• Title/Summary/Keyword: Human joints

Search Result 295, Processing Time 0.028 seconds

Morphological Changes in the Mandibular Condyle Following Botulinum Toxin Injection into the Human Masseter Muscle

  • Younjung Park;Junghoon Hong;Hyok Park;Naoya Kakimoto;Seong Taek Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.48 no.1
    • /
    • pp.16-24
    • /
    • 2023
  • Purpose: To determine the effects of botulinum toxin (BoNT) injection into the human masseter muscle on the morphology of the mandibular condyle bone using cone-beam computed tomography (CBCT). Methods: Twenty volunteers were randomly assigned to one of two groups. Group I received a single BoNT injection; Group II received two injections, with the second being administered 4 months after the first. CBCT scans of both temporomandibular joints (TMJs) were performed before and 6 months after the first injection. Bony changes in the cortical layers of the condyle heads were evaluated and the long and short axes of both mandibular condyles were measured. The thickness at the thinnest part of glenoid fossa was also quantitatively measured. Results: There was no significant difference between pre- and post-injection CBCT images. Furthermore, no changes in the cortical layers of the condyle heads were observed among the subjects who exhibited mild degenerative TMJ changes. The quantitative measurements (long axis, short axis, and the thickness of thinnest part of glenoid fossa roof) did not differ significantly between pre- and post-injection except for the long axis in Group I. Conclusions: Within the limitations of this study, it appears that BoNT injections into human masseter muscles do not alter the morphology of the mandibular condyle bone in healthy adults.

Assessment of the Synovial Inflammation in Rheumatoid Arthritis with $^{99m}Tc$-labelled Polyclonal Human IgG(HIG): Prospective Comparison with Gadolinium Enhanced MRI ($^{99m}Tc$-labelled HIG 스캔을 이용한 류마티스 관절염 환자에서 활막염증의 평가 : 조영증강 자기공명영상과의 전향적인 비교)

  • Ryu, Young-Hoon;Lee, Jong-Doo;Suh, Jin-Suck;Park, Chang-Yun;Jeon, Pyoung;Na, Jae-Beom;Lee, Soo-Kon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.84-91
    • /
    • 1995
  • Many clinical and laboratory tests have been employed to evaluate disease activity in rheumatioid arthritis. $^{99m}Tc$-labelled polyclonal IgG(HIG) has been demonstrated to accumulate in focal sites of infection or inflammation in both animals and human subjects. The purpose of this study was to distinguish arthritis with active inflammation from those without active inflammation and to correlate relative intensities of $^{99m}Tc$-labelled HIG uptake of the rheumatoid arthritis with clinical and MR indices of the joint inflammation. This study included twelve patients with active rheumatoid arthritis, two with ankylosing spondylitis and one with degenerative osteoarthritis without active inflammation. A Whole-body and spot images were obtained 4 hours after intravenous injection of 20mCi of $^{99m}Tc$-labelled HIG. Scintigrams were assessed visually by 3 experienced radiologists, and graded as normal or mildly and markedly increased uptake within the joints, and the degree of uptake was compared with clinical and radiologic severity of synovial inflammation. MRI studies were done on the involved joints consisted of wrist(n = 11), knee(n = 2) and hip joint(n= 2). Active synovitis was defined when marked elevation of ESR and gadolinium enhancement of synovium on MRI were demonstrated. Markedly increased radiotracer uptake was seen in 10 of 11 rheumatoid arthritic patients with active synovitis whereas normal or mildly increased uptakes were noted in others, including rheumatoid arthritic patient(n=1) and non-rheumatoid patients(n = 3) without active synovitis. This study showed that the localization of involved joints in rheumatoid arthritis could be detected with $^{99m}Tc$-labelled HIG and that the degree of uptake correlated well with the degree and activity of inflammation. In conclusion, $^{99m}Tc$-labelled HIG scan is a useful method in the evaluation of active inflammation in rheumatoid arthritis.

