• Title/Summary/Keyword: Humidity stability

Search Result 261, Processing Time 0.028 seconds

A Study on the Application of the Dehumidification System for Radiant Floor Cooling Using Ondol (온돌을 이용한 바닥복사냉방의 제습시스템 적용에 관한 연구)

  • 임재한;여명석;양인호;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.7
    • /
    • pp.607-616
    • /
    • 2002
  • This study has been conducted to evaluate the applicability of the control method in the dehumidification-integrated radiant floor cooling system in terms of stability of the room air temperature and the control variables through experiments. To do this, the relationship between the control variables in preventing floor surface condensation is first analyzed and the control method is predetermined through simulations. The results are as follows. First, it is necessary to determine the operation status of the dehumidification system according to the relationship between floor surface temperature and dew point temperature in the conditioned space. Second, outdoor reset with indoor temperature feedback control is better than on/off bang-bang control with respect to temperature stability in controlling the room air temperature and the possibility of energy savings. Finally, the humidity sensor can be located with the current thermostat in that there are small differences in absolute humidity in vertical distribution.

Capacitive Humidity Sensor Using Reactive Methacrylate Copolymers (반응성이 있는 메타크릴레이트 공중합체를 이용한 정전용량형 습도센서)

  • 공명선;이임렬
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.4
    • /
    • pp.21-27
    • /
    • 2003
  • The copolymers with various composition of methyl methacrylate (MMA), ethyl methacrylate (EMA), methacrylic acid (MA) and hydroxyethyl methacrylate (HEMA) were synthesized for capacitive humidity sensitive materials. The capacitive humidity sensor consisted of a polymethacrylate film coated on both sides with gold electrode. Capacitance versus relative humidity increased with HEMA content in the copolymer. In the case of self-crosslinkable MMA/MA/HEHA= 40/10/10, the average capacitance at 30%RH, 60%RH and 90%RH are 102, 134 and 166 pF, respectively. And also, the hysteresis, temperature cycle and long-term stability were evaluated as a capacitance humidity sensor.

  • PDF

A Capacitive Type Humidity Sensor Using a Polyimide Film for Hermeticity Measurement of Micro Packages (마이크로 패키지의 밀폐도 측정을 위한 정전용량형 폴리이미드 습도센서)

  • Kim, Yong-Ho;Kim, Yong-Jun;Kim, Kyung-Il;Kim, Joong-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.287-291
    • /
    • 2004
  • A capacitive type humidity sensor has been fabricated using a polyimide film without hydrophobic elements and its characteristics has been evaluated for hermeticity measurement of micro packages. For a highly sensitive humidity sensor, a polyimide film without hydrophobic elements has been synthesized and used instead of using a commercial one in which 7 group elements such as fluorine or chlorine are included. Sensitivity, stability and hysteresis has been performed to characterize the fabricated sensors. The sensitivity defined as normalized percent capacitance change was 0.3751%RH and hysteresis was 0.77% in the range of 10%RH to 90%RH. Maximum deviation from the average capacitance measured for 120 minutes at 50%RH was 0.25%. The proposed humidity sensor can be used for hermeticity measurement of micro packages.

A Study on the Fabrication of Laser-Induced Graphene Humidity Sensor for Mounting on a Disposable Mask (일회용 마스크에 장착을 위한 레이저 기반 그래핀 습도센서 제작에 관한 연구)

  • Lee, Jun-Uk;Shin, Yun-Ji;Yang, Hye-Jeong;Shin, Bo-Sung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.4_2
    • /
    • pp.693-699
    • /
    • 2020
  • 355nm UV pulse laser is irradiated on the surface of polyimide (PI) by LDW (Laser Direct Writing) method to produce a high sensitivity flexible humidity sensor using a simple one-step process. The LDW method continuously investigates 2-D CAD data using a galvano scanner and an F-lens. This method is non-contact, so it minimizes physical strain on the PI. Laser-induced graphene (LIG) produced by lasers has a high surface area due to its high flexibility and numerous pores and oxidizers compared to conductors. For this reason, it is highly useful as a flexible humidity sensor. The humidity sensor produced in this study was attached to the inside of a mask filter, which has become a hot topic recently, and its applicability was confirmed.The measurement of humidity measured the sensitivity, reactivity, stability and recovery behavior of the sensor by measuring changes in capacitance and resistance.

