• 제목/요약/키워드: Hybrid FRP Rebar

검색결과 16건 처리시간 0.024초

하이브리드 FRP 리바의 역학적 특성 (Mechanical Properties of Hybrid FRP Rebar)

  • 박찬기;원종필
    • 한국농공학회지
    • /
    • 제45권2호
    • /
    • pp.58-67
    • /
    • 2003
  • Over the last decade fiber-reinforced polymer (FRP) reinforcement consisting of glass, carbon, or aramid fibers embedded in a resin such as vinyl ester, epoxy, or polyester has emerged as one of the most promising and affordable solutions to the corrosion problems of steel reinforcement in structural concrete. But reinforcing rebar for concrete made of FRP rebar has linear elastic behavior up to tensile failure. For safety a certain plastic strain and an elongation greater than 3% at maximum load is usually required for steel reinforcement in concrete structures. The same should be required for FRP rebar. Thus, the main object of this study was to develop new type of hybrid FRP rebar Also, this study was evaluated to the mechanical properties of Hybrid FRP rebar. The Manufacture of the hybrid FRP rebar was achieved by pultrusion, and braiding and filament winding techniques. Tensile and interlaminar shear test results of Hybrid FRP rebar can provide its excellent tensile strength-strain behavior and interlaminar stress-strain behavior.

콘크리트 보강용 하이브리드 FRP 리바의 특성 (The properties of hybrid FRP rebar for concrete structures)

  • 원종필;박찬기;황금식;윤종환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.255-260
    • /
    • 2003
  • The corrosion of steel rebars has been the major cause of the reinforced concrete deterioration. It is FRP rebar that is developed to solve problem of such steel rebar. FRP rebar in concrete structures should be used as a substitute of steel rebars for that cases in which aggressive environment produce high steel corrosion, or lightweight is an important design factor, or transportation cost increase significantly with the weight of the materials. But FRP rebar have only linearly elastic behavior; whereas, steel rebar has linear elastic behavior up to the yield point followed by large plastic deformation and strain hardening. Thus, the current FRP rebars are not suitable concrete reinforcement where a large amount of plastic deformation prior to collapse in required. The main objective of this study was to develop new type of hybrid FRP rebar. The manufacture of the hybrid FRP rebar was achieved pultrusion, braiding and filament winding techniques. Tensile and interlaminar shear test results of hybrid FRP rebar can provide its excellent tensile strength-strain behavior and interlaminar stress-strain behavior.

  • PDF

고연성 하이브리드 FRP 리바의 화학적 환경 노출 후 부착 성능 (Bond Performance of Ductile Hybrid FRP Rebar After Chemical Environmental Exposures)

  • 원종필;박찬기;서정민;공태웅;성상경;최석원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.333-336
    • /
    • 2004
  • In this study focuses on bond properties of hybrid FRP rebar after chemical environmental exposure. Hybrid FRP rebar bond specimens were subjected to four type of exposure conditions. Bond properties were investigated by direct bond test. Bond test results, hybrid FRP rebars were found to have better bond strength with concrete than currently using GFRP rebar. Also, hybrid FRP rebar had more than about $80\%$ in bond strength of steel rebar.

  • PDF

콘크리트 구조물용 하이브리드 섬유강화 복합재료 리바 물성에 관한 실험적연구 (An Experimental Study on the Mechanical Properties of Hybrid Fiber Reinforced Plastic(FRP) Rebar for Concrete Structure)

  • 배시연;신용욱;한길영;이동기;심재기
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 춘계학술발표대회 논문집
    • /
    • pp.63-66
    • /
    • 2000
  • This paper describes the need for a ductile Fiber Reinforced Plastic(FRP) reinforcement for concrete structures. Using the material hybrid and geometric hybrid, it is demonstrated that the pseudo-ductility characteristic can be generated in FRP rebar. Ductile hybrid FRP bars were successfully fabricated at 4mm and l0mm nominal diameters using an hand lay up method. Tensile specimens from these bars were tested and compared with behavior of FRP rebar and steel bar

