• Title/Summary/Keyword: Human plasma

Search Result 995, Processing Time 0.039 seconds

Fabrication and Simulation of Fluid Wing Structure for Microfluidic Blood Plasma Separation

  • Choe, Jeongun;Park, Jiyun;Lee, Jihye;Yeo, Jong-Souk
    • Applied Science and Convergence Technology
    • /
    • v.24 no.5
    • /
    • pp.196-202
    • /
    • 2015
  • Human blood consists of 55% of plasma and 45% of blood cells such as white blood cell (WBC) and red blood cell (RBC). In plasma, there are many kinds of promising biomarkers, which can be used for the diagnosis of various diseases and biological analysis. For diagnostic tools such as a lab-on-a-chip (LOC), blood plasma separation is a fundamental step for accomplishing a high performance in the detection of a disease. Highly efficient separators can increase the sensitivity and selectivity of biosensors and reduce diagnostic time. In order to achieve a higher yield in blood plasma separation, we propose a novel fluid wing structure that is optimized by COMSOL simulations by varying the fluidic channel width and the angle of the bifurcation. The fluid wing structure is inspired by the inertial particle separator system in helicopters where sand particles are prevented from following the air flow to an engine. The structure is ameliorated in order to satisfy biological and fluidic requirements at the micro scale to achieve high plasma yield and separation efficiency. In this study, we fabricated the fluid wing structure for the efficient microfluidic blood plasma separation. The high plasma yield of 67% is achieved with a channel width of $20{\mu}m$ in the fabricated fluidic chip and the result was not affected by the angle of the bifurcation.

Direct treatment on live and cancer cells & process innovation of bio-sensor using atmospheric pressure plasma system with low-temperature arc-free unit

  • Lee, Keun-Ho;Lee, Hae-Ryong;Jun, Seung-Ik;Bahn, Jae-Hoon;Baek, Seung-J.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.43-43
    • /
    • 2010
  • We have characterized the parametric and functional properties of live cell and cancer cell according to plasma treatment conditions using Atmospheric Pressure (AP) Plasma with uniquely designed low temperature arc-free unit. AP plasma system showed very highly efficient capabilities of reacting and interfacing directly with live and cancer cells. The parametric results with the types of gases, applied power, applied gap, and process times on cells will be presented in accordance with functional studies of the works. The growth of cancer cells is directly influenced by AP plasma exposure with evaluating plasma conditions in several human cancer cells and understanding how plasma exposure alters molecular signaling pathways. The cells exhibit a slower or faster growth rates compared with untreated cells, depending on the cell types. These results strongly support the conclusion that alterations in one or more of each gene are responsible, at least in part, for plasma-induced apoptosis in cancer cells. In addition, it also will be presented that AP plasma has an important role for the improvement of sensor performance due to excellent interface property between enzyme and metal electrode for bio sensor manufacturing process.

  • PDF

Effects of the Administration of Human Menopausal Gonadotropin on the Pregnancy in Rats (임신 랫드에 투여한 Human Menopausal Gonadotropin이 임신에 미치는 영향)

  • 김영홍;이근우;남현욱;손창호
    • Journal of Veterinary Clinics
    • /
    • v.21 no.2
    • /
    • pp.109-114
    • /
    • 2004
  • The effect of Human Menopausal Gonadotropin(hMG) on the implantation, pregnancy, and the concentration of plasma progesterone were studied in pregnant rats. HMG 75 or 150 IU were administered once on day 1, 2, 3, 4, 9, 12 or 14 of gestation, respectively. Rats were autopsied on day 7 or 18. A single dose of hMG prevented implantation and terminated pregnancy in all of the rats by injecting on either day 1 or day 2 and this abortifacient action was effective 82-98% of pregnant rats on day 3 or 4 and 14-20% on day 9 or 12. Administration of hMG had no effect on termination of pregnancy on day 14. Plasma progesterone concentration by injecting hMG on day 1, 2, 3 or 4 were very decreased.

Simultaneous determination of sildenafil and its active metabolite in human plasma using LC/MS/MS

  • Ji, Hye-Young;Kim, Sook-Jin;Lee, Hong-Il;Lee, Seung-Seok;Lee, Hye-Sook
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.402.1-402.1
    • /
    • 2002
  • The LC/MS/MS method for the simultaneous determination of sildenafil and its active metabolite N-demethylsildenafil in human plama was developed. Sildenafil. its active metabolite and the internal standard. DA-8159 were extracted form human plasma by liquid-liquid partitioning. A reverse-phase HPLC separation was performed on Luna phenylhexyl column with the mixture of acetonitrile-5 mM ammonium formate (55:45. v/v) as mobile phase. (omitted)

  • PDF

Application of the Alkaline Comet Assay for Detecting Oxidative DNA Damage in Human Biomonitoring (인체 산화적 DNA손상에 대한 Human Biomonitoring도구로서 Alkaline Comet Assay의 활용 가능성 연구)

