• Title/Summary/Keyword: Hybrid crown

Search Result 49, Processing Time 0.032 seconds

Hybrid telescopic double crown denture on maxillary few remaining teeth and 2 mandibular implants in case of failed implant overdenture (상악의 소수 잔존치와 실패한 하악의 임플란트 오버덴처의 재수복 임상증례: 프릭션핀을 이용한 하이브리드 텔레스코픽 이중관법)

  • Ha, Seok-Joon;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.246-252
    • /
    • 2016
  • Double crown prostheses can be used in patients who have a few remaining teeth and poor periodontal condition because of secondary splinting of abutments, vertical loading, decrease of the length of lever arm due to fulcrum line located on margin of inner and outer crown. Successful results of treatments using double crown prostheses for the partially edentulous patients who have a few remaining teeth and implant overdenture using a small number of implants have been reported. In this case, there were a few remaining teeth with a very poor periodontal condition in maxilla, and there were a failed implant with severe alveolar bone resorption and shrinkage in the mandible. The main objective of this report is to introduce our case because a double crown partial denture showed satisfactory results in functional and esthetical aspects during more than one-year follow-up period.

Differential Response to Growth Regulator of Tobacco Crown Gall Tumor and Genetic Tumor (연초 Crown Gall Tumor 와 Genetic Tumor의 식물호르몬에 대한 분화반응)

  • 양덕춘;정재훈;민병훈;최광태;이정명
    • Korean Journal of Plant Tissue Culture
    • /
    • v.26 no.1
    • /
    • pp.31-35
    • /
    • 1999
  • Morphological characteristic during formation of tobacco crown gall tumor and genetic tumor, and their differential response to growth regulator were investigated in in vitro culture. Crown gall tumor was induced from tumor tissue transformed by infecting Agrobacterium tumefaciens C58. Genetic tumor was induced from tumor tissue which was induced spontaneously from reciprocal interspecific hybrids between Nicotiana glauca (2n=24) and Nicotiana langsdorffii (2n=18). Morphological characteristic of crown gall tumor, genetic tumor, and teratoma shoot was very similar, and they were actively proliferated on hormone-free medium. Typical tumor callus and teratoma shoot formed from crown gall tumor on the hormone-free medium. On the contrary, tumor callus derived from genetic tumor formed as a crown gall tumor callus on the medium supplemented with 0.5 mg/L of 2,4-D, and lots of teratoma shoots without any root formed on the hormone-free medium. Root development from the teratoma shoots was hardly obtained on the medium with IAA, GA and active carbon. However, teratoma shoots with roots, as normal shoots, were initiated occasionally on the hormone-free medium. These shoots also formed new genetic tumor on the stem, which leaves formed lots of teratoma shoot on the hormone-free medium in in vitro culture.

  • PDF

Solvent-free Microwave-Assisted Ortho-Alkylation of Aromatic Ketimine with Acrylic Acid Derivatives by Rh(I) Catalyst

  • Jo, Eun-Ae;Ahn, Jeong-Ae;Jun, Chul-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.11
    • /
    • pp.2020-2024
    • /
    • 2007
  • The article reports the synthesis of a novel bispyridino-18-crown-6 ether, 7-{[(5S,15S)-5,15-diphenyl- 3,6,14,17-tetraoxa-23,24-diazatricyclo[17.3.1.18,12]tetracosa-1(23),8(24),9,11,19,21-hexaen-10-yl]oxy}heptylferrocenamide 6, bearing the C2-symmetric diphenyl substituents as chiral barriers and the ferrocenyl groups serving as an electrochemical sensor, and its electrochemical study with D- and L-AlaOMe·HCl as the guest by cyclovoltametry.

Perception of maxillary anterior esthetics by dental professionals and lay people and topographical tooth-gingiva interface (한국인의 상악 전치부 심미 인지 선호도 및 정상 치은의 형태 분포)

  • An, Ki-Yeon;Lee, Ju-Youn;Kim, Sung-Jo;Choi, Jeom-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.4
    • /
    • pp.817-827
    • /
    • 2006
  • Purpose : This study was designed 1) to compare the perception of dental professionals and lay people with respect to minor variations in maxillary anterior tooth size and alignment and their relation to the surrounding soft tissues, and 2) to evaluate the normal tooth-gingiva topographical relationships in periodontally healthy young subjects, Materials and methods : Maxillary anterior teeth were intentionally diagrammed in varying degree of deviation with respect to one of three common anterior esthetic discrepancies including variations in crown length, shape of gingival margin, and length of interproximal contact, 17 images were generated to be preferentially selected by 2 groups consisting of dental professionals and lay people (total of 740). Smiling photographs of 120 dental students who had healthy periodontium were taken and the photographic images were analyzed to be classified as 17 kinds of altered image groups. Results : The results demonstrated noticeable difference between the varying levels of discrepancy. Both group preferred gingival margin of lateral incisor to be 0.5mm lower than that of central incisor. Lay people preferred the gingival margin shape that has 2/9 horizontal component of the crown width, while dental professionals preferred the gingival margin shape that has 1/9 horizontal component of the crown width. Lay people preferred longer length of the interproximal contact (two thirds of the crown length), whereas dental professionals preferred shorter length of the interproximal contact (half of the crown length). Photographic analysis of normal esthetic gingival topography revealed 2/9 horizontal component and short length of the interproximal contact which was of the hybrid nature of the preferences shared by lay people and dental professionals. Conclusion: The results of this study show that dental professionals and lay people demonstrated significant difference in their preference of dental esthetic components, which may then influence the decision making process by dental professionals with respect to designing the anterior esthetic gingival line.

