• Title/Summary/Keyword: Humidity ratio

Search Result 512, Processing Time 0.031 seconds

Study on the Storage of Chestnut (밤 저장(貯藏)에 관(關)한 연구(硏究))

  • Choi, Jong Uck;Lee, Joo Baek;Sohn, Tae Hwa
    • Current Research on Agriculture and Life Sciences
    • /
    • v.3
    • /
    • pp.99-104
    • /
    • 1985
  • This research was carried out study the effect of several relative humidities on the cracking of kernels of chestnuts. The moisture contents of total kernel increased at the higher humidity over 88% relative humidity. but the moisture contents of inner layer was decreased at low relative humidity below 76 %. The starch contents of kernel decreased, but free stgars increased during the total period of storage. The tannin contents increased during total of storage, and the tannin contents of out layer was higher than inner layer because of tannin transfer from astringent shell. As we considered the sprouting ratio, the rotting ratio and the cracking ratio, the optimal relative humidity of chestnut storage was proved 88% relative humidity.

  • PDF

Evaluation of Electrospun TiO2/PVP/LiCl Nanofiber Array for Humidity Sensing (전기방사를 이용한 TiO2/PVP/LiCl 나노섬유 습도 센서의 제작과 평가)

  • Ryu, Hyobong;Kim, Bumjoo;Kwon, Hyukjin Jean;Heo, Joonseong;Lim, Geunbae
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.42-45
    • /
    • 2014
  • Recently, tremendous application utilizing electrospun nanofibers have been actively reported due to its several advantages, such as high surface to volume ratio, simple fabrication and high-throughput manufacturing. In this paper, we developed highly sensitive and consistent nanofiber humidity sensor by electrospinning. The humidity sensor was fabricated by rapid electrospinning (~2 sec) $TiO_2$/PVP/LiCl mixed solution on the micro-interdigitated electrode. In order to evaluate the humidity sensing performances, we measured current response using DC bias voltage under various relative humidity levels. The results show fast response / recovery time and marginal hysteresis as well as long-term stability. In addition, with the aid of micro-interdigitated electrode, we can reduce a total resistance of the sensor and increase the total reaction area of nanofibers across the electrodes resulting in high sensitivity and enhanced current level. Therefore, we expect that the electrospun nanofiber array for humidity sensor can be feasible and promising for diverse humidity sensing application.

Effect of inlet air humidity on the combustion process of the spark-ignition engine (흡입습도가 스파아크 점화기관의 연소과정에 미치는 영향)

  • 김문헌;이성열
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.5 no.2
    • /
    • pp.41-47
    • /
    • 1983
  • The analysis shows that the variation of maximum pressure of the cycle, rate of hear release, rate of mass burned, and combustion delay are influenced by the inlet air humidity in the spark-ignition engine. The quantitative combustion delay can be obtained from the rate of mass burned. Also, the variation of time loss and effective compression ratio with the change of inlet air humidity are dominated by the development of rate of heat release.

  • PDF

Performance of Differential Field Effect Transistors with Porous Gate Metal for Humidity Sensors

  • Lee, Sung-Pil;Chowdhury, Shaestagir
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.6
    • /
    • pp.434-439
    • /
    • 1999
  • Differential field effect transistors with double gate metal for integrated humidity sensors have been fabricated and the drain current drift characteristics to relative humidity have been investigated. The aspect ratio was 250/50 for both transistors to get the current difference between the sensing device and non-sensing one. The normalized drain current of the fabricated humidity sensitive field effect transistors increases from 0.12 to 0.3, as relative humidity increases from 30% to 90%.

  • PDF

Dynamic Simulation of a Dedicated Outdoor Air-conditioning System (외기 전용 공조기의 동특성 시뮬레이션)

  • Kim, Jung-Min;Kim, Young-Il;Chung, Kwang-Seop;Park, Seung-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.322-327
    • /
    • 2007
  • Dedicated outdoor air-conditioning(DOA) system that utilizes pre-cooling and desiccant dehumidification can be superior to conventional cooling and reheating system with respect to energy consumption and indoor thermal comfort. In this work, simulation has been conducted to study various factors that affect the performance of DOA. Dynamic simulation shows the transient variation of temperature and humidity as the on/off control logic is imposed. Exit humidity of process air and flow rate are varied to study the effect on exit temperature of process air, dehumidification quantity, required regeneration temperature and exit humidity of regeneration air. For an outdoor air condition of $28.5^{\circ}C$ temperature, 16 g/kg humidity ratio and 2000 cmh flow rate, the dehumidification efficiency is increased by 4.6% as the flow rate is doubled.