  • PDF

Foot/Ankle Roll-Over Characteristics According to Different Heel Heights of Shoe during Walking (보행 시 신발 굴 높이어 따른 발/발목 복합체의 Roll-Over특성)

  • Kim, Young-Ho;Choi, Hue-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.4
    • /
    • pp.247-253
    • /
    • 2005
  • This study investigated the effects on foot and ankle roll-over characteristics according to different heel heights during walking. Fifteen female volunteers who have neither musculoskeletal nor foot problems were participated in gait analyses, wearing four different pairs of shoes in different heel heights. To obtain roll-over shape of foot/ankle complex, we used trajectories of knee and ankle joints as well as the renter of pressure between initial contact and opposite initial contact. Results revealed that the entire roll-over shape moved distally as the heel height increased but roll-over characteristics showed uniformly with different heel heights. In addition, we found that nondisablea persons automatically adapted to their foot/ankle complex to varying heel heights within 6cm, by moving the origin of roll-over shape distally to maintain roll-over characteristics. However, since the balance of the gait only by the ankle joint could not be achieved beyond the heel height of 6cm, compensations at the knee and the hip joints occurred simultaneously. Roll-over characteristics in human walking would provide simpler and wider understanding of human walking, and furthermore could be applied to the wide understanding of prosthetics and orthotics of the lower extremity as well as orthopaedic shoes.

High-Quality Depth Map Generation of Humans in Monocular Videos (단안 영상에서 인간 오브젝트의 고품질 깊이 정보 생성 방법)

  • Lee, Jungjin;Lee, Sangwoo;Park, Jongjin;Noh, Junyong
    • Journal of the Korea Computer Graphics Society
    • /
    • v.20 no.2
    • /
    • pp.1-11
    • /
    • 2014
  • The quality of 2D-to-3D conversion depends on the accuracy of the assigned depth to scene objects. Manual depth painting for given objects is labor intensive as each frame is painted. Specifically, a human is one of the most challenging objects for a high-quality conversion, as a human body is an articulated figure and has many degrees of freedom (DOF). In addition, various styles of clothes, accessories, and hair create a very complex silhouette around the 2D human object. We propose an efficient method to estimate visually pleasing depths of a human at every frame in a monocular video. First, a 3D template model is matched to a person in a monocular video with a small number of specified user correspondences. Our pose estimation with sequential joint angular constraints reproduces a various range of human motions (i.e., spine bending) by allowing the utilization of a fully skinned 3D model with a large number of joints and DOFs. The initial depth of the 2D object in the video is assigned from the matched results, and then propagated toward areas where the depth is missing to produce a complete depth map. For the effective handling of the complex silhouettes and appearances, we introduce a partial depth propagation method based on color segmentation to ensure the detail of the results. We compared the result and depth maps painted by experienced artists. The comparison shows that our method produces viable depth maps of humans in monocular videos efficiently.

Comfort Analysis of Mono-ski with Hydraulic Absorber (모노스키 유압 완충장치 특성에 따른 탑승 안락감 평가)

  • Cho, Hyeon-Seok;Park, Jin-Kook;Kim, Gyoo-Seok;Mun, Mu-Sung;Kim, Chang-Boo
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.2
    • /
    • pp.131-140
    • /
    • 2015
  • The mono-ski for the paraplegia designed to skiing is formed as seat bucket on the sled. The impact force transferred by snow surface during skiing is absorbed by the leg joints of normal human, but it is transferred to the human body on the seat when using mono-ski. Most of commercially available mono-ski have absorbing device and link mechanism between seat and ski mount in order to complement it. In this study we developed the comfort evaluation model that could provide skiing simulation of mono-ski with hydraulic damper and analyzed vibrational acceleration occurred during skiing uneven surface. The evaluation method used in this study is the international standard BS6841. We evaluated comfort performance of mono-ski in accordance with nozzle adjustment of hydraulic damper.

