• 제목/요약/키워드: Humidity ratio

검색결과 512건 처리시간 0.028초

적정수분 관리를 위한 담배흡습속도에 관한 연구 (Studies on Absorption Ratio of Tobacco for Optimum Moisture Control)

  • 정한주;김기환;민영근;김병구;양광규;오인혁
    • 한국연초학회지
    • /
    • 제15권1호
    • /
    • pp.90-97
    • /
    • 1993
  • 1. Average moisture content of tobacco in BIB silo was about 19: 1% until 4hours conditioned time, and then moisture variation of tobacco after 2hr conditioned was very small. 2. Application of mathematical model for ordering system. 1) The constant K in the exponential equation varies inversely with both relative humidity and equilibrium moisture. 2) Time needed to order blending tobacco leaves with standard moisture from bulking and blending silo was 4 hours. 3) Reconstituted tobacco sheet had higher moisture absorption ratio than Oriental and Burley tobacco. 4) For minimize of conditioning time in BIB silo, the values of K and Mo given in this study can be used in equation(1) to calculate moisture absorption ratio and optimum conditioning time. 3. Average moisture content and water activity of conditioned tobacco for 4 hours in BIB silo was about 20% and 0.65. In this condition. microbial life will inhibite 4. Physical properties of conditioned tobacco in bulking and blending silo for 4hours was virtually no change.

  • PDF

잔향실법 흡음률 측정에 미치는 확산체의 영향 (The effect of diffusers on the measurement of sound absorption in a reverberation room)

  • 한희갑;김경호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1194-1197
    • /
    • 2006
  • Recently, international standard for measurement of sound absorption in a reverberation room has been amended. In the revised version, temperature, humidity and air pressure conditions are strictly restricted and also the concrete procedures are presented to reduce the differences in test results by adding inspection of diffusion, measurement uncertainty etc. In this paper, the systematic tests are conducted based on the inspection guide of diffusion defined by ISO 354 and the effects of diffusers on the measurement of sound absorption ratio are considered. As a result, we perceived that the averaged sound absorption ratio in mid and high frequency range is expected to measure around $0.05{\sim}0.1$ higher in high sound absorption material. Therefore, as for the reverberation room for measurement of sound absorption, we need to take into consideration not only the spatial standard deviation of sound pressure mandated by ISO 3741, but also, inspection regulation of diffusion showed by ISO 354.

  • PDF

연소시험법에 의한 산화성물질의 위험성 평가 (Risk Evaluation of Oxidizing Substances by Burning Test Method)

  • 정국삼
    • 한국안전학회지
    • /
    • 제7권3호
    • /
    • pp.73-82
    • /
    • 1992
  • This paper was concerned with the risk evaluation of oxidizing substances by burning test method. The samples were prepared the heaped cone-shaped mixtures of solid oxidizing sub-stance with sawdust, and ignition of the sample was made on contact with heating wire inside the combution chamber that the temperature and humidity of atmosphere can be kept at $25^{\circ}C$ and 60% respectively. Accordingly, it were measured the combustivity effect of mixing ratio and amount of sample weight on the burning rate. As a result of burning test of these samples, it could be noticed that the case when the sawdust has so and 30 wt.% in the mixing ratio shows effective combustivity, and as the amount of sample weight was increasing, It showed more rapid burning time. So the average burning time could be obtained by considering the weighting factors to the parameters of the mixing ratio and the amount of sample weight. Finally, it was compared with the effects of cation and anion of oxidizing substances and also applied analytically to the classification and evaluation of oxidizing sub-stances as dangerous goods.

