• Title/Summary/Keyword: Hounsfield Unit

Search Result 118, Processing Time 0.022 seconds

Problems of Implant Procedure and Medical Disputes (임플란트 시술의 문제점과 의료분쟁)

  • Lee, Tae-Hui;Song, Young-Ji
    • The Korean Society of Law and Medicine
    • /
    • v.17 no.1
    • /
    • pp.281-297
    • /
    • 2016
  • In order to make a treatment plan and outcome prediction, it is important to evaluate accurately and objectively osseous tissues of the implant area. The evaluation of osseous tissues is the most objective method for the decision of production time of upper structure of alveolar bone. However, the evaluation of osseous tissues contains contradiction because it is made by subjective opinions of dental surgeons. Many dentists also point out the problem of subjective evaluation of osseous tissues. Therefore, it is necessary to create accurate and objective standards. Previously, the evaluation of bone density depends on dentist's subjective sensation during drilling procedure of implant. However, the HU(Hounsfield unit) figure of CT(computed tomography) scan allows of objective and precise categorization of bone density now. Misch and Kircos divided the bone density levels from D1 to D5 with subjective separation of bone density. Their method also depended on not objective and quantification data but subjective separation by sensation. Thus, we need the evaluation of implant area through comparative analysis of more objective and quantification data. Implant treatment comprises the highest frequency of medical disputes of dental clinic. If we bring objective checkup and reasonable treatment method in the implant treatment, we can deduce more reasonable results, and the failure late of implant treatment also can decrease. The ultimate objective of this study is the minimization of dental disputes between dental patients and dentists by creating new legal standards on the basis of objective and quantification data.

  • PDF

A Study on the Fabrication of bone Model X-ray Phantom Using CT Data and 3D Printing Technology (CT 데이터와 3D 프린팅 기술을 이용한 뼈 모형 X선 팬텀 제작에 관한 연구)

  • Yun, Myeong Seong;Han, Dong-Kyoon;Kim, Yeon-Min;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.879-886
    • /
    • 2018
  • A 3-dimensional (D) printer is a device capable of outputting a three-dimensional solid object based on data modeled in a computer. These features are utilized in the bone model X - ray phantom production etc using CT data by fusing with the radiation science field. A bone model phantom was made using data obtained by CT scan of an existing Pelvis phantom, using PLA, Wood, XT-CF20, Glow fill, Steel filaments which are materials of Fused Filament Fabrication (FFF) 3D printer.Measure Hounsfield Unit (HU) with images obtained by CT scan of the existing Pelvis phantom and five material phantoms made with 3D printer under the same conditions,SI and SNR were measured using a diagnostic X-ray generator, and each phantom was compared and analyzed.As a result, the X - ray phantom in the X - ray examination condition of the limb was found to be most suitable for the glow fill filament.The characteristics of the filament can be known to the base of this research and the practicality of X - ray phantom fabrication was confirmed.

The Effect of Hounsfield Unit Value with Conventional Computed Tomography and Intraoperative Distraction on Postoperative Intervertebral Height Reduction in Patients Following Stand-Alone Anterior Cervical Discectomy and Fusion

  • Lee, Jun Seok;Son, Dong Wuk;Lee, Su Hun;Ki, Sung Soon;Lee, Sang Weon;Song, Geun Sung;Woo, Joon Bum;Kim, Young Ha
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.1
    • /
    • pp.96-106
    • /
    • 2022
  • Objective : The most common complication of anterior cervical discectomy and fusion (ACDF) is cage subsidence and maintenance of disc height affects postoperative clinical outcomes. We considered cage subsidence as an inappropriate indicator for evaluating preservation of disc height. Thus, this study aimed to consider patients with complications such as reduced total disc height compared to that before surgery and evaluate the relevance of several factors before ACDF. Methods : We retrospectively reviewed the medical records of 40 patients who underwent stand-alone single-level ACDF using a polyetheretherketone (PEEK) cage at our institution between January 2012 and December 2018. Our study population comprised 19 male and 21 female patients aged 24-70 years. The minimum follow-up period was 1 year. Twenty-seven patients had preoperative bone mineral density (BMD) data on dual-energy X-ray absorptiometry. Clinical parameters included sex, age, body mass index, smoking history, and prior medical history. Radiologic parameters included the C2-7 cobb angle, segmental angle, sagittal vertical axis, disc height, and total intervertebral height (TIH) at the preoperative and postoperative periods. Cage decrement was defined as the reduction in TIH at the 6-month follow-up compared to preoperative TIH. To evaluate the bone quality, Hounsfield unit (HU) value was calculated in the axial and sagittal images of conventional computed tomography. Results : Lumbar BMD values and cervical HU values were significantly correlated (r=0.733, p<0.001). We divided the patients into two groups based on cage decrement, and 47.5% of the total patients were regarded as cage decrement. There were statistically significant differences in the parameters of measuring the HU value of the vertebra and intraoperative distraction between the two groups. Using these identified factors, we performed a receiver operating characteristic (ROC) curve analysis. Based on the ROC curve, the cut-off point was 530 at the HU value of the upper cortical and cancellous vertebrae (p=0.014; area under the curve [AUC], 0.727; sensitivity, 94.7%; specificity, 42.9%) and 22.41 at intraoperative distraction (p=0.017; AUC, 0.722; sensitivity, 85.7%; specificity, 57.9%). Using this value, we converted these parameters into a bifurcated variable and assessed the multinomial regression analysis to evaluate the risk factors for cage decrement in ACDF. Intraoperative distraction and HU value of the upper vertebral body were independent factors of postoperative subsidence. Conclusion : Insufficient intraoperative distraction and low HU value showed a strong relationship with postoperative intervertebral height reduction following single stand-alone PEEK cage ACDF.

