• Title/Summary/Keyword: Hybrid Fuel Cell

Search Result 303, Processing Time 0.023 seconds

Renewable Source and Hybrid System Modeling for Smart Grid (스마트그리드를 위한 신재생에너지원과 하이브리드시스템 모델링)

  • Cho, Jae-Hoon;Hong, Won-Pyo;Chun, Myung-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.109-121
    • /
    • 2010
  • Recently, smart grid for solving energy problems have been receiving growing attention. Also, renewable energy sources such as photovoltaic and fuel cell as future energy for realizing smart grid have been widely studied. On the other hand, hybrid structures have been proposed since the output power of these renewable energy sources is usually dependent on weather conditions. This paper proposes a hybrid system involving a proper photovoltaic in the hybrid system, Polymer Elecrolyte Membrane Fuel Cell with water electrolyzer and ultracapacitor. The results of simulation and output of the proposed model are established and analysed by Matlab/Simulink and SimPowerSystems.

Effect of Gas Bypass at Turbine Inlet on Design of a Pressurized Solid Oxide Fuel Cell / Gas Turbine Hybrid System (가압형 고체산화물 연료전지 / 가스터빈 하이브리드 시스템 설계에서 터빈입구 바이패스의 효과)

  • Park, S.K.;Sohn, J.L.;Kim, T.S.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.1
    • /
    • pp.33-39
    • /
    • 2008
  • Hybrid power generation systems combining a solid oxide fuel cell and a gas turbine is promising due to their high efficiency. In the pressurized hybrid system, the operating condition of the gas turbine may play a critical role in designing the hybrid system. In particular, prevention of surge of the compressor can be a critical issue. The existence of fuel cell between the compressor and the turbine may cause an additional pressure loss and thus compressor operating points tend to approach the surge if the original turbine inlet temperature is pursued. In this study, bypassing some of the turbine inlet gas directly to the turbine exit side is simulated. Its effects on suppressing the surge problem and change in performance characteristics are discussed.

A Novel Single Converter and Single Inverter (1Con-1Inv) Topology and Control Algorithm for Photovoltaic-Fuel Cell Hybrid System (태양광-연료전지 하이브리드 발전을 위한 새로운 단일 컨버터 및 단일 인버터 (1Con-1Inv) 회로 및 제어 알고리즘)

  • Kim, Jong-Soo;Choe, Gyu-Yeong;Lee, Byoung-Kuk;Won, Chung-Yuen;Lee, Tae-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2200-2208
    • /
    • 2009
  • This paper presents a novel single converter and single inverter (1Con-1Inv) topology for photovoltaic (PV)-fuel cell (FC) hybrid system and a new control scheme for the PV-FC hybrid system is then proposed. The new topology and the unique algorithm can minimize volume and production cost of the hybrid system. Moreover, system efficiency can improve due to reduction of losses of hardware components and other control factors are well regulated using just 1Con-1Inv with the help of the proposed control algorithm. The validity of proposed algorithm is verified both computer simulation using PSIM and Matlab/Simulink program and experimental with 700W of PV and 600W of FC system.

Efficiency Evaluation of a Hybrid Propulsion Fuel Cell Ship Based on AIS Data (항적 데이터에 기반한 하이브리드 추진 연료전지 선박의 효율 평가)

  • Donghyun Oh;Dae-Seung Cho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.3
    • /
    • pp.146-154
    • /
    • 2023
  • Efforts have been made to reduce the greenhouse gas emissions from ships by limiting the energy efficiency index, and net zero CO2 emission was proposed recently. The most ideal measure to achieve zero emission ship is electrification, and fuel cells are considered as a practical power source of the electrified propulsion system. The electric efficiency in the electrochemical reaction of fuel cells can be achieved up to 60% practically. The remaining energy is converted to heat energy but most of them are dissipated by cooling. In the author's previous research, a hybrid propulsion system utilizing not only electricity but also heat was introduced by combining electric motor and steam turbine. In this article, long term efficiency is evaluated for the introduced hybrid propulsion system by considering a virtual 24,000 TEU class container carrier model. To reflect a more practical operating condition, the actual navigation data of a similar real ship in the real world were collected from automatic identification system data and applied. From the result, the overall efficiency of the hybrid propulsion system is expected to be higher than a conventional electric propulsion fuel cell ship by 30%.

Environmental Evaluation for a Photovoltaic-Fuel Cell Hybrid Power System (태양전지-연료전지 복합 전력시스템에 대한 환경평가에 관한 연구)

  • 노경수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.83-88
    • /
    • 1998
  • This paper presents an overview of environmental evaluation for a photovoltaic-fuel cell hybrid power plant through the Ideal Point approach, which is one of multiobjective decision support systems. Its evaluation is carried out in terms of such tow criteria as land requirement for plant construction and lifetime CO2 emissions, and ten compared with conventional fossil fuel power plants. Fuel cell power system has been proven a viable technology to back up severe PV power fluctuations under inclement weather conditions. Fuel cell power generation, containing small land use, is able to alleviate the heavy burden of large surface requirement of PV power plants. In addition, the PV-fuel cell hybrid power system shows a very little potential for lifetime CO2 emissions.

