The Effect of Homnis Placenta Herbal Acupuncture on Reducing Expression of LPS-induced Arthritis Model as an Anti-inflammatory Agent (자하차약침(紫何車藥針)의 항염증능(亢炎症能)이 LPS 유발 관절염(關節炎) 치료(治療)에 미치는 영향(影響))

  • Park, Ki-Bum;Baek, Seung-Tae;Lee, Seung-Deok;Kim, Kyung-Ho;Kim, Kap-Sung
    • Journal of Acupuncture Research
    • /
    • v.23 no.6
    • /
    • pp.103-115
    • /
    • 2006
  • Objectives : Rheumatoid arthritis(RA) is a systemic & a chronic inflammatory autoimmune disease . A chronic , locally destructive inflammmatory reaction in human is examplified by the synovitis present in some connective tissue disorder. The presence of a number of cytokines, $TNF-{\alpha}$, iNOS & expression of nitric oxide, NF-kB p65 activation implies an important role of cellular immune response in RA inflammatory reaction. This study was designed to evaluate on the effects of the Homnis Placenta herbal acupuncture on EX-LE201 & ST 35 reducing expression of LPS-induced arthritis model in mice. Materials and Methods : Homnis Placenta herbal acupuncture was inserted into 10 rats induced rheumatoid arthritis. The acupunctures were injected into the EX-LE201 and ST35 points. Such indexes were measured the inhibition of inducible nitric oxide synthase(iNOS) expression, nitric oxide(NO) production in vitro experiment and Tumor Necrosis $Factor-{\alpha}(TNF-{\alpha})$ & Nuclear Factor kappa $B(NF-{\kappa}B)$ p65 activation, synovial hyperplasia, angiogenesis and fibrosis in synovial membrane of knee joint of mice in vivo experiment. Results : 1.Homnis Placenta Herbal acupuncture inhibited iNOS mRNA and NO in RAW 264.7 cell of LPS-induced rheumatoid arthritis in a dose dependent manner. 2.Homnis Placenta Herbal acupuncture also showed significant inhibition of $TNF-{\alpha}$ & $NF-{\kappa}B$ p65, activation, synovial hyperplasia, angiogenesis and fibrosis in synovial membrane of knee joint of mice. Conclusion : These results suggest that Homnis Placenta Herbal acupuncture has an therapeutic effects on LPS induced-rheumatoid arthritis by inhibiting $TNF-{\alpha}$ activation.

  • PDF

Usefulness Evaluation of Merchant Auxiliary Equipment of Body Type Changing Suitable for X-ray Table Integral Type (체형변화에 적합한 X-선 검사대 일체형 Merchant 보조장비의 유용성 평가)

  • Seoung, Youl-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2773-2779
    • /
    • 2013
  • The purpose of this study was to evaluate of the usefulness and to develop new auxiliary equipment that can bending angle of the bone of the knee various depending on the thickness of the thigh of the human. The subjects agreed for research purposes and were selected from normal person who do not have past knee-related diseases and grouped thin group A and thick group B for the thigh. We set in order to obtain images in the axial direction of the bones of the knee, $35^{\circ}$ to increase by $5^{\circ}$ angle of knee flexion, $45^{\circ}$, to $55^{\circ}$, and we performed combinations of 9 tests by incident angle X-ray per each angle, $40^{\circ}$, $50^{\circ}$ and $60^{\circ}$. As a result, we have developed an Merchant auxillary equipment of X-ray table integral type in radiographic images which was easy to use and could take images of various integral knee joint angles adjusting different body types. Using the auxiliary equipment, in the case of X-ray incident angle $50^{\circ}$ and $60^{\circ}$ with the knee flexion angle of $40^{\circ}$ in group A, and in group B, Knee flexion angle of $45^{\circ}$ and $35^{\circ}$, the X-ray incident angle at $60^{\circ}$, excellent images were derived. Future, it would be very useful in the examination of patients with a variety of body types.

