• 제목/요약/키워드: Hot-wire

검색결과 544건 처리시간 0.025초

풍동장치를 이용한 열선풍소계의 보정 및 실태 평가 (Calibration and Performance Test of Hot-wire Anemometers by Using a Calibration Wind Tunnel)

  • 하현철;김태형;김은아;김종철;오정룡;정호근
    • 한국산업보건학회지
    • /
    • 제9권2호
    • /
    • pp.110-122
    • /
    • 1999
  • Hot-wire anemometers are most commonly used in measuring hood capture velocities due to their accuracy and convenience. But it was questionable that the anemometers being used in the field are accurate enough for the purpose of measurements. To answer this ques tion, a calibration wind tunnel was newly devised and tested. Subsequently, 53 hot-wire anemometers being currently used in the field were tested to evaluate the accuracy of anemometers. The average error was 16.93% while the average errors in the low (0.5~5m/s) and high (5~20m/s) velocity range were 17.40% and 16.45%, respectively. Most of anemometers underestimated the true velocities. It might be due to the contamination of hot-wire, resulting in the slow heat transfer between the sensor and air flow. Astonishingly, 16 of 53 anemometers were out of order due to the malfunctioning of zero adjustment control, power supply, display panel and sensor. It is desirable to calibrate periodically and clean the sensor after using in the dirty environment.

  • PDF

안경용 순티타늄 wire 제조 공정개발 (Development of Manufacturing Process of Pure Titanium Wire to make Eyewear Frame)

  • 최계훈;김상연
    • 한국산학기술학회논문지
    • /
    • 제12권3호
    • /
    • pp.1105-1110
    • /
    • 2011
  • 직경 400mm 순티타늄 잉고트(Gr2)를 제작하고 성분 분석한 결과 산소함량이 0.073wt%이고 철함량이 0.03wt%로서 ASTM Gr.2 규격을 만족하였다. 이들을 가공하여 42mm 선재를 만들고 18단 열간 압연하여 9mm 선재를 만들었다. 10단 열간 가공한 15.8mm 선재를 표면에서 부터 중심부로 가면서 경도 분석한 결과 Hv150~200로서 거의 일정한 값을 나타내고 있었다. 최종 9mm 선재는 열간 압연기에 인입시 온도에 따라 항복강도와 연신율은 달랐지만 인장강도는 근사한 값을 나타내었으며 모두 ASTM B863규격을 만족하였다.

非定常 熱線法 에 의한 流體 의 熱傳達率 測定 (Measurement of thermal conductivity of fluid by unsteady hot wire method)

  • 고상근;양상식;노승탁
    • 대한기계학회논문집
    • /
    • 제8권2호
    • /
    • pp.154-161
    • /
    • 1984
  • 본 연구에서는 고정밀 아날로그-디지탈 변환기와 마이크로 프로세서(micropr- ocessor) Intel 8085를 사용하여 비정상 아날로그(analog)신호를 왜곡이 없이 디지탈 량으로 직접 변환하여 자료처리하였다. 또한 비정상 열선법은 열선에 전류를 가하여 열선이 열원이며 동시에 온도계의 두 가지 역할을 하므로, 전기전도성이 있는 액체는 적합하지 못한 단점이 있다. 이를 해결하기 위하여 열선에 얇은 절록피복층을 입혀 전기전도성 액체의 열전도율을 측정할 수 있는 가능성에 대한 연구를 시도하였다.

메탄-공기 예혼합기의 열면점화에 미치는 촉매반응 및 자연대류의 영향 (Effects of Catalytic Reaction and Natural Convection on the Hot Surface Ignition of Methane-Air Mixtures)

  • 김형만;정종수
    • 한국연소학회지
    • /
    • 제2권1호
    • /
    • pp.29-38
    • /
    • 1997
  • In this study, the experimental and numerical investigations of the ignition of methane-air mixtures by a electrically heated wire have been carried out. In order to define the initial condition and make the analysis simple, the following control unit was developed; which heats the wire to the setting temperature in a very short time, and maintains the wire temperature constant until ignition. Experiments with the feedback control have been performed using nickel and platinum wires in normal gravity and microgravity. From experimental results, ignition temperatures in normal gravity are higher than those in microgravity, however, the dependences of ignition temperature on equivalence ratio are not affected by natural convection. Numerical calculations, including catalytic reaction for platinum, have been performed to analyze the experimental results in microgravity. Numerical results show that reactants near platinum wire are consumed by catalytic reaction, therefore, the higher temperature is needed to ignite the mixture with platinum wire.