  • PDF

라인 브레이딩 펄트루젼을 이용한 하이브리드 섬유강화 복합재료 리바 제작에 관한 연구 (A Study on the Manufacturing of Hybrid Fiber Reinforced Plastic Rebar Using In-Line Braiding and Pultrusion)

  • 신용욱;한길영;이동기;심재기;오환교
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.57-62
    • /
    • 2000
  • This paper describes the need for a ductile Fiber Reinforced Plastic(FRP) reinforcement for concrete structures. Using the material hybrid and geometric hybrid. it is demonstrated that the pseudo-ductility characteristic can be generated in FRP rebar. Ductile hybrid FRP bars were successfully fabricated at 4mm and 10mm nominal diameters using an hand lay up method. Tensile specimens from these bars were tested and compared with behavior of FRP rebar and steel bar

  • PDF

하이브리드 섬유강화 복합재료 리바의 연성효과 (Ductile Effect of Hybrid Fiber Reinforced Composite Rebar)

  • 최명선;한길영;이동기;안동기
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2003년도 추계학술대회 논문집
    • /
    • pp.112-116
    • /
    • 2003
  • This paper describes the need for a ductile of Fiber Reinforced Plastic(FRP) reinforcement for concrete structures. The criteria to be met by the FRP, which are based on the properties of the steel rebar it is to replace, are threefold: high initial modulus, a definite yield point and a high level of ultimate strain. It is shown that the use of a fiber architecture based design methodology facilitates the optimization of the performance of FRP through material and geometric hybrid. Ductile hybrid FRP bars were successfully fabricated at 3mm and 5mm nominal diameters using an in-line braiding and pultrusion process.

  • PDF

브레이드 투루젼법에 의한 콘크리트 구조물용 케블라-유리섬유 강화 복합재료 리바 특성 (Characteristics of Kevlar-Glass fiber reinforced plastic for Concrete Structure by the Braidtrusion process)

  • 최명선;곽상묵;배시연;이동기;심재기;한길영
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 춘계학술발표대회 논문집
    • /
    • pp.48-52
    • /
    • 2002
  • This paper describes the need for a ductile Fiber Reinforced Plastic(FRP) reinforcement for Concrete Structures. Using the material hybrid and geometric hybrid, it is demonstrated that the pseudo-ductility Characteristic can be generated in FRP rebar. Ductile hybrid FRP bars were successfully fabricated at Ø3mm and Ø10mm nominal diameters using the braidtrusion process. Tensile and bending specimens from these bars were tested and compared with behavior of stress-strain of steel bar and GFRP rebar

  • PDF

부분 비부착 NSM Hybrid FRP 보강근에 의한 철근콘크리트보의 연성보강 (Ductile Strengthening of Reinforced Concrete Beams by Partially Unbonded NSM Hybrid FRP Rebars)

  • 이차돈;정상모;원종필;이승환
    • 콘크리트학회논문집
    • /
    • 제15권1호
    • /
    • pp.143-153
    • /
    • 2003
  • 철근콘크리트를 FRP 복합재로 보강할 경우, 취성파괴를 방지하고 연성파괴를 확보할 수 있는 새로운 기법을 표면매립공법(Near Surface Mounted technique: 이하 NSM 공법)에 근거하여 제시하였다. 제안된 기법은 Hybrid FRP rebar를 부분적으로 비부착 시킴으로서 보강된 보의 연성을 확보한다. Hybrid FRP rebar의 일부를 비부착으로 한 경우와 전부를 부착으로 한 경우의 NSM 공법에 의한 FRP 보강된 철근 콘크리트보의 거동을 비교하기 위한 실험을 실시하였다. 실험 결과, 부분 비부착 NSM 공법으로 보강된 철근 콘크리트보만이 연성거동을 함이 관찰되었다. 부분 비부착 보강된 보의 극한 시 내력을 확보하기 위한 최소한의 FRP의 부분 비부착길이를 이론적으로 산정하여 제시하였다. 제시된 부분 비부착 NSM 공법은 FRP 복합재로 보강된 철근 콘크리트 부재의 구조적 거동을 크게 향상시킬 수 있으리라 기대된다.

