• Title/Summary/Keyword: Human Condition

Search Result 2,397, Processing Time 0.032 seconds

Inhomogeneity correction in on-line dosimetry using transmission dose (투과선량을 이용한 온라인 선량측정에서 불균질조직에 대한 선량 보정)

  • Wu, Hong-Gyun;Huh, Soon-Nyung;Lee, Hyoung-Koo;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.139-147
    • /
    • 1998
  • Purpose: Tissue inhomogeneity such as lung affects tumor dose as well as transmission dose in new concept of on-line dosimetry which estimates tumor dose from transmission dose using the new algorithm. This study was carried out to confirm accuracy of correction by tissue density in tumor dose estimation utilizing transmission dose. Methods: Cork phantom (CP, density $0.202\;gm/cm^3$) having similar density with lung parenchyme and polystyrene phantom (PP, density $1.040\;gm/cm^3$) having similar density with soft tissue were used. Dose measurement was carried out under condition simulating human chest. On simulating AP-PA irradiation, PPs with 3 cm thickness were placed above and below CP, which had thickness of 5, 10, and 20 cm. On simulating lateral irradiation, 6 cm thickness of PP was placed between two 10 cm thickness CPs additional 3 cm thick PP was placed to both lateral sides. 4, 6, and 10 MV x-ray were used. Field size was in the range of $3{\times}3$ cm through $20{\times}20$ cm, and phantom-chamber distance (PCD) was 10 to 50 cm. Above result was compared with another sets of data with equivalent thickness of PP which was corrected by density. Result: When transmission dose of PP was compared with equivalent thickness of CP which was corrected with density, the average error was 0.18 (${\pm}0.27$) % for 4 MV, 0.10 (${\pm}0.43$) % for 6 MV, and 0.33 (${\pm}0.30$) % for 10 MV with CP having thickness of 5 cm. When CP was 10 cm thick, the error was 0.23 (${\pm}0.73$) %, 0.05 (${\pm}0.57$) %, and 0.04 (${\pm}0.40$) %, while for 20 cm, error was 0.55 (${\pm}0.36$) %, 0.34 (${\pm}0.27$) %, and 0.34 (${\pm}0.18$) % for corresponding energy. With lateral irradiation model, difference was 1.15 (${\pm}1.86$) %, 0.90 (${\pm}1.43$) %, and 0.86 (${\pm}1.01$) % for corresponding energy. Relatively large difference was found in case of PCD having value of 10 cm. Omitting PCD with 10 cm, the difference was reduced to 0.47 (${\pm}$1.17) %, 0.42 (${\pm}$0.96) %, and 0.55 (${\pm}$0.77) % for corresponding energy. Conclusion When tissue inhomogeneity such as lung is in tract of x-ray beam, tumor dose could be calculated from transmission dose after correction utilizing tissue density.

  • PDF

An Interpretation of the Korean Fairy-Tale "Borrowed Fortune From Heaven" From the Perspective of Analytical Psychology (한국민담 <하늘에서 빌려온 복>에 대한 분석심리학적 이해)