  • PDF

유속에 따른 열선의 과열비 조정을 통한 열선유속계의 감도향상에 관한 연구 (Sensitivity Enhancement of a Hot-Wire Anemometer by Changing Overheat Ratio with Velocity)

  • 이신표;고상근
    • 대한기계학회논문집
    • /
    • 제19권10호
    • /
    • pp.2678-2689
    • /
    • 1995
  • In this study, a new hot-wire anemometer which has greater sensitivity than that of a constant temperature anemometer (CTA) was proposed. In contrast to CTA, the wire working resistance of the new anemometer increases with flow velocity, that is, the operating mode of the wire becomes variable temperature. The variable temperature anemometer(VTA) was made by substituting a voltage controlled variable resistor such as photoconductive cell or transistor for one of the resistors in the bridge. By positively feeding back the bridge top signal to the input side of these electronic components, the wire overheat ratio could be increased with velocity automatically. Static response analyses of the VTA, constant voltage anemometer (CVA) and CTA were made in detail and calibration experiments were performed to validate the proposed operating principle. The wire operating resistance of the CVA decreases with velocity and this leads to lower sensitivity than that of a CTA. But the sensitivity of the newly proposed VTA is superior to that of a CTA, since the wire overheat ratio increases with velocity. Consequently, it is found that the major factor that is responsible for large sensitivity of a VTA is not the working resistance itself but the change of the wire working resistance with velocity.

3축 열선 PROBE의 특성과 그 평가 (The Characteristics of Triple Hot-Wire Probe and It's Evaluation)

  • 김경훈
    • 한국정밀공학회지
    • /
    • 제5권3호
    • /
    • pp.48-62
    • /
    • 1988
  • A triple hot-wire probe has an essential potentiality for the measure- ment of an instantaneous velocity vector in a three dimensional unsteady flow with large amplitude of velocity fluctuations, the key problems asso- ciated with this instrument are the directional range of applicability and the accuracy. This present paper is concerned with a new method of the techniques of calibration and data processing to estimate the three dimensional flow field using an arbitrary shaped triple hot-wire probe. The method is not based on the assumptions of orthogonality or symmetry and it is especially useful for applications to a hand-made probe where probe geometry is not accurately known. The test application is made to evaluate the effect of cone angles of symmetric non-orthogonal probe.

  • PDF

Dynamic Characteristics of an Unsteady Flow Through a Vortex Tube

  • Kim, Chang-Soo;Sohn, Chang-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • 제20권12호
    • /
    • pp.2209-2217
    • /
    • 2006
  • Dynamic flow characteristics of a counter-flow vortex tube is investigated using hot-wire and piezoelectric transducer (PZT) measurements. The experimental study is conducted over a range of cold air outlet ratios (Y=0.3, 0.5, 0.7, and 1.0) and inlet pressure 0.15 MPa. Temperatures are measured at the cold air outlet and along the vortex tube wall. Hot-wire is located at cold outlet and PZT is installed at inner vortex tube by mounting at throttle valve. The cold outlet temperature results show that the swirl flow of vortex tube is not axisymmetric. The hot-wire and PZT results show that there exist two distinct kinds of frequency, low frequency periodic fluctuations and high frequency periodic fluctuations. It is found that the low frequency fluctuation is consistent with the Helmholtz frequency and the high frequency fluctuation is strongly related with precession oscillation.

회전하는 정사각단면 $90^{\circ}$ 곡덕트 내 내향 난류유동 측정 (Measurement of Inward Turbulent Flows in a Rotating with Square Cross-Section $90^{\circ}$ Duct)

  • 김동철;전건호;최영돈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.627-632
    • /
    • 2000
  • Developing turbulent flows in a rotating 90 degree bend with square cross-section were measured by a hot-wire anemometer. The six orientation hot-wire technique was applied to measured the distributions of 3 mean velocities and 6 Reynolds stress components. Effects of Coriolis and centrifugal forces caused by the curvature and rotation of bend on the mean motion and turbulence structures were experimentally investigated Productive addition of Coriolis and centrifugal forces to the outward radial direction in the entrance region of bend increases the secondary flow intensity according to the rotational speeds. However, after 45 degree of bend, centrifugal force due to the rotation of bend may promote the break down of counter rotating vortex pair into multi-cellular pattern, thereby decreasing the production rate of turbulence energy and Reynolds stresses.

  • PDF

열선 유속계를 이용한 3차원 유동의 계측 방법 (A method for measuring the three-dimensional flows by the hot-wire anemometers)

  • 강신형;유정열;백세진;이승배
    • 대한기계학회논문집
    • /
    • 제11권5호
    • /
    • pp.746-754
    • /
    • 1987
  • 본 연구에서는 X형 프로우브에 Mojolla의 방법을 적용하였으며, 경사프로우브 에는 프로우브의 경사각도와 회전각도에 따른 속도성분과 출력전압과의 관계를 유도하 여 적용하였으며, 이들 방법에 의한 3차원 유동계측의 정확성과 적용법위를 조사하였 다.

나노유체 열전도율의 온도의존성 평가를 위한 비정상열선법의 시험방법 (Validation Test for Transient Hot-wire Method to Evaluate the Temperature Dependence of Nanofluids)

  • 강경민;이신표
    • 대한기계학회논문집B
    • /
    • 제31권4호
    • /
    • pp.341-348
    • /
    • 2007
  • One of the controversial research issues on nanofluids is the temperature dependence of the thermal conductivity of nanofluids, that is, whether it will increase or decrease according to the temperature rise. To evaluate precisely the thermal conductivity behavior of nanofluids, a systematic way of validation experiments for the measuring instrument has been highly recommended. In this paper, procedure of the validation test for transient hot-wire method using the temperature dependence of the base fluids was explained comprehensively and the comparison of the temperature dependence of water-$Al_2O_3$ nanofluids is made between the present work and that of Das et al.