• Title/Summary/Keyword: Hybrid PCS

Search Result 51, Processing Time 0.023 seconds

Hybrid Energy Storage System with Emergency Power Function of Standardization Technology (비상전원 기능을 갖는 하이브리드 에너지저장시스템 표준화 기술)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.2
    • /
    • pp.187-192
    • /
    • 2019
  • Hybrid power storage system with emergency power function for demand management and power outage minimizes the investment cost in the building of buildings and factories requiring emergency power generation facilities, We propose a new business model by developing technology that can secure economical efficiency by reducing power cost at all times. Normally, system power is supplied to load through STS (Static Transfer Switch), and PCS is connected to system in parallel to perform demand management. In order to efficiently operate the electric power through demand forecasting, the EMS issues a charge / discharge command to the ESS as a PMS (Power Management System), and the PMS transmits the command to the PCS controller to operate the system. During the power outage, the STS is rapidly disengaged from the system, and the PCS becomes an independent power supply and can supply constant voltage / constant frequency power to the load side. Therefore, it is possible to secure reliability through verification of actual system linkage and independent operation performance of hybrid ESS, By enabling low-carbon green growth technology to operate in conjunction with an efficient grid, it is possible to improve irregular power quality and contribute to peak load by generating renewable energy through ESS linkage. In addition, the ESS is replacing the frequency follow-up reserve, which is currently under the charge of coal-fired power generation, and thus it is anticipated that the operation cost of the LNG generator with high fuel cost can be reduced.

A PCS Control Strategy for Hybrid ESS with Function of Emergency Power Supply (비상전원 기능을 갖는 하이브리드 ESS를 위한 PCS 제어전략)

  • Kim, Sang-Jin;Kwon, Min-Ho;Choi, Se-Wan;Paik, Seok-Min;Kim, Mi-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.4
    • /
    • pp.302-311
    • /
    • 2016
  • This paper proposes a hybrid ESS that integrates an energy storage system (ESS) with an uninterruptible power supply (UPS). The hybrid ESS has a demand management and emergency power supply function while increasing the battery utilization of the UPS, which has just been used in a power failure. In addition to the critical load, the proposed system augments the capacity of emergency generation using an additional load, which has voltage and frequency-dependent characteristics to the grid side. The control algorithm of the AC-DC converter and bidirectional DC-DC converter is proposed for demand management and emergency power supply. Furthermore, seamless and autonomous transfer methods to alleviate the transient during mode transfer are proposed. To validate the proposed control scheme, experimental results from a 5 kW prototype are provided.

Tensile Properties and Adhesion of Hybrid-Type Anti-Corrosion Polymer Cement Slurry (하이브리드형 방식 폴리머 시멘트 슬러리의 인장특성 및 접착성)

  • Jo, Young-Kug
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.5
    • /
    • pp.635-642
    • /
    • 2008
  • In recent years, epoxy-coated reinforcing bars have been widely used in order to prevent the corrosion of ordinary reinforcing bar. However, they have a bad balance between performance and cost. Especially, they have a brittleness properties, low bond strength to cement concrete and no good bend-ability in the field. The purpose of this study is to evaluate the tensile properties and adhesion of hybrid-type anti-corrosion polymer cement slurry (PCS). PCSs are prepared with four types polymer dispersions using fly ash and silica fume, and tested for proper coating thickness, tensile properties, adhesion to steel plate and bend-ability. From the test results, the viscosity of PCS is effected by polymer dispersion types, and is a little decreased by using fly ash. The coating thickness of PCS has a proper thickness at polymer-binder ratio of 100%. It is apparent that the coating thickness has various values according to viscosity of PCS, water-binder ratio and polymer-binder rato. PCS has a good various anticorrosion properties and physical properties such as tensile strength, adhesion and bend-ability. It is also recommended that proper coating thickness to reinforcing bar is in the ranges of 150 to $250{\mu}m$ for bond strength, adhesion and bend-ability. It is also expected that the coated reinforcing bar using PCS is widely used instead of epoxy coated reinforcing bar in the industrial field.