The Examination of Reliability of Lower Limb Joint Angles with Free Software ImageJ

  • Kim, Heung Youl
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.6
    • /
    • pp.583-595
    • /
    • 2015
  • Objective: The purpose of this study was to determine the reliability of lower limb joint angles computed with the software ImageJ during jumping movements. Background: Kinematics is the study of bodies in motion without regard to the forces or torques that may produce the motion. The most common method for collecting motion data uses an imaging and motion-caption system to record the 2D or 3D coordinates of markers attached to a moving object, followed by manual or automatic digitizing software. Above all, passive optical motion capture systems (e.g. Vicon system) have been regarded as the gold standards for collecting motion data. On the other hand, ImageJ is used widely for an image analysis as free software, and can collect the 2D coordinates of markers. Although much research has been carried out into the utilizations of the ImageJ software, little is known about their reliability. Method: Seven healthy female students participated as the subject in this study. Seventeen reflective markers were attached on the right and left lower limbs to measure two and three-dimensional joint angular motions. Jump performance was recorded by ten-vicon camera systems (250Hz) and one digital video camera (240Hz). The joint angles of the ankle and knee joints were calculated using 2D (ImageJ) and 3D (Vicon-MX) motion data, respectively. Results: Pearson's correlation coefficients between the two methods were calculated, and significance tests were conducted (${\alpha}=1%$). Correlation coefficients between the two were over 0.98. In Vicon-MX and ImageJ, there is no systematic error by examination of the validity using the Bland-Altman method, and all data are in the 95% limits of agreement. Conclusion: In this study, correlation coefficients are generally high, and the regression line is near the identical line. Therefore, it is considered that motion analysis using ImageJ is a useful tool for evaluation of human movements in various research areas. Application: This result can be utilized as a practical tool to analyze human performance in various fields.

Determination of the Elbow Transverse Joint Using the Helical Axis Concept and its Application to the Development of a Kinematic Arm Model (나선축 개념을 이용한 팔꿈치 관절의 3차원 회전축 측정과 측정 결과를 반영한 인체 팔 모델의 개발)

  • Woo, Bum-Young;Jung, Eui-S.;Yun, Myung-Hwan
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.26 no.1
    • /
    • pp.73-80
    • /
    • 2000
  • To determine the exact direction and location of the human joint in motion is crucial in developing a more accurate human model and producing a more fitting artificial joint. There have been several reports on the biomechanical analysis of the joint to determine the anatomy and movement of joints. However, all the previous researches were made in vitro study, that is, they investigated the passive movement of the joint from cadavers and the suggested location of the joint axis was difficult to make practical applications due to the lack of the direction of joint axis. Also, in many biomechanical models, each joint axis is assumed to lie horizontally or vertically to the adjacent links. Such an assumption causes inherent inaccuracy. In this study, the direction and location of the transverse elbow axis was obtained with respect to the global coordinate system whose origin is on the lateral epicondyle of the humerus. The suggested result based on the global coordinate system lying on the external landmark will be helpful to understand the information of the axis and to make an application. From the experiments conducted for five subjects, the direction and location of the elbow transverse joint was determined for each subject by the helical axis method. A statistical validation was also performed to confirm the result. Finally, the result was applied to develop a simple elbow model which is a part of the kinematic arm model. The simple elbow movement model was developed to validate the significance of the result and the kinematic arm model was able to describe the geometry of any complex linkage system. As a result, the errors incurred from the proposed model were significantly reduced when compared to the ones from the previous approach.

