• Title/Summary/Keyword: Human femur

Search Result 74, Processing Time 0.028 seconds

A Study on Dose Sensitivity according to Position Variance in Extremities Radiation Therapy with Water Bolus (사지의 방사선 치료에 사용하는 water bolus의 적용 시 치료부위의 위치 변화에 따른 방사선 선량분포의 민감도 연구)

  • Seo, Jeong Min
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.199-206
    • /
    • 2015
  • The purpose of this study was to investigate radiation dose sensitivity due to displacement of human extremities in the water bolus box on radiation therapy. Water bolus box and human thigh with femur bone were constructed in computerized radiation therapy planning system to verify the absorbed dose. Two 6MV X-ray beams were irradiated bilaterally into water bolus box and then radiation dose were calculated each situation at displacement of middle axis of thigh from the center in water bolus box to right and left direction. Absorbed dose of thigh and femur bone increased by the distance of displacement. The maximum dose of thigh even increased 20% over than prescribed dose. This is in contrast to conventional concept of dose distribution in water bolus box. Based on this result, displacement of body site in the water bolus box have to be averted during radiation therapy.

Atypical viscous fracture of human femurs

  • Yosibash, Zohar;Mayo, Romina Plitman;Milgrom, Charles
    • Advances in biomechanics and applications
    • /
    • v.1 no.2
    • /
    • pp.77-83
    • /
    • 2014
  • Creep phenomenon at the scale of bone tissue (small specimens) is known to be present and demonstrated for low strains. Here creep is demonstrated on a pair of fresh-frozen human femurs at the organ level at high strains. Under a constant displacement applied on femur's head, surface strains at the upper neck location increase with time until fracture, that occurs within 7-13 seconds. The monotonic increase in strains provides evidence on damage accumulation in the interior (probably damage to the trabeculae) prior to final fracture, a fact that hints on probable damage of the trabecular bone that occurs prior to the catastrophic fracture of the cortical surface layer.

Bioavailability of Starfish Calcium as a Novel Calcium Source (칼슘급원으로서의 불가사리 칼슘의 체내이용성)

  • Lee Yeon Sook;Moon Ji Young;Jang Soo Jung
    • The Korean Journal of Community Living Science
    • /
    • v.16 no.1
    • /
    • pp.135-148
    • /
    • 2005
  • This study was conducted to investigate the bioavailability of calcium derived from starfish as a new calcium source. Four-week old Sprague-Dawley female rats were divided 6 groups. The rats were received experimental diets containing two kinds of Ca sources, CaCO₃ or starfish, and three levels of Ca, low (0.1 %), medium (0.5%) and high (1.0%), respectively, for 6 weeks. The parameters which related to Ca bioavailability were measured : Serum Ca concentration, Alkaline phosphatase(ALP) and GOT activities ; tissue Ca contents, bone dimension and Ca, P, Mg contents; Ca retention and apparent absorption. Starfish Ca-fed rats did not show any difference from CaCO₃-fed rats in terms of growth, food intake and FER. Serum Ca, ALP and GOT activities as well as tissue Ca contents were not different between CaCO₃- and starfish Ca-fed groups. Although dimension of femur and lumbar was not different between CaCO₃- and starfish Ca-fed rats, ash content was high in starfish Ca-fed rats. Ca and P contents of femur and lumbar were not different between both groups. Starfish Ca-fed groups showed higher Mg contents than CaCO₃-fed groups in both femur and lumbar. Ca absorption rate and retention rate were significantly higher in starfish Ca-fed rats. These results indicate that Ca derived starfish did not show any negative effect on growth and Ca metabolism of rats compared to calcium carbonate. Starfish Ca can be recommended as a good Ca source on the basis of higher Ca absorption and bioavailability.

  • PDF

Modeling and Simulation of Human Knee Joint in Three Dimension By Using the Method of Optimal Triangular Patches (최단 거리 삼각형 패치 형성법을 이용한 무릎 관절의 3차원 형상 모델링과 시뮬레이션)

  • Moon, Byung-Young;Son, Kwon;Kim, Kwang-Hoon;Seo, Jung-Tak
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.12
    • /
    • pp.205-212
    • /
    • 2003
  • Many people are exposed to accidents by vehicles or sports. The most frequent injuries by these accidents is concerned with a knee joint. The three-dimensional surface model of a knee is needed for dynamic analysis of knee motion and knee reconstruction. three-dimensional motion data of a knee joint were obtained using X-ray and precise magnetic sensors. The surface data of a femur and a tibia were obtained using cross-sectional pictures by CT. The three-dimensional surface models of a femur and a tibia were made by the method of optimal triangular patch. Using obtained motion data, we simulated the motion of three-dimensional knee joint model.

Effects of Chitosan on Mineral Metabolism in Rats Exposed to Cadmium (카드뮴 투여 흰쥐에서 키토산 섭취가 무기질 대사에 미치는 효과)