Effect of $Li_2O$ and $Na_2O$ addition on the microstructure and humidity sensitivity of $V_ 2O_5$-doped $TiO_2$ ($V_2O_5$를 도판트한 $TiO_2$의 미세구조와 감습에 미치는 알카리 옥사이드$ M_2O(M=Li,Na)$의 영향)

  • 신용덕
    • Electrical & Electronic Materials
    • /
    • v.9 no.6
    • /
    • pp.605-615
    • /
    • 1996
  • In this paper, the effect of alkaline oxide addition such as Li$_{2}$O and Na$_{2}$O on the microstructure and humidity sensitivity of V$_{2}$O$_{5}$(2 mol%)-doped TiO$_{2}$(98 mol%) was investigated as a function of amount (0, 1, 2, 5, 10 mol%) of Li$_{2}$O and Na$_{2}$O additives. The pores in the alkaline free sample were distributed mostly in the range between 0.16 and 1.0.mu.m in diameter and its porosity was 23.29%. Li$_{2}$O caused grain overgrowth and reduced the porosity with a narrow distribution of the pore size, leading to poor humidity sensitivity. Na$_{2}$O helped to enlarge the distribution of the pore size through the formation of small soluble phases. The pore sizes of the sample containing Na$_{2}$O 2mol% were distributed mostly in the range between 1.0 and 2.5.mu.m in diameter and its porosity and intrusion volume of mercury were 31.13 % and 0.1155 mL/g respectively, which consequently improved the humidity sensing characteristics such as the sensitivity and temperature-stability. Especially, the addition of 2mol% of Na$_{2}$O improved the humidity-sensing characteristics such as sensitivity and linearity in the whole range between 30 and 90 %RH (Percentage Relative Humidity)y)

  • PDF

The Effect of Sealing Technology on the Long-Term Stability of Dye-Sensitized Solar Cell Module (염료감응 태양전지 모듈의 장기안정성 향상을 위한 실링기술 연구)

  • Lee, Kwangsoo;Ko, Min Jae
    • Current Photovoltaic Research
    • /
    • v.4 no.4
    • /
    • pp.155-158
    • /
    • 2016
  • Long-term stability of dye-sensitized solar cell (DSSC) module is critical for the commercialization. We investigated the effect of sealing technology on the long-term stability of the $10cm{\times}11cm$ sized DSSC modules. We applied the concept of secondary sealing to the module and then performed several stability tests such as humidity cycle, 1 sun light soaking and outdoor stability tests. The enhanced stability was confirmed for the DSSC module employing optimized sealing materials and architectures.

Effects of Temperature and Relative Humidity on Water Soluble Vitamin Contents in Commercial Vitamin Tablet (저장 온도 및 상대습도가 비타민 정제 중 수용성 비타민 함량의 변화에 미치는 영향)

  • Lee, Jae-Hwang;Kim, Sae-Gon;Lee, Dong-Un;Park, Seok-Jun;Lee, Jin-Hee;Lee, Kang-Pyo;Kim, Dong-Seob;Choi, Sung-Won;Baik, Moo-Yeol
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.6
    • /
    • pp.1028-1034
    • /
    • 2005
  • Effects of temperature and relative humidity on contents of water-soluble vitamins (vitamins $B_1,\;B_2,\;B_3,\;B_6$, and C) of two commercial tablets ("Multivitamin Dandelion" and "Chewable vitamin C") were investigated. When stored at various temperatures (25, 35, and $45^{\circ}C$) with cap, all measured vitamins were stable and degraded very slowly during 24 weeks of storage; low relative humidity (11% RH) without cap also provided stability during storage period. At higher relative humidities (75 and 100% RH), contents of all water-soluble vitamins, except vitamins $B_2\;and\;B_3$, decreased significantly at early storage period. These results showed that stability of water-soluble vitamins is highly dependent on relative humidity rather than storage temperature.