  • PDF

A Study on Modelling for Prediction of Concrete Drying Shrinkage according to Aggregate Ratio of Concrete (잔골재율 변화에 따른 콘크리트 건조수축 모델링에 관한 연구)

  • Park, Do-kyong;Yoon, Yer-Wan;Kim, Kwang-Seo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.4
    • /
    • pp.71-77
    • /
    • 2004
  • Drying Shrinkage has much complexity as it has relations with both internal elements of concrete and external factors. Therefore, experiments on Concrete Drying Shrinkage are carried out in this study under simplified circumstances applying temperature & Humidity test chamber which enables constant temperature and humidity. Comparative analyses have been made respectively according to the consequences aiming at modelling for prediction of Concrete Drying Shrinkage and making out measures to reduce it. Strain Rate of Drying Shrinkage of concrete under the condition of dry air appears to rise by about 20%-30% in proportion as the temperature rises $5^{\circ}C$ when the humidity was held below 10% compared under the condition of dry temperature & Humidity test chamber. Strain Rate of Drying Shrinkage in pit sand concrete increased 20% higher than measured when in river sand under the condition of 90-day material age. A general formula with two variables is derived as follow ${\varepsilon}={\alpha}_1+{\beta}_1x_1+{\beta}_2x_2+{\beta}_3x_1^2+{\beta}_5x_2^2$. and also graphed in 3 dimensions, enabling to apply to actual design and predict Strain Rate of Drying Shrinkage in concrete. The results of prediction of Rate of Drying Shrinkage by Response Surface Analysis are as follows. The coefficient of correlation of Drying Shrinkage in Concrete was over 90%.

Performance Analysis of a Wet Air-Cycle Refrigeration System (습공기사이클 냉동시스템의 성능해석)

  • Won, Sung Pil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.11
    • /
    • pp.504-511
    • /
    • 2014
  • The objective of this study is to theoretically analyze the performance of an open wet air-cycle refrigeration system, which nowadays is increasingly generating environmental concern. The temperature and relative humidity of the outside air are selected as the most important parameters. As the temperature and relative humidity of the outside air increase, the pressure ratio of the ACM compressor is determined to be nearly constant, the air temperature at the exit of the system increases, and the amount of condensed water, the cooling capacity, the COP, and the total entropy production rate increase overall. The effects of the effectiveness of the heat exchanger and the efficiency of the turbine on the performance are greater than that of the efficiency of the ACM compressor. Also, the performance of the wet air-cycle refrigeration system with two heat exchangers is enhanced, with a high COP and low total entropy production rate, compared to the system with a single heat exchanger.

The Experimental Study on $CO_2$ Diffusivity in Concrete (콘크리트 중으로의 $CO_2$ 확산에 관한 실험연구)

  • 오병환;정상화;이명규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.163-168
    • /
    • 2002
  • Through the developing measuring system of gas diffusivity, the experiments on carbon dioxide diffusivity in concrete carry out. From this, some important results was achieved. First, the times of reaching the steady state condition don't depend on the water/cement ratio with linearity. But, for the 0.42 w/c ratio the duration of the non-steady state condition is long. Second, in constant relative humidity, the diffusion coefficient shows linearity for the w/c ratio. Third, for the same w/c ratio, the influence of relative humidity on the diffusivity is very large. This shows the importance of the environmental condition for the carbonation. This study on $CO_2$ diffusivity in concrete is the first attempt within a country and will be important data.

  • PDF

Cloud Forecast using Numerical Weather Prediction (수치 예보를 이용한 구름 예보)

  • Kim, Young-Chul
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.15 no.3
    • /
    • pp.57-62
    • /
    • 2007
  • In this paper, we attempted to produce the cloud forecast that use the numerical weather prediction(NWP) MM5 for objective cloud forecast. We presented two methods for cloud forecast. One of them used total cloud mixing ratio registered to sum(synthesis) of cloud-water and cloud-ice grain mixing ratio those are variables related to cloud among NWP result data and the other method that used relative humidity. An experiment was carried out period from 23th to 24th July 2004. According to the sequence of comparing the derived cloud forecast data with the observed value, it was indicated that both of those have a practical use possibility as cloud forecast method. Specially in this Case study, cloud forecast method that use total cloud mixing ratio indicated good forecast availability to forecast of the low level clouds as well as middle and high level clouds.

  • PDF

Effect of Relative Humidity and Temperature on the Compression Strength of Corrugated Boxes on Distribution Channel (유통중 온습도 변화에 따른 골판지 상자의 압축강도에 대한 연구)

  • 이명훈;김종경
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.35 no.2
    • /
    • pp.33-38
    • /
    • 2003
  • In order to design the high strength corrugated fiberboard containers for agricultural products that can be used for the cold chain system, a large number of individual boxes were placed in various humidity environments at two different temperature of 5 and $20^{\circ}C$. The results indicated that temperature changes do not effect on physical strength of corrugated fiberboard containers as much as humidity changes did. The main conclusion from this study was that compression strength of corrugated fiberboard containers dropped significantly at high humidity condition, but the rates varied depending on the number of walls, temperature, and perimeter of containers. The packaging designer must consider the corrugated fiberboard boxes are also greatly affected by dimensional variations such as the length versus width ratio. Based on this study, water-resistant board would not be necessary if the ambient relative humidity does not reach to a critical point, 85 percent in the cold chain system. However, the designer must count for the unexpected fluctuation of rotative humidity resulting in severe loss of the compression strength of corrugated fiberboard container.