• Title/Summary/Keyword: Hp (0.07)

Search Result 24, Processing Time 0.026 seconds

Dose metrology: TLD/OSL dose accuracy and energy response performance

  • Omaima Essaad Belhaj;Hamid Boukhal;El Mahjoub Chakir;Meryeme Bellahsaouia;Siham Belhaj;Younes Sadeq;Mohammed Tazi;Tahar El Khoukhi;Maryam Hadouachi;Khaoula Laazouzi
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.717-724
    • /
    • 2023
  • An essential step in evaluating and comparing the performance of two passive radiation dosimeter types, thermosluminescent (TLD) and optically stimulated luminescence (OSL), used by workers in environments with ionizing radiation for individual radiological monitoring and control of external exposure at various times (cumulative dose for 1 month), is to compare the measured dose accuracy, energy response, and coefficient of variation. In fact this performance study consists in determining the accuracy of both R(10) and R(0.07) which are considered as the ratios of the measured dose (Hp(10) or Hp(0.07)) to the delivered dose (Hp(10) or Hp(0.07)) for each photon energy. The validity of the results of this test is based on the acceptance limits of the ICRP and the international standard IEC-62387. The relative energy response used is normalized to the 137Cs 662 keV energy to find which energy response is closest to the ideal case, and the coefficient of variation that allows to determine the statistical fluctuation of the Hp(10) and Hp(0.07) doses. The results of the accuracy test for the OSL and TLD dosimeters are acceptable because they fall within the ICRP limits. For the energy response, the OSL performs better than the TLD for Hp(10) and Hp(0.07), and for the coefficient of variation, the OSL satisfies the requirements of ISO 62387 for both Hp(10) and Hp(0.07), while the TLD satisfies these requirements only for the measurement of Hp (0.07).

A Study on the Analysis of Radiation Dose for Thermoplastic Material and 3D Print Filament Materials (열가소성 플라스틱 재질과 3D 프린트 필라멘트 재질에 대한 방사선량 분석에 관한 연구)

  • Lee, Dong-Yeon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.181-189
    • /
    • 2021
  • This study is a prior research to manufacture a thermoplastic mask, which is a fixture used in radiation therapy, by 3D printing. It proceeded to analyze the filament material that can replace the thermoplastic. Among the commercially available filament materials, a material having similar characteristics to that of a thermoplastic mask was selected and the radiation dose was compared and analyzed. The experiment used Monte Carlo simulation. The shape in which the mask fixed the head was simulated for the ICRU sphere. The photon fluence was calculated at the skin Hp (0.07), the lens Hp (3), and the whole body Hp (10) by applying a thermoplastic plastic material and a filament material. As a result, when looking at the relative dose based on the thermoplastic plastic material, the difference was approximated within 4%. The material showing the most similar dose was PA-nylon. In selecting an appropriate filament material, it should be selected by comprehensively considering various conditions such as economical efficiency and radiation effects. It is thought that the results of this study can be used as basic data.

Performance Simulation of Turboprop Engine using SIMULINK$\circledR$ (SIMULINK$\circledR$를 이용한 터보프롭 엔진의 성능모사)

  • 공창덕;노흥석
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.5 no.2
    • /
    • pp.44-50
    • /
    • 2001
  • After modeling an aircraft turboprop engine using SIMULINK$\circledR$, performance simulation of PT6A-62 engine, which is main power plant of KT-1, was performed. For validation, performance parameters of the SIMULIINK model were compared with the simulated results by GASTURB program. It was confirm that the results by the SIMULINK model were well agreed with those by GASTURB within 1.07%, It was assumed that installation losses were bleed-air exteraction with a range from 0% to 5%, and power for accessories with a range from 0 to 20hp. In this investigation, it was found that the shafthorsepower was decreased by maxium 0.68%, but specific fuel consumption ratio was not effected nearly by these losses.

