• 제목/요약/키워드: Hot-water heating system

검색결과 324건 처리시간 0.047초

스마트시티 에너지 감시를 위한 CIM(Common Information Model) 프로파일 설계 (Design of CIM(Common Information Model) Profile for Smart City Energy Monitoring)

  • 김영일;채창훈;김예리;이지훈
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.127-135
    • /
    • 2022
  • With the advent of high technologies such as the 4th Industrial Revolution and artificial intelligence and big data, efforts are being made to solve urban problems and improve the quality of life by applying new technologies in the smart city field. In addition, as carbon neutrality has emerged as an important issue due to global warming, smart city energy platform technologies such as urban energy management, efficiency improvement, and carbon reduction are in the spotlight. In order to effectively manage urban energy, energy resource information such as electricity, water, gas, hot water, heating, etc. must be collected from the management system of various energy utilities and managed on the central platform. The centrally integrated data is delivered to external city management systems that require city energy information through an energy platform. This study developed a CIM profile for smart city energy monitoring required to provide energy data to external systems. Electric data model were designed using the CIM class of IEC 61970, and water, gas, and heat data model were designed in compliance with the UML-based design ideas of IEC 61970.

건물 단지에 대한 에너지 수요 예측 프로그램 개발 (Development of a Building Energy Demand Estimator)

  • 정모;박화춘;임용훈
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.127-132
    • /
    • 2009
  • A Microsoft Access application program is developed to calculate energy demands for a Community Energy System (CES) composed of various types of buildings. The field-measured heating, hot water, cooling, and electricity energy consumptions for 14 types of building are systematically organized in forms of database and hourly loads for a span of year (8760 hours) are generated through an automated statistical procedure. User-friendly standard windows interfaces are provided to assist non-expert end users.

  • PDF

건물 단지에 대한 에너지 수요 예측 데이터베이스 응용 프로그램 개발 (Development of a Energy Demand Estimator for Community Energy Systems)

  • 정모;박화춘
    • 한국태양에너지학회 논문집
    • /
    • 제29권3호
    • /
    • pp.37-44
    • /
    • 2009
  • The field-surveyed and measured energy consumption data is processed to develop building energy demand models for heating, hot water, cooling, and electricity. The load models are systematically organized as a database and hourly loads for a span of year (8760 hours) are generated by the program. Rased on those models a Microsoft Access application program is developed to calculate energy demands for a Community Energy System (CES) composed of 17 types of buildings. User-friendly interfaces are provided to assist non-expert end users and necessary tools to link the calculation results to subsequent coagulations such as operation simulation or economic assessment.

LabVIEW를 이용한 열병합 발전의 열.전기 제어 시스템 (Heat.Power Control System of Cogeneration using LabVIEW)

  • 이송근;김일주;이규화
    • 조명전기설비학회논문지
    • /
    • 제23권8호
    • /
    • pp.93-98
    • /
    • 2009
  • 열병합발전은 전기와 열을 동시에 발생시켜 에너지 이용률을 높이는 고효율에너지 발전 체계를 말하며, 시스템에 전기에너지를 공급하는 과정에서 배출되는 에너지를 회수하여 산업용 공정, 지역난방, 온수 공급 등에 이용함으로써 종합효율 향상에 많은 영향을 끼친다. 본 논문에서는 LabVIEW를 이용하여 열병합 발전의 흐름을 화면으로 보이고, TCP/IP 통신을 이용하여 지역에너지 시스템을 원거리에서도 제어가 가능한 열 전기 제어 시스템을 보이고자 한다. 열 전기 제어 시스템이 원거리에서 제어가 가능함을 보이기 위해 4대의 컴퓨터로 시뮬레이션을 보였다.

응축형 가스보일러시스템의 제어 알고리즘 개발을 위한 효과적인 동적모델 (Effective Dynamic Models for the Development of Control Algorithms of a Condensing Gas Boiler System)

  • 한도영;김성학
    • 설비공학논문집
    • /
    • 제20권6호
    • /
    • pp.365-371
    • /
    • 2008
  • Condensing gas boiler units may make a big role for the reduction of energy consumption in heating industries. In order to decrease the energy consumption of a condensing gas boiler unit, effective operations of the system are necessary. In this study, mathematical models of a condensing gas boiler system were developed in order to develop control algorithms of the system. These include dynamic models of a blower, a gas valve, a pump, a burner, a boiler heat exchanger, and a hot water heat exchanger. Control algorithms of a blower, a gas valve, and a pump were also assumed. Simulation results showed good predictions of dynamic behaviors of a boiler system. Therefore, the simulation program developed for this study may be effectively used for the development of control algorithms of a boiler system.

온실 태양잉여열을 이용한 히트펌프시스템의 난방 성능평가에 관한 실증 연구 (Empirical evaluation of the heating performance by a heat pump system with surplus heat from a greenhouse)