Analysis on the Characteristics of Photovoltaic/Wing Hybrid PCS System (태양광.풍력 복합발전용 PCS시스템 제어특성분석)

  • 정영석;유권종;강기환;송진수;김홍성
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.1
    • /
    • pp.19-25
    • /
    • 2000
  • 본 논문은 배터리 충방전 제어기를 가지는 독립형 태양광·풍력 복합발전시스템에 대해서 기술한다. 복합발전시스템의 주요 전력원은 일반적으로 태양전지 어레이, 풍력발전, 배터리로 구성된다. 태양광·풍력 복합발전시스템은 기상조건의 상호 보완성 때문에 풍력 또는 태양광을 단독으로 이용하는 것에 비해서 배터리 수요를 줄일 수 있으며, 자연에너지의 활용도를 높이는 장점이 있다. 제안된 복합발전시스템은 충방전 제어기가 포함되어 있어 태양전지 어레이의 최대출력에서 동작할 수 있도록 순시치 제어기로 설계하였다. 본 논문에서는 실험을 통하여 시스템의 동작특성을 검증하였다.

A Study on the Performance of MAC Protocols for High-Speed Mobile Data Services (이동 고속데이타 서비스용 MAC계층 프로토콜의 성능연구)

  • 김태규;조동호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.9
    • /
    • pp.1730-1738
    • /
    • 1994
  • Broadband code division multiple access(B-CDMA)previously proposed for personal communication services(PCS) is not suitable for high-speed data services with large variations in speed, because it is designed only for low-speed voice calls with small variations in speed. Meanwhile, hybrid intra-cell TDMA/inter-cell CDMA(Hybrid TDMA/CDMA) recently proposed could accomodate high-speed services easily because of its internal use of the TDMA scheme, but there would be much inefficiency in treating variable bit rate services due to the intrinsic properties of TDMA transmission scheme, In this paper, a media access control(MAC) protocol, called Resevation TDMA/CDMA, which uses a reservation scheme similar to the one in the packet reservation multiple access(PRMA) protocol to compensate for these shortcomings is proposed. In addition, the performance of this protocol is analyzed and compared with conventional protocols by computer simulation. According to the simulation results, it has been shown that the proposed Reservation TDMA/CDMA scheme could support various transmission rates of user data traffics easily, and it could utilize the variations of the treansmission rates in each active call more efficiently.

  • PDF

Metal Phone MIMO Antenna with Auxiliary Slot (보조 슬롯에 의한 메탈 폰 MIMO 안테나)

  • Lee, Won-Hee;Park, Minkil;Son, Taeho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.3
    • /
    • pp.248-256
    • /
    • 2015
  • In this paper, a hybrid MIMO antenna for the metal phone with auxiliary slot for 4th generation mobile communication is designed and implemented. Auxiliary slot locates on the rear metal cover of the phone, and handles for LTE class 40 band. The auxiliary slot operates hybrid with a monopole antenna. Studied antenna satisfies under VSWR 3:1 for LTE class 13/ LTE class 14/ CDMA/ GSM/ DCS/ PCS/ W-CDMA/ LTE class 40 bands. ECC(Envelope Correlation Coefficient) value for MIMO characteristic is less than 0.2 over the whole design bands. Average gains and antenna efficiencies measured by MTG anechoic chamber were -5.57~-1.45 dBi and 27.75~71.6 %, respectively.