  • PDF

Post-operative analgesia of 2% lignocaine with or without magnesium sulfate for inferior alveolar nerve block in symptomatic mandibular molars - a randomized double blind controlled clinical trial

  • Chandrasekaran, Charanya;Vijay, Amirtharaj L;Sekar, Mahalaxmi;Mary, Nancy S
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.20 no.3
    • /
    • pp.147-154
    • /
    • 2020
  • Background: Single inferior alveolar nerve block is ineffective in achieving adequate pulpal anesthesia in 30-80% of patients due to anatomical variations, local tissue pH, central sensitization, and several factors. Various supplementary techniques and combination of adjuvants with lignocaine are used to overcome these failures. Magnesium sulfate (MgSO4), one such adjuvant, acts at the N-methyl-D-aspartate glutamate receptor resulting in effective anesthesia. The aim of this prospective, randomized, double-blind, clinical controlled trial was to evaluate the onset, anesthetic efficacy, duration and post-operative analgesia of 2% lignocaine with and without the addition of MgSO4 in patients with symptomatic irreversible pulpitis and apical periodontitis. Methods: Fourty-two patients were randomly divided into three groups: 2% lignocaine (group 1) and 2% lignocaine with MgSO4 (75 mg) and (150 mg) in groups 2 and 3, respectively. Pre-operative vitals and Heft Parker-Visual Analogue Scale (HP-VAS) pain scores were recorded. The onset of anesthesia, anesthetic efficacy, and duration of anesthesia were evaluated post administration of the local anesthetic solution. The post-operative analgesia was examined at intervals of 2, 6, 12, 24, and 48 h. Results: Administration of 150 mg MgSO4 hastens the onset of anesthesia (1.29 min) and produces better anesthetic efficacy (3.29 HP-VAS) compared to group 2 (2.07 min and 9.14 HP-VAS) and group 1 (3.29 min and 35.79 HP-VAS), respectively. The duration of anesthesia was significantly higher in group 3 (247.07 min) compared to that of groups 2 and 1 (190 min and 110.21 min) with P < 0.05. Conclusion: Combining 75 mg or 150 mg of MgSO4 with lignocaine is more effective than 2% lignocaine and 75 mg of MgSO4 is adequate for endodontic procedures.

SIMULINK^{$\circledR}$ Modeling of Turboprop Engine for the Performance Analysis (성능해석을 위한 터보프롭 엔진의 SIMULINK^{$\circledR}$ Modeling)

  • 노홍석;기자영;공창덕
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.76-79
    • /
    • 2001
  • SIMULINK^{$\circledR}$를 이용하여 항공기용 터보프롭 엔진을 모델링한 후 현재 KT-1의 추진기관인 PT6A-62 분리축 터보프롭엔진의 성능을 해석하였다. SIMULINK^{$\circledR}$ 모델의 검증을 위하여 상용해석프로그램인 GASTURB 와 비교한 결과 최대오차율 1.07% 이내로 확인되었다. 지상정지 조건에서 블리드 공기유량을 0에서 5%, 보기류 구동에 따른 출력손실을 0에서 20 hp로 가정하고 해석한 결과 축마력은 최대 0.68%감소하며 비연료소모율은 거의 영향을 받지 않음을 알 수 있었다.

  • PDF

Analgesic Effects of DA-5018, a New Capsaicin Derivative, after Subcutaneous Injection and Topical Application (새로운 캅사이신유도체 DA-5018의 피하주사 및 국소도포시 진통효과)

  • 김희기;배은주;신명수;손문호;김순희;김원배;양중익;공재양
    • Biomolecules & Therapeutics
    • /
    • v.5 no.2
    • /
    • pp.117-124
    • /
    • 1997
  • The analgesic effects of DA-5018, a new caosaucin derivative, were evaluated in various experimental pain models. Drugs were administered subcutaneously or topically. When drugs were administered subcutaneously, 1) the $ED_{50}$ of DA-5018, morphine . HCI, capsaicin and acetaminophen were 0.091-2.0, 0.3-4.3, 1.4-26.5 and 45.4-643 mg/kg, respectively in various pain or inflammatory models including acetic acid writhing, formalin, tail flick, Randall-Selitto, hot plate and crouton oil-induced ear edema test, 2) the AD2 values (the dose for doubling of pain threshold of vehicle control) of DA-5018, capsaicin and ketoprpgin were 1.07 $\pm$ 0. 18, 23.47$\pm$4.46 and 2.97$\pm$0.43 mg/kg in Freund's complete adjuvant (FCA)-induced arthritic pain model. And by topical application, 1) neither DA-5018 0.3% cream nor Zostrix-HP (capsaicin 0.075%) were effective in formalin test, 2) although DA-5018 0.3% cream significantly inhibited the croton oil-induced ear edema being better than Zostrix-HP and Kenofen (ketoprofen 3%). 3) In FCA model, DA-5018 0.3% cream reversed the decreased pain threshold of arthritic rat from 136.4 g (day 0) to 289.0 g (day 5) and 250.1 g (day 10), which was similar to Zostrix-HP. These results suggest that DA-5018 administered subcutaneously has a potent and broad analgesic spectrum than nonsteroidal antiinflammatory drugs against acute and chronic pain, and by topical application it exerts comparable analgesic and antiinglammaatory effects to capsaicin cream.