  • PDF

Generation of a Practical Reach Envelope with the Center of Rotation of the Shoulder Joint Considered (견관절의 회전중심점을 고려한 동작가능 영역의 생성)

  • Jung, Eui-S.;Lee, Sang-Kyu
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.25 no.1
    • /
    • pp.56-66
    • /
    • 1999
  • Shoulder joint is the most movable joint in human body with, at least, three degrees of freedom, since there are at least three bones and five joints involved in shoulder movement. Due to the complexity of the shoulder joint and the lack of appropriate anatomical data, modeling of the shoulder joint has been known to be extremely difficult. In many biomechanical models being used, shoulder joint is considered as a fixed point and it is also assumed that the shoulder joint does not noticeably move during the shoulder movement. However, such an assumption is not valid in real applications and causes inaccuracy, especially, in the area of workspace evaluation. The reachable area generated by a human becomes somewhat different from that of current models for those models fail to appropriately reflect the movement of shoulder joint's center of rotation. In this study, the location of the shoulder joint's center of rotation was obtained in relation to the location of humerus, on which a new model for reach envelope generation was developed for workspace evaluation. From the experiments conducted for three subjects, the initial location of the center of rotation was determined for each subject and subsequent changes in the instantaneous center of rotation were drawn as a function of flexion and abduction of the shoulder. Based on the regression analysis, the study suggested a new method for the generation of reach envelope. Comparisons were also made among real reach envelopes obtained from the experiment, the ones from the model, and the ones from the new method suggested in the study. As a result, the prediction errors incurred from the new method were significantly reduced when compared to the ones from the current approach.

  • PDF

Using Skeleton Vector Information and RNN Learning Behavior Recognition Algorithm (스켈레톤 벡터 정보와 RNN 학습을 이용한 행동인식 알고리즘)

  • Kim, Mi-Kyung;Cha, Eui-Young
    • Journal of Broadcast Engineering
    • /
    • v.23 no.5
    • /
    • pp.598-605
    • /
    • 2018
  • Behavior awareness is a technology that recognizes human behavior through data and can be used in applications such as risk behavior through video surveillance systems. Conventional behavior recognition algorithms have been performed using the 2D camera image device or multi-mode sensor or multi-view or 3D equipment. When two-dimensional data was used, the recognition rate was low in the behavior recognition of the three-dimensional space, and other methods were difficult due to the complicated equipment configuration and the expensive additional equipment. In this paper, we propose a method of recognizing human behavior using only CCTV images without additional equipment using only RGB and depth information. First, the skeleton extraction algorithm is applied to extract points of joints and body parts. We apply the equations to transform the vector including the displacement vector and the relational vector, and study the continuous vector data through the RNN model. As a result of applying the learned model to various data sets and confirming the accuracy of the behavior recognition, the performance similar to that of the existing algorithm using the 3D information can be verified only by the 2D information.

Introduction of Whidam's Su-Gi therapy - Focused on Cervical spine (휘담식 수기요법의 소개 - 경추부를 중심으로)

  • Beag, Ji You;Cho, Min Gun;Bae, Jae Ryong;Kang, Han Joo;Kim, Jun Chul;Lee, Jae Heung;Jang, Sang Chul;Ahn, Hun Mo
    • Journal of Korean Medical Ki-Gong Academy
    • /
    • v.17 no.1
    • /
    • pp.24-51
    • /
    • 2017
  • Objective : The purpose of this study is to introduce Whidam's Su-Gi therapy(WST.) as a remarkable traditional manual therapy. Main subject : WST. is a traditional manual therapy from Do-In(導引) An-Kyo(按蹻) that treats disease by controlling Gi(Gi-Gong therapy). It makes treatment effects by pushing Sa-Gi(邪氣) which becomes aggregation-accumulation(積聚) to right places by using pointillage, stroking, and rubbing with doctor's focused intention(意念). The cervical spine connects body and brain, so treating cervical spine could be a foundation of all treatment. Discussion : WST. is a manual therapy that treats not only muscles, nerves, vessels, joints but also Oriental medicine concept-meridian, acupoint and Gi(氣). Conclusions: 1) WST. is a traditional manual therapy using Gi-Gong, 2) WST. changes Sa-Gi(邪氣) into Jung-Gi(正氣), which means curing aggregation-accumulation(積聚), 3) Cervical WST. treats a passage that connects upper and lower parts of human body; heart and brain, and 4) Cervical WST. is a treatment to activate So-Ju-Cheon(小周天), which controls human body immunity.