Periodontal prosthesis on medically compromised patient with few remaining teeth: hybrid telescopic double crown with friction pin method (의과적 문제가 있고 소수 잔존치를 가지는 환자에서의 치주보철 임상증례: 프릭션핀을 이용한 하이브리드 텔레스코픽 이중관법)

  • Ha, Seok-Joon;Lee, Cheong-Hee;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.359-365
    • /
    • 2014
  • Successful results of treatments using double crown prostheses for the partially edentulous patients who have a few remaining teeth have been reported in several journals. A double crown removable partial denture can be an alternative treatment for the patients with a poor periodontal condition of remaining teeth. Since a double crown removable partial denture can be applied without the risk of surgical operation to the medically compromised patients with a poor periodontal condition which is inadequate for dental implants, it has psychological and economical advantages. In this case, there were sufficient remaining teeth to be restored with fixed prostheses in maxilla, while there were a few remaining teeth with a very poor periodontal condition so that it was almost impossible to restore with a clasp removable partial denture using these remaining teeth in mandible. In addition, the patient had the medical history of surgical operation due to osteomyelitis in the mandibular anterior areas a year ago, thus difficult to conduct an implant placement. The main objective of this report is to introduce our case because a double crown partial denture using a few mandibular remaining teeth showed satisfactory results in functional and esthetical aspects during more than two years follow-up period in this unfavorable condition.

DEVELOPMENT OF INVERTER AND POWER CAPACITORS FOR MILD HYBRID VEHICLE (MHV) - TOYOTA "CROWN"

  • Shida, Y.;Kanda, M.;Ohta, K.;Furuta, S.;Ishii, J.
    • International Journal of Automotive Technology
    • /
    • v.4 no.1
    • /
    • pp.41-45
    • /
    • 2003
  • The 42V Mild Hybrid System has been released into market by Toyota for the first time in the world in 2001. The set-up employs an inverter unit to control the motor/generator (MG) electronically. The driving system called such as Toyota Mild Hybrid System (TMHS) has additional new functions to conventional internal combustion engines. When stopping vehicle, the engine stops promptly. When starting vehicle, by releasing the brake pedal MG starts the vehicle at the same time (EV-driving mode). When stepping on the accelerator pedal, or after a given period of time the engine firing occurs and the engine-driving mode starts. When running by motor, the power is supplied to the motor from 36V battery through the inverter. High outputs and instant responses are required for Inverter. At the same time, the compact volume is required to fit into the limited space of the engine room. The compact size and high output are also required to Power Capacitor used for this inverter. The power capacitors has been newly developed, shaped in "flat" type, suitably for the inverter. The points of developments on inverter and power capacitor are described in this paper.his paper.

Study on Root Sucker of the Hybrid F1 Populus alba×P. glandulosa for the Use as a Fuel Wood and Erosion Control Species (산복피복을 (山腹被覆) 위한 현사시 근맹아력의 (根萌芽力) 시험(試驗) 및 이의 이용(利用))

  • Noh, Eui Rae
    • Journal of Korean Society of Forest Science
    • /
    • v.57 no.1
    • /
    • pp.26-31
    • /
    • 1982
  • The hybrid poplar, populus alba ${\times}$ P.glandulosa $F_1$ shows a strong ability to produce root suckers. The relationship between crown density and root sucker was studied and the other factors that may be related to production of root sucker were also discussed. The possibility was also discussed to use its root suckers for fuelwood forests and vegetation in the area that erosion control is needed.

