• Title/Summary/Keyword: Hwang Sung-Ha

Search Result 543, Processing Time 0.032 seconds

Development of a Stream Discharge Estimation Program (자연하천 유량산정 프로그램 개발)

  • Lee Sang Jin;Hwang Man Ha;Lee Bae Sung;Ko Ick Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.1
    • /
    • pp.27-38
    • /
    • 2006
  • In this study, we developed a program to estimate discharge efficiently considering major hydraulic characteristic including water level, river bed, water slope and roughness coefficient in a natural river. Stream discharge was measured at Gongju gauge station located in the down stream of the Daechung Dam during normal and dry seasons from 2003 to 2004. The developed model was compared with the results from the existing rating curve at T/M gage stations, and was used for runoff analyses. Evaluating the developed river discharge estimation program, it was applied during 1983-2004 that base flow separation method and RRFS (Rainfall Runoff Forecasting System) which is based on SSARR (Streamflow Synthesis And Resevoir Regulation). The result presents the stage-discharge curve creator range at the Gong-ju is overestimated by approximately $10-20\%$, especially at the low stage. It is attributed to the hydraulic characteristics at the study. The discharge simulated by the RRFS and base flow separation, which is calibrated using the measurement at the early spring and late fall season during relatively d]v season, shows the least errors. The coefficient of roughness at Gongju station varied with the high and low water level.

Early Diagnosis of Acute Hematogenous Osteomyelitis Using the Ultrasonography in a Child: A Case Report (초음파를 이용한 소아 급성 혈행성 골수염의 조기 진단: 증례보고)

  • Min, Kyoung-Dae;Ahn, Joong-Hyun;Cho, Woo-In;Hwang, Seok-Ha;Cho, Sang-Hyuck;Song, Sang-Hun;Lee, Byung-Ill
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.2
    • /
    • pp.76-80
    • /
    • 2013
  • It is very important to make an early diagnosis of acute hematogenous osteomyelitis in children to avoid various complications. We report a case of a five-year-old patient with tibial subperiosteal abscess, who was diagnosed using ultrasonography and treated at the early point of the disease.

  • PDF

A Novel Vertical Directional Coupler Switch with Switching Operation-Induced, Extinction Ratio-Adjusted, and Extinction Ratio-Enhanced Sections

  • Cho, Sung-Chan;Hong, Hyun-Ha;Yang, Choong-Reol;Choi, Jee-Yon;Kang, Min-Ho;Hwang, Hyun-Yong;Choi, Young-Woo;Kim, Hae-Geun;Jung, Byung-Min;Kim, Boo-Gyoun
    • ETRI Journal
    • /
    • v.24 no.2
    • /
    • pp.109-116
    • /
    • 2002
  • We propose a novel very short (< $300{\mu}m$) vertical directional coupler switch with high extinction ratios larger than 30 dB. The device consists of a switching operation induced section (SOIS), an extinction ratio adjusted section (ERAS), and an extinction ratio enhanced section (ERES). These are achieved by changing the refractive index of one core. The switching operation is induced by changing the refractive index of one core in the SOIS. The improvement of extinction ratios larger than 30 dB for both the cross and bar states is made by controlling the asymmetry of the refractive indices of both cores in the ERES. Through the ERAS, different extinction ratios between the cross and bar states at the end of the SOIS are changed to the same value. For this reason, the optimum asymmetry of the refractive indices of the cores for the maximum extinction ratios and the lengths of ERES are the same for cross and bar states. Design guidelines for high extinction ratios with large tolerances are presented.

  • PDF

Long-term load cycle test of the HTS cable system (초전도케이블의 장기 부하변동시험 및 성능평가)