  • PDF

Domestic Intercomparison Study for the Performance of Personnel Dosimeters (개인선량계 성능의 국내 상호비교)

  • Kim, Jang-Lyul;Chang, Si-Young;Kim, Bong-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.3
    • /
    • pp.147-153
    • /
    • 1996
  • The Korea Atomic Energy Research Institute(KAERI) conducted a intercomparison study for personnel dosimetry services in Korea to enhance the accuracy and precision of the dosimetry system. Nine types of dosimeters(6 TLD, 3 film badge) from 7 institutions took part in this intercomparison study. Each participant submitted 30 dosimeters including transit control for irradiations. Both TLDs and film badges were irradiated with Cs-137 gamma, Sr/Y-90 beta and 4 X-ray beams in ISO wide series. Four dosimeters were irradiated on phantom with same dose equivalent for each field category. The delivered dose equivalent was in the range of $0.1{\sim}10mSv$. The participants assessed the results of their dosimeter readings in terms of the ICRU operational quantities for personal monitoring, Hp(10) and Hp(0.07). Most participants except 1 dosimeter estimated the delivered dose equivalent with biases less than ${\pm}25%$ for Cs-137 and Sr/Y-90. But for X-rays, the biases exceeded ${\pm}35%$ in some cases bacause the dose evaluation algorithm was based on the ANSI N13.11 X-ray fields which are different from those given by ISO.

  • PDF

Analysis of Power Requirement for 105 HP Agricultural Tractor during Rotary Tillage Operation (로타리 작업 시 105마력급 농업용 트랙터의 소요동력 분석)

  • Kim, Wan-Soo;Choi, Chang-Hyun;Park, Seong-Un;Kim, Yong-Joo
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.8-8
    • /
    • 2017
  • 본 연구는 로타리 작업에 따른 105마력급 농업용 트랙터의 소요동력을 분석하기 위하여 수행되었다. 소요동력 측정 시스템은 차축 토크미터, PTO 토크미터, 주/보조 유압센서, 데이터 수집장치를 이용하여 구성하였다. 시험에 사용된 트랙터는 동양물산 105 HP급 트랙터 (S07, TYM, Korea)이며, 작업기는 로타베이터 (SW 230GL, Sungwoo Industrial Co. Ltd, Korea)를 사용하였다. 포장시험은 전라북도 부안군에 죽림길에 위치한 $4,000m^2$ ($100m{\times}40m$) 크기의 경작지 2곳에서 수행하였다. 포장시험 시 작업 단수는 주행단수 L3단 (2.38 km/h)에서 PTO 단수 1단 (540 rpm)과 2단 (750 rpm)으로 설정하였고, 로타리 작업 시 경심은 13 cm 조건에서 실시하였다. 트랙터 작업은 동양물산의 성능시험 업무를 맡고 있는 숙련된 작업자가 숙달된 방법으로 수행하였다. 포장시험지의 토양환경은 임의의 15곳에서 채취한 시료를 이용하여 토성, 함수율, 원추 관입지수에 대하여 미국 농무부 (USDA)법을 기준으로 분석하였다. 토양환경 분석 결과 토성은 Sandy loam (사양토), 평균 함수율은 35.15%, 평균 원추관입지수는 1,562 kPa로 나타났다. PTO 1단 작업 시 트랙터의 평균 소요동력은 차축, PTO, 주 유압, 보조 유압에 대하여 각각 1.8, 54.0, 1.3, 그리고 1.1 hp로 나타났다. PTO 2단 작업 시 트랙터의 평균 소요동력은 차축, PTO, 주 유압, 보조 유압에 대하여 각각 1.2, 79.4, 1.2, 그리고 1.0 hp로 나타났다. PTO 1단 작업 시 소요동력의 합은 58.2 hp로, 정격 마력 (105 hp) 대비 55.43 % 사용한 것으로 나타났으며, PTO 2단 작업 시 소요동력의 합은 82.8 hp로, 정격 마력 대비 78.85% 사용한 것으로 나타났다. PTO 1단 대비 2단에서는 PTO를 제외한 차축, 주 유압, 보조 유압의 소요동력이 감소하였으나, PTO에서 약 1.47배로 크게 증가하여 전체적으로 소요동력이 증가한 것으로 나타났다. 향후 다양한 작업기 및 작업 단수에 따른 소요동력을 분석하여 농업용 트랙터의 모든 부하 조건에 대한 데이터베이스 구축에 관한 연구를 수행할 예정이다.

