• Title/Summary/Keyword: Hot-water temperature

Search Result 1,033, Processing Time 0.026 seconds

Study on the Comparison of Effects by Extraction Methods of Roast and Raw Semen Zizyphi Spinosae (생산조인(生酸棗仁)과 초산조인(炒酸棗仁)의 추출방법에 따른 효능비교연구)

  • Lee, Eun-Kyoung;Hong, Hak-Gi;Chong, Myong-Soo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.6
    • /
    • pp.1416-1422
    • /
    • 2009
  • To observe the difference and change of the efficacy and ingredient appearing according to whether semen zizyphi spinosae has been roasted and its extraction method, locomotor activity, anticonvulsant activity, sleeping effect of each hot water and UMPM low temperature extracts of roast and raw semen zizyphi spinosae were measured through animal tests. Roast semen zizyphi spinosae showed superior pharmacological efficacy than raw semen zizyphi spinosae. Also, hot water extraction method showed superior pharmacological efficacy than low temperature extraction method(UMPM) that uses ultrasonic waves and microwaves. In short, it was shown that herbal medicine's extraction method needs to maximize medicinal effects by trying optimum extraction methods according to efficacy by considering characteristics of each herbal medicine. Together, there's also the need for in-depth studies on water-soluble ingredients of semen zizyphi spinosae that may be extracted through full hot water extraction method.

Hydrochemical Properties of the Onyang Hot Spring Waters (온양지역 온천수의 수리화학적 특성)

  • Yun, Uk;Cho, Byong Wook;Lee, Cholwoo
    • The Journal of Engineering Geology
    • /
    • v.26 no.4
    • /
    • pp.561-570
    • /
    • 2016
  • For the investigation of hydrochemical changes in hot spring waters from the Onyang hot spring area, we analyzed water chemistry of 24 hot spring waters in 2011 and 2016. The results showed that there is no significant change in temperature and properties of the hot spring waters. The relationship of 2016 between temperature and $SiO_2$ and F reveals a positive trend ($r^2=0.60$, 0.47), and the relationship between temperature and Ca, Mg, Cl, $SO_4$, $HCO_3$, EC reveals a negative trend ($r^2=0.50$, 0.11, 0.50, 0.63, 0.23, 0.51). The relationship between temperature and pH is a positive trend, while the one between temperature and DO is a negative trend, indicating that the source is from deep groundwater. When plotted on Piper diagram, most of which are $Na-HCO_3$ but several hot waters are classified as the $Na(Ca)-HCO_3$, indicating inflow of shallow groundwater was occurred.

Experimental Study on a Low-Temperature Hot Water Capillary Radiant Floor Heating System (저온온수 모세유관 바닥복사 난방시스템의 성능에 관한 실험적 연구)

  • Cho, Jinkyun;Park, Beungyong;Lee, Yongjun;Chong, Wonho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.2
    • /
    • pp.68-82
    • /
    • 2018
  • Radiant floor heating systems with capillary tubes are energy saving systems in which hot water is circulated into capillary tube with a small diameter. In this study, the heating performance of capillary tube system is investigated in an experimental study and a simulation model. The results of the study showed that, the capillary tube radiant floor heating system maintains a more stable floor surface temperature in comparison a PB pipe system. In terms of energy consumption, the capillary tube radiant floor heating system proved to be more efficient than the PB pipe heating system at $40^{\circ}C$ of low temperature hot water supply. The difference between water temperature and room temperature can be held low for heating which saves energy. Low temperature radiant floor heating system with capillary tubes have significant advantages such as health improvement, low energy cost, optimum use of heat source(boiler) and higher operational efficiency.

Effect of Water Temperature on Heat Transfer Characteristic of Spray Cooling on Hot Steel Plate (냉각수온 효과에 따른 고온 강판의 스프레이 냉각 열전달 특성 연구)

  • Lee, Jung-Ho;Yu, Cheong-Hwan;Park, Sang-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.5
    • /
    • pp.503-511
    • /
    • 2011
  • Water spray cooling is a significant technology for cooling of materials from high-temperature up to $900^{\circ}C$. The effects of cooling water temperature on spray cooling are mainly provided for hot steel plate cooling applications in this study. The heat flux measurements are introduced by a novel experimental technique that has a function of heat flux gauge in which test block assemblies are used to measure the heat flux distribution on the surface. The spray is produced by a fullcone nozzle and experiments are performed at fixed water impact density of G and fixed nozzle-totarget spacing. The results show that effects of water temperature on forced boiling heat transfer characteristics are presented for five different water temperatures between 5 to $45^{\circ}C$. The local heat flux curves and heat transfer coefficients are also provided to a benchmark data for the actual spray cooling of hot steel plate cooling applications.

Characteristics of Long-term Water Quality Trend of Dongrae Hot Spring (동래온천의 장기적인 수질 변동 특성)

  • Jeon, Hang-Tak;Hamm, Se-Yeong;Lee, Cholwoo;Lee, Jong-Tae;Lee, Jeong Rak
    • The Journal of Engineering Geology
    • /
    • v.30 no.3
    • /
    • pp.379-397
    • /
    • 2020
  • In this study, Long-term change of water quality in Donrae Hot Spring was characterized using water quality data from 1922 to 2019. According to Mann-Kendall analysis and Sen's slope using long-term water quality data of Dongnae Hot Spring from 1922 to 2019, temperature, Ca, SiO2, and HCO3 show an increasing trend whereas EC, Na, K, Mg, Cl, and SO4 show a decreasing trend or negligible trend. In addition, the water type of Dongnae Hot Spring stably belongs to Na-Cl type over time. The spatial distributions of water temperature and chemical constituents in 2004, 2009, 2014, and 2019 show variable patterns with showing some difference depending on sampling locations in different years. These results indicate that despite the long-term pumping of the hot spring water, the water quality is quite stable during the entire study period.

