• Title/Summary/Keyword: Hybrid device

Search Result 612, Processing Time 0.029 seconds

Evaluation of the repair capacities and color stabilities of a resin nanoceramic and hybrid CAD/CAM blocks

  • Bahadir, Hasibe Sevilay;Bayraktar, Yusuf
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.140-149
    • /
    • 2020
  • PURPOSE. This study evaluated the color stabilities of two computer-aided design and computer-aided manufacturing (CAD/CAM) blocks and a nanofill composite resin and the microtensile bond strength (µTBS) between the materials. MATERIALS AND METHODS. Twelve specimens of 4 mm height were prepared for both Lava Ultimate (L) and Vita Enamic (E) CAD/CAM blocks. Half of the specimens were thermocycled (10,000 cycle, 5° to 55℃) for each material. Both thermocycled and non-thermocycled specimens were surface treated with one of the three different methods (Er,Cr:YSGG laser, bur, or control). For each surface treatment group, one of the thermocycled and one of non-thermocycled specimens were restored using silane (Ceramic Primer II), universal adhesive (Single Bond Universal), and nanofill composite resin of 4-mm height (Filtek Ultimate). The other specimens were restored with the same procedure without using silane. For each group, 1 × 1 × 8 mm bar specimens were prepared using a microcutting device. Bar specimens were thermocycled (10,000 cycle, 5° to 55℃) and microtensile tests were performed. Staining of the materials in coffee solution was also compared using a spectrophotometer. Data were analyzed using one-way ANOVA, t-test and post-hoc Scheffe tests. RESULTS. µTBS were found similar between the thermocycled and non-thermocycled groups (P>.05). The highest µTBS (20.818 MPa) was found in the non-thermocycled, bur-ground, silane-applied E group. Silane increased µTBS at some E groups (P<.05). Composite resin specimens showed more staining than CAD/CAM blocks (P<.05). CONCLUSION. CAD/CAM blocks can be repaired with composite resins after proper surface treatments. Using silane is recommended in repair process. Color differences may be shown between CAD/CAM blocks and the nanofill composite after a certain time period.

Performance Evaluation of Attention-inattetion Classifiers using Non-linear Recurrence Pattern and Spectrum Analysis (비선형 반복 패턴과 스펙트럼 분석을 이용한 집중-비집중 분류기의 성능 평가)

  • Lee, Jee-Eun;Yoo, Sun-Kook;Lee, Byung-Chae
    • Science of Emotion and Sensibility
    • /
    • v.16 no.3
    • /
    • pp.409-416
    • /
    • 2013
  • Attention is one of important cognitive functions in human affecting on the selectional concentration of relevant events and ignorance of irrelevant events. The discrimination of attentional and inattentional status is the first step to manage human's attentional capability using computer assisted device. In this paper, we newly combine the non-linear recurrence pattern analysis and spectrum analysis to effectively extract features(total number of 13) from the electroencephalographic signal used in the input to classifiers. The performance of diverse types of attention-inattention classifiers, including supporting vector machine, back-propagation algorithm, linear discrimination, gradient decent, and logistic regression classifiers were evaluated. Among them, the support vector machine classifier shows the best performance with the classification accuracy of 81 %. The use of spectral band feature set alone(accuracy of 76 %) shows better performance than that of non-linear recurrence pattern feature set alone(accuracy of 67 %). The support vector machine classifier with hybrid combination of non-linear and spectral analysis can be used in later designing attention-related devices.

  • PDF

Simultaneous Measurement of External Refractive Index and Temperature by Using a Side-polished Fiber Bragg Grating with a Polymer Overlay (폴리머 코팅된 측면 연마 단주기 격자 기반 외부 굴절률 및 온도 동시 측정 센서 연구)

  • Kim, Hyun-Joo;Jun, Na-Ram;Lee, Sang-Bae;Han, Young-Geun
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.5
    • /
    • pp.190-194
    • /
    • 2010
  • A hybrid grating sensing device based on a side-polished fiber Bragg grating (FBG) with a polymer overlay is proposed for simultaneous measurement of external refractive index and temperature. The side-polished FBG, which is insensitive to ambient index change, is utilized for detecting temperature variation, and the polymer overlay is coated on the side-polished FBG for measurement of ambient index change. The temperature sensitivities of the side-polished FBG and the polymer overlay were measured to be 0.01 nm/$^{\circ}C$ and -0.58 nm/$^{\circ}C$, respectively, in a temperature range from $30^{\circ}C$ to $100^{\circ}C$. The ambient index sensitivities of the polymer overlay were measured to be 498.8 nm/RIU in an ambient index range from 1.33 to 1.39, 694.9 nm/RIU from 1.39 to 1.42, and 1312 nm/RIU from 1.42 to 1.44.