  • Lim, Ji-Hyun;Sohn, Song-Ho;Yim, Seong-Woo;Sung, Tae-Hyun;Hwang, Si-Dole;Choi, Ha-Ok;Yang, Hyung-Suk;Ma, Yong-Hu;Ryu, K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.300-300
    • /
    • 2008
  • 우리나라의 전기에너지 수요가 지속적으로 증가함에 따라 새로운 송배전 선로의 구축이 필요하다. 하지만 현재 도심지의 전력구에는 더 이상의 지중선의 증설은 불가능하며 가공선 설치의 경우 환경 민원의 부담을 떠안게 된다. 그래서 기존 동도체의 회선당 송전 한계를 극복하고 대용량 송전 및 손실을 크게 줄일 수 있는 초전도 케이블의 연구가 세계적으로 활발히 진행되고 있다. 한국전력 전력연구원은 신 전력시스템으로서의 22.9 kV급 초전도케이블 시스템을 고창전력시험센터에 설치하고 운영 및 유지 보수 과정을 통하여 실제 계통 적용을 위한 최적 운전조건을 연구하고 있다. 이 논문에서는 실제 부하 상황을 모의하기 위하여 초전도케이블의 장기 부하변동 시험에 따른 케이블 송전 능력 확인 및 냉각시스템의 반응성을 살펴보고 부하변동 시험 후 초전도케이블 도체 열화 여부를 확인하기 위하여 직류 임계전류를 측정하였다. 그 결과 부하변동 시험 전의 임계전류 값과의 변화율이 삼상 모두 ${\pm}1$% 내외로서 오차범위를 벗어나지 않으므로 건전한 것으로 판단되었다.

  • PDF

A Study on a Methodology of Determining an Appropriate Load Power Factor Effectively by the Use of Reactive Power Sensitivity and Load Duration Curve (무효전력 민감도와 부하지속곡선을 활용한 적정 부하역률의 효과적인 산정 기법에 관한 연구)

  • Lee, Byung Ha;Hwang, Sung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1782-1790
    • /
    • 2012
  • In this paper, a methodology to use load duration curve and the reactive power factor sensitivity of generation cost is proposed for analyzing the effects of load power factor effectively. A great deal of cases of power systems are classified into several patterns according to the characteristics using load duration curve, and the overall effects of load power factor are assessed by integrating the analysis results of load power factor in all the patterns. The reactive power sensitivity of generation cost and the integrated costs such as generation cost, investment cost, voltage variation penalty cost and CO2 emission cost are used for determining an appropriate load power factor. A systematic procedure for effective analysis of load power factor is presented. It is shown through the application to the practical power system of KEPCO(Korea Electric Power Corporation)that the effects of load power factor can be analyzed effectively using load duration curve and reactive power factor sensitivity.

Development of GIS-based Regional Crime Prevention Index to Support Crime Prevention Activities in Urban Environments

  • Seok, Sang-Muk;Kwon, Hoe-Yun;Song, Ki-Sung;Lee, Ha-Kyung;Hwang, Jung-Rae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.1
    • /
    • pp.41-48
    • /
    • 2017
  • In this study, we proposed GIS-based Regional Crime Prevention Index (RCPI) development method designed to support local governments with systematic crime prevention activities. The public interest in safe urban environment is increasing rapidly. The government is putting efforts into crime prevention activities to eliminate the criminal opportunities in advance. CPTED is method to prevent crimes in the city by improving environmental factors that cause crime. It is used by local governments to promote the crime prevention activities centering on the expansion of CCTVs and street lamps and the improvement of street environment. However, most policies were terminated as one-off programs and it is necessary to monitor the effect of such policies on a continuous basis. In order to alleviate issues, this study proposed RCPI as part of crime safety assessment in urban environments. The estimation of RCPI in City A of Gyeonggi-do showed relative differences in 31 districts (dong), indicating that it is also possible to evaluate the crime safety in the local community on the level of the administrative dong, the smallest administrative district in the urban environments. As a crime map, the RCPI will be used effectively as he reference to support the decision making process for local government in the future.

Antitumor Effects and Immunomodulating Activities of Phellinus linteus Extract in a CT-26 Cell-Injected Colon Cancer Mouse Model

  • Yang, Byung-Keun;Hwang, Seung-Lark;Yun, Ik-Jin;Do, Eun-Ju;Lee, Won-Ha;Jung, Young-Mi;Hong, Sung-Chang;Park, Dong-Chan
    • Mycobiology
    • /
    • v.37 no.2
    • /
    • pp.128-132
    • /
    • 2009
  • The antitumor effects of Phellinus linteus extract (Keumsa Linteusan) were investigated in a CT-26 cell-injected colon cancer mouse model. When administered orally (250${\sim}$1,000 mg/kg body weight), Keumsa Linteusan significantly inhibited the growth of solid colon cancer. The highest dose was highly effective, reducing tumor formation by 26% compared with the control group. The anticomplementary activity of Keumsa Linteusan increased in a dose-dependent manner. Lysosomal enzyme activity of macrophages was increased by 2-fold (100 ${\mu}$/ml) compared with the control group. Keumsa Linteusan can be regarded as a potent enhancer of the innate immune response, and can be considered as a very promising candidate for antitumor action.