  • PDF

플라즈마 실리콘 OXYNITRIDE막의 구조적 특성에 관한 고찰 (A Study on the Structure Properties of Plasma Silicon Oxynitride Film)

  • 성영권;이철진;최복길
    • 대한전기학회논문지
    • /
    • 제41권5호
    • /
    • pp.483-491
    • /
    • 1992
  • Plasma silicon oxynitride film has been applied as a final passivation layer for semiconductor devices, because it has high resistance to humidity and prevents from alkali ion's penetration, and has low film stress. Structure properties of plasma silicon oxynitride film have been studied experimentally by the use of FT-IR, AES, stress gauge and ellipsometry. In this experiment,Si-N bonds increase as NS12TO/(NS12TO+NHS13T) gas ratio increases. Peaks of Si-N bond, Si-H bond and N-H bond were shifted to high wavenumber according to NS12TO/(NS12TO+NHS13T) gas ratio increase. Absorption peaks of Si-H bond were decreased by furnace anneal at 90$0^{\circ}C$. The atomic composition of film represents that oxygen atoms increase as NS12TO/(NS12TO+NHS13T) gas ratio increases, to the contrary, nitrogen atoms decrease.

  • PDF

Nano-Silica effect on the physicomechanical properties of geopolymer composites

  • Khater, H.M.
    • Advances in nano research
    • /
    • 제4권3호
    • /
    • pp.181-195
    • /
    • 2016
  • Addition of nano-$SiO_2$ (NS) to geopolymer composites has been studied through measurement of compressive strengths, FTIR and XRD analysis. Alumino-silicate materials are coarse aggregate included waste concrete and demolished walls with its cementing binder, cement kiln dust (CKD) used and can possess a pronouncing activation for the geopolymer reaction resulting from the high alkali contents within. Materials prepared at water/binder ratios in a range of 0.30: 0.40 under curing of $40^{\circ}C$ and 100% Relative Humidity (R.H.), while the used activator is sodium hydroxide in the ratio of 2 wt. %. First, CKD is added in the ratio from 10 up to 50 wt., %, and the demolished walls was varied depending on the used CKD content, while using constant ratio of waste concrete (40 wt., %). Second step, depending on the optimum CKD ratio resulted from the first one (40 wt. %), so the control geopolymer mix composed of cement kiln dust, demolished walls and waste concrete in the ratio (40:20:40, wt %). Nano-silica partially replaced waste concrete by 1 up to 8%. Results indicated that, compressive strengths of geopolymer mixes incorporating nano-silica were obviously higher than those control one, especially at early ages and specially with 3%NS.

콘크리트 코어 압축강도의 각종 영향인자 보정 (Correction of Various Testing Factors Affecting Measured Compressive Strength of Concrete Core)

  • 박석균;최욱;오광진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.973-978
    • /
    • 2002
  • This study was performed to verify the effect of various testing conditions affecting measured compressive strength of concrete core and to compute the correction coefficients for it. Conditions of specimens affecting test results include size(diameter), height-diameter ratio, humidity of specimen, amount and arrangement of bar, core direction from structure and method of end preparation. In testing core strength of concrete, special cares should be taken on various testing conditions whose effects have been latent in conventional concrete.

  • PDF

Transparent-Oxide-Semiconductor Based Staggered Self-Alignment Thin-Film Transistors

  • Yamagishi, Akira;Naka, Shigeki;Okada, Hiroyuki
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1105-1106
    • /
    • 2008
  • Staggered type self-aligned transparent-oxide-semiconductor transistors with indium-zinc-oxide as a semiconductor have studied. In this device fabrication, successive sputtering of oxide semiconductor and insulator without breaking of vacuum and without exposing in air, humidity and oxygen can be realized because oxide semiconductor is transparent. As a result of fabrication, transistor characteristics with mobility of $30cm^2/Vs$ and on-off ratio of $10^5$ could be obtained for the newly developed self-alignment device structure.