Layout Based Multimodal Contents Aughoring Tool for Digilog Book (디지로그 북을 위한 레이아웃 기반 다감각 콘텐츠 저작 도구)

  • Park, Jong-Hee;Woo, Woon-Tack
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.512-515
    • /
    • 2009
  • In this paper, we propose layout based multimodal contents authoring tool for Digilog Book. In authoring step, users create a virtual area using mouse or pen-type device and select property of the area repetitively. After finishing authoring step, system recognizes printed page number and generate page layout including areas and property information. Page layout is represented as a scene graph and stored as XML format. Digilog Book viewer loads stored page layout and analyze properties then augment virtual contents or execute functions based on area. Users can author visual and auditory contents easily by using hybrid interface. In AR environment, system provides area templates in order to help creating area. In addition, proposed authoring tool separates page recognition module from page tracking module. So, it is possible to author many pages using only single marker. As a result of experiment, we showed proposed authoring tool has reasonable performance time in AR environment. We expect that proposed authoring tool would be applicable to many fields such as education and publication.

  • PDF

Clinical Experiences of MIDCAB - Developmental Stage and Early Short-term Results - (최소침습적 관상동맥우회술의 발전단계와 경험에 대한 고찰)

  • 이영탁;정철현
    • Journal of Chest Surgery
    • /
    • v.32 no.11
    • /
    • pp.1009-1016
    • /
    • 1999
  • Background: Minimally invasive direct coronary artery bypass surgery(MIDCAB) has been increasing in interest along with the new techniques in myocardial immobilization for easier and safer procedures. Until the opening of the era of new techniques, adequate accuracy and good patency of grafts were debatable. Our experiences of MIDCAB were studied according to the stages of technical developments. Material and Methods: Since March 1996, 55 patients have undergone MIDCAB procedures. The patients of off-pump CABG(no cardiopulmonary bypass under full sternotomy) were excluded from the study. In the early experience(Stage I), a left anterior small thoracotomy through the left parasternal incision was performed(n=6); then an approach through the lower partial sternotomy was used(Stage II, n=33); and recently, a chest wall elevator for harvesting the internal thoracic artery and the foot plate for myocardial immobilization have been used(USSC, Norwalk, CT)(Stage III, n=16). Result: The surgical procedures of four patients in the Stage II group have been converted to conventional bypass because of the deeply seated left anterior descending coronary artery in two patients, fracture of the calcific lesion in the right coronary artery in one patient, and a cardiogenic shock during hypothermia in the other patient with ventricular dysfunction. Two patients in stage II experienced symptomatic recurrences after surgery and restenosis was verified on angiocardiography. They were managed by interventional procedures. All the other patients were doing well without symptoms, except one patients in Stage II who underwent PTCA procedure for a lesion in the circumflex artery during the follow up period. Conclusion: The new and specialized devices are essential to the development of MIDCAB surgery. MIDCAB and the hybrid procedures in multi-vessel disease are on the way to further development. So far, our experience is limited only to a single device among the many new devices for the purpose.

  • PDF

Frequency Multiplier Using Diplexer based on CRLH Transmission Line (CRLH 전송선로를 기반으로 한 다이플렉서를 이용한 주파수 체배기)

  • Kim, Seung-Hwan;Kim, Young;Lee, Young-Soon;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.1
    • /
    • pp.66-73
    • /
    • 2010
  • This paper proposes the frequency multiplier using diplexer based on CRLH transmission line with dualband characteristic. The diplexer is separated the output signals of harmonic generator, which is generated the harmonic signals using nonlinear device. The diplexer consists of the inphase power divider, 0o/90o phase controller and dual-band quadrature hybrid coupler. This send out the selecting output signals of the harmonic signals and suppresses out of signals. To validate a function of multiplier, the harmonic generator and diplexer with 2 GHz and 3 GHz operating frequency range is implemented. As a result, the proposed frequency multiplier is operated normally.

Dual Mode Phase-Shifted ZVS-PWM Series Load Resonant High-Frequency Inverter for Induction Heating Super Heated Steamer

  • Hisayuki Sugimura;Hidekazu Muraoka;Tarek Ahmed;Srawouth Chandhaket;Eiji Hiraki;Mutsuo Nakaoka;Lee, Hyun-Woo
    • Journal of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.138-151
    • /
    • 2004
  • In this paper, a constant frequency phase shifting PWM-controlled voltage source full bridge-type series load resonant high-frequency inverter using the $4^{th}$ generation IGBT power modules is presented for innovative consumer electromagnetic induction heating applications, such as a hot water producer, steamer and super heated steamer. The bridge arm side link passive capacitive snubbers in parallel with each power semiconductor device and AC load side linked active edge inductive snubber-assisted series load resonant tank soft switching inverter with a constant frequency phase shifted PWM control scheme is evaluated and discussed on the basis of the simulation and experimental results. It is proved from a practical point of view that the series load resonant and edge resonant hybrid high-frequency inverter topology, what is called, DE class type, including the variable-power variable-frequency regulation function can expand zero voltage soft switching commutation area even under low output power setting ranges, which is more suitable and acceptable for newly developed induction heated dual pack fluid heaters. Furthermore, even the lower output power regulation mode of this high-frequency load resonant tank inverter circuit is verified so that this inverter can achieve ZVS with the aid of the single auxiliary inductor snubber.

