• 제목/요약/키워드: Hybrid Image

검색결과 534건 처리시간 0.025초

LCD Color Filter용 Hybrid Azo Colorants 합성 및 특성 연구 (Synthesis and Characterization of Hybrid Azo Colorants for LCD Color Filter)

  • 최우근;정연태
    • 한국전기전자재료학회논문지
    • /
    • 제26권7호
    • /
    • pp.528-533
    • /
    • 2013
  • We focused on the development of red azo colorants with high thermal stability and good solubility for LCD color filter in this research. For the synthesis of hybrid azo colorants, we used the couplers of aniline, naphthol and benzoimidazol functional group. The synthesized hybrid azo colorants were charaterized by using NMR, UV/visible spectroscopy, FT-IR, EA and TGA. They represented the maximum absorption wavelengths which are longer than 500 nm in UV/visible spectrum. So they were confirmed to be suitable for red colorants of LCD color filter. Azo compound (1a, 1b) with aniline functional group had good solubility in organic solvents such as acetone, methanol, chloroform and PGMEA. Moreover azo compounds (1c, 1d and 1e) with naphthol and benzoimidazolone functional group gave excellent thermal stability higher than $250^{\circ}C$ in TGA thermograms.

관상동맥질환에서 심장 하이브리드 영상의 임상적 이용 (Clinical Application of Cardiac Hybrid Imaging in Coronary Artery Disease)

  • 조인호;공은정
    • Journal of Yeungnam Medical Science
    • /
    • 제26권1호
    • /
    • pp.15-23
    • /
    • 2009
  • Constant technological developments in coronary artery disease have contributed to the assessment of both the presence of coronary stenosis and its hemodynamic consequences. Hence, noninvasive imaging helps guide therapeutic decisions by providing complementary information on coronary morphology and on myocardial perfusion and metabolism. This can he done using single photon emission computed tomography (SPECT) or positron emission tomography (PET) and multidetector CT (MDCT). Advances in image-processing software and the advent of SPECT/CT and PET/CT have paved the way for the combination of image datasets from different modalities, giving rise to hybrid imaging. Three dimensional cardiac hybrid imaging helped to confirm hemodynamic significance in many lesions, add new lesions such as left main coronay artery disease, exclude equivocal defects, correct the corresponding arteries to their allocated defects and identify culprit segment. Cardiac hybrid imaging avoids the mental integration of functional and morphologic images and facilitates a comprehensive interpretation of coronaty lesions and their pathophysiologic adequacy by three dimensional display of fused images, and allows the best evaluation of myocardial territories and the coronary-artery branches that serve each territory. This integration of functional and morphological information were feasible to intuitively convincing and might facilitate development of a comprehensive non-invasive assessment of coronary artery disease.

  • PDF

BTC와 DPCM을 결합한 영상신호의 복합 부호화와 성능평가 (A Hybrid Image Coding Using BTC and DPCM with Performance Evaluation)

  • 고형화;이충웅
    • 대한전자공학회논문지
    • /
    • 제25권4호
    • /
    • pp.447-452
    • /
    • 1988
  • This paper proposes a hybrid image coding in order to improve the coding performance by combining the BTC with the DPCM. And utilizing the human perceptual characteristics, a new objective image quality evaluation method has been proposed to obtain an excellent result in good agreement with the subjective quality evaluation. A hyb-1 method consisting of the DPCM and the AMBTC has retained a good picture quality at the bit rate of 1.5 bits/pel. A hyb-3 method combining the EBTC-3 with the DPCM has scarcely degraded the picture quality compared with the original image at the bit rate of 2.1 bits/pel. A newly proposed mehtod of picture quality evaluation accumulating a blocky noise at the edge block and an impulsive noise at the flat block selectively has been coincident with the subjective evaluation of quality.