Stopping Power Ratio Estimation Method Based on Dual-energy Computed Tomography Denoising Images for Proton Radiotherapy Planning (양성자치료계획을 위한 이중에너지 전산화단층촬영 잡음 제거 영상 기반 저지능비 추정 방법)

  • Byungdu Jo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.207-213
    • /
    • 2023
  • Computed tomography (CT) images are used as the basis for proton Bragg peak position estimation and treatment plan simulation. During the Hounsfield Unit (HU) based proton stopping power ratio (SPR) estimation, small differences in the patient's density and elemental composition lead to uncertainty in the Bragg peak positions along the path of the proton beam. In this study, we investigated the potential of dual-energy computed tomography image-based proton SPRs prediction accuracy to reduce the uncertainty of Bragg peak position prediction. Single- and dual-energy images of an electron density phantom (CIRS Model 062M electron density phantom, CIRS Inc., Norfolk, VA, USA) were acquired using a computed tomography system (Somatom Definition AS, Siemens Health Care, Forchheim, Germany) to estimate the SPRs of the proton beam. To validate the method, it was compared to the SPRs estimated from standard data provided by the National Institute of Standards and Technology (NIST). The results show that the dual-energy image-based method has the potential to improve accuracy in predicting the SPRs of proton beams, and it is expected that further improvements in predicting the position of the proton's Bragg peak will be possible if a wider variety of substitutes with different densities and elemental compositions of the human body are used to predict the SPRs.

Multidetector Computed Tomography in Patients with Femoral Neck Fracture for Assessing Osteoporosis: Comparison with Dual Energy X-Ray Absorptiometry (대퇴골 경부 골절 환자에서 골다공증 평가를 위한 다중검출 CT의 이용: 이중에너지 X-선 흡수계측법과의 비교)

  • Hyo Jeong Lee;Ji Young Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.173-181
    • /
    • 2021
  • Purpose To evaluate the ability of the Hounsfield unit (HU) measurement of the femoral neck during multidetector computed tomography (MDCT) for assessing osteoporosis compared with dual-energy X-ray absorptiometry (DXA). Materials and Methods Forty-two patients with femoral neck fractures who underwent MDCT and DXA from July to December 2016 were included in this study. HU measurements were made of the cancellous portions of the normal contralateral femoral neck on MDCT. Bone mineral density (BMD) and T-scores were obtained at the femur DXA. Correlations of HU values with BMD and T-scores were analyzed using Spearman's correlation test. Results The mean BMD and T-score of the femoral neck were 0.650 g/cm2 and -2.4, respectively. The mean HU values for the normal, osteopenia, and osteoporosis groups were 131.9, 98.9, and 41.3, respectively. HU values at the femoral neck were positively correlated with BMD (r2 = 0.670; p < 0.001) and T-scores (r2 = 0.676; p < 0.001). Conclusion The HU values of the femoral neck on MDCT are significantly correlated with BMD and T-scores of femur DXA. The HU values may serve as a diagnostic tool for the screening of regional bone quality when MDCT is performed for other reasons.

Assessment of the increased calcification of the jaw bone with CT-Scan after dental implant placement

  • Yunus, Barunawaty
    • Imaging Science in Dentistry
    • /
    • v.41 no.2
    • /
    • pp.59-62
    • /
    • 2011
  • Purpose : This study was performed to evaluate the changes of jaw bone density around the dental implant after placement using computed tomography scan (CT-Scan). Materials and Methods : This retrospective study consisted of 30 patients who had lost 1 posterior tooth in maxilla or mandible and installed dental implant. The patients took CT-Scan before and after implant placement. Hounsfield Unit (HU) was measured around the implants and evaluated the difference of HU before and after implant installation. Results : The mean HU of jaw bone was 542.436 HU and 764.9 HU before and after implant placement, respectively (p<0.05). The means HUs for male were 632.3 HU and 932.2 HU and those for female 478.2 HU and 645.5 HU before and after implant placement, respectively (p<0.05). Also, the jaw bone with lower density needed longer period for implant procedure and the increased change of HU of jaw bone was less in the cases which needed longer period for osseointegration. Conclusion : CT-Scan could be used to assess the change of bone density around dental implants. Bone density around dental implant was increased after placement. The increased rate of bone density could be determined by the quality of jaw bone before implant placement.