Metal Grids Embedded Transparent Conductive Electrode with Flexibility and Its Applications

  • Jung, Sunghoon;Lee, Seunghun;Kim, Jong-Kuk;Kang, Jae-Wook;Kim, Do-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.314-314
    • /
    • 2013
  • Recently, flexibility is one of the hottest issues in the field of electronic devices. For flexible displays or solar cells, a development of transparent conductive electrodes (TCEs) with flexibility, bendability and foldability is an essential element. Hundreds of nanometers indium-tin-oxide (ITO) films have been widely used and commercialized as a transparent electrode, but their brittleness make them difficulty to apply flexible electronics. Many researchers have been studying for flexible TCEs such as a few layers of graphene sheets, carbon nanotube networks, conductive polymer films and combinations among them. Although gained flexibility, their transmittance and resistivity have not reached those of commercialized ITO films. Metal grids electrode cannot act as TCEs only, but they can be used to lower the resistance of TCEs with few losses of transmittance. However, the possibility of device shortage will be rise at the devices with metal grids because a surface flatness of TCEs may be deteriorated when metal grids are introduced using conventional methods. In our research, we have developed hybrid TCEs, which combined tens of nanometers ITO film and metal grids which are embedded in flexible substrate. They show $13{\Omega}$/${\Box}f$ sheet resistance with 94% of transmittance. Moreover, the sheet resistance was maintained up to 1 mm of bending radius. Also, we have verified that flexible organic light emitting diodes and organic solar cells with the TCEs showed similar performances compared to commercial ITO (on glass substrate) devices.

  • PDF

A Comparison of Anterior Cervical Discectomy and Fusion versus Fusion Combined with Artificial Disc Replacement for Treating 3-Level Cervical Spondylotic Disease

  • Jang, Seo-Ryang;Lee, Sang-Bok;Cho, Kyoung-Suok
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.6
    • /
    • pp.676-683
    • /
    • 2017
  • Objective : The purpose of this study is to evaluate the efficacy and safety of 3-level hybrid surgery (HS), which combines fusion and cervical disc replacement (CDR), compared to 3-level fusionin patient with cervical spondylosis involving 3 levels. Methods : Patients in the anterior cervical discectomy and fusion (ACDF) group (n=30) underwent 3-level fusion and the HS group (n=19) underwent combined surgery with fusion and CDR. Clinical outcomes were evaluated using the visual analogue scale for the arm, the neck disability index (NDI), Odom criteria and postoperative complications. The cervical range of motion (ROM), fusion rate and adjacent segments degeneration were assessed with radiographs. Results : Significant improvements in arm pain relief and functional outcome were observed in ACDF and HS group. The NDI in the HS group showed better improvement 6 months after surgery than that of the ACDF group. The ACDF group had a lower fusion rate, higher incidence of device related complications and radiological changes in adjacent segments compared with the HS group. The better recovery of cervical ROM was observed in HS group. However, that of the ACDF group was significantly decreased and did not recover. Conclusion : The HS group was better than the ACDF group in terms of NDI, cervical ROM, fusion rate, incidence of postoperative complications and adjacent segment degeneration.

Biomineralization on Polydiacetylene Patterns Deposited by Using a Novel Mini Arrayer (신규 미니어레이어에 의한 폴리다이아세틸렌 패턴상의 생체유도결정화)

  • Lee, Won Doc;Lee, Gil Sun;Ahn, Dong June
    • Korean Chemical Engineering Research
    • /
    • v.48 no.3
    • /
    • pp.350-354
    • /
    • 2010
  • In natural world various inorganic crystals are grown with controlled shape and size in hybrid forms with organics. Such natural processes have been attempted much to mimick artificially. One of the example is calcium carbonate which has been examined a lot in the field of biomineralization. In this study, we utilize well-organized surface of polydiacetylene(PDA) films as the crystal-growing template. We devised a novel mini-arrayer device that transfers PDA films at air/water interfaces of each array well and deposit them to hydrophobized glass substrates. This technical improvement will contribute to facilitate better understandings of biomineralization mechanism.