• 제목/요약/키워드: Human Muscle

검색결과 954건 처리시간 0.028초

세 가지 주요 검도 공격 동작에서의 근-골격계 응력과 번형률 해석에 관한 연구 (A Study on the Stress and Strain Analysis of Human Muscle Skeletal Model in Kendo Three Typical Attack Motions)

  • 이중현;이영신
    • 한국정밀공학회지
    • /
    • 제25권9호
    • /
    • pp.126-134
    • /
    • 2008
  • Kendo is one of the popular sports in modem life. Head, wrist and thrust attack are the fast skill to get a score on a match. Human muscle skeletal model was developed for biomechanical study. The human model was consists with 19 bone-skeleton and 122 muscles. Muscle number of upper limb, trunk and lower limb part are 28, 60, 34 respectively. Bone was modeled with 3D beam element and muscle was modeled with spar element. For upper limb muscle modelling, rectus abdominis, trapezius, deltoideus, biceps brachii, triceps brachii muscle and other main muscles were considered. Lower limb muscle was modeled with gastrocenemius, gluteus maximus, gluteus medius and related muscles. The biomechanical stress and strain analysis of human muscle was conducted by proposed human bone-muscle finite element analysis model under head, wrist and thrust attack for kendo training.

인체 근육 구조를 적용한 남성 테일러드 재킷 디자인 (Construction of men's tailored jackets - Incorporating human muscle structure in fashion design -)

  • 이한철;이연희
    • 복식문화연구
    • /
    • 제26권6호
    • /
    • pp.934-950
    • /
    • 2018
  • This study suggests a new perspective for designing men's tailored jackets by more carefully considering human muscle structure. For this study, we examined research regarding the construction of the tailored jacket that is based on costume history references, as well as research regarding human muscle structure that is based on human anatomy references and the analysis of recent fashion designs illustrating the human body image. Based on this research, we developed various tailored constructions that account for human muscle structure. These constructions are applied primarily to the backs of four tailored jackets, as the back of the jacket needs a mechanism to accommodate the wearer's movement. The following conclusions have been derived from the study: First, by developing the tailored garment structure that accounts for the muscle structure of the human body, we suggest a new design direction for tailored garments. Second, we propose a new type of tailored jacket structure for the back of the jacket that incorporates an artificial muscle structure to accommodate the wearer's activities. This new type of jacket indicates the potential for designs that use structure, particularly the structure of the human body. Finally, by using the embroidery technique, we changed the texture of the material into the shape of human muscle. Thus, we propose a design that uses three-dimensional volume to accounts for the shape of human body tissue.

검도 머리치기 동작의 인체 근골격 모델개발 및 응력해석 (Development on Human Muscle Skeletal Model and Stress Analysis of Kumdo Head Hitting Motion)

  • 이중현;이세훈;이영신
    • 한국정밀공학회지
    • /
    • 제24권11호
    • /
    • pp.116-125
    • /
    • 2007
  • Human muscle skeletal model was developed for biomechanical study. The human model was consists with 19 bone-skeleton and 122 muscles. Muscle number of upper limb, trunk and lower limb part are 28, 60, 34 respectively. Bone was modeled with 3D beam element and muscle was modeled with spar element. For upper limb muscle modelling, rectus abdominis, trapezius, deltoideus, biceps brachii, triceps brachii muscle and other main muscles were considered. Lower limb muscle was modeled with gastrocenemius, gluteus maximus, gluteus medius and related muscles. The biomechanical stress and strain analysis of human was conducted by proposed finite element analysis model under Kumdo head hitting motion. In this study structural analysis has been performed in order to investigate the human body impact by Kumdo head hitting motion. As the results, the analytical displacement, stress and strain of human body are presented.

인체 전경골근의 수의적 수축시 선행 동심성 근수축이 항정상태 등척성 근력에 미치는 영향 (Force Depression Following Active Muscle Shortening during Voluntary Contraction in Human Tibialis Anterior Muscle)

  • 이해동;이성철
    • 한국운동역학회지
    • /
    • 제16권3호
    • /
    • pp.75-83
    • /
    • 2006
  • The purpose of this study was to investigate steady-state force depression following active muscle shortening in human tibialis anterior muscle during voluntary contractions. Subjects (n = 7; age $24{\sim}39$ years; 7 males) performed isometric reference contractions and isometric-shortening-isometric contractions, using maximal voluntary effort. Force depression was assessed by comparing the steady-state isometric torque produced following active muscle shortening with the purely isometric reference torque obtained at the corresponding joint angle. In order to test for effects of the shortening conditions on the steady-state force depression, the speed of shortening were changed systematically in a random order but balanced design. Ankle dorsiflexion torque and joint angle were continuously measured using a dynamometer. During voluntary contractions, muscle activation of the tibialis anterior and the medical gastrocnemius was recorded using surface electromyography. Force depression during voluntary contractions, with a constant level of muscle activation, was 12 %, on average over all subjects. Force depression was independent of the speeds of shortening ($13.8{\pm}2.9%$, $10.3{\pm}2.6%$ for 15 and 45 deg/sec over 15 deg of shortening, respectively). The results of this study suggest that steady-state force depression is a basic property of voluntarily-contracting human skeletal muscle and has functional implication to human movements.