  • PDF

Part-load Performance Characteristics of a Solid Oxide Fuel Cell/Gas Turbine Hybrid Power System Operating with Various Load-following Operation Modes (부하추종 운전방법에 따른 고체산화물 연료전지/가스터빈 하이브리드 동력 시스템의 부분부하 성능특성)

  • Kim Jae-Hoon;Yang Jin-Sik;Ro Sung-Tack;Sohn Jeong-Lak
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.3 s.246
    • /
    • pp.193-200
    • /
    • 2006
  • The purpose of this study is to compare the part-load performance of a SOFC/GT hybrid power system with three different kinds of load-following operation modes. The primary mode for the part load operation of a hybrid power system is the reduction of supplied fuel (e.g., fuel control mode) to the hybrid system. The other two options, i.e., variable speed and VIGV controls, are related to the reduction of supplied air simultaneously with the reduction of supplied fuel to the system. With the performance analysis of a SOFC/GT hybrid power system, it is concluded that the variable speed con佐ol mode Provides the best performance for the part-load operations. It is also found that the VIGV control mode, with its better performance behavior than the fuel control mode, can be used as an important option for the part-load operation especially in case that the variable speed control mode can not be adopted.

Comparative Performance Analysis of Small Pressurized Fuel Cell/Gas Turbine Hybrid Systems (소형 가압형 연료전지/가스터빈 하이브리드 시스템의 성능 비교해석)

  • Park, Sung-Ku;You, Byung-June;Kim, Tong-Seop;Sohn, Jeong-L.;Ahn, Kook-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.9
    • /
    • pp.652-658
    • /
    • 2008
  • Design performances of the fuel cell / gas turbine hybrid power generation systems based on two different fuel cells (PEMFC, SOFC) have been comparatively analyzed. In each system, the fuel cell operates at an elevated pressure corresponding to the compressed air pressure of the gas turbine. Both internally and externally reformed systems were analyzed for the SOFC hybrid system. Component design parameters of 10kW class small systems are assumed. For all hybrid systems, increasing the turbine inlet temperature increases the power portion of the gas turbine. With increasing the turbine inlet temperature, system efficiency decreases in the PEMFC system and the internally reformed SOFC system while that of the externally reformed SOFC system increases slightly. The internally reformed SOFC hybrid system is predicted to exhibit the best system efficiency.

Thermodynamic Analysis on Hybrid Molten Carbonate Fuel Cell - Turbo Expander System for Natural Gas Pressure Regulation (용융탄산염연료전지와 터보팽창기를 이용한 천연가스 정압기지의 열역학적 분석)

  • Sung, Taehong;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.2
    • /
    • pp.28-34
    • /
    • 2014
  • In the natural gas pressure regulation station, high pressure natural gas is decompressing using pressure regulation valves. Waste pressure occurred in the pressure regulation process can be recovered through adopting turbo expanders. However, in the waste pressure recovery process, Joule Thompson effect causes below $0^{\circ}C$ and this low temperature freezes outside land of pipeline or generates methane hydrate in the pipeline which can block the pipeline. Therefore, turbo expander systems are accompanying with a boiler for preheating natural gas. Molten carbonate fuel cell (MCFC), one of the high temperature fuel cell, can use natural gas as a direct fuel and is also exhausting low emission gas and generating electricity. In this paper, a thermodynamic analysis on the hybrid MCFC-turbo expander system is conducted. The fuel cell system is analyzed for the base load of the hybrid system.

Performance Analysis of Methane Fueled Marine Solid Oxide Fuel Cell and Steam Turbine Hybrid Power System (선박동력용 SOFC/ST 하이브리드시스템의 성능 평가)

  • Lee, Kyung-Jin;Oh, Jin-Suk;Kim, Sun-Hee;Oh, Sae-Gin;Lim, Tae-Woo;Kim, Jong-Su;Park, Sang-Kyun;Kim, Mann-Eung;Kim, Myoung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.590-599
    • /
    • 2011
  • The electrification of the waste heat of fuel cell is necessary to enhance the efficiency of fuel cell system. For this purpose, the SOFC/ST(Solid oxide fuel cell/Steam turbine) hybrid system is suitable. The purpose of this work is to predict the performance of methane fueled SOFC/ST hybrid power system and to analyze the influence of operating temperature of stack, current density of stack, combustor outlet gas temperature, and boiler outlet gas temperature. According to the analysis, it is proved that making the best use of the waste heat of stack and minimizing the fuel consumption of combustor are essential for the high-efficiency of SOFC/ST hybrid system.