and 20nm, is for 72.8, 78.6, and 63.9%, respectively. The defrost test showed that the film with the lowest RS had the highest heat generation rate (HGR) for the same applied voltage. The results indicated that IZO(40)/Ag(15)/IZO(40nm) multilayer has the best suitable property, which is a promising thin film heater for the application in vehicle windshield.

  • PDF

태양열과 지열을 이용한 난방용 공기순환시스템 기초연구 - 태양열을 이용한 트롬월식의 축열성능 중심으로 - (A Basic Study on the Air Circulation System for Heating using Solar and Geothermal Heat - Focused on Trombe Wall Thermal Storage Performance using Solar Heat -)

  • 김병윤;최용석
    • 한국농촌건축학회논문집
    • /
    • 제19권4호
    • /
    • pp.49-56
    • /
    • 2017
  • Each country in the world currently concentrates on shifting into clean energy, which can be alternative energy, for global environment protection and solution to the problem of fossil fuel depletion. The Korean government is predicted to develop renewable energy, such as solar power, ground power, and offshore wind power, and to increase their supply ratios by ending the use of coals and nuclear power plants. This study conducted experiments on thermal storage performance of Trombe wall thermal storage materials using solar power and simulations in order to offer baseline data for the development of a hybrid air circulation system for heating that can maximize efficiency by simultaneously using solar and geothermal power. The study results are as follows: (1) In all the specimens with 3m, 5m, and 7m in the length of thermal storage pipe, $5.7^{\circ}C$, $7.8^{\circ}C$, and $10.5^{\circ}C$ rose, respectively, as the thermal storage effect of the specimens attaching insulation film and black tape to the general funnel. They were most excellent in terms of thermal storage effect. (2) As a result of thermal performance evaluation on the II type specimens, II-3 ($7.8^{\circ}C$ rise) > II-4 ($5.3^{\circ}C$ rise) > II-1 ($3.9^{\circ}C$ rise) > II-2 ($2.3^{\circ}C$ rise) was revealed, and thus II-3 (insulation film + black tape) was most effective as shown in the I type. (3) This study analyzed air current and temperature distribution inside of the greenhouse by linking actually measured values and simulation interpretation results through the interpretation of CFD (computational fluid dynamics). As a result, the parts absorbing heat and discharging heat around the thermal storage pipe could be visibly classified, and temperature distribution inside of the greenhouse around the thermal storage pipe could be figured out.

A Novel Induction Heating Type Super Heated Vapor Steamer using Dual Mode Phase Shifted PWM Soft Switching High Frequency Inverter

  • Sugimura, Hisayuki;Eid, Ahmad;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.774-777
    • /
    • 2005
  • In this paper, a constant frequency phase shifting PWM controlled voltage source full bridge-type series load resonant high-frequency inverter using the IGBT power modules is presented for innovative consumer electromagnetic induction heating applications such as a hot water producer, steamer and super heated steamer. The full bridge arm side link passive quasi-resonant capacitor snubbers in parallel with the each power semiconductor device and high frequency AC load side linked active edge inductive snubber-assisted series load resonant tank soft switching inverter with a constant frequency phase shifted PWM control scheme is discussed and evaluated on the basis of the simulation and experimental results. It is proved from a practical point of view that the series load resonant and edge resonant hybrid high-frequency soft switching PWM inverter topology, what is called class DE type. including the variable-power variable-frequency(VPVF) regulation function can expand zero voltage soft switching commutation range even under low output power setting ranges, which is more suitable and acceptable for induction heated dual packs fluid heater developed newly for consumer power utilizations. Furthermore, even in the lower output power regulation mode of this high-frequency load resonant tank high frequency inverter circuit it is verified that this inverter can achieve ZVS with the aid of the single auxiliary inductor snubber.

  • PDF

구역전기 사업시 CHP와 신재생에너지 하이브리드 시스템의 최적공정 모델 (Optimization Process Models of CHP and Renewable Energy Hybrid Systems in CES)

  • 이승준;김래현
    • 에너지공학
    • /
    • 제26권2호
    • /
    • pp.99-120
    • /
    • 2017
  • 한국지역난방공사 SS지사에서는 시설용량 전기 99MW, 열 98Gcal/h 규모의 열병합(Combined Heat & Power) 발전소를 구역전기사업으로 운영하고 있다. 이 지역은 경기불황과 수요감소로 하절기 6~9월 사이에 잉여열 처리문제가 발생하여 발전기를 가동하기 곤란한 상황이므로 경제성 있는 에너지 신사업모델 개발이 절실하다. 본 연구에서는 이곳의 실제 운영자료를 기반으로 신재생 에너지 하이브리드 시스템을 도입하여 최적화 운영모델을 개발하고자 한다. 특히 신재생에너지 중에서도 입지제약이 작고 열과 전기를 동시에 생산할 수 있는 연료전지(Fuel Cell)발전과 대표적인 신재생에너지인 태양광(Photovoltaic)발전과 심야발전시 전력을 저장하여 주간에 전력을 방출 할 수 있는 ESS(Energy Storage System)의 조합을 검토하였다. 이에 따른 최적화 모델 선정은 HOMER(Hybrid Optimization of Multiple Energy Resources) 프로그램을 활용하였다. 경제성 분석을 수행한 결과, 순 현재비용(NPC) 측면에서는 기존의 99MW 열병합발전이 가장 경제적이지만 신재생에너지를 사용하여 발생되는 탄소배출권 거래와 REC(Renewable Energy Certificate) 거래를 포함한 측면에서는 99MW의 CHP와 5MW의 연료전지, 521kW의 태양광을 하이브리드 시켜서 전력과 열을 공급하는 것이 99MW의 CHP 열병합발전만으로 전력과 열을 공급하는 것보다 최대 2,475억원 경제적인 것으로 나타났다. 구역전기사업에서 최적화 공정모델로 연료전지와 신재생에너지 하이브리드 시스템을 도입함으로써 경제성을 개선시킬 수 있는 결과를 확인하였다.