Cooling Efficiency of Low Pressure Compressed Air Fogging System in Naturally Ventilated Greenhouses (저압 에어포그 시스템을 설치한 온실의 냉방효율)

  • Nam, Sang-Woon;Kim, Young-Shik;Sung, In-Mo;Ko, Gi-Hyuk
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.5
    • /
    • pp.49-55
    • /
    • 2012
  • In order to derive the efficient utilization of low pressure compressed air fogging system, cooling efficiencies with control types were analyzed through cooling experiments in tomato greenhouses. The control types were set up with temperature control, humidity control, temperature and humidity control, and time control. It showed that the cooling effects were 0.7 to $3.3^{\circ}C$ on average and maximum of 4.3 to $7.0^{\circ}C$, the humidification effects were 3.5 to 13.5 % on average and maximum of 14.3 to 24.4 %. Both the cooling and humidification effect were the highest in the time control method. The cooling efficiency of the air fogging system was not high with 8.3 to 27.3 % on average. However, the cooling efficiency of 24.6 to 27.3 % which appears from the time control is similar to the cooling efficiency of high pressure fogging system experimented in Japan. The air fogging system is operated by low pressure, but its efficiency is similar to high pressure. We think because it uses compressed air. From this point of view, we suggest that the air fogging system can get the cooling efficiency of similar levels to that of high pressure fogging system and it will have an advantage from clogging problem of nozzle etc.

Reliability Evaluation Criteria and Multi-Stress Aging Test for Polymer Insulator (폴리머 현수애자의 신뢰성 평가 및 복합가속열화 방법)

  • Park, Hoy-Yul;Kang, Dong-Pil;Ahn, Myeong-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.469-472
    • /
    • 2004
  • There have been numerous accelerated aging laboratory tests for evaluating suitability of polymeric materials and devices. Aging test for materials and its full scale device has been conducted, but poor correlation of aging test such as service experience were observed. Service experience plays a key role in the utility section of composite insulators. A meaningful and reliable accelerated aging test is needed for evaluating composite insulator. During the service these insulators are subjected to aging stress such as humidity, pollution, and electrical field, and erosion and tracking of the weathershed occurs. This paper presents the criteria of reliability evaluation and evaluation facilities for 22.9 kV suspension composite insulator. We adopt the criteria of reliability evaluation consist of two test methods. One is CEA tracking wheel test for examining the tracking and erosion performance of composite insulator. The other is multi-stress aging test for examining effects of environmental factors such as UV, temperature, humidity, etc on composite insulator.

  • PDF

Performance of an Duct-type HVAC System for Conservation of Ancient Tombs (고분보존용 덕트형 공조시스템의 운전 특성)

  • Jun, Yong-Du;Lee, Kum-Bae;Park, Jin-Yang;Ko, Seok-Bo;Jun, Hee-Ho;Youn, Young-Muk
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.29-34
    • /
    • 2006
  • Although the importance of good conservation of historic sites including ancient royal tombs is well aware, still not much attention has been paid for the facilities and systems to preserve those historic sites, which includes precious artifacts as wall paints and carved works, etc. Even the level of general understanding about the environment of the underground space of tombs is not satisfactory. In Korea, researchers have recently begun addressing the importance of maintaining proper environment for underground space as of ancient tombs and are making efforts to develop suitable HVAC(heating, ventilating and air-conditioning) systems for them. In this study, an HVAC system for a tomb ($D{\times}W{\times}H=1.3m{\times}3.0m{\times}1.2m$) was installed to maintain suitable indoor conditions for conservation of tomb. The temperature and humidity inside the tomb were measured to represent the performance of the installed duct-type HVAC system. Vibration levels due to the installed an HVAC system are alive investigated experimentally. According to the measured data, the level of vibration inside the present model tomb with the duct-type unit showed significantly lower values than the case with the indoor unit inside.