  • PDF

새로운 속도함수를 갖는 레벨 셋 방법을 이용한 의료영상분할 (Image Segmentation Using Level Set Method with New Speed Function)

  • 김선월;조완현
    • 응용통계연구
    • /
    • 제24권2호
    • /
    • pp.335-345
    • /
    • 2011
  • 본 논문에서는 레벨 셋 방법을 이용하여 영상분할을 수행하는데 필요한 새로운 하이브리드 속도함수를 제안한다. 새롭게 제안하는 속도함수는 정확한 분할 결과를 위하여 영상의 객체가 가지고 있는 영역정보와 윤곽선정보를 함께 이용한다. 영역정보는 관심이 있는 물체영상내의 픽셀들의 밝기에 대한 확률분포의 정보를 이용하였고, 윤곽선정보는 영상의 에지의 기울기로부터 주어지는 기울기 벡터장을 이용하였다. 제안된 방법을 이용한 분할결과의 정확성을 확인하기 위하여 가상영상과 실제 사용되는 의료영상에 대하여 다양한 실험을 실시하고, 분할된 결과를 통하여 제안된 방법의 우수성을 입증하였다.

메디안 혼성 필터의 잡음 특성 개선 (A Study on the Characteristics of noise smoothing in FIR-Median Hybrid Filters)

  • 최삼길;김창규;전계록;김명기;변건식
    • 한국통신학회논문지
    • /
    • 제17권11호
    • /
    • pp.1185-1198
    • /
    • 1992
  • 본 논문에서는 기존의 메디안필터와 메디안혼성필터의 잡음 제거 특성을 개선하기 위하여 차등가중치 알고리즘을 제안하였고, 이 알고리즘을 적용한 메디안혼성필터와 기존의 메디안필터 및 메디안혼성필터를 단순 영상과 실제 영상에 적용하여 영상의 잡음 제거 특성과 미세 부분 및 경계보존 특성을 비교, 검토하였다. 본 논문에 사용된 단순 영상은 임펄스, 가우스, 지수 및 라플라션 잡음이 첨가된 Lenna 영상이며, 실제 영상은 임펄스 잡음이 첨가된 Urological영상이다. 본 연구의 실험 결과 차등가중치 알고리즘이 적용된 메디안혼성필터가 기존의 메디안필터 및 메디안혼성필터보다 비교적 양질의 영상을 구현할 수 있었으나, 필터의 차수가 증가할수록 영상처리에 많은 시간이 소요되었다. 그러나 영상의 형태에 따라 적절한 필터링을 선택하여 적용하면 향후 컴퓨터를 이용한 여러 응용 분야 및 의학 영상 처리 분야등에 상당한 도움이 되리라고 사료된다.

  • PDF

Evaluation of RF shielding materials to improve MR image of hybrid PET/MRI

  • Hyun Keong Lim;Yong Choi;Jin Ho Jung;Jiwoong Jung;Changheun Oh;Hyun-wook Park;Jong Guk Kim
    • Journal of the Korean Physical Society
    • /
    • 제80권
    • /
    • pp.640-646
    • /
    • 2022
  • Hybrid PET/MRI is a useful imaging system that can improve diagnostic accuracy by providing both functional and anatomical information. However, the combination of PET and MRI can lead to mutual interference, which can degrade the performances of both imaging systems. One of the methods that is capable of preserving the performance of both modalities is to apply RF shielding to PET detectors and electronics. The purpose of this study was to propose a new RF shielding method using Au-plated conductive fabric (PCF) tape that could not only minimize RF interference and eddy current, but that could also be applied to complex PET gantry and detector module structures more easily than thin Cu foils, which have been widely used as a shielding material for hybrid PET/MRI systems. To evaluate the performance of the proposed new RF shielding method, the effects of the two RF shield materials (Cu and Au) on the B1 + field generated by the RF head coil were estimated using a computer simulation method. The effects of the Au PCF tape and Cu foil on the homogeneity and SNR of the MR image were also experimentally evaluated using a commercial 3-T MRI. The uniformity of the B1 + field map was slightly decreased by the use of Cu and Au RF shields. The deterioration in the MR image quality caused by the Au PCF tape was less than that caused by Cu foil. The simulation and experimental results indicate that Au PCF tape can serve as an alternative shielding material that reduces RF interference and eddy current for hybrid PET/MRI systems.