Ultrastructural Study on the Development of the Synovial Membrane in Human Fetuses (인태아(人胎兒) 활액막세포(滑液膜細胞)의 전자현미경적(電子顯微鏡的) 연구(硏究))

  • Yoon, Jae-Rhyong;Chun, Cheol-Hong;Ahn, Kyu-Youn
    • Applied Microscopy
    • /
    • v.24 no.1
    • /
    • pp.86-101
    • /
    • 1994
  • The development of synovial membrane from knee joint was studied by electron microscope in human fetuses ranging from 20mm to 260mm crown rump length (40days to 30weeks of gestational age). At 40mm fetus, developing synovial tissue was observed in homogenous interzone as a vascular mesenchyme around the periphery. The primitive joint space was appeared after the intermediate layer of the interzone in direct contact with chondrogenic layer at 60mm fetus. Differentiation of the synovial membrane coincided with clarification of the joint cauity. When dilatation of the synovial cavity occurred, the two types of synovial cells were well endowed with rough endoplasmic reticulum. At 100mm fetus, type A cells with a markedly attenuated cytoplasm were found as well as those cells which contained pinocytotic vesicles and vacuoles. By 150-200mm fetuses a majority of the intimal cells were type B. These cells were characterized by abundant rough endoplasmic reticulum and well developed Golgi complex. In contrast, A-type cell had numerous filopodia, pinocytotic vesicles lysosomes, and large vacuoles containing amorphous material. At 260mm fetus, the intimal cells were well developed and plentiful. The most marked difference between the synovial membrane of full-term fetus and adult was the large amount of collagen in the latter. During fetal period, the B-cells were most numerous cell type in the intimal cells. The B-cells were clearly distinguishable from the A-cells by their content of extensive rough endoplasmic reticulum and well developed Golgi complex.

  • PDF

Effect of the Non-Elastic Taping Method of Controlling Internal Hip Joint Rotation on Hip Muscle Activity: A Preliminary Study (엉덩관절 안쪽돌림 조절을 위한 비탄력 테이핑 방법이 엉덩관절 근활성도에 미치는 영향 -예비연구-)

  • Song-Ui Bae;Ju-Hyeon Jung;Dong-Chul Moon
    • PNF and Movement
    • /
    • v.21 no.3
    • /
    • pp.281-289
    • /
    • 2023
  • Purpose: This study investigated the effects of the non-elastic taping method for controlling internal hip joint rotation on internal and external hip rotator muscle activity in healthy people. Methods: In this study, 18 healthy volunteers were instructed to perform the small knee bending (SKB) test. All participants completed the test following two methods (using non-elastic taping and not using taping). Muscle activation during the two methods was measured using a surface electromyography (EMG) device. Surface EMG data were collected from the gluteus medius, gluteus maximus, and tensor fasciae femoris muscles while performing the SKB test with and without non-elastic taping. Results: Muscle activity in the gluteus maximus was significantly higher during the SKB test with non-elastic taping than during the conventional SKB test with taping (p < 0.05). Tensor fasciae latae muscle activity was lower during the SKB test with non-elastic taping than during the conventional SKB test (p < 0.05). Conclusion: The findings suggest that the non-elastic taping method for controlling internal hip joint rotation effectively activates the hip's external rotator muscles and minimizes unwanted internal rotator muscle use during the SKB test. Therefore, the non-elastic taping method for controlling internal hip joint rotation could be an effective intervention for those who cannot control the internal rotation of their hips.

Prototype of Fall Impact Protective Pants for Elderly Women (노년 여성을 위한 낙상충격 보호팬츠 디자인 프로토타입)

  • Park, Jung Hyun;Lee, Jeong Ran
    • Journal of the Korean Society of Costume
    • /
    • v.66 no.4
    • /
    • pp.45-60
    • /
    • 2016
  • Elderly women have a high risk of falling down in their daily lives. The purpose of this study is to develop protective pants for elderly women, which will mitigate the impact of falls, and play a major role in reducing injuries. The two types of design were proposed for development of protective pants by selecting pad insertion point and inserting lining for keeping pad in place through the checklist to investigate from the interviews with the medical workers and the investigation of the user requirement. Design A has protective pads in the hip, hip joint, and knee, while design B has protective pads in the hip and hip joint area. For the impact absorbing material, CR (chloroprene rubber) foam was selected for its flexibility, lightness, and impact absorbing capacity, and its pad shapes were designed to produce much flexibility in consideration of the activity and human body fitness of the wearers. Three kinds of pad types, which are the cut type, the porous type, and the honeycomb type, were proposed, and were manufactured to fit into the protective parts according to their design types.