A Study on ESS Optimal Operation Strategy Using Two Stage Hybrid Optimization (Two Stage Hybrid Optimization을 사용한 ESS 최적 운전 전략에 대한 연구)

  • Gong, Eun-Kyoung;Sohn, Jin-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.833-839
    • /
    • 2018
  • This paper presents an analysis and the methodology of optimal operation strategy of the ESS(Energy Storage System) for reduce electricity charges. Electricity charges consist of a basic charge based on the contract capacity and energy charge according to the power usage. In order to use electrical energy at minimal charge, these two factors are required to be reduced at the same time. QP(Quadratic Programming) is appropriate for minimization of the basic charge and LP(Linear Programmin) is adequate to minimize the energy charge. However, the integer variable have to be introduced for modelling of different charge and discharge efficiency of ESS PCS(Power Conversion System), where MILP(Mixed Integer Linear Programming) can be used. In this case, the extent to which the peak load savings is accomplished should be assumed before the energy charge is minimized. So, to minimize the electricity charge exactly, optimization is sequentially performed in this paper, so-called the Two Stage Hybird optimization, where the extent to which the peak load savings is firstly accomplished through optimization of basic charge and then the optimization of energy charge is performed with different charge and discharge efficiency of ESS PCS. Finally, the proposed method is analyzed quantitatively with other optimization methods.

Metal Phone MIMO Antenna Using the Auxiliary Letter Slot (보조 문자슬롯을 이용한 메탈폰 MIMO 안테나)

  • Lee, Won-hee;Son, Taeho;Jo, Youngmin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.4
    • /
    • pp.395-398
    • /
    • 2016
  • In this paper, a hybrid MIMO antenna for the mobile communication metal phone with auxiliary letter slot is designed and implemented. Auxiliary letter slot locates on the rear metal cover of the phone, and operates on LTE class 40 band. The slots of two letters are designed and operated with monopole+IFA hybrid antenna. Antenna satisfies under VSWR 3: 1 for LTE class 13 / LTE class 14 / CDMA / GSM / DCS / PCS / W-CDMA / LTE class 40 bands. Average gains and antenna efficiencies measured by the anechoic chamber were -5.57~-1.45 dBi and 27.75~71.6 %, respectively.

Broadband Main and Sub Antenna Connected by the Transmission Line (전송선으로 연결된 광대역 주, 부 안테나)

  • Park, Mingil;Son, Taeho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.13 no.2
    • /
    • pp.42-49
    • /
    • 2014
  • A broadband antenna using a main and a sub antenna for the mobile communication terminal such as mobile phone and ITS terminal is designed. Two antennas are based on the hybrid antenna that is operating both a monopole and a IFA(Inverted F Antenna). It's applied the transmission line to connect both antennas. Sub antenna located in small space of the terminal allows space usability for the terminal design. Antenna for the hexa-frequency band of LTE700, CDMA, GSM, DCS, PCS and WCDMA is designed and implemented on the bare PC board that is same size of the mobile phone. This antenna was measured 3 : 1 VSWR over the whole design band. And average gains and efficiencies were-3.78 ~ -2.62dBi and 41.9 ~ 54.73% for LTE700/CDMA/GSM frequency band, -3.75 ~ -1.84dBi and 42.19 ~ 65.46% for DCS/PCS/WCDMA frequency band.

Performance Analysis of Hybrid Location Update Strategy in Wireless Communication System (이동 통신망에서의 혼합형 위치 갱신 방법의 성능분석)

  • Lee, Goo-Yeon
    • Journal of Industrial Technology
    • /
    • v.26 no.B
    • /
    • pp.191-198
    • /
    • 2006
  • In this paper, we focus on a question. Which is better between time-based location update method and movement-based location update method? Or, does any other method combining the two methods show better performance? For the question, we propose a hybrid location update scheme, which integrates the time-based and the movement-based methods. In the proposed scheme, a mobile terminal updates its location after n cell boundary crossing and a time interval of T, or the inverse. We derive an analytical solution for the performance of the hybrid scheme with exponential cell resident time. From the numerical analysis, we conclude that the movement-based method seems to have better performance than the time-based and hybrid methods, that is the optimal costs occur at T=0.

  • PDF