• Title/Summary/Keyword: Hybrid Composite Joint

Search Result 59, Processing Time 0.022 seconds

Progressive Failure Analysis of UD-Fabric Hybrid Laminated Composite Joints Considering Material Nonlinearity (재료비선형을 고려한 일방향-평직 혼합 적층 복합재 체결부의 점진적 파손해석)

  • 최정석;신소영;안현수;권진회
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.79-82
    • /
    • 2002
  • A finite element method based on the two-dimensional progressive failure analysis considering material nonlinearity is presented for characterizing the strength and failure of the unidirectional-fabric hybrid laminated composite joints under pin loading. The 8-node laminated shell element is incorporated in the updated Lagrangian formulation. Failure criteria including the Maximum Stress and Tsai-Wu are used in conjunction with the complete unloading stiffness degradation method. For the verification, joint tests are conducted for the specimens with two different ply-number ratios of UD composite to fabric composite. Although there are some differences depending on ply-number ratios, the finite element model using the maximum stress criterion considering nonlinear material behavior predicts the failure strength best.

  • PDF

Evaluation on Structural Performance of Two-nodal Rotary Frictional Component (2절점 회전형 마찰요소의 구조성능 평가)

  • Kim, Do-Hyun;Kim, Ji-Young;Kim, Myeong-Han
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.4
    • /
    • pp.51-57
    • /
    • 2015
  • Various hybrid dampers have been developed in Korea to control the vibration due to a wind and earthquake. In order to minimize the installment space, cost and construction process, the new hybrid friction damper is developed. This hybrid damper is composed of several rotary friction components having two frictional joint. Because of these components, the building vibration due to wind and earthquake can be mitigated by hybrid friction damper. In this paper, various dependency tests were carried out to evaluate on the structural performance of two joint rotational friction component of the hybrid damper. Test results show that two joint rotational components do not depend on a displacement and a frequency of forcing but friction coefficients is reducing as a clamping force is increasing.

Strength of UD-Fabric Hybrid Laminated Composite Joints Based on Progressive Failure Analysis (점진적 파손해석 기법을 이용한 일방향-평직 혼합 적층 복합재 체결부의 강도)

  • 신소영;안현수;권진회
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.05a
    • /
    • pp.17-21
    • /
    • 2002
  • A finite element method based on the two-dimensional progressive failure analysis is presented for characterizing the strength and failure of the unidirectional-fabric hybrid laminated composite joints under pin loading. The 8-node laminated shell element is incorporated in the updated Lagrangian formulation. Various failure criteria including the maximum stress, Tsai-Wu, Yamada-Sun, and combinations of them are used in conjunction with the complete unloading stiffness degradation method. For the verification, joint tests are conducted for the specimens with various geometries. Although there are some differences depending on the geometry, the finite element model using the Yamada-Sun or the combined Yamada-Sun and Tsai-Wu criterion predicts the failure strength best.

  • PDF

Investigation of cure cycle for co-cured metal/composite hybrid structures without fabricating thermal residual stress (동시경화 하이브리드 금속/복합재료 구조물의 제조 잔류 열응력 제거를 위한 경화사이클에 관한 연구)

  • Kim Hak Sung;Park Sang Wook;Lee Dai Gil
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.10a
    • /
    • pp.83-87
    • /
    • 2004
  • In this work, the cure cycle of co-cured metal/composite structure was investigated to decrease fabricating thermal residual stresses between the metal and the composite material. DSC (Differential scanning calorimetry) experiment and static lap shear test of co-cured aluminum/composite double lap joint as well as the curvature experiment of co-cured steel/composite strip were performed to investigate the effect of curing cycle on the thermal residual stress of co-cured hybrid structures. From the experiments, it was found that post curing method after abrupt cooling of co-cured aluminum/composite hybrid structure at certain point of degree of cure during curing process could eliminate fabricating the thermal residual stresses.

  • PDF

Experimental Study on Shape Control of Smart Composite Structure with SMA actuators (SMA 작동기를 이용한 스마트 복합재 구조의 형상 제어에 관한 실험적 연구)

  • Yang Seung-Man;Roh Jin-Ho;Han Jae-Hung;Lee In
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.127-130
    • /
    • 2004
  • In this paper, active shape control of composite structure actuated by shape memory alloy (SMA) wires is presented. Hybrid composite structure was established by attaching SMA actuators on the surfaces of graphite/epoxy composite beam using bolt-joint connectors. SMA actuators were activated by phase transformation, which induced by temperature rising over austenite finish temperatures. In this paper, electrical resistive heating was applied to the hybrid composite structures to activate the SMA actuators. For faster and more accurate shape or deflection control of the hybrid composite structure, PID feedback controller was designed from numerical simulations and experimentally applied to the SMA actuators.