  • 박은주;강명희
    • Journal of Nutrition and Health
    • /
    • v.35 no.2
    • /
    • pp.213-222
    • /
    • 2002
  • The alkaline comet assay has been used with increasing popularity to investigate the level of DNA damage in biomonitoring studies within the last decade in Western countries. The purpose of this study was to evaluate the usefulness of the alkaline comet assay as a biomarker of oxidative DNA damage for monitoring in the Korean population, and also to evaluate the effect of nutritional status and lifestyle factors on H2O2 induced oxidative DNA damage measured by the alkaline comet assay in human lymphocytes. The study population consisted of 61 healthy Korean male volunteers, aged 20-28. Epidemiological background data including dietary habits, smoking habits and anthropometrical measurements were collected through personal interviews. After blood collection, the comet assay in peripheral lymphocytes and plasma lipids analysis was carried out and the results analyzed. Tail moment (TM) and tail length (TL) of the comet assay were use\ulcorner to measure DNA damage in the lymphocytes of the subjects. Statistically significant (p < 0.05) positive correlations were observed between DNA damage (TM or TL) and smoking habits expressed as cigarettes smoked per day and pack years (r = 0.311 and 0.382 for TM, r = 0.294 and 0.350 for TL, respectively). There were also significant positive correlations between DNA damage parameter and waist-hip ratio. Higher plasma triglyceride levels were associated with increased damage to DNA. There were no correlations between the consumption frequencies of vegetables and DNA damage to the subjects. However, consumption frequencies of fruit and fruit juice intake were inversely associated with the TM and TL. The results indicate that die comet assay is a simple, rapid and sensitive method for detecting lymphocyte DNA damage induced by cigarette smoking. Consumption of fruit or fruit juices could potentiall modify the damaged DNA in the human peripheral lymphocytes of young Korean men.

Determination of Mequitazine in Human Plasma by Gas-Chro-matography/Mass Spectrometry with Ion-Trap Detector and Its Pharmacokinetics after Oral Administration to Volunteers

  • Kwon Oh-Seung;Kim Hye-Jung;Pyo Heesoo;Chung Suk-Jae;Chung Youn Bok
    • Archives of Pharmacal Research
    • /
    • v.28 no.10
    • /
    • pp.1190-1195
    • /
    • 2005
  • The objective of this study was to develop an assay for mequitazine (MQZ) for the study of the bioavailability of the drug in human subjects. Using one mL of human plasma, the pH of the sample was adjusted and MQZ in the aqueous phase extracted with hexane; the organic layer was then evaporated to dryness, reconstituted and an aliquot introduced to a gas chromatograph/mass spectrometer (GC/MS) system with ion-trap detector. Inter- and intra-day precision of the assay were less than 15.1 and $17.7{\%}$, respectively; Inter- and intra-day accuracy were less than 8.91 and $18.6{\%}$, respectively. The limit of quantification for the current assay was set at 1 ng/mL. To determine whether the current assay is applicable in a pharmacokinetic study for MQZ in human, oral formulation containing 10 mg MQZ was administered to healthy male subjects and blood samples collected. The current assay was able to quantify MQZ levels in most of the samples. The maximum concentration ($C_{max}$ was 8.5 ng/mL, which was obtained at 10.1 h, with mean half-life of approximately 45.5 h. Under the current sampling protocol, the ratio of $AUC_{t{\rightarrow}last}$ to $AUC_{t{\rightarrow}{\infty}}$ was $934{\%}$, indicating that the blood collection time of 216 h is reasonable for MQZ. Therefore, these observations indicate that an assay for MQZ in human plasma is developed by using GC/MS with ion-trap detector and validated for the study of pharmacokinetics of single oral dose of 10 mg MQZ, and that the current study design for the bioavailability study is adequate for the drug.

Angiogenic factor-enriched platelet-rich plasma enhances in vivo bone formation around alloplastic graft material

  • Kim, Eun-Seok;Kim, Jae-Jin;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.1
    • /
    • pp.7-13
    • /
    • 2010
  • Although most researchers agree that platelet-rich plasma (PRP) is a good source of autogenous growth factors, its effect on bone regeneration is still controversial. The purpose of this study was to evaluate whether increasing angiogenic factors in the human PRP to enhance new bone formation through rapid angiogenesis. MATERIAL AND METHODS. In vitro, the human platelets were activated with application of shear stress, $20\;{\mu}g/ml$ collagen, 2 mM $CaCl_2$ and 10U thrombin/$1\;{\times}\;10^9$ platelets. Level of vascular endothelial growth factor (VEGF) and platelet microparticle (PMP) in the activated platelets were checked. In the animal study, human angiogenic factors-enriched PRP was tested in 28 athymic rat's cranial critical bone defects with $\beta$-TCP. Angiogenesis and osteogenesis were evaluated by laser Doppler perfusion imaging, histology, dual energy X-ray densinometry, and micro-computed tomography. RESULTS. In vitro, this human angiogenic factors-enriched PRP resulted in better cellular proliferation and osteogenic differentiation. In vivo, increasing angiogenic potential of the PRP showed significantly higher blood perfusion around the defect and enhanced new bone formation around acellular bone graft material. CONCLUSION. Angiogenic factor-enriched PRP leads to faster and more extensive new bone formation in the critical size bone defect. The results implicate that rapid angiogenesis in the initial healing period by PRP could be supposed as a way to overcome short term effect of the rapid angiogenesis.