  • PDF

MyBed : IoT Based Sleep Helper (MyBed : IoT 기반 수면 도우미)

  • You, Sung-Min;Kim, Tae-jun;Kim, Tae-han;Kim, Sung-il;Heo, Gyeongyong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.423-424
    • /
    • 2021
  • In this paper, we propose a system that collects data from sensors that detect the sleeping environment and adjusts the sleeping environment optimally based on the environment to help you get a good night's sleep. The sleep environment analysis is based on the determination of the sleep stage by detection of twisting through the load cell. In addition, based on data such as temperature, humidity, and illuminance, heat devices, humidifiers, blinds, etc. are controlled to create an environment in which to have a good sleep. The sleep environment control according to the sleep state can reduce fatigue when waking up by inducing a sleep state that is easy to wake up.

  • PDF

Humidity Controlled Drying for the Fragments of an Wooden Boat in the Neolithic Age, Excavated from Bibong-ri, Changnyeong, Korea (창녕 비봉리 출토 신석기시대 나무배 편의 조습건조)

  • Kim, Soochul;Lee, Kwanghee
    • Conservation Science in Museum
    • /
    • v.14
    • /
    • pp.7-12
    • /
    • 2013
  • The conservation has been conducted for the fragments of an wooden boat in the Neolithic Age, excavated from Bibong-ri, Changnyeong, Korea. The vacuum-freeze drying have been applied to mostly to the small relics, such as wooden lacquerwares or small wooden goods etc.. Therefore, the large objects like a wooden boats have been treated almost by air-drying after impregnation with aqueous PEG solution. The air-drying is needed to impregnate with PEG aqueous solution during long period and run the risk of the fault generation. This report explain an example adapted for the fragments of the wooden boat by humidity-controlled drying(HCD) with slow adjusting moisture content. We did the chemical pre-treatment, PEG aqueous solution. The concentration of the aqueous solution was increased gradually from 10% to 80%. After the impregnation, the objects were dried by the HCD. The dimensional stability of the fragments after treatment was good.

Analysis of Optimal Placement Proposal of HVAC System in Smart Greenhouse using CFD Simulation

  • Minji Baek;Hyunsang Cho;Doyoung Lee;Jeonghwan Seo;Jimin Kim;Hyounseung Jang
    • International conference on construction engineering and project management
    • /
    • 2024.07a
    • /
    • pp.1316-1316
    • /
    • 2024
  • Greenhouses require various control systems to create an optimal environment, and from an architectural engineering perspective, the uniformity of the internal environment is crucial for crop growth. However, greenhouses are structurally exposed to external weather conditions, leading to a high probability of variations in temperature, humidity, CO2 levels, lighting, etc., across different zones within the greenhouse. Such non-uniformity can impact the growth rate, quality, and yield of crops, highlighting the necessity of maintaining a consistent environment within the greenhouse. To address this, experiments utilizing Computational Fluid Dynamics (CFD) simulations were conducted targeting greenhouses in Pocheon, South Korea, focusing on the central heating and cooling systems to propose an optimal design considering the uniformity of internal temperatures. Subsequently, validation was performed using measurements from temperature and humidity sensors within the greenhouses. The heating and cooling systems operate based on indoor temperatures, activating cooling when indoor temperatures exceed the set cooling temperature in summer and heating when temperatures fall below the set heating temperature in winter. A standard greenhouse model was set as case 1, and experiments were conducted by adjusting the position and spacing of the fabric ducts of the heating and cooling systems, resulting in six categorized cases. Variations in temperature and humidity distribution were observed among the cases, and quantitative analysis provided optimal positions and spacing for the fabric ducts. The results of this study can serve as foundational data for developing environmental control solutions for agricultural facilities.

Analysis on the Uniformity of Temperature and Humidity According to Environment Control in Tomato Greenhouses (토마토 재배 온실의 환경조절에 따른 온습도 균일도 분석)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.215-224
    • /
    • 2009
  • A survey on the actual state of heating, cooling, ventilation, and air-flow and experimental measurement of temperature and humidity distribution in tomato greenhouse were performed to provide fundamental data required in the development of air-flow control technology. In single-span plastic houses, which account for most of 136 tomato greenhouses surveyed, roof windows, ventilation and air-flow fans were installed in a low rate, and installation specs of those facilities showed a very large deviation. There were no farms installed greenhouse cooling facilities. In the hot air heating system, which account for most of heating type, installation specs of hot air duct showed also a large deviation. The exhaust air temperature and wind speed in hot air duct also were measured to have a big difference depending on the distance from the heater. We are using the maximum difference as indicator to determine whether temperature distribution is uniform. However if the temperature slope is not identical in greenhouse, it can't represent the uniformity. We analyzed relation between the maximum difference and the uniformity of temperature and humidity distribution. The uniformity was calculated using the mean and standard deviation of data from 12 measuring points. They showed high correlation but were represented differently by linear in the daytime and quadratic in the nighttime. It could see that the uniformity of temperature and humidity distribution was much different according to greenhouse type and heating method. The installation guidelines for ventilation and air-flow fan, the spread of greenhouse cooling technology for year-round stable production, and improvement of air duct and heating system, etc. are needed.