콘크리트 보강용 FRP 보강근의 내구성 설계를 위한 환경영향계수의 제안 (Recommendations of Environmental Reduction Factor of FRP Rebar for Durability Design of Concrete Structure)

  • 박찬기;원종필;강주원
    • 콘크리트학회논문집
    • /
    • 제16권4호
    • /
    • pp.529-539
    • /
    • 2004
  • 철근콘크리트 구조물의 주요 파괴 원인은 철근의 부식에 의한 것으로 철근의 부식에 대한 문제점을 해결할 가능성이 있는 재료 중 FRP 보강근은 그 가능성이 높다. 그렇지만 이와 같은 FRP 보강근은 보강철근과 다른 파괴 메카니즘에 의하여 현저하게 성능이 저하될 가능성을 가지고 있다. 이와 같은 환경에는 알칼리 환경 등이 있다. 따라서 미국, 일본 캐나다 등 많은 나라에서는 환경영향계수를 사용하고 있다. 그렇지만 환경영향계수는 각 나라마다 다르게 적용되고 있는데 이는 FRP 보강근에 대한 장기거동에 대하여 명확한 기준이 제시되어 있지 않기 때문이다. 본 연구에서는 FRP 보강근의 환경영향계수를 제안하는데 그 목표를 두고 있다. 환경영향계수는 내구성 시험결과를 기본으로 하여 결정하였다. FRP 보강근은 알칼리 산 염해 등을 포함한 환경조건에 노출하였다. FRP 보강근은 간단한 질량변화를 측정하여 수분흡수 거동을 평가하였으며 역학적 특성의 변화는 인장, 압축 및 전단시험을 통하여 평가하였다. 시험결과를 기본으로하여 하이브리드 FRP 보강근(A)와 (C) 및 CFRP 보강근은 환경영향계수를 0.85로 결정하였고 하이브리드 FRP 보강근(B) 및 GFRP 보강근은 0.70으로 결정하였다.

UV 폭로 및 동결융해 시험을 거친 FRP Hybrid Bar의 인장거동 평가 (Evaluation of Tension Behavior in FRP Hybrid Bar Affected by UV Exposure and Freezing/Thawing Tests)

  • 윤용식;박재성;박기태;권성준
    • 한국건설순환자원학회논문집
    • /
    • 제5권2호
    • /
    • pp.130-136
    • /
    • 2017
  • 본 연구에서는 UV 폭로 및 동결융해 환경이 FRP Hybrid Bar의 인장거동 및 표면 열화에 미치는 영향을 평가하기 위해 FRP Hybrid Bar를 대상으로 UV 폭로 및 동결융해 시험을 실시하였다. FRP Hybrid Bar의 경우 UV 폭로 및 동결융해 180cycle 시험 전/후 외관적인 열화가 거의 발생하지 않았다. 또한 FRP Hybrid Bar의 주요 장점 중 하나인 인장경화특성은 동결융해 시험을 거친 이후에도 유지되었는데, 이는 UV 폭로시험을 거친 FRP Hybrid Bar에도 유효하게 평가되었다. UV 폭로시험을 거친 FRP Hybrid Bar는 일반 FRP Hybrid Bar와 거의 비슷한 인장거동을 나타내었으며, 동결융해 180cycle의 진행에도 불구하고 일반철근, FRP Hybrid Bar, UV 폭로를 거친 FRP Hybrid Bar의 인장거동은 큰 변화를 나타내지 않았다. 본 연구에서는 UV 폭로 및 동결융해 환경이 FRP Hybrid Bar의 외관 및 인장 특성에 큰 영향을 미치지 못하는 것으로 판단되지만, 충격에 따른 규사코팅의 박락은 콘크리트와의 부착력에 영향을 미치므로 이에 대한 고려가 필요하다.