  • Lee, Yeon-Sook;Kim, Yun-Ah;Jang, Soo-Jung;Park, Mi-Na
    • The Korean Journal of Community Living Science
    • /
    • v.19 no.1
    • /
    • pp.75-85
    • /
    • 2008
  • This study investigated the effects of chitosan on mineral metabolism in rats exposed to cadmium by oral administration. Six week-old Sprague-Dawley rats were divided into eight groups. Four groups were fed AIN-93G based 3% ${\alpha}$-cellulose diets and the other four groups were fed 3% chitosan diets for four weeks with the oral administration of 0, 0.5, 1.0, 2.0 mg Cd/2ml distilled water three times per week, respectively. The essential mineral contents of serum, liver, kidney and bone (femur and lumbar), and the excretion of calcium in feces and urine were determined. There was no significant difference in weight gain and food intake among groups. The cadmium administration significantly decreased calcium in serum, iron in blood, calcium and iron in liver and iron contents in kidney. In contrast, calcium and zinc contents in kidney increased by the administration of cadmium. The weight, length and breaking forces of the femur and lumbar were not significantly different due to cadmium administration and chitosan among the groups. The fecal excretion of calcium was increased by the administration of cadmium. On the other hand, calcium absorption and the absorption rate were decreased by Cd administration. In the groups without Cd administered (N, N-Chi groups), chitosan significantly decreased the absorption rate of calcium by increasing the excretion in feces (p<0.05). These results suggest that cadmium administration may facilitate the decline of essential minerals in rats and also, chitosan may have a conflicting effect between cadmium and the essential minerals of tissues.

  • PDF

Ceramic - Polymer Nanocomposite: Alternate Choice of Bone

  • Sarkar, Debasish;Chu, Min-Cheol;Cho, Seong-Jai
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.6
    • /
    • pp.309-319
    • /
    • 2008
  • This study evaluates a range of materials that may be used to design prostheses for bone. It is found that nanocrystalline ceramic-polymer composite could be the best material for prosthetic bone with respect to biocompatibility, morphology, chemistry, and compatibility with the piezoelectric and mechanical behavior of long human bones, such as the femur.

Extracting 3D Geometry Parameters of Hip Joint for Designing a Custom-Made Hip Implant (맞춤형 인공관절 설계를 위한 인체 고관절의 3차원 형상 정보 추출)

  • Seo, Jeong-Woo;Jun, Yong-Tae
    • Korean Journal of Computational Design and Engineering
    • /
    • v.13 no.3
    • /
    • pp.200-208
    • /
    • 2008
  • Total Hip Replacement(THR) is a surgical procedure that replaces a diseased hip joint with a prosthesis. A plastic or metal cup forms the socket, and the head of the femur is replaced by a metal ball on a stem placed inside the femur. Due to the various types and shapes of human hip joint of every individual, a selected commercial implant sometimes may not be the best-fit to a patient, or it cannot be applied because of its discrepancy. Hence extracting geometry parameters of hip joint is one of the most crucial processes in designing custom-made implants. This paper describes the framework of a methodology to extract the geometric parameters of the hip joint. The parameters include anatomical axis, femoral head, head offset length, femoral neck, neck shaft angle, anteversion, acetabulum, and canal flare index. The proposed system automatically recommends the size and shape of a custom-made hip implant with respect to the patient's individual anatomy from 3D models of hip structures. The proposed procedure creating these custom-made implants with some typical examples is precisely presented and discussed in this paper.

The Comparison of Bonded/Unbonded Stem-Cement Interface in Total Hip Replacement -Experimental Study (인공 고관절 전치환술에서 주대-시멘트 경계층의 접착 및 비접착 고정술의 비교를 위한 실험적 연구)

  • Han, J.H.;Yoon, Y.S.;Lee, J.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.951-955
    • /
    • 2001
  • The experimental comparison between bonded and unbonded types stem-cement interface was carried out on axisymmetric stem-cement-aluminum model of the femoral component of a total hip replacement. Human femur was modeled in non-tapered and tapered($7.5^{\circ}$) aluminum hollow cylinders to emulate the diaphyseal and metaphyseal segments of the femur. For unbonded type, we tested stems with three different taper angles($5^{\circ},\;7.5^{\circ},\;10^{\circ}$). In every case, the cement-aluminum interface was designed to endure 8MPa shear strength. (a measured value at cement-bone interface) We tested aluminum models under axial loading for both cases. As an experimental result, it was found that unbonded stem sustained more axial load as bonded stem in both cases, diaphyseal and metaphyseal models. The unbonded types failed in cement mantle under axial compressive load, while the bonded ones failed in shear at cement-aluminum interface. These results suggest that a polished stem will sustain much higher axial load than a roughened stem. And a polished stem will make more stable cement-bone interface that may promote better osteosythesis around the stem.

  • PDF

Management of Osteoporosis Medication after Osteoporotic Fracture

  • Young Kwang Oh;Nam Hoon Moon;Won Chul Shin
    • Hip & pelvis
    • /
    • v.34 no.4
    • /
    • pp.191-202
    • /
    • 2022
  • The aim of this study was to provide helpful information for use in selection of an appropriate medication after osteoporotic fractures through conduct of a literature review. In addition, a review of the recommendations of several societies for prevention of subsequent fractures was performed and the appropriate choice of medication for treatment of atypical femur fractures was examined. Clinical perspective was obtained and an updated search of literature was conducted across PubMed and MEDLINE and relevant articles were selected. The articles were selected manually according to relevance, and the references for identified articles and reviews were also evaluated for relevance. The following areas are reviewed: Commonly prescribed osteoporosis medications: BPs (bisphosphonates), denosumab, and SERMs (selective estrogen receptor modulators) in antiresorptive medications and recombinant human parathyroid hormone teriparatide, recently approved Romosuzumab in anabolic agents, clinical practice guidelines for the management of osteoporosis, osteoporotic fracture, and atypical femur fracture. Most medications for treatment of osteoporosis do not delay fracture healing and the positive effect of teriparatide on fracture healing has been confirmed. In cases where an osteoporotic fracture is diagnosed, risk assessment should be performed for selection of very high-risk patients in order to prevent subsequent fractures, and administration of anabolic agents is recommended.