  • PDF

Optimal design of the co-cured aluminum/composite double lap joint (탄소섬유/에폭시 복합재료-알루미늄 양면겹치기 동시경화 조인트의 최적설계)

  • Park Sang Wook;Kim Hak Sung;Lee Dai Gil
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.10a
    • /
    • pp.78-82
    • /
    • 2004
  • The co-cured joint has been widely used in joining process of composite structures due to its simple and easy manufacturing process. In this paper, the effect of stacking sequence of the carbon epoxy prepreg, bonding length and thickness of the aluminum plate on the static tensile load capability of the co-cured aluminum-composite double lap joint were experimentally investigated. From experimental results, the optimum EA ratios with respect to stacking sequence and bonding length of the co-cured joint were obtained, which may be useful for the joining of hybrid structures.

  • PDF

Three-Dimensional Analysis of Composite External Fuel Tank Joint (항공기용 복합재 외부연료탱크 체결부의 3차원 구조해석)

  • Uhm Won-Seop;Jung Jae Woo;Kweon Jin-Hwe;Choi Jin-Ho;Yang Seung-Un;Lee Sang-Kwan
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.71-74
    • /
    • 2004
  • A composite-aluminum hybrid joint of composite external fuel tank of an aircraft has been analyzed by a 3-dimensional finite element method. Curvature and contact of the joint structure were considered in the analysis. Yamada-Sun failure criteria was utilized for the failure evaluation. A finite element program ABAQUS was used for the nonlinear contact analysis. The joint structure was predicted to be safe in both the test and analysis.

  • PDF

Three-dimensional contact analysis of a composite joint with unsymmetric boundary condition (비대칭 경계조건을 가지는 체결부의 3차원 접촉응력해석)

  • 장기정;박노회;안현수;권진회;최진호
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.110-113
    • /
    • 2002
  • As a preliminary study for the three dimensional failure analysis of composite joints, the three dimensional stress analysis on a pin-loaded unidirectional-fabric hybrid composite joints are performed. The contact and frictions between composite plate and metal bush are considered in the finite element method by NASTRAN. Experiments are conducted to validate the accuracy and feasibility of the finite element technique for 25 specimens with 5 different geometries. The finite element and experimental results show the bush cap induces the unsymmetric deformation, stress distribution, and failure behavior through the thickness. The experiment also shows the failure loads are higher in the joint with bush cap than without it.

  • PDF

A hybrid method for dynamic stiffness identification of bearing joint of high speed spindles

  • Zhao, Yongsheng;Zhang, Bingbing;An, Guoping;Liu, Zhifeng;Cai, Ligang
    • Structural Engineering and Mechanics
    • /
    • v.57 no.1
    • /
    • pp.141-159
    • /
    • 2016
  • Bearing joint dynamic parameter identification is crucial in modeling the high speed spindles for machining centers used to predict the stability and natural frequencies of high speed spindles. In this paper, a hybrid method is proposed to identify the dynamic stiffness of bearing joint for the high speed spindles. The hybrid method refers to the analytical approach and experimental method. The support stiffness of spindle shaft can be obtained by adopting receptance coupling substructure analysis method, which consists of series connected bearing and joint stiffness. The bearing stiffness is calculated based on the Hertz contact theory. According to the proposed series stiffness equation, the stiffness of bearing joint can be separated from the composite stiffness. Then, one can obtain the bearing joint stiffness fitting formulas and its variation law under different preload. An experimental set-up with variable preload spindle is developed and the experiment is provided for the validation of presented bearing joint stiffness identification method. The results show that the bearing joint significantly cuts down the support stiffness of the spindles, which can seriously affects the dynamic characteristic of the high speed spindles.

Fatigue Assessment of Hybrid Composite Joint for the Tilting Car Body (틸팅 차량용 차체의 하이브리드 복합재 접합체결부의 내구성 평가)

  • Jung, Dal-Woo;Choi, Nak-Sam;Kim, Jung-Seok;Seo, Sueng-Il;Jo, Se-Hyun
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2006.05a
    • /
    • pp.357-361
    • /
    • 2006
  • Fatigue fracture behavior of a hybrid joint part with bolting was evaluated in comparison to the case of static fracture. Hybrid joint part specimens for bending test were made with layers of CFRP and aluminum honeycomb. Characteristic fracture behaviors of those specimens were obviously different under static and cyclic loads. Static bending load showed the shear deformation at the honeycomb core, whereas cyclic bending load caused the delamination between CFRP skin layers and honeycomb core. Experimental results obtained by static and fatigue tests were considered in modifications of design parameters of the hybrid joint.

  • PDF