Effect of DW282 on the Induction of Methemoglobinemia, Hypoglycemia or WBC Count and Hematological Changes

  • Moon, Eun-Yi;Hwang, Hyun-Sook;Choi, Chung-Ha;Jung, Sang-Hun;Yoon, Sung-June
    • Archives of Pharmacal Research
    • /
    • v.22 no.6
    • /
    • pp.565-570
    • /
    • 1999
  • DW2282,(S)-(+)-4-phenyl-1-[1-(4-aminobenzoyl)-indoline-5-sulfonyl]-4,5-dihydro-2-imidazolone hydrochloride, is a new anticancer agent which is thought to exhibit a characteristic mechanism of action in the inhibition of tumor growth. In this study, we estimated the toxicities of DW2282 in mice. When mice were orally dosed for five consecutive days at the dosages of 50, 100 and 150 mg/kg, DW2282 did not induced methemoglobinemia and hypoglycemia at any of these doses. However, increased ALT and AST values were observed in the 150 mg/kg dosing group, and white blood cells (WBC) were significantly decreased at all doses. However, the changes in WBC count, ALT and AST immediately reversed after the cessation of drug administration. In addition, we found that DW2282 did not cause an increase in hemolysis in human blood. Taken together, these data suggested that DW2282 may have a relatively low level of toxicity, and that there may be a quick recovery from any toxicity it dose produce.

  • PDF

A Study on an Algorithm of Line Switching and Bus Separation for Alleviating Overloads by the Use of Line Power Tracing and Sensitivity (선로유효전력 Tracing과 민감도를 활용한 선로 과부하 해소 스위칭 및 모선분리 알고리즘에 관한 연구)

  • Lee, Byung-Ha;Hwang, Sung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.11
    • /
    • pp.2007-2016
    • /
    • 2011
  • In this paper, a new algorithm for alleviating overloads in power networks by the use of line power tracing and sensitivity is proposed to perform line switching and bus separation effectively. Also, a new bus separation index based on line power tracing is presented to find the bus to be separated for relieving overloads effectively. By applying the sensitivity of the line flow with respect to the change of the line impedance, both switching-on and switching-off of the lines for alleviating overloads in power networks are performed systematically at once. The number of the considered cases for line switching and bus separation can be greatly reduced and the best combination of line switching and bus separation can be acquired efficiently by the use of the sensitivity and the bus separation index. In order to show the effects of this algorithm, it is applied to a small scale power system of IEEE 39-bus system and practical power systems of KEPCO.

Detection and Classification of Demagnetization and Short-Circuited Turns in Permanent Magnet Synchronous Motors

  • Youn, Young-Woo;Hwang, Don-Ha;Song, Sung-ju;Kim, Yong-Hwa
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1614-1622
    • /
    • 2018
  • The research related to fault diagnosis in permanent magnet synchronous motors (PMSMs) has attracted considerable attention in recent years because various faults such as permanent magnet demagnetization and short-circuited turns can occur and result in unexpected failure of motor related system. Several conventional current and back electromotive force (BEMF) analysis techniques were proposed to detect certain faults in PMSMs; however, they generally deal with a single fault only. On the contrary, cases of multiple faults are common in PMSMs. We propose a fault diagnosis method for PMSMs with single and multiple combined faults. Our method uses three phase BEMF voltages based on the fast Fourier transform (FFT), support vector machine(SVM), and visualization tools for identifying fault types and severities in PMSMs. Principal component analysis (PCA) and t-distributed stochastic neighbor embedding (t-SNE) are used to visualize the high-dimensional data into two-dimensional space. Experimental results show good visualization performance and high classification accuracy to identify fault types and severities for single and multiple faults in PMSMs.