  • Kihong Baek
    • Sim-seong Yeon-gu
    • /
    • v.38 no.1
    • /
    • pp.112-160
    • /
    • 2023
  • This study examined the Korean folklore "Borrowed Fortune from Heaven" from the perspective of Analytical Psychology, considering it a manifestation of the human psyche, and tried to gain a deeper understanding of what happens in our mind. Through the exploration, the researcher was able to re-identify the ongoing psychological process operating in the depths of our mind, pertaining to the emergence of a new dimension of consciousness. Particularly the researcher was able to gain some insights into how the potential psychic elements for the new consciousness are prepared in the unconscious, how they get integrated into the conscious life, and what is essential for the accomplishment of the process. The tale begins with a poor woodcutter who, in order to escape from poverty, starts gathering twice as much firewood. However, the newly acquired amount disappears overnight, so the woodcutter gets perplexed and curious about where it goes and who is taking it. He seeks to find out the truth, which leads him to an unexpected journey to Heaven. There he learns the truth concerning his very tiny amount of fortune, and discovers another big fortune for an unborn person. By pleading with the ruler of Heaven, the woodcutter borrows that grand fortune, on the condition that he must return it to the owner when the time comes. After that, the woodcutter's life undergoes a series of changes, in which he finally becomes a wealthy farmer, but gradually is reminded more and more that the destined time is approaching. In the end, the fortune is completely transferred to the original owner, resulting in a dramatic twist and the creation of a new life circumstances. The overall plot can be understood as a reflection of the psychological process aiming at the evolution of consciousness through renewal. In this context, the woodcutter can be considered a psychic element that undergoes a continuous transformation in preparation for participating in the upcoming new consciousness. In other words, the changes brought about by this figure can be interpreted as a gradual and increasingly detailed foreshadowing of what the forthcoming new consciousness would be like. Interestingly, as the destined time approaches, the protagonist's anguish in conflict reaches its climax, despite his good performance in his role until then. This effectively portrays the difficulty of achieving a new dimension of consciousness, which requires moving past the last step. All the events in the story ultimately converge at this point. After all, the resolution occurs when the protagonist lets go of everything he has and follows the will of Heaven. This implies what is essential for the renewal of consciousness. Only by completely complying with the entire mind, the potential constituents of the new consciousness that should play important roles in a renewal and evolution of consciousness through experiencing, can participate in the ultimate outcome. As long as they remain trapped in any intermediate stage, the totality of the psyche would develop another detour aiming at the final destination, which means the beginning of another period of suffering carrying a purposeful meaning. The tale suggests that this truth will be applied everywhere that renewal of consciousness is directed, whether for an individual or a society.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

A Study on Hoslital Nurses' Preferred Duty Shift and Duty Hours (병원 간호사의 선호근무시간대에 관한 연구)

