• 제목/요약/키워드: Hot-gas bypass defrost

검색결과 3건 처리시간 0.015초

하이브리드 제상 방식을 적용한 냉장고용 핀-관 열교환기의 제상 성능 평가 (Performance Evaluation of the Hybrid Defrost Process in the Fin-Tube Evaporators of Refrigerators)

  • 이수원;박용주;권래언;정영만;이재근
    • 설비공학논문집
    • /
    • 제23권1호
    • /
    • pp.38-46
    • /
    • 2011
  • The hybrid defrost process combined with hot-gas bypass defrost and electric heater defrost was experimentally evaluated about its defrost performance in the fin-tube evaporators of household refrigerators. Also the hybrid defrost process was compared with only electric heater defrost process. The defrost efficiency of the hybrid defrost process was shown two times higher than electric heater defrost process. The defrost time of the hybrid defrost process was shorten about 10%~50% than electric heater defrost process. Thermal shock after defrost process was decreased about 50% for the case of the hybrid defrost. It was found that energy consumption ratio of defrost process was reduced up to 7.4% compared with 22.4% of electric heater defrost at the condition of $25^{\circ}C$ ambient temperature.

고온냉매 우회방법을 적용한 열펌프의 성능 개선 연구 (A Study on Performance Improvement of Heat Pump Adopting the Hot Gas Bypass Method)

  • 강신형;변주석
    • 에너지공학
    • /
    • 제15권4호
    • /
    • pp.235-242
    • /
    • 2006
  • 본 연구는 공기 열원 열펌프의 성능 향상을 위한 연구로써 제상 방법으로 고온냉매 우회방법을 사용하고 내부열교환기를 장착한 열펌프 시스템의 성능을 ISO5151의 표준제상 조건에서 실험하였다. 실험은 고온냉매 우회방법과 가장 일반적인 제상 방법인 시간주기 제상방법을 비교하였으며 착상 발생 후 압축기 출구의 고온냉매를 실외기 입구로 우회시킬 때 실외기 홴 속도를 정상속도에 대하여 0%, 30%, 60%, 90%로 변화 시키면서 열펌프의 성능변화를 관찰하였다. 연구결과 210분의 열펌프 가동시간 동안 고온냉매 우회방법은 시간주기 제상방법 보다 $2.2{\sim}6%$ 높은 평균 성능계수를 나타냈으며 고온냉매 우회방법에서는 실외기의 홴 속도가 60%일 때 가장 좋은 성능계수와 난방용량을 나타냈다.