  • PDF

Fracture resistance of implant- supported monolithic crowns cemented to zirconia hybrid-abutments: zirconia-based crowns vs. lithium disilicate crowns

  • Elshiyab, Shareen H;Nawafleh, Noor;Ochsner, Andreas;George, Roy
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2018
  • PURPOSE. The aim of this in vitro study was to investigate the fracture resistance under chewing simulation of implant-supported posterior restorations (crowns cemented to hybrid-abutments) made of different all-ceramic materials. MATERIALS AND METHODS. Monolithic zirconia (MZr) and monolithic lithium disilicate (MLD) crowns for mandibular first molar were fabricated using computer-aided design/computer-aided manufacturing technology and then cemented to zirconia hybrid-abutments (Ti-based). Each group was divided into two subgroups (n=10): (A) control group, crowns were subjected to single load to fracture; (B) test group, crowns underwent chewing simulation using multiple loads for 1.2 million cycles at 1.2 Hz with simultaneous thermocycling between $5^{\circ}C$ and $55^{\circ}C$. Data was statistically analyzed with one-way ANOVA and a Post-Hoc test. RESULTS. All tested crowns survived chewing simulation resulting in 100% survival rate. However, wear facets were observed on all the crowns at the occlusal contact point. Fracture load of monolithic lithium disilicate crowns was statistically significantly lower than that of monolithic zirconia crowns. Also, fracture load was significantly reduced in both of the all-ceramic materials after exposure to chewing simulation and thermocycling. Crowns of all test groups exhibited cohesive fracture within the monolithic crown structure only, and no abutment fractures or screw loosening were observed. CONCLUSION. When supported by implants, monolithic zirconia restorations cemented to hybrid abutments withstand masticatory forces. Also, fatigue loading accompanied by simultaneous thermocycling significantly reduces the strength of both of the all-ceramic materials. Moreover, further research is needed to define potentials, limits, and long-term serviceability of the materials and hybrid abutments.

A survey of experience-based preference of Nickel-Titanium rotary files and incidence of fracture among general dentists

  • Lee, WooCheol;Song, Minju;Kim, Euiseong;Lee, Hyojin;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.4
    • /
    • pp.201-206
    • /
    • 2012
  • Objectives: The purpose was to investigate the preference and usage technique of NiTi rotary instruments and to retrieve data on the frequency of re-use and the estimated incidence of file separation in the clinical practice among general dentists. Materials and Methods: A survey was disseminated via e-mail and on-site to 673 general dentists. The correlation between the operator's experience or preferred technique and frequency of re-use or incidence of file fracture was assessed. Results: A total of 348 dentists (51.7%) responded. The most frequently used NiTi instruments was ProFile (39.8%) followed by ProTaper. The most preferred preparation technique was crown-down (44.6%). 54.3% of the respondents re-used NiTi files more than 10 times. There was a significant correlation between experience with NiTi files and the number of re-uses (p = 0.0025). 54.6% of the respondents estimated experiencing file separation less than 5 times per year. The frequency of separation was significantly correlated with the instrumentation technique (p = 0.0003). Conclusions: A large number of general dentists in Korea prefer to re-use NiTi rotary files. As their experience with NiTi files increased, the number of re-uses increased, while the frequency of breakage decreased. Operators who adopt the hybrid technique showed less tendency of separation even with the increased number of re-use.

Effect of cement type, luting protocol, and ceramic abutment material on the shade of cemented titanium-based lithium disilicate crowns and surrounding peri-implant soft tissue: a spectrophotometric analysis

  • Peter Gehrke;Maria Julia Pietruska;Johannes Ladewig;Carsten Fischer;Robert Sader;Paul Weigl
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.4
    • /
    • pp.231-243
    • /
    • 2024
  • PURPOSE. The objective of the study was to analyze the impact of cement, bonding pretreatment, and ceramic abutment material on the overall color results of CAD-CAM ceramic crowns bonded to titanium-based hybrid abutments. MATERIALS AND METHODS. For single implant restoration of a maxillary lateral incisor a total of 51 CAD-CAM-fabricated monolithic lithium disilicate crowns were fabricated and subsequently bonded onto 24 lithium disilicate Ti-base abutments, 24 zirconia Ti-base abutments and 3 resin abutment replicas as a control group. The 48 copings were cemented with three definitive and one provisional cement on both grit-blasted and non-blasted Ti-bases. The color of each restoration and surrounding artificial gingiva was measured spectrophotometrically at predefined measuring points and the CIELAB (ΔEab) color scale values were recorded. RESULTS. The color outcome of ceramic crowns bonded to hybrid abutments and soft tissues was affected differently by cements of different brands. Grit-blasting of Ti-bases prior to cementing CAD-CAM copings affected the color results of allceramic crowns. There was a significant difference (P = .038) for the median ΔE value between blasted and non-blasted reconstructions at the cervical aspect of the crown. Full-ceramic crowns on zirconia Ti-base abutments exhibited significantly lower ΔE values below the threshold of visibility (ΔE 1.8). In all subcategories tested, the use of a highly opaque temporary cement demonstrated the lowest median ΔE for both the crown and the artificial gingiva. CONCLUSION. Various cements, core ceramic materials and airborne particle abrasion prior to bonding can adversely affect the color of Ti-base supported ceramic crowns and peri-implant soft tissue. However, zirconia CAD-CAM copings and an opaque cement can effectively mask this darkening.