  • PDF

Chemical Properties of the Insecticidal Compound Produced by an Actinomycetes, SS-4993 (방선균 SS-4993이 분비하는 살충물질의 화학적 성상 및 작용기작)

  • 이은정;강경돈;황교열;김두호;이상몽;김신덕;성수일
    • Journal of Sericultural and Entomological Science
    • /
    • v.41 no.3
    • /
    • pp.180-184
    • /
    • 1999
  • The insecticidal compound priduced by Streptomyces SS-4993 strain was indicated to be a relatively stable small compound by pancreatin treatment. The active compound was adsorbed on HP20 and eluted with 70% acetone. Then, the eluate was extracted with ethyl acetate. The content of the extract was determined by thin layer chromatography (Silica gel 60 F254, hexane-ethyl ether-acetic acid,80 : 20 :1). Three active bands (Rf 0.08, 0.07, 0.88) were identified by dermal application using Bombyx mori larvae. Electrophoretic analysis revealed that the injection of strain SS-4993 culture broth into B. mori larvae induce the reduction of the hemolymph proteins level. Especially, the level of apolipophorin-I was decreased drastically.

  • PDF

Evaluation of surface roughness of heat-polymerized denture base resin according to the polishing step (연마 과정에 따른 열중합 의치상 레진의 표면 거칠기 평가)

  • Hwang, Seong-Sig;Im, Yong-Woon;Kim, Si-Chul;Han, Min-Soo
    • Journal of Technologic Dentistry
    • /
    • v.37 no.4
    • /
    • pp.205-212
    • /
    • 2015
  • Purpose: The objective of this study was to compare the surface roughness according to polishing process in conventional laboratory techniques used for polishing three different acrylic denture base resins. Materials and methods: Specimen preparation and surface polishing procedures were conducted to manufacturer's recommendation with three heat-polymerized denture base resins. Surface roughness and gloss were measured by a contact type tester and a LED gloss checker using thickness 2 mm and diameter 10 mm. There were five specimens for each acrylic resin material and polishing procedures. Mean average surface roughness (Ra) values of each specimen group were analyzed using a one-way ANOVA analysis of variance and Scheffe's post hoc test. Surfaces after surface roughness and gloss testing according to each polishing process were evaluated under a stereoscopic microscope. Results: The highest mean average surface roughness was measured($Ra=2.43{\pm}0.47$) for surfaces finished with a denture tungsten carbide bur in Triplex. The lowest surface roughness values ($Ra=0.11{\pm}0.07$) were determined in Vertex polished with a lathe. In addition, all materials revealed that surface roughness determined highly in HP1 and HP2 than other procedures. All correlation between surface roughness and gloss showed highly with three heat-polymerized resins. Specially, topmost correlation revealed than other material in Triplex. Significant differences in mean average surface roughness were found between polishing process used high speed lathe and low speed hand-piece. Conclusion: Laboratory polishing used to high speed was found to produce the smoothest surface of heat-polymerized denture base acrylic resin. Therefore, we recommended that high polishing process need to get smooth surface.