  • 전병용;박윤철;고광수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제41권1호
    • /
    • pp.99-104
    • /
    • 2017
  • 본 연구는 태양일사에 의하여 가열되는 온실상단에 고온의 태양잉여열을 축열조에 축열한 후 이를 이용하여 온실을 난방하는 히트펌프시스템의 실증연구에 관한 것으로 히트펌프시스템은 축열조를 구비하고, 각종 열교환을 위한 판형열교환기, 팬코일유닛 그리고 부가적인 에너지원으로 태양일사를 직접 집열할 수 있는 태양집열기로 구성되어 있다. 히트펌프시스템은 R410a냉매를 사용하며 일반적인 히트펌프시스템과 마찬가지로 외기열원만으로도 운전될 수 있으며, 온실내부의 설정온도에 따른 제어로직에 따라 외부조작없이 온실상단열의 축열운전, 외기공기에 의한 외기열원 및 축열조의 온수를 히트펌프의 작동 없이 난방하는 다수의 운전방식이 자동적으로 운전되도록 하였다. 개발된 축열식 히트펌프의 현장평가 성능실험을 위하여 제주시 조천리에 있는 $100m^2$ 크기의 온실에 설치하고 10월부터 12월까지 운전하였다. 실증연구 실험을 수행한 결과로써 외기열원을 이용하여 난방 할 경우 난방열량은 19.9 kW의 용량을 얻을 수 있었으며, 온실상단의 잉여열에 의하여 축열조의 온수로 히트펌프운전 없이 직접 난방 할 경우에 난방열량은 21.4 kW로 외기난방과 비슷한 난방용량을 나타내는 것을 알 수 있었다.

연속식 마이크로파 고온단시간 살균시스템에서 우유의 살균효과 (Pasteurization Efficiency of a Continuous Microwave HTST)

  • 김석신;이주희;김상용
    • 한국식품과학회지
    • /
    • 제31권5호
    • /
    • pp.1392-1396
    • /
    • 1999
  • 우유의 저온살균시 품질손상의 원인이 되는 fouling발생을 극소화시키면서 균을 사멸시키기 위하여 마이크로파를 이용한 우유의 살균에 대한 연구를 시도하였다. 이에따라 연속식 마이크로파 HTST 시스템을 설계 제작한 후, 우유를 HTST$(72^{circ}C$, 15초)법으로 살균하되 열수만을 이용한 경우(MP0)와 마이크로파로 온도를 올린 후 열수에서 holding한 경우(MP1)와 마이크로파만을 활용한 경우(MP2)의 세가지로 구분하여 미생물의 사멸효과를 총생균수, 대장균수, 저온성세균수 및 phosphatase 활성으로 구분하여 비교해 보았다. 총균수와 저온성 세균수의 경우 세가지 HTST살균법 모두 살균후 초기균수의 3 log 정도 감소하는 살균효과를 보여주었다. 살균방법별 살균효과는 MP0>MP2>MP1의 순서를 보였고 유의차(p<0.05)도 있는 것으로 나타났으나 원유의 초기미생물수와 함께 통계처리할 경우는 살균방법 사이의 유의차는 보이지 않았다. 대장균과 phosphatase activity의 경우 세가지 HTST 살균법 모두 살균후 우유의 배양실험에서 대장균 집락이 확인되지 않거나 살균후 음성(negative)인 것으로 나타나 살균방법 사이의 살균효과에 차이가 없음을 확인시켜주었다. 따라서 마이크로파 단독처리(MP2) 또는 마이크로파로 승온시킨 후 원하는 온도에서 holding하는 병용법(MP1)을 활용할 경우 통상적 HTST법에서 문제가 되는 fouling을 방지하면서 거의 대등한 살균효과를 얻을 수 있을 것으로 예상하였다 얻어진 연구결과를 토대로 우유 및 타 액상식품의 살균에도 확대 적용할 수 있으리라 기대된다.

  • PDF

설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

유리온실과 플라스틱 온실의 환경조절시스템 비교분석 (Comparative analysis on environment control systems for glasshouses and plastic houses)

  • 남상운;신현호;서동욱;유인호
    • 농업과학연구
    • /
    • 제41권3호
    • /
    • pp.251-258
    • /
    • 2014
  • In order to set up the basic environmental control systems which the new concept greenhouses have to equip, greenhouse characteristics, environmental management and control systems in domestic glasshouses and plastic houses were investigated and analyzed comparatively. Survey results on the width, length, eaves height, and the number of spans etc. showed that glasshouses were bigger than plastic houses significantly. New concept greenhouses claim to be plastic houses, but it will be reasonable to follow the specifications of the glasshouse. Specifications to be applied to new concept greenhouses were proposed as follows; hot water heating systems, aluminum screens as the thermal curtain, evaporative cooling systems, roof vents on the ridge, circulation fans, $CO_2$ enrichment, hydroponic systems, and automatic irrigation control systems. Environmental measurement systems for the indoor and outdoor temperature, humidity, light, wind speed and indoor $CO_2$ concentration have to be fully equipped. The automatic control system has to be as a complex environmental control system, not a single item control system. Also, for stable dissemination, domestically producing complete greenhouse control system should be made as soon as possible.

하수처리수를 이용한 2단 압축 열펌프 시스템의 운전특성에 관한 연구 (A Study on The Operation Characteristics of 2-Stage Compression Heat Pump using Treated sewage)

  • 김지영;백영진;이영수;장기창;나호상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.299-303
    • /
    • 2008
  • The treated sewage temperature is about $5^{\circ}C$ lower in summer and $5{\sim}10^{\circ}C$ higher in winter than ambient air. It can be used heat pump heat source and is good heat source on high performance of heat pump. In this study, to develop 100RT 2-stage compression heat pump use treated sewage water heat source and system applies to sewage disposal plant. Although heat pump is better performance, the large temperature difference between load and source makes the performance degradation of a heat pump. To solve this problem screw 2-stage compression is considered. The experiment was focused on the system operating performance variations over supply water and treated sewage water a temperature in the field. The results show that system of heating performance is higher then general heat pump and is enough to supply a hot water of $70^{\circ}C$.

  • PDF