  • Lee, Gyeong-Sik;Jeong, Geum-Hui
    • The Korean Nurse
    • /
    • v.36 no.1
    • /
    • pp.77-96
    • /
    • 1997
  • The duty shifts of hospital nurses not only affect nurses' physical and mental health but also present various personnel management problems which often result in high turnover rates. In this context a study was carried out from October to November 1995 for a period of two months to find out the status of hospital nurses' duty shift patterns, and preferred duty hours and fixed duty shifts. The study population was 867 RNs working in five general hospitals located in Seoul and its vicinity. The questionnaire developed by the writer was used for data collection. The response rate was 85.9 percent or 745 returns. The SAS program was used for data analysis with the computation of frequencies, percentages and Chi square test. The findings of the study are as follows: 1. General characteristics of the study population: 56 percent of respondents was (25 years group and 76.5 percent were "single": the predominant proportion of respondents was junior nursing college graduates(92.2%) and have less than 5 years nursing experience in hospitals(65.5%). For their future working plan in nursing profession, nearly 50% responded as uncertain The reasons given for their career plan was predominantly 'personal growth and development' rather than financial reasons. 2. The interval for rotations of duty stations was found to be mostly irregular(56.4%) while others reported as weekly(16.1%), monthly(12.9%), and fixed terms(4.6%). 3. The main problems related to duty shifts particularly the evening and night duty nurses reported were "not enough time for the family, " "afraid of security problems after the work when returning home late at night." and "lack of leisure time". "problems in physical and physiological adjustment." "problems in family life." "lack of time for interactions with fellow nurses" etc. 4. The forty percent of respondents reported to have '1-2 times' of duty shift rotations while all others reported that '0 time'. '2-3 times'. 'more than 3 times' etc. which suggest the irregularity in duty shift rotations. 5. The majority(62.8%) of study population found to favor the rotating system of duty stations. The reasons for favoring the rotation system were: the opportunity for "learning new things and personal development." "better human relations are possible. "better understanding in various duty stations." "changes in monotonous routine job" etc. The proportion of those disfavor the rotating 'system was 34.7 percent. giving the reasons of"it impedes development of specialization." "poor job performances." "stress factors" etc. Furthermore. respondents made the following comments in relation to the rotation of duty stations: the nurses should be given the opportunity to participate in the. decision making process: personal interest and aptitudes should be considered: regular intervals for the rotations or it should be planned in advance. etc. 6. For the future career plan. the older. married group with longer nursing experiences appeared to think the nursing as their lifetime career more likely than the younger. single group with shorter nursing experiences ($x^2=61.19.{\;}p=.000;{\;}x^2=41.55.{\;}p=.000$). The reason given for their future career plan regardless of length of future service, was predominantly "personal growth and development" rather than financial reasons. For further analysis, the group those with the shorter career plan appeared to claim "financial reasons" for their future career more readily than the group who consider the nursing job as their lifetime career$(x^2$= 11.73, p=.003) did. This finding suggests the need for careful .considerations in personnel management of nursing administration particularly when dealing with the nurses' career development. The majority of respondents preferred the fixed day shift. However, further analysis of those preferred evening shift by age and civil status, "< 25 years group"(15.1%) and "single group"(13.2) were more likely to favor the fixed evening shift than > 25 years(6.4%) and married(4.8%)groups. This differences were statistically significant ($x^2=14.54, {\;}p=.000;{\;}x^2=8.75, {\;}p=.003$). 