Fluid Accumulation in Canine Tympanic Bulla: Radiography, CT and MRI Examinations

  • Lee, Young-Won;Kang, Sang-Kyu;Choi, Ho-Jung
    • Journal of Veterinary Clinics
    • /
    • v.25 no.3
    • /
    • pp.176-181
    • /
    • 2008
  • Fluid accumulation within the tympanic bulla is an important diagnostic indicator of canine otitis media although its identification can be a challenge using currently available imaging techniques. The purpose of this study was to compare radiography, computed tomography (CT) and magnetic resonance imaging (MRI) in the identification of fluid accumulation within canine tympanic bulla. Unilateral tympanic bulla in 10 beagles were experimentally filled with blood or saline. Quantitative analysis of CT images were obtained by using Hounsfield unit (HU). MR signal intensity was obtained by using region of interesting (ROI) and compared with those of gray matter. On the CT image, the presence of blood or saline produced a fluid opacity occupying the tympanic bulla. On the MR image, the appearance of blood in the tympanic bulla was isointense in T1-weighted images and hyperintense in T2-weighted images. However, the appearance of saline in the tympanic bulla was hypointense in T1-weighted images and hyperintense in T2-weighted images. This study suggest that CT and MR imaging are useful methods for detection and differentiation of fluid in canine tympanic bulla.

HU Threshold Value for IV Catheter Fragment in Peripheral Vein of Volume Rendering 3D MDCT Imaging (정맥 내의 IV 카테터 조각을 3D MDCT 볼륨렌더링 영상으로 구현하기 위한 HU 임계치)

  • Jang, Keun-Jo;Kweon, Dae-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.4
    • /
    • pp.206-212
    • /
    • 2007
  • To evaluate the HU value of the IV catheter fragment of CT on the accuracy and size in the peripheral vein. Pilot study of profile and table functions on PC by software was calculated of HU value of IV catheter fragment. This study demonstrates the utility of volume rendering technique to localize a small, subtle IV catheter, which can easily be reformatted of MDCT reformations. IV catheter fragment optimal image described as threshold range. Volume rendering of HU using a MDCT is an excellent method for evaluation the IV catheter fragment in three dimension.

The bone density of mandible as the aging process in Koreans (한국인 연령에 따른 하악 치조골 골밀도)

  • Lee, Chul-Won;Kim, Chul-Hwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.6
    • /
    • pp.496-504
    • /
    • 2011
  • Introduction: This study compared the alveolar bone density of the mandible according to gender, age and position using Cone-beam computed tomography (CT). Materials and Methods: The maxillofacial CT scan data was obtained from 60 Korean patients. In addition, the alveloar bone density of 5 males and 5 females with normal occlusion aged from 10 to 70 years was measured at the buccal cortical bone, cancellous bone and lingual cortical bone, as well as at the position of the incisors, canines, premolars and molars. Results: The age-specific mean bone density was highest in patients in their third decade. The buccal cortical bone of the molars showed the highest bone density. Males in their fifties and sixties had a higher bone density in the cancellous bone in the region of the premolars and the buccal cortical bone of the molars, respectively, than females but there was no significant difference between males and females in the other parts. The cancellous bone density was highest in those in their twenties and thirties, and tended to decline up to their seventh decade. Conclusion: These results revealed a significantly different bone density according to gender, age and position in the Korean population. In addition, it is possible to predict the bone density based on these results.

CT characteristics of normal canine pulmonary arteries and evaluation of optimal contrast delivery methods in CT pulmonary angiography

  • Jung, Joohyun;Chang, Jinhwa;Yoon, Junghee;Choi, Mincheol
    • Korean Journal of Veterinary Research
    • /
    • v.47 no.2
    • /
    • pp.247-254
    • /
    • 2007
  • This study was performed to identify the normal anatomic orientation of pulmonary arteries and to obtain the normal baseline parameters and the optimal contrast material delivery methods of computed tomographic pulmonary angiography (CTPA) on normal beagle dogs. Based on the contrast injection flow rate, the contrast volume, and the administration methods, the experimental groups were divided into 4 groups such as group 1 : 2 ml/s, 3 ml/kg, and monophasic administration; group 2 : 5 ml/s, 3 ml/kg, and monophasic administration; group 3 : 5 ml/s, 4 ml/kg, and monophasic administration; group 4 : 5 ml/s and 2 ml/kg in first phase, 0.3 ml/s and 2 ml/kg in second phase, as biphasic administration. Normal anatomic orientation of pulmonary arteries in CTPA was evaluated through reformatted and 3D images after retro-reconstruction. Normal parameters for great arteries and peripheral pulmonary arteries were obtained on the factor of basement hounsfield unit (HU) values, contrast enhanced HU values, delay time, and peak time. And the optimal contrast delivery methods were evaluated on the factor of contrast enhanced HU values, image quality, and artifact. The monophasic administration with 5 ml/s contrast injection flow rate and 3 ml/kg contrast volume was optimal in canine CTPA.