• Title/Summary/Keyword: Human joints

Search Result 295, Processing Time 0.024 seconds

A Research on the ORyungJinAekByeol of the Young Chu(靈樞) (영추(靈樞).오륭진액별에 대한 연구(硏究))

  • Sin, Yeong-Il;Jeong, Jong-Guk
    • Journal of Korean Medical classics
    • /
    • v.13 no.2 s.17
    • /
    • pp.156-171
    • /
    • 2000
  • Body fluid(津液) is a general term for normal mucus in human body, including saliva, gastric juice, intestinal juice and articular fluid in joints as well as tear, running nose, sweat, etc.. The formation of Body fluid goes through two phases. First phase is digestion of food at stomach, and then evaporation and classification of energy at Triple warmer(三焦). More technically speaking, Body fluid is divided into the Jin(津) & the Aek(液). Aek is a very mild and water-like fluid, runs deep into the internal organs. Jin is a thick and sticky liquid, running shallow under the skin or in the joints of limbs. Major roles of body fluid over the body are to moisturize the internal organs, flesh, skin, etc., to soften the joints, to fill the bone marrow, and to balance Yin and Yang. This article deals with the role of body fluid and how to differentiate them, the liquid metabolism in the human body, and the formation and change of sweat, urine, tear, spit, bone marrow, etc.. The imbalance of Yin and Yang and disturbance of Triple warmer's evaporation lead into lumbago, leg weakness and edema is also explained here.

  • PDF

Safe Arm Design with MR-based Passive Compliant Joints and Visco-elastic Covering for Service Robot Applications

  • Yoon Seong-Sik;Kang Sungchul;Yun Seung-kook;Kim Seung-Jong;Kim Young-Hwan;Kim Munsang
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.10
    • /
    • pp.1835-1845
    • /
    • 2005
  • In this paper a safe arm with passive compliant joints and visco-elastic covering is designed for human-friendly service robots. The passive compliant joint (PCJ) is composed of a magneto-rheological (MR) damper and a rotary spring. In addition to a spring component, a damper is introduced for damping effect and works as a rotary viscous damper by controlling the electric current according to the angular velocity of spring displacement. When a manipulator interacts with human or environment, the joints and cover passively operate and attenuate the applied collision force. The force attenuation property is verified through collision experiments showing that the proposed passive arm is safe in view of some evaluation measures.

A Study on the Upper Body Range of Motion (Using a 3-D Motion Anlaysis System) about Korean Adults (한국 성인 남자의 상체 동작범위 연구 - 3D 동작분석 장치를 이용하여 -)

  • 박길순;유신아
    • The Research Journal of the Costume Culture
    • /
    • v.8 no.4
    • /
    • pp.587-601
    • /
    • 2000
  • The purpose of this study : 1. The total 56 range measurements of active dynamic motion of 40 subjects (20's and 30's) were measured using 3-D dynamic motion analysis system. 2. Various comparisons were performed for the right and left side, male, age groups (20's, 30's, and 40's ∼ 60's) using previous studies. The results were compared with the other studies in the aspects of age. In this study, the 3-D motion analysis system based on photogrammetry was established and used to analyze the human's motion and posture. The system consists of VICON 140, data acquisition system, and data analysis program (KRISSMAS). The result of this study were as follows : 1. Comparing 20's with 30's the result shows that 30's have larger ROM at some joints, which is inconsistent with the previous result. The reason is that female subjects in 20's were improperly sampled according to the representatives of anthropometry characteristics. 2. There are significant differences in some joints related with age. 20's male subjects have more flexible joints in the neck while 30's male subjects have more flexibility in their shoulder joint and elbow joint. But most of the significances were not high (p〈0.05). The prediction that the right side of Korean bodies would be more flexible was not a good hypothesis. And the joints flexibilities are not correlated with Rohrer's Index.

  • PDF

Development of Simple Articulated Human Models using Superquadrics for Dynamic Analysis

  • Lee, Hyun-Min;Kim, Jay-Jung;Chae, Je-Wook
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.6
    • /
    • pp.715-725
    • /
    • 2011
  • Objective: This study is aimed at developing Articulated Human Models(AHM) using superquadrics to improve the geometric accuracy of the body shape. Background: The previous work presents the AHM with geometrical simplification such as ellipsoids to improve analysis efficiency. However, because of the simplicity, their physical properties such as a center of mass and moment of inertia are computed with errors compared to their actual values. Method: This paper introduces a three steps method to present the AHM with superquadrics. First, a 3D whole body scan data are divided into 17 body segments according to body joints. Second, superquadric fitting is employed to minimize the Euclidean distance between body segments and superquadrics. Finally, Fee-Form Deformation is used to improve accuracy over superquadric fitting. Results: Our computational experiment shows that the superquadric models give better accuracy of dynamic analysis than that of ellipsoid ones. Conclusion: We generate the AHM composed of 17 superquadrics and 16 joints using superquadric fitting. Application: The AHM using superquadrics can be used as the base model for dynamics and ergonomics applications with better accuracy because it presents the human motion effectively.