7. A great majority of respondents(86.9% or n=647) found to prefer the day shifts. When the four different types of duty shifts(Types A. B. C, D) were presented, 55.0 percent of total respondents preferred the A type or the existing one followed by D type(22.7%). B type(12.4%) and C type(8.2%). 8. When the condition of monetary incentives for the evening(20% of salary) and night shifts(40% of. salary) of the existing duty type was presented. again the day shift appeared to be the most preferred one although the rate was slightly lower(66.4% against 86.9%). In the case of evening shift, with the same incentive, the preference rates for evening and night shifts increased from 11.0 to 22.4 percent and from 0.5 to 3.0 percent respectively. When the age variable was controlled. < 25 yrs group showed higher rates(31.6%. 4.8%) than those of > 25 yrs group(15.5%. 1.3%) respectively preferring the evening and night shifts(p=.000). The civil status also seemed to operate on the preferences of the duty shifts as the single group showed lower rate(69.0%) for day duty against 83. 6% of the married group. and higher rates for evening and night duties(27.2%. 15.1%) respectively against those of the married group(3.8%. 1.8%) while a higher proportion of the married group(83. 6%) preferred the day duties than the single group(69.0%). These differences were found to be statistically all significant(p=.001). 9. The findings on preferences of three different types of fixed duty hours namely, B, C. and D(with additional monetary incentives) are as follows in order of preference: B type(12hrs a day, 3days a wk): day shift(64.1%), evening shift(26.1%). night shift(6.5%) C type(12hrs a day. 4days a wk) : evening shift(49.2%). day shift(32.8%), night shift(11.5%) D type(10hrs a day. 4days a wk): showed the similar trend as B type. The findings of higher preferences on the evening and night duties when the incentives are given. as shown above, suggest the need for the introductions of different patterns of duty hours and incentive measures in order to overcome the difficulties in rostering the nursing duties. However, the interpretation of the above data, particularly the C type, needs cautions as the total number of respondents is very small(n=61). It requires further in-depth study. In conclusion. it seemed to suggest that the patterns of nurses duty hours and shifts in the most hospitals in the country have neither been tried for different duty types nor been flexible. The stereotype rostering system of three shifts and insensitiveness for personal life aspect of nurses seemed to be prevailing. This study seems to support that irregular and frequent rotations of duty shifts may be contributing factors for most nurses' maladjustment problems in physical and mental health. personal and family life which eventually may result in high turnover rates. In order to overcome the increasing problems in personnel management of hospital nurses particularly in rostering of evening and night duty shifts, which may related to eventual high turnover rates, the findings of this study strongly suggest the need for an introduction of new rostering systems including fixed duties and appropriate incentive measures for evenings and nights which the most nurses want to avoid, In considering the nursing care of inpatients is the round-the clock business. the practice of the nursing duty shift system is inevitable. In this context, based on the findings of this study. the following are recommended: 1. The further in-depth studies on duty shifts and hours need to be undertaken for the development of appropriate and effective rostering systems for hospital nurses. 2. An introduction of appropriate incentive measures for evening and night duty shifts along with organizational considerations such as the trials for preferred duty time bands, duty hours, and fixed duty shifts should be considered if good quality of care for the patients be maintained for the round the clock. This may require an initiation of systematic research and development activities in the field of hospital nursing administration as a part of permanent system in the hospital. 3. Planned and regular intervals, orientation and training, and professional and personal growth should be considered for the rotation of different duty stations or units. 4. In considering the higher degree of preferences in the duty type of "10hours a day, 4days a week" shown in this study, it would be worthwhile to undertake the R&D type studies in large hospital settings.