Study on Hand Greater Yang Skin from the Viewpoint of Human Anatomy

  • Park, Kyoung-Sik
    • 대한한의학회지
    • /
    • 제39권4호
    • /
    • pp.121-125
    • /
    • 2018
  • Objectives: This study was carried out to analyse Hand Greater Yang Skin in human. Methods: Hand Greater Yang meridian was labeled with latex in the body surface of the cadaver. And subsequently body among superficial fascia and muscular layer were dissected in order to observe internal structures. Results : A depth of Skin encompasses a common integument and a immediately below superficial fascia, this study established Skin boundary with adjacent structures such as relative muscle, tendon as compass. The Skin area of the Hand Greater Yang in human are as follows: The skin close to 0.1chon ulnad of $5^{th}$ nail angle, ulnad base of $5^{th}$ phalanx, ulnad head of $5^{th}$ metacapus(relevant muscle: abductor digiti minimi muscle), ulnad of hamate, tip of ulnar styloid process(extensor carpi ulnaris tendon), radiad of ulnar styloid process, 2cm below midpoint between Sohae and Yanggok(extensor carpi ulnaris), between medial epicondyle of humerus and olecranon of ulnar(ulnar nerve), The skin close to deltoid muscle, trapezius muscle, platysma muscle, inner muscles such as teres major muscle, infraspinatus muscle, supraspinatus muscle, levator scapulae muscle, splenius cervicis muscle, splenius capitis muscle, sternocleidomastoid muscle, digastric muscle, stylohyoid muscle, zygomaticus major muscle, auricularis anterior muscle. Conclusions: The Skin area of the Hand Greater Yang from the anatomical viewpoint seems to be the skin area outside the superficial fascia or muscles involved in the pathway of Hand Greater Yang meridian, collateral meridian, meridian muscle, with the condition that we consider adjacent skins.

인체 하지부 근골격계 모델 및 의자에서 일어서는 동작 시 근력 예측 (A Musculoskeletal Model of a Human Lower Extremity and Estimation of Muscle Forces while Rising from a Seated Position)

  • 조영남;유홍희
    • 한국소음진동공학회논문집
    • /
    • 제22권6호
    • /
    • pp.502-508
    • /
    • 2012
  • An analytical model for a human body is important to predict muscle and joint forces. Because it is difficult to estimate muscle or joint forces from a human body, the objective of this study is the development of a reliable analytical model for a human body to evaluate the lower extremity muscle and joint forces. The musculoskeletal system of the human lower extremity is modeled as a multibody system employing the Hill-type muscle model. Muscle forces are determined to minimize energy consumption, and we assume that motion is constrained in the sagittal plane. Muscle forces are calculated through an equilibrium analysis while rising from a seated position. The musculoskeletal model consists of four segments. Each segment is a rigid body and connected by frictionless revolute joints. Muscles of the lower extremity are simplified to seven muscles with those that are not related to the sagittal plane motion are ignored. Muscles that play a similar role are combined together. The results of the present study are compared with experimental results to validate the lower extremity model and the assumptions of the present study.