Nonlocal strain gradient model for thermal stability of FG nanoplates integrated with piezoelectric layers

  • Karami, Behrouz;Shahsavari, Davood
    • Smart Structures and Systems
    • /
    • v.23 no.3
    • /
    • pp.215-225
    • /
    • 2019
  • In the present paper, the nonlocal strain gradient refined model is used to study the thermal stability of sandwich nanoplates integrated with piezoelectric layers for the first time. The influence of Kerr elastic foundation is also studied. The present model incorporates two small-scale coefficients to examine the size-dependent thermal stability response. Elastic properties of nanoplate made of functionally graded materials (FGMs) are supposed to vary through the thickness direction and are estimated employing a modified power-law rule in which the porosity with even type of distribution is approximated. The governing differential equations of embedded sandwich piezoelectric porous nanoplates under hygrothermal loading are derived through Hamilton's principle where the Galerkin method is applied to solve the stability problem of the nanoplates with simply-supported edges. It is indicated that the thermal stability characteristics of the porous nanoplates are obviously influenced by the porosity volume fraction and material variation, nonlocal parameter, strain gradient parameter, geometry of the nanoplate, external voltage, temperature and humidity variations, and elastic foundation parameters.

Effect of $M_2CO_3$(M=Li, K) Addition on the Humidity Sensitivity of $V_2O_5$-doped $TiO_2$ ($V_2O_5$를 dopant로 한 $TiO_2$의 감습(感濕)에 미치는 $M_2CO_3$(M=Li, K)의 영향(影響))

  • Kang, Yi-Kug;Song, Chang-Yul;Shin, Yeong-Duck
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.427-429
    • /
    • 1995
  • In this paper, the effect of alkaline oxides on the humidity sensitivity of $V_2O_5$(2mol%)-doped $TiO_2$(98mol%) was investigated as functions of $Li_2CO_3$, $K_2CO_3$, additives (x= 0.0 mol%, 1mol%, 2mol%, 5mol%, 10mol%). 1. The porosity and total intrusion volume of sample containing 1, 2, 5mol% $K_2O$ was increased, and then those of 10mol% $K_2O$ was reduced again. 2. The humidity sensitivity of samples containing 1, 2, 5, 10mol% $K_2O$ were good generally. Especially the sample containing 5mol% $K_2O$ were the better. 3. the stability of the humidity sensitivity of samples containing $K_2O$ at low and high temperatures is very good.

  • PDF

Computational Fluid Dynamics Study on Performance Variation of PEMFC with Serpentine Flow Fields According to Humidity Condition (가습조건이 사형유로를 채택한 고분자 전해질 연료전지의 성능에 미치는 영향에 대한 전산유체역학 해석 연구)

  • Oh, Gyu-Hwan;Lee, Kyu-Jin;Nam, Jin-Hyun;Kim, Charn-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.8
    • /
    • pp.604-612
    • /
    • 2009
  • Water management has been recognized as a crucial factor for achieving better performance and stability in polymer electrolyte membrane fuel cells (PEMFCs). Proper water management should provide favorable water conditions, including the local humidity, membrane water content, and liquid water saturation in PEMFCs, thereby leading to more uniform electrochemical reaction and current generation. In this study, computational fluid dynamics (CFD) simulation was conducted to investigate the effects of the cathode relative humidity (RH) on the performance of a 3 by $3\;cm^2$ PEMFC with serpentine flow fields. The CFD results showed that the best performance of the PEMFC was obtained for the cathode RH of 80%, but the performance variation was small for the cathode RH range of $60{\sim}100%$. However, the loss of the PEMFC performance was significant when the cathode RH was reduced below 40%. The reason for such performance variation was investigated through the detailed inspection of ohmic loss, activation and concentration overpotential, and water and current distributions.