  • PDF

A Study of Mac(脈)-Theory and Change of Mac(脈)-Diagnosis in Whang Di Nei Qing(黃帝內經) (황제내경(黃帝內經)의 맥(脈) 이론(理論)과 진맥법(診脈法)의 변화(變化)에 관(關)한 연구(硏究))

  • Ra, Kyoung-Chan;Park, Hyun Kook
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.2 no.1
    • /
    • pp.73-105
    • /
    • 1993
  • To say nothing of the orient and the west, the human beings discover the method of Jin Mac(診脈) by the way that observe disease. But oriental medicine devise special method of Jin Mac(診脈) in the study of Kyoung Mac(經脈). Although sip-ei Kyoung Mac Jin(十二經脈診), Sam Bu Gu Who Jin(三部九候診), In Young Mac Gu Jin(人迎脈口診), Chon Kwan Chuck Jin(寸關尺診) namely Yuk Bu Jung Wee Jin Mac (六部定位診脈) that is used today are devised, it has changed naturally by the changing treatment and the introduction of Yuin Yang(陰陽) and five element(五行). Many methods dg Jin Mac(診脈), it had not developped successing alternative, it had developped of declined by it's own way. 1. Results for the birth of Mac(脈) 1) Mac(脈), it means Kyoung Mac(經脈), at first entirelly Mac(脈), is seized a blood vessel that flows in the body. As presumed today, after finding many acupunture point, a general idea of Mac(脈) is not maked by the line that connect point and point, it connect between acupunture point and acupunture point. 2) Like blood flows in Hyul Mac(血脈), Gie(氣) flows in Kyoung Mac(經脈). The two things relate deeply each other. In a general idea or actrally Kyoung Rak(經洛), the two things sometimes accord, sometimes seperate, sometimes mix alternative. 3) Hyul Mac(血脈) and Kyoung Mac(經脈), we call it Mac(脈) entirely Kyoung Mac(經脈), is a way that manifest disease through Kyoung Mac(經脈) or a boundary that disease belongs to it method of Mac Jin(脈診) individual that disease of Kyoung Mac(經脈) is diagnosed by the jumping situation of Hyul Mac(血脈). 4) In method of Moxa, athough the pathology and the diagnostic of Mac(脈) are created by finding Mac(脈). Finding acupunture have opportunitty fot Mac Jin(脈診) and treatment. 2. Results of Kyoung Mac Mac Jin(經脈脈診) 1) In theory of kyoung Rak(經洛), disease are resumed for malfunction of Young Wee(榮衛) that flows in Kyung Rak(經洛). So to speak, in treatment of Kyoung Rak area, the purpose of diagnosis observe the situation of disease and cause. For fitting the purpose of diagnosis, the dead had esatablised four-diagnosis method mangMunMnnJeul(望聞問切), in four-diagnosis(四診法), the core is Mac Jin(脈診). 2) sip-ei Kyoung Mac Mac Jin(十二經脈診) had existed as Kyoung Mac Mac Jin(經脈脈診), it precedes Sam Bu Gu Who Jin(三部九候診). In Young Ki Gu Mac(人迎脈口診). 3) Although Bu Yang Mac(趺陽脈), So Um Mac(少陰脈) is a part of Sip-ei Kyoung Mac(十二經脈診), they developped especially because they located in the point of Won Hyul(原穴) and they are convenient for diagnose. 4) Sip-ei Kyoung Mac Mac Jin(十二經脈診), which belongs to Bu Yang Mac(趺陽脈) and So Urn Mac(少陰脈), is not important for the comming age medical books compared with Mac Kyoung(脈經). 3. Results gor Sam Bu Gu Who Jin(三部九候診) 1) Mac Jin(脈診) of Sam Bu Gu Who(三部九候), which is noted in the theory of Sam Bu Gu Who(三部九候診) of So Mun(素問), belongs to Kyoung Mac Mac Jin's(經脈脈診) geneology, Sip-ei Kyoung Mac Mac Jin(十二經脈診) is arranged, simplicated by the idealogy three talents(三才思想) in the heaven and the earth. 2) What Sam Bu Gu Jin(三部九候診) is regardded as very important in So Mun(素問), the editor of So Mun(素問) recognize the meaning that one discover disease early in this method of diagnosis. 3) After Young chu(靈樞), Nan Kyoung(難經) it is lacked the method of Sam Bu Gu Who Jin(三部九候診) in the books that treatment has changed. Sam Bu Gu Who Jin(三部九候診) based on actually clinic appropriate. 