The Effect of Ankle stability exercise and Mobilization on Hip Muscle Strength and Gait in Patients with Acute Ankle Sprain (급성 발목 염좌에 대한 족관절의 관절가동술이 보행과 고관절 근력에 미치는 영향)

  • Jung, Sang-mo;Lee, Jae-nam;Jeon, Jae-hyung
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.24 no.1
    • /
    • pp.39-46
    • /
    • 2018
  • Background: In most human lives, 80 percent have problems with the ankle and can be solved with a treatment that is objective in proper assessment. Discrepacts in the ankle are also associated with walking patterns and affect hip and knee joints. An evaluation of hip flexion and extensor muscles was performed to check the strength of hip joints after ankle sprain patients application of arthesis. Methods: In the hospital in Bucheon, 20 outpatients who visited the hospital for treatment with ankle sprain were tested with 10 male and 10 female patients. The criteria for selection of the study subjects were randomly divided into those with joint movement techniques applied to the ankle joints and those with conservative physical therapy. Results: In applying arthrography and preservation physical therapy to patients with ankle sprain, a difference in muscle strength between hip flexion and extensor was noted in post-evaluation comparisons. There were significant differences in the assessment of walking speed and walking time between the two counties in the gait analysis assessment (p<.05). Conclusion: Studies have shown that applying arthrography to people with ankle sprain has a greater therapeutic effect than using conservative physical therapy.

Time-frequency Analysis of Vibroarthrographic Signals for Non-invasive Diagnosis of Articular Pathology (비침습적 관절질환 진단을 위한 관절음의 시주파수 분석)

  • Kim, Keo-Sik;Song, Chul-Gyu;Seo, Jeong-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.4
    • /
    • pp.729-734
    • /
    • 2008
  • Vibroarthrographic(VAG) signals, emitted by human knee joints, are non-stationary and multi-component in nature and time-frequency distributions(TFD) provide powerful means to analyze such signals. The objective of this paper is to classify VAG signals, generated during joint movement, into two groups(normal and patient group) using the characteristic parameters extracted by time-frequency transform, and to evaluate the classification accuracy. Noise within TFD was reduced by singular value decomposition and back-propagation neural network(BPNN) was used for classifying VAG signals. The characteristic parameters consist of the energy parameter, energy spread parameter, frequency parameter, frequency spread parameter by Wigner-Ville distribution and the amplitude of frequency distribution, the mean and the median frequency by fast Fourier transform. Totally 1408 segments(normal 1031, patient 377) were used for training and evaluating BPNN. As a result, the average value of the classification accuracy was 92.3(standard deviation ${\pm}0.9$)%. The proposed method was independent of clinical information, and showed good potential for non-invasive diagnosis and monitoring of joint disorders such as osteoarthritis and chondromalacia patella.

A Study on the Gait Analysis for Initial Posture of a Biped Robot (이족 보행 로봇의 초기 자세에 따른 걸음새 해석에 관한 연구)

  • Noh, Kyung-Kon;Kim, Jin-Geol
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.301-303
    • /
    • 2001
  • This paper deals with the biped robot gait on changing the initial postures. Gait of a biped robot depends on the constraints of mechanical kinematics and initial posture. Also biped robot's dynamic walking stability is investigated by ZMP(Zero Moment Point). The path trajectory. with the knee joint bent like a human, is generated and applied with the above considerations. To decrease trajectory tracking error, in this paper, a new initial posture similar to bird's case is proposed and realized with the real robot.

  • PDF

Walking motion capture system for the biped-walking robot (이족 보행로봇의 걸음새구현을 위한 모셔냅쳐 시스템)

  • 최형식;김영식;전대원;김명훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.114-117
    • /
    • 2000
  • We developed a motion capture system to get angle data of human joints in walking mode. The data are used to coordinate the biped-walking robot developed in our laboratory. A pair of motion capture system is composed of three links with the ankle, knee, and pelvis joints. The system has six axes attached with potentiometers. We used an A/D converter was used to get digital data from joint angles. We filterd the data using the Butterworth 4th order digital filter, and simulated walking motion based on the data using the Matlab.

  • PDF

Walking Pattern Analysis for Reducing Trajectory Tracking Error in a Biped Robot (이족보행로봇의 궤적 추종 오차 감소를 위한 걸음새 분석)

  • 노경곤;공정식;김진걸
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.10
    • /
    • pp.890-897
    • /
    • 2002
  • This paper deals with the reduction of trajectory tracking error by changing the initial postures of a biped robot. Gait of a biped robot depends on the constraints of mechanical kinematics and the initial states including the posture. Also the dynamic walking stability in a biped robot system is analyzed by zero moment point(ZMP) among the stabilization indices. Path trajectory, in which knee joint is bent forward like human's cases, is applied to most cases considered with above conditions. A new initial posture, which is similar to bird's gait, is proposed to decrease trajectory tracking error and it is verified through real experimental results.