Anatomical Study on the Heart Meridian Muscle in Human

  • Park Kyoung-Sik
    • 대한한의학회지
    • /
    • 제26권1호
    • /
    • pp.11-17
    • /
    • 2005
  • This study was carried out to identify the components of the human heart meridian muscle, the regional muscle group being divided into outer, middle, and inner layers. The inner parts of the body surface were opened widely to demonstrate muscles, nerves, blood vessels and to expose the inner structure of the heart meridian muscle in the order of layers. We obtained the following results; $\cdot$ The heart meridian muscle is composed of muscles, nerves and blood vessels. $\cdot$ In human anatomy, the difference between terms is present (that is, between nerves or blood vessels which control the meridian muscle and those which pass near by). $\cdot$ The inner composition of the heart meridian muscle in the human arm is as follows: 1) Muscle H-l: latissimus dorsi muscle tendon, teres major muscle, coracobrachialis muscle H-2: biceps brachialis muscle, triceps brachialis muscle, brachialis muscle H-3: pronator teres muscle and brachialis muscle H-4: palmar carpal ligament and flexor ulnaris tendon H-5: palmar carpal ligament & flexor retinaculum, tissue between flexor carpi ulnaris tendon and flexor digitorum superficialis tendon, flexor digitorum profundus tendon H-6: palmar carpal ligament & flexor retinaculum, flexor carpi ulnaris tendon H-7: palmar carpal ligament & flexor retinaculum, tissue between flexor carpi ulnaris tendon and flexor digitorum superficial is tendon, flexor digitorum profundus tendon H-8: palmar aponeurosis, 4th lumbrical muscle, dorsal & palmar interrosseous muscle H-9: dorsal fascia, radiad of extensor digiti minimi tendon & extensor digitorum tendon 2) Blood vessel H-1: axillary artery, posterior circumflex humeral artery H-2: basilic vein, brachial artery H-3: basilic vein, inferior ulnar collateral artery, brachial artery H-4: ulnar artery H-5: ulnar artery H-6: ulnar artery H-7: ulnar artery H-8: palmar digital artery H-9: dorsal digital vein, the dorsal branch of palmar digital artery 3) Nerve H-1: medial antebrachial cutaneous nerve, median n., ulnar n., radial n., musculocutaneous n., axillary nerve H-2: median nerve, ulnar n., medial antebrachial cutaneous n., the branch of muscular cutaneous nerve H-3: median nerve, medial antebrachial cutaneous nerve H-4: medial antebrachial cutaneous nerve, ulnar nerve H-5: ulnar nerve H-6: ulnar nerve H-7: ulnar nerve H-8: superficial branch of ulnar nerve H-9: dorsal digital branch of ulnar nerve.

  • PDF

근 부피 센서를 이용한 인체 팔꿈치 관절의 동작 토크 추정 (Torque Estimation of the Human Elbow Joint using the MVS (Muscle Volume Sensor))

  • 이희돈;임동환;김완수;한정수;한창수;안재용
    • 한국정밀공학회지
    • /
    • 제30권6호
    • /
    • pp.650-657
    • /
    • 2013
  • This study uses a muscle activation sensor and elbow joint model to develop an estimation algorithm for human elbow joint torque for use in a human-robot interface. A modular-type MVS (Muscle Volume Sensor) and calibration algorithm are developed to measure the muscle activation signal, which is represented through the normalization of the calibrated signal of the MVS. A Hill-type model is applied to the muscle activation signal and the kinematic model of the muscle can be used to estimate the joint torques. Experiments were performed to evaluate the performance of the proposed algorithm by isotonic contraction motion using the KIN-COM$^{(R)}$ equipment at 5, 10, and 15Nm. The algorithm and its feasibility for use as a human-robot interface are verified by comparing the joint load condition and the torque estimated by the algorithm.

Archvillin C-Terminus-Binding Proteins in Human Skeletal Muscle

  • Chang, Goo-Rak
    • 대한의생명과학회지
    • /
    • 제16권4호
    • /
    • pp.207-212
    • /
    • 2010
  • Archivillin, a muscle-specific isoform of supervillin, is a component of the costameric cytoskeleton of muscle cells. The purpose of this study was to determine which protein in the skeletal muscle collaborates with archvillin C-terminus. For this purpose, a yeast two-hybrid screening of human skeletal muscle cDNA library was performed using the C-terminal region of archvillin as bait. This study shows that seven human skeletal muscle proteins, namely, nebulin, xeplin, archvillin, GAPDH, TOX4, PITRM1, and YME1L1 interact with archvillin C-terminus. Especially, xeplin is a newly discovered protein interacts with archvillin C-terminus. These results indicate that archvillin C-terminus acts as a bridge between nebulin and xeplin at costameres. Archvillin C-terminal region interacts with nebulin C-terminal region at Z-discs and interacts with xeplin at the vicinity of sarcolemma. I propose that these interactions may contribute to formation of costameric structure and muscle contraction.

인간-기계 인터페이스를 위한 근 부피 센서 개발 (Development of the MVS (Muscle Volume Sensor) for Human-Machine Interface)

  • 임동환;이희돈;김완수;한정수;한창수;안재용
    • 한국정밀공학회지
    • /
    • 제30권8호
    • /
    • pp.870-877
    • /
    • 2013
  • There has been much recent research interest in developing numerous kinds of human-machine interface. This field currently requires more accurate and reliable sensing systems to detect the intended human motion. Most conventional human-machine interface use electromyography (EMG) sensors to detect the intended motion. However, EMG sensors have a number of disadvantages and, as a consequence, the human-machine interface is difficult to use. This study describes a muscle volume sensor (MVS) that has been developed to measure variation in the outline of a muscle, for use as a human-machine interface. We developed an algorithm to calibrate the system, and the feasibility of using MVS for detecting muscular activity was demonstrated experimentally. We evaluated the performance of the MVS via isotonic contraction using the KIN-COM$^{(R)}$ equipment at torques of 5, 10, and 15 Nm.