4. results for In Young Mac Gu Jin(人迎脈口診) 1) In Young Mac Gu Jin(人迎脈口診) is the method of comparative Mac Jin(脈診) according to the theory of Yin Yang(陰陽), it is presumed after Sam Bu Gu Who Jin(三部九候診), it had perished in parallel with the development of the theory of five elelment(五行). The development of the acupunture, the perishment of the treatment of negative(刺絡). 2) In Young Mac Gu Jin(人迎脈口診), Wang Suk Wha(王叔和) recreated that the left is In Young(人迎), the right is Kie Gu(氣口). In future generations by Jin Mu Taek(陳無擇) who is the writer of Sam In Bang(三因方). In Young Mac Gu Jin(人迎脈口診) is a measure for disease which classify it's inside and outside cause. 5. Results for Chon Gu Mac Jin(寸口脈診) 1) What we say Mac Jin(脈診) of Chon Gu(寸口) two means are used in commn. First case, we simply say the area of Chon Gu(寸口), second case, we say Chon Kwan Chuk Jin(寸口尺診) reducingly. Chon Gu(寸口) is the area which is the radial artery of wrist joint. What we attemp diagnose by only Chon Gu Mac(寸口脈), it is clearly shoued in the method of Nan Kyoung, five Nan(難經五難). 2) Because Jin Mac(診脈) is made in only Chon Gu(寸口), that is the area in which is concentated Kyoung Kee(經氣). That is the birth of Jin Kee(眞氣) and Jin Kee(眞氣) is related with disease. We can diagnose disease by taking Chon Gu(寸口). 3) Chuk Jin(尺診) in Nae Kyoung(難經) have two things. One is Il Chuk(一尺), the other is Chon Kwan Chu(寸關尺). 4) Chuk Chon Jin(尺寸診) is the method which diagnose the difference of point and the condition of Mac(脈) by dividing a part of Chuk(尺) in the area of Chon Gu(寸口). In Chon Gu Jin(寸口診), by introducing the theory of Yin Yang(陰陽), the method of Chon Gu Jin(寸口診) is developed by chon Gu Jin(寸口診). 5) What Chuk Kwan Chon Jin(寸關尺診) is that area of the Chon Gu(寸口) are divided fot three point, we can diagnose. By consulting Sam Bu Gu Who Jin(三部九候診), developping of the method of acupunture, utilzing the theory of five element(五行) it is devised by concentrating way of thinking of the method mac Jin(脈診) exiting. 6) Chon Kwan Chuk Jin MaC(寸關尺診脈) begin from Nae Kyoung(內徑) exiting. After Nan Kyoung(內徑), spread out widely from Mac Kyoung(脈診) of Wang Suk wha(王叔和), the future medicins followed it. Yang Hyun Jo(楊玄操) and established Chon Kwan Chuk Jin(寸關尺診) which is used widely today. This right and left Chon Kwan Chuk Jin(寸關尺診), we call it method of Yuk Bu Jung Wee Jin Mac(六部定位診脈). 7) We can think the base which presume the arrangement of the viscera for Chon Kwan Chuk(寸關尺) of the right and the left. 8) The origin, which seperate the right and the left of Mac(脈), is showed at the treory of Ji Jin Yo Dae(至眞要大論) in So Mun(素問) which Chon Chuk(寸尺) seperate the right and the left. But the method of diagnosis in Nan Kyoung(難經) have no seperation the fight and the left. Otherwise this. there is clearly writtened the seperation for the right origin of the method of Yuk Bu Jung Wee Jin Mac(六部定位診脈) seek for Cang Gong(倉公). 9) Yang Hyun Jo(楊玄操) notice that the Chuk(尺) is mentioned for Sam Cho(三焦) in the method of Mac Kyuong(脈經), Sim Po Kyung(心包經) which put together with Sam Cho(三焦) allot on this, he had established the method of Yuk Bu Jung Wee Jin Mac(六部定位診脈). 10) On the method of Paen Jak Yin Yang Mac(扁鵲陰陽脈) in Mac Kyoung(脈經), equal article exist with the theory of Pyung In Kee Sang(平人氣象論) in So Mun(素問). When Wang Suk Wha(王叔和) write Mac Kyung(脈經), we can presume that the book of Mac(脈) which Paen Jak(扁鵲) had experienced the origin have exited besides So Mun(素問), Young Chu(靈樞). If so he must be make Chon Kwan Chuk Jin(寸關尺診) very fairly standard. So Nae Kyoung(內經), which must be fllowed the method of Paen Jak Mac(扁鵲脈), do the method diagnosis of Chon Kwan Chuk(寸關尺), diagnise of disease and treat.