A Study on the Injury Assessment of Helicopter's Crew with Multi Point Restraint System under Drop Impact (낙하 충격을 받는 다점 구속 장치를 착용한 헬기 승무원의 상해도 평가에 관한 연구)

  • Lee, Jung-Hyun;Lee, Young-Shin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.6
    • /
    • pp.590-599
    • /
    • 2009
  • In this paper, a method of modeling seat belts on crew seat during dynamic seat testing was studied. The body segments of the occupant were modeled with joints. The joints consisted with various stiffnesses, dampings, and frictions. Three types of seat belt restraint systems were investigated. The analysis for on the injury assessment of helicopter's crew under drop impact was conducted. The effectiveness of the seat belt system for crashworthiness and safety was evaluated. As the results of impact analysis, head, neck and spine of the crew can be easily damaged in the vertical direction more than the longitudinal direction. Based on the verified model, behavior of human body was studied with three-point restraint systems. The displacement and injury level of the 12-point restraint system was the smallest.

Development of Human-Sized Biped Robot (인체형 이족 보행로봇의 개발)

  • 최형식;박용헌;이호식;김영식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.15-18
    • /
    • 2000
  • We developed a human-sized BWR(biped walking robot) driven by a new actuator based on the ball screw which has high strength and high gear ratio. The robot overcomes the limit of the driving torque of conventional BWRs. Each leg of the robot is composed of three pitch joints and one roll joint. In all, a 10 degree-of-freedom robot with two balancing joints was developed. The BWR was developed to walk autonomously such that it is actuated by small torque motors and is boarded with DC battery and controllers. In the performance test, the BWR performed nice motions of sitting-up and sitting-down. Through the test, we could find capability of high performance in biped-walking.

  • PDF

Modelling of Ergonomics and Muscular Comfort

  • Eberhard Haug;Alain Tramecon;J. C. Allain;Park, Hyung-Yun
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.982-994
    • /
    • 2001
  • Commercially available software packages permit to position human models of various geometries in practical scenarios while respecting the anatomical constraints of the skeletal joints and of the bulk of the bodies. Beyond such features, the PAM-Comfort(sup)TM software has been conceived to provide direct access to the muscular forces needed by humans to perform physical actions where muscle force is required. The PAM-Comfort(sup)TM human models are made of multi-body linked anatomical skeletons, equipped with finite elements of the relevant skeletal muscles. The hyper-static problem of determination of muscle forces is solved by optimisation technique. Voluntary stiffening of muscles can be added to the basic contraction levels needed to perform a specific task. The calculated muscle forces obey Hills model. The model and software have been applied in several interesting scenarios of various fields of application, such as car industry, handling of equipment and sports activities.

  • PDF

Development of Human-Sized Biped Robot of improvement in model (이족 보행로봇 개선모델의 개발)

  • 최형식;박용헌;정경식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.458-461
    • /
    • 1997
  • We have developed a human-sized BWR(biped walking robot) driven by a new actuator based on the ball screw which has high strength and high gar ratio. Each leg of the robot is composed of three pitch joints and one roll joint. In all, a 10 degree-of-freedom robot with two balancing joints was developed. For the purpose of autonomous walking and higher performance, we improved the previous developed BWR. We improved the motor drive efficiency, designed the ball screw actuator in a modular type, and simplified the electric wires. Through this modification, we achieved better performance in walking.

  • PDF

Development of a Human-Sized Biped Walking Robot (인체형 이족보행로봇의 개발)

  • 최형식;박용헌;김영식
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.6
    • /
    • pp.484-491
    • /
    • 2002
  • We developed a new type of human-sized BWR (biped walking robot) driven by a new actuator based on the ball screw which has high strength and high gear ratio. Each leg of the robot is composed of three pitch joints and one roll joint. In all, a 10 degree-of-freedom robot with two balancing joints was developed. A new type of actuator for the robot is proposed, which is composed of four bar link mechanism driven by the ball screw. The robot overcomes the limit of the driving torque of conventional BWRs. The BWR was designed to walk autonomously by adapting small DC motors for the robot actuators and has a space to board DC battery and controllers. In the performance test, the BWR performed sitting-up and down motion, and walking motion. Through the test, we found the possibility of a high performance biped-walking.

Development of Human-Sized Biped Robot (인체형 이족 보행로봇의 개발)

  • 최형식;박용헌;이호식;김영식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.267-267
    • /
    • 2000
  • We developed a human-sized BWR(biped walking robot) driven by a new actuator based on the ball screw which has high strength and high gear ratio. The robot overcomes the limit of the driving torque of conventional BWRs. Each leg of the robot is composed of three pitch joints and one roll joint. In all, a 10 degree-of-freedom robot with two balancing joints was developed. The BWR was developed to walk autonomously such that it is actuated by small torque motors and is boarded with DC battery and controllers. In the performance test, the BWR peformed nice motions of sitting-up and sitting-down. Through the test, we could find capability of high performance in biped-walking.

  • PDF