디스크 레이저-아크 하이브리드 용접을 이용한 포지션 용접 (Position welding using disk laser-GMA hybrid welding)

  • 임현식;김정학;김철희;김정한
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1299-1306
    • /
    • 2007
  • The combination of laser beam and electric arc sharing common weld pool has widely been investigated since the late seventies, but it is beginning of the industrial uses. Recently, laser-GMA hybrid welding process showed possibility to overcome the tight gap tolerance with improved productivity. The laser-arc hybrid welding process is inherently complex because it has three kinds of process parameters: arc welding, laser welding and hybrid welding parameters. In this study, the optimum range of the process parameters were determined by high speed image analysis which could unveil the welding phenomena in laser-arc hybrid welding. The laser-arc hybrid welding was applied for position welding from the flat position to the overhead position and the welding characteristics were investigated.

  • PDF

Fabrication of Organic-Inorganic Hybrid Thin Film by Molecular Layer Deposition

  • 한규석;김수환;한기복;성명모
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.251-251
    • /
    • 2010
  • Organic-inorganic hybrid materials have attracted because of its combined properties, such as flexibility and high electrical performance. In addition, the hybrid materials are expected to have synergic effect which are not shown in just one component. Here, we fabricated organic-inorganic hybrid thin film. Organic-inorganic hybrid thin film have been deposited from diethyl zinc and 1, 2, 4-trihydroxybenzene (THB) by molecular layer deposition (MLD). UV-VIS, Using Infrared spectrum and X-ray photoelectron spectroscopy confirm that Zinc and THB hybrid film (ZnTHB) consist of Zn-O and THB - oxide units and the micro structure and composition of hybrid film. hat the sequential surface reactions of diethyl zinc and ethylene glycol are sufficiently self-limiting and saturating to enable well-controlled MLD growth. Transmission electron microscopy image shows lamination growth of ZnTHB film according to cycle.

  • PDF

재구성 가능한 다중 프로세서 시스템을 이용한 혼합 영상 보호화기 구현에 관한 연구 (연구 I : H/W구현) (A Study on Hybrid Image Coder Using a Reconfigurable Multiprocessor System (Study I : H/W Implementation))

  • 최상훈;이광기;김제익;윤승철;박규태
    • 전자공학회논문지B
    • /
    • 제30B권10호
    • /
    • pp.1-12
    • /
    • 1993
  • A multiprocessor system for high-speed processing of hybrid image coding algorithms such as H.261, MPEG, or Digital HDTV is presented in this study. Using a combination of highly parallel 32-bit microprocessor, DCT(Discrete Cosine Transform), and motion detection processor, a new processing module is designed for the implementation of high performance coding system. The sysyem is implemented to allow parallel processing since a single module alone cannot perform hybrid coding algorithms at high speed, and crossbar switch is used to realize various parallel processing architectures by altering interconnections between processing modules within the system.

  • PDF

A Hybrid Encryption Technique for Digital Holography using DCT and DWT

  • Choi, Hyun-Jun;Seo, Young-Ho;Kim, Dong-Wook
    • Journal of information and communication convergence engineering
    • /
    • 제9권3호
    • /
    • pp.271-275
    • /
    • 2011
  • In this paper, we present a hybrid encryption for a digital hologram which is the most valuable image content. The encryption algorithm is based on a hybrid technique implementation a four-dimensional transform combining the discrete wavelet transform(DWT) and the discrete cosine transform (DCT). The encryption scheme is composed on the basis of the energy distribution. The experimental results showed that encrypting only 0.0244% of the entire data was enough to hide the constants of the hologram. The encryption algorithm expected to be used effectively on the researches on encryption and others for digital holographic display.