  • PDF

고강도 시멘트 경화체의 특성에 미치는 미세구조의 영향 (II) (Effect of Microstructure on the Prooperties of High Strength Hardened Cement Paste (II))

  • 김정환;최상흘;한기성
    • 한국세라믹학회지
    • /
    • 제27권8호
    • /
    • pp.1034-1042
    • /
    • 1990
  • Investigation for the preparation of high strength hardened cement paste using ordinary portland cement, hydroxypropyl methyl cellulose(HPMC) with various admixtures was carried out. The cement paste was mixed with 0.1 of water cement ratio by twin roll mill and cured 60 days in humidity chamber. When the quartz powder or white cement was added to the paste, the flexural strength was 900∼1000kg/㎠ and the Young's modulus was 8∼9×105kg/㎠. When the silicafume was added, the flexural strength was 800kg/㎠ and the Young's modulus was 6×105kg/㎠.

  • PDF

영남권 사찰림일대 소나무장령림의 미기후 조절 효과 연구 (Effectiveness of Controling Micro Climate by the Pine (Pinus Densiflora) Forests of the Temple in Southeast Area of Korea)

  • 홍석환;안미연;강래열;최송현
    • 한국환경생태학회지
    • /
    • 제34권4호
    • /
    • pp.294-303
    • /
    • 2020
  • 본 연구는 경남지역 내 소나무 장령림이 안정적으로 생육하고 있는 사찰 소나무림을 대상으로 온도 및 습도의 미기상 변화 특성과 식생분포특성을 비교하여 소나무장령림의 미기후 조절정도를 살펴보고자 하였다. 연구는 국내에서 소나무 장령림의 안정적 생육지로 알려진 합천 해인사, 부산 범어사, 양산 통도사 및 경주 불국사 일대 소나무림을 대상으로 하였다. 식생분포 현황 분석결과 이들 소나무림은 알려진 바와는 달리 소나무림의 면적비율이 월등히 높지는 않았는데, 통도사 주변을 제외하면 소나무림보다 낙엽활엽수림 및 혼효림의 우점비율이 훨씬 높게 나타나고 있었다. 미기상데이터 측정 결과 통도사는 다른 세 지역과는 달리 미기후 특성이 크게 차이가 있었는데, 다른 세 지역의 경우 온도 및 습도의 일교차가 상대적으로 적은 반면 통도사는 일교차가 크게 나타나는 현상을 보였다. 이는 통도사 주변 숲이 개발지를 제외하면 대부분 소나무림인 반면, 다른 세 지역은 낙엽활엽수림의 우점비율이 높은데 기인하는 것으로 판단된다. 소나무림의 적극적 관리는 온도상승과 공중습도의 감소에 효과적이지 않은 만큼 현재 양산 통도사 주변 소나무림과 같이 소나무 단순림으로의 적극적인 관리는 오히려 온도와 습도 스트레스 측면에서 부정적 영향이 더욱 큰 것을 확인할 수 있었다. 소나무림의 미기후 완화 효과 증대를 위해서는 숲 관리의 새로운 전환이 필요한 것으로 판단된다.

수경화성 폴리우레탄 방수재의 물 혼입량에 따른 인장성능 변화 추이 연구 (A Study on Trend of Tensile Properties with Ratio of Water Mixture in Hydroponic Polyurethane Waterproofing Materials)

  • 박완구;안현호;김선도;김동범;박진상;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.215-216
    • /
    • 2016
  • Urethane waterproofing materials which currently being used most commonly in the Korean domestic market have high applicability and construct layers without forming any joints, but under the influence of low temperature and low humidity, as well as the thickness of the applied layer, the curing time of this material may become extended in construction sites. To resolve these issues, a proposed method of using water-hardening type of polyurethane waterproofing materials are being developed. However, there currently lacks any standards or evaluation methods on determining an optimal mixture ratio of water for the water-hardening polyurethane waterproofing materials. Therefore, for the establishment of a board applicability of the water-hardening polyurethane waterproofing methods in construction sites, this study objectively analyzes the changes in the performance of these materials depending on the changes of the water mixture ratio and attempts to procure the optimal ratio on the basis of forming a provisionary standard.

  • PDF