Evaluation on the Cooling Performance of Geothermal-energy Using Heat Pump System in Mixed-use Residential Building (주상복합 건축물에 적용된 지열이용 히트펌프 시스템의 냉방성능 평가)

  • Kim, Yong-Shik;Kim, Jung-Heon;Hwang, Kwang-Il
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.4
    • /
    • pp.9-16
    • /
    • 2006
  • Geothermal-energy has been getting popular as a natural energy source for green buildings these days. Public building with gross area more than $3000m^2$, planned after March, 2005, should spend about 5% of total building cost for equipment run by natural energy source (e.g. geothermal, solar heat, solar power, etc) according to renewable energy promotion law in Korea. As a result geothermal-energy using heat pump system is emerging as a effective alternative for realistic and economic plan although design guidelines and construction code for the system is in progress and technical data is far from sufficient. The quantitative analysis on the performance of geothermal-energy using heat pump system is insufficient for appropriate design of it. In this paper, cooling performance of geothermal-energy using heat pump system of residential and retail etc. mixed-use building has been analyzed on the basis of temperature comparison between inlet and outlet of heat exchangers of the operating system. Additionally, dry-bulb temperature and relative humidity have been measured and analyzed together as an index of indoor thermal environment.

Bacterial Distribution in Dried Salted Marine Products, Sold in Garak Wholesale Market (시판 조미건어포류 식품의 위생세균 분포)

  • Ham Hee-Jin;Kim Ae-Kyung;Kim Moo-Sang
    • Journal of Food Hygiene and Safety
    • /
    • v.21 no.2
    • /
    • pp.70-75
    • /
    • 2006
  • Of 111 bacterial isolates on 32 dried salted marine products in Garak wholesale market.72 strains were coliforms, and 12 were staphylococcus spp. etc. In average, humidity 17.28%, ashes 4.92%, standard plate count $1.1{\times}10^7$ CFU/ml, coliforms count $9.0{\times}10^3$ CFU/ml, staphylococcus spp. $5.4{\times}10^6$ CFU/ml respectively. Of 72 coliforms, it was isolated by 21 Pantoea spp, 14 Enterobacter cloacae and, 13 Ranella aquatilis, etc. and of 12 Staphylococcus spp. 4 staphylococcus xylosus was the most.

Study on IR Signature Characteristics for different Transmittance over the Korean South Sea during Summer and Winter Seasons (거제도 해양의 여름 및 겨울철 환경에서 거리에 따른 대기투과도를 고려한 함정의 적외선 신호 특성 분석)

  • Choi, Jun-Hyuk;Kim, Jung-Ho;Jung, In-Hwa;Lee, Phil-Ho;Kim, Tae-Kuk
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.320-327
    • /
    • 2010
  • The IR signature data of a ship is mainly affected by location, meteorological conditions(atmosphere temperature, wind direction and velocity, humidity etc.), atmospheric transmittance, solar position and ship surface temperature etc. The IR signatures received by a remote sensor at a given temperature and wavelength region is consisted of the self-emitted component directly from the object surface, the reflected component of the solar irradiation at the object surface, and the scattered component by the atmosphere without ever reaching the object surface. Computer simulations for prediction of the IR signatures of ships are very useful to examine the effects of various sensor positions. In this paper, we have acquired the IR signature for different sensor positions by using computer program for prediction of the IR signatures. The numerical results show that the IR signature contrast as compared to the background sea considering the meteorological conditions, solar and sky irradiations.