  • PDF

A Study on Startups' Dependence on Business Incubation Centers (창업보육서비스에 따른 입주기업의 창업보육센터 의존도에 관한 연구)

  • Park, JaeSung;Lee, Chul;Kim, JaeJon
    • Korean small business review
    • /
    • v.31 no.2
    • /
    • pp.103-120
    • /
    • 2009
  • As business incubation centers (BICs) have been operating for more than 10 years in Korea, many early stage startups tend to use the services provided by the incubating centers. BICs in Korea have accumulated the knowledge and experience in the past ten years and their services have been considerably improved. The business incubating service has three facets : (1) business infrastructure service, (2) direct service, and (3) indirect service. The mission of BICs is to provide the early stage entrepreneurs with the incubating service in a limited period time to help them grow strong enough to survive the fierce competition after graduating from the incubation. However, the incubating services sometimes fail to foster the independence of new startup companies, and raise the dependence of many companies on BICs. Thus, the dependence on BICs is a very important factor to understand the survival of the incubated startup companies after graduation from BICs. The purpose of this study is to identify the main factors that influence the firm's dependence on BICs and to characterize the relationships among the identified factors. The business incubating service is a core construct of this study. It includes various activities and resources, such as offering the physical facilities, legal service, and connecting them with outside organizations. These services are extensive and take various forms. They are provided by BICs directly or indirectly. Past studies have identified various incubating services and classify them in different ways. Based on the past studies, we classify the business incubating service into three categories as mentioned above : (1) business infrastructure support, (2) direct support, and (3) networking support. The business infrastructure support is to provide the essential resources to start the business, such as physical facilities. The direct support is to offer the business resources available in the BICs, such as human, technical, and administrational resources. Finally, the indirect service was to support the resource in the outside of business incubation center. Dependence is generally defined as the degree to which a client firm needs the resources provided by the service provider in order to achieve its goals. Dependence is generated when a firm recognizes the benefits of interacting with its counterpart. Hence, the more positive outcomes a firm derives from its relationship with the partner, the more dependent on the partner the firm must inevitably become. In business incubating, as a resident firm is incubated in longer period, we can predict that her dependence on BICs would be stronger. In order to foster the independence of the incubated firms, BICs have to be able to manipulate the provision of their services to control the firms' dependence on BICs. Based on the above discussion, the research model for relationships between dependence and its affecting factors was developed. We surveyed the companies residing in BICs to test our research model. The instrument of our study was modified, in part, on the basis of previous relevant studies. For the purposes of testing reliability and validity, preliminary testing was conducted with firms that were residing in BICs and incubated by the BICs in the region of Gwangju and Jeonnam. The questionnaire was modified in accordance with the pre-test feedback. We mailed to all of the firms that had been incubated by the BICs with the help of business incubating managers of each BIC. The survey was conducted over a three week period. Gifts (of approximately ₩10,000 value) were offered to all actively participating respondents. The incubating period was reported by the business incubating managers, and it was transformed using natural logarithms. A total of 180 firms participated in the survey. However, we excluded 4 cases due to a lack of consistency using reversed items in the answers of the companies, and 176 cases were used for the analysis. We acknowledge that 176 samples may not be sufficient to conduct regression analyses with 5 research variables in our study. Each variable was measured through multiple items. We conducted an exploratory factor analysis to assess their unidimensionality. In an effort to test the construct validity of the instruments, a principal component factor analysis was conducted with Varimax rotation. The items correspond well to each singular factor, demonstrating a high degree of convergent validity. As the factor loadings for a variable (or factor) are higher than the factor loadings for the other variables, the instrument's discriminant validity is shown to be clear. Each factor was extracted as expected, which explained 70.97, 66.321, and 52.97 percent, respectively, of the total variance each with eigen values greater than 1.000. The internal consistency reliability of the variables was evaluated by computing Cronbach's alphas. The Cronbach's alpha values of the variables, which ranged from 0.717 to 0.950, were all securely over 0.700, which is satisfactory. The reliability and validity of the research variables are all, therefore, considered acceptable. The effects of dependence were assessed using a regression analysis. The Pearson correlations were calculated for the variables, measured by interval or ratio scales. Potential multicollinearity among the antecedents was evaluated prior to the multiple regression analysis, as some of the variables were significantly correlated with others (e.g., direct service and indirect service). Although several variables show the evidence of significant correlations, their tolerance values range between 0.334 and 0.613, thereby demonstrating that multicollinearity is not a likely threat to the parameter estimates. Checking some basic assumptions for the regression analyses, we decided to conduct multiple regression analyses and moderated regression analyses to test the given hypotheses. The results of the regression analyses indicate that the regression model is significant at p < 0.001 (F = 44.260), and that the predictors of the research model explain 42.6 percent of the total variance. Hypotheses 1, 2, and 3 address the relationships between the dependence of the incubated firms and the business incubating services. Business infrastructure service, direct service, and indirect service are all significantly related with dependence (β = 0.300, p < 0.001; β = 0.230, p < 0.001; β = 0.226, p < 0.001), thus supporting Hypotheses 1, 2, and 3. When the incubating period is the moderator and dependence is the dependent variable, the addition of the interaction terms with the antecedents to the regression equation yielded a significant increase in R2 (F change = 2.789, p < 0.05). In particular, direct service and indirect service exert different effects on dependence. Hence, the results support Hypotheses 5 and 6. This study provides several strategies and specific calls to action for BICs, based on our empirical findings. Business infrastructure service has more effect on the firm's dependence than the other two services. The introduction of an additional high charge rate for a graduated but allowed to stay in the BIC is a basic and legitimate condition for the BIC to control the firm's dependence. We detected the differential effects of direct and indirect services on the firm's dependence. The firms with long incubating period are more sensitive to indirect service positively, and more sensitive to direct service negatively, when assessing their levels of dependence. This implies that BICs must develop a strategy on the basis of a firm's incubating period. Last but not least, it would be valuable to discover other important variables that influence the firm's dependence in the future studies. Moreover, future studies to explain the independence of startup companies in BICs would also be valuable.