Validation of the LC-MS/MS Method for Ginsenoside Rb1 Analysis in Human Plasma (LC-MS/MS를 이용한 인체 혈장에서 Ginsenoside Rb1의 분석법 검증)

  • Han, Song-Hee;Kim, Yunjeong;Jeon, Ji-Young;Hwang, Minho;Im, Yong-Jin;Lee, Sun Young;Chae, Soo-Wan;Kim, Min-Gul
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.12
    • /
    • pp.1753-1757
    • /
    • 2012
  • A new liquid chromatographic tandem mass spectrometric (LC-MS/MS) assay for the quantification of ginsenoside Rb1 in human plasma was developed and validated. The separation was performed on a Agilent C18 column ($4.6mm{\times}150mm$, particle size 5 ${\mu}m$) with a gradient elution of 0.1% formic acid in water and 0.1% formic acid in methanol and a flow rate of 0.9 mL/min. The analyte was determined using electrospray positive ionization mass spectrometry in the multiple reaction monitoring (MRM) mode (m/z 1131.714${\rightarrow}$365.303). Human plasma samples were extracted with acetone : water (50:50) by the liquid-liquid extraction method. The method was linear over the dynamic range of 10~500 ng/mL with a correlation coefficient of r=0.9995. The intra-and inter-day precision over the concentration range of ginsenoside Rb1 was lower than 5.8% (correlation of variance, CV), and the accuracy was between 96.0~104.6%. This LC-MS/MS assay of ginsenoside Rb1 in human plasma is applicable for quantification in a pharmacokinetic study.

Measurement of electron density of atmospheric pressure Ar plasma jet by using Michelson interferometer

  • Lim, Jun-Sup;Hong, Young June;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.195.1-195.1
    • /
    • 2016
  • Currently, as Plasma application is expanded to the industrial and medical industrial, low temperature plasma applications became important. Especially in medical and biology, many researchers have studied about generated radical species in atmospheric pressure low temperature plasma directly adapted to human body. Therefore, so measurement their plasma parameter is very important work and is widely studied all around world. One of the plasma parameters is electron density and it is closely relative to radical production through the plasma source. some kinds of method to measuring the electron density are Thomson scattering spectroscopy and Millimeter-wave transmission measurement. But most methods have very expensive cost and complex configuration to composed of experiment system. We selected Michelson interferometer system which is very cheap and simple to setting up, so we tried to measuring electron density by laser interferometer with laser beam chopping module for measurement of temporal phase difference in plasma jet. To measuring electron density at atmospheric pressure Ar plasma jet, we obtained the temporal phase shift signal of interferometer. Phase difference of interferometer can occur because of change by refractive index of electron density in plasma jet. The electron density was able to estimate with this phase difference values by using physical formula about refractive index change of external electromagnetic wave in plasma. Our guiding laser used Helium-Neon laser of the centered wavelength of 632 nm. We installed chopper module which can make a 4kHz pulse laser signal at the laser front side. In this experiment, we obtained more exact synchronized phase difference between with and without plasma jet than reported data at last year. Especially, we found the phase difference between time range of discharge current. Electron density is changed from Townsend discharge's electron bombardment, so we observed the phase difference phenomenon and calculated the temporal electron density by using phase shift. In our result, we suggest that the electron density have approximately range between 1014~ 1015 cm-3 in atmospheric pressure Ar plasma jet.

  • PDF

Adhesion of Human Osteoblasts Cell on CrN Thin Film Deposited by Cathodic Arc Plasma Deposition

  • Pham, Vuong-Hung;Kim, Sun-Kyu
    • Journal of the Korean institute of surface engineering
    • /
    • v.42 no.5
    • /
    • pp.203-207
    • /
    • 2009
  • Interaction between human osteoblast (hFOB 1.19) and CrN films was conducted in vitro. CrN films were produced by cathodic arc plasma deposition. The surface was characterized by atomic force microscopy (AFM). CrN films, glass substrates and TiN films were cultured with human osteoblasts for 48 and 72 hours. Actin stress fiber patterns and cell adhesion of osteoblasts were found less organized and weak on CrN films compared to those on the glass substrates and the TiN films. Human osteoblasts also showed less proliferation and less distributed microtubule on CrN films compared to those on glass substrates and TiN films. Focal contact adhesion was not observed in the cells cultured on CrN films, whereas focal contact adhesion was observed well in the cells cultured on glass substrates and TiN films. As a result, the CrN film is a potential candidate as a surface coating to be used for implantable devices which requires minimal cellular adhesion.