Freeze Protection for Passive Solar Water Heating System (자연순환형 태양열온수기 동파방지기술)

  • Kim, Jong-Hyun;Hong, Hi-Ki;Chung, Jae-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.5
    • /
    • pp.327-333
    • /
    • 2011
  • In the present work, a new freeze protection method has been proposed for a natural circulation system of solar water heater. Though electrothermal wire is popularly used for the purpose, there are freezing troubles by wire cut-off and shortage of excessive electric power consumption. In the experimental device, hot water in storage tank was used to heat the outlet pipe from the tank if the pipe surface temperature falls lower than a set point. The cold water pipe to the storage tank was installed to directly contact the hot water pipe surface temperature rose by transferred heat.

Pre-extraction of Hemicelluloses from Korean Mixed Hardwood Chips Using Hot Water and Alkali Solution and its Characteristics (열수 및 알칼리 용액을 이용한 국산 목재 칩으로부터 헤미셀룰로오스의 선추출 및 특성 구명)

  • Cho, Hwi;Shin, Hee-Nae;Sim, Kyu-Jeong;Youn, Hye-Jung;Lee, Hak-Lae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.43 no.1
    • /
    • pp.83-91
    • /
    • 2011
  • Hemicelluloses are useful materials for papermaking and other biotechnological applications. To recover and further utilize the hemicelluloses, this study carried out the pre-extraction of the hemicelluloses from Korean mixed hardwoods chips using hot water and sodium hydroxide solution at various temperature and time conditions. Through the hot water pre-extraction, the wood components of 22% was extracted and the 35% of the hemicelluloses which were contained in the original wood chips were dissolved into the pre-extractives. The yield of the pre-extractives was more significantly influenced by the pre-extraction temperature than the time. The pre-extractives with the yield of 30% could be obtained by alkali pre-extraction and alkali concentration was the most important factor. It had lower hemicellulose content but high molecular weight, compared with the hot water pre-extractives.

A Study on the High Temperature Properties (Compressive Strength, Expansion) of Synthetic Sand using Domestic Silica Sand (Mooryang Silica Sand) (국내규사(國內硅砂)를 사용(使用)한 합성사(合成砂)의 고온성질(高溫性質) (압축강도(壓縮强度), 팽장(膨張)) 에 관(關)한 연구(硏究))

  • Yun, Byung-Guk;Lee, Kye-Wan
    • Journal of Korea Foundry Society
    • /
    • v.2 no.4
    • /
    • pp.2-8
    • /
    • 1982
  • The behavior of sand and mold at high temperatures was generally agreed to importantly affect the quality of castings made. By changing water content through 2,4,6 and 8%, and bentonite content through 5,7,9 and 11%, specimens have been made according to the respective composition. Specimens have been subjected to hot compressive strength and thermal expansion at 400, 600, 800 and $1000^{\circ}C$ respectively. The results obtained were as follows ; 1. At each temperature, thermal expansion decreased and hot compressive strength increased with the increase in water content. 2. After thermal expansion was peaked at approximately $1000^{\circ}C$ the contraction and maximum hot compressive strength appeared. 3. At each temperature, maximum hot compressive strength appeared 2%, 4,6% and 8% water content for 7%, 9% and 11% bentonite content respectively. 4. When 2% $H_2O$ was added, though bentonite content was increased, hot compressive strength did not rarely change. 5. Until the thermal expansion was completed the required time was 15-18 minutes at $400^{\circ}C$ and $600^{\circ}C$, and 10-13 minutes at $800^{\circ}C$. At $1000^{\circ}C$, the required time was 7-9 minutes in order to gain the maximum expansion, after that, contraction proceeded during 3-4 minutes before expansion was completed.

  • PDF

A Study on Flow and Mixing Caracteristics according to Hot Water Extraction (온수 추출에 따른 유동 및 혼합 특성에 관한 연구)

  • 장영근;박이동;김철주;황영규
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.53-59
    • /
    • 1995
  • In a hot water extraction process, the flow pattern of upper region in a storage tank is a major reason of mixing between hot water and cold water. In this study, the temperature distribution in a storage tank was measured to predict the flow pattern of upper region, and the degree of stratification was analysed to the variables dominating a extraction process. And also, it was found that the degree of stratification improved expecially in a low flow rate in case of using modified distributor I(DMI) as a outlet port type.

  • PDF

An experimental study on the heat transfer characteristics of a Ondol-heated space by varying pipe embedding depths and hot water supply conditions (보일러 운전조건 및 마감층 두께 변화에 따른 온돌난방공간의 열특성에 관한 실험연구)

  • 박병윤
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 1991.09a
    • /
    • pp.41-47
    • /
    • 1991
  • This study reports the results of the transient temperature response of a floor heating panel according to variation of the hot water supply temperature and the pipe embedding depth. Also, this experiment compares the temperature responses of floor heating panels under the continuous and intermittent heating system. Furtthermore, this study presents some details of the thermal response of Ondol-heated buildings to varying loads and patterns of heat input. The analysis of the thermal performance fo Ondol heating system have been presented.

  • PDF