• 제목/요약/키워드: Hot-air dry

Search Result 136, Processing Time 0.025 seconds

Test and Evaluation for the Mixing Quality in the Premixer of DLE Combustor (DLE(Dry Low Emission) 연소기 예혼합기의 혼합성능 예측에 대한 시험 평가)

  • 최장수;박동준;우유철
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.2 no.2
    • /
    • pp.99-107
    • /
    • 1998
  • A test on venturi-type premixer of ASE120 engine combustor has been performed to evaluate its mixing performance. Cold air was supplied into the premixer through the fuel nozzle and mixed with the hot air from the compressor exit. The measured temperature of the mixed air was used to evaluate the mixedness. DOE(Design of Experiment) technique was utilized to make a test matrix of variables and to determine the optimum combination of variables, which was verified through a confirmation test.

  • PDF

A Study on Air Flow Analysis for the Internal Space of the Dehumidifying Air-Conditioning System with A Membrane (분리막 제습공조시스템의 내부 유동 해석에 관한 연구)

  • Jung, Yong-Ho;Park, Seong-Ryong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.12
    • /
    • pp.620-625
    • /
    • 2015
  • The summer climate is very hot and humid in Korea. Humidity is an important factor in determining thermal comfort. Recently, research on dehumidification device development has been attempted to save the energy required for operating the dehumidifier. Existing dehumidification systems have disadvantages such as wasting energy to drive the compressor. Meanwhile, dehumidification systems with membranes can dehumidify humid air without increasing the dry bulb temperature. Therefore. they don't have to consume cooling energy. In this paper, the installation conditions for a membrane system were analyzed to improve the shape and optimum performance of the system. The results showed that the distance between elements was the critical system design factor, and that a distance of 20 mm was the optimal condition for the pressure drop and flow characteristics of the internal air flow.

Influence of Drought and High Temperature on the Physiological Response and Yield in Hot Pepper (토양 건조 스트레스와 기온상승에 의한 고추의 생리반응 및 생산량 변화)

  • Lee, Sang Gyu;Lee, Hee Ju;Kim, Sung Kyeom;Mun, Bo heum;Lee, Jin Hyoung;Lee, Hee Su;Do, Kyung Ran
    • Journal of Environmental Science International
    • /
    • v.27 no.4
    • /
    • pp.251-259
    • /
    • 2018
  • This study was conducted to determine the effects of combination of air temperature and soil water content on the growth, physiological disorder rate, and yield of hot peppers. The study was carried out in a typical plastic house (open on one side and with ventilation fans on the other side), which was maintained with gradient air temperature (maximum difference in air temperature: $6^{\circ}C$). The deficit irrigation (DI) treatment commenced 65 days after transplanting. The height of plant and fresh and dry weights of the stem increased at high air temperature (ambient + $6^{\circ}C$, extreme high temperature; EHT). Furthermore, the leaf area decreased significantly with the DI treatment. There were no significant differences in the stem diameter, number of branches, and fresh and dry weights of the leaves among all the treatments. The net photosynthesis rate of the full irrigation (FI) treatment was higher than that of the DI treatment. The photosynthesis rate at ambient air temperature was $19.7{\mu}mol\;CO_2m^{-2}{\cdot}s^{-1}$, the highest among all the treatments; however, the photosynthesis rate of the EHT treatment decreased by 60% ($12.3{\mu}mol\;CO_2m^{-2}{\cdot}s^{-1}$). Additionally, the formation of guard cells in the leaf was abnormal with the EHT treatment, and there was a decrease in translocation efficiency. The effects of air temperature treatment were more pronounced on the physiological disorder rate and yield. The physiological disorder rate of the EHT treatment was the highest under the DI treatment condition. The yield of the AFI (ambient air temperature with full irrigation) treatment was 3,771 kg/10a, the highest among all the treatments; however, the yield of the EHT treatment with DI and FI was 1,282 and 1,327 kg/10a, respectively. These results indicate that growth and physiological disorder rate improved with the EHT treatment; however, there was a decrease in yield. Furthermore, the formation of guard cells was abnormal and malfunctional.

Design and Exergy Analysis for a Combined Cycle of Liquid/Solid $CO_2$ Production and Gas Turbine using LNG Cold/Hot Energy

  • Lee, Geun-Sik
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.1
    • /
    • pp.34-45
    • /
    • 2007
  • In order to reduce the compression power and to use the overall energy contained in LNG effectively, a combined cycle is devised and simulated. The combined cycle is composed of two cycles; one is an open cycle of liquid/solid carbon dioxide production cycle utilizing LNG cold energy in $CO_2$ condenser and the other is a closed cycle gas turbine which supplies power to the $CO_2$ cycle, utilizes LNG cold energy for lowering the compressor inlet temperature, and uses the heating value of LNG at the burner. The power consumed for the $CO_2$ cycle is investigated in terms of a solid $CO_2$ production ratio. The present study shows that much reduction in both $CO_2$ compression power (only 35% of the power used in conventional dry ice production cycle) and $CO_2$ condenser pressure could be achieved by utilizing LNG cold energy and that high cycle efficiency (55.3% at maximum power condition) in the gas turbine could be accomplished with the adoption of compressor inlet cooling and regenerator. Exergy analysis shows that irreversibility in the combined cycle increases linearly as a solid $CO_2$ production ratio increases and most of the irreversibility occurs in the condenser and the heat exchanger for compressor inlet cooling. Hence, incoming LNG cold energy to the above components should be used more effectively.

Effects of Yam on Lowering Cholesterol Level and Its Mechanism (마(Dioscorea)의 콜레스테롤 저하작용 및 그 작용기전)

  • 권정숙
    • Journal of Nutrition and Health
    • /
    • v.32 no.6
    • /
    • pp.637-643
    • /
    • 1999
  • The effects of yam(Dioscorea) on lowering cholesterol level and its mechanism were investigated. The concentrations of plasma and liver lipids, and the excretions of fecal neutral sterol and bile acid were measured in male Sprague-Dawley rats. Five Groups of 8 rats were fed hypercholesterolemic diet(1% cholesterol, 10% lard ; control), hypercholesterolemic diet plus 15% or 30% dried yam powder prepared by either hot-air(15HY, 30HY) or freeze dry(15FY, 30FY) for 4wk. Plasma total lipid, total cholesterol and cholesterol level was also significantly lower(28%, p<0.05), buy HMG-CoA reductase activity was higher in 30FY(230%, p<0.05) than in control. Although no significant differences in fecal neutral sterols were observed among groups, the yam-fed rats apparently had less bacterial degradation of cholesterol as indicated by a significantly greater of fecal cholesterol to coprostanol than in controls. Total fecal bile acids were significantly greater in rats fed yam(15HY : 5 folds, 15FY ; 12,30HY ; 12, 20FY ; 22) than in controls. The ratio of secondary to primary bile acids was almost 8 times lower in 30FY than in control. These data indicate that yam lowers cholesterol both in plasma and in liver through increasing fecal bile acid excretion as well as HMG-CoA reductase activity. Freeze-dried yam, which possesses viscosity, was more effective in cholesterol-lowering action than hot-air dried one.

  • PDF

Three-dimensional Distribution and Variation of Moisture Content of Boxed-heart Square Timber of Pinus densiflora During Drying (소나무 수심 정각재의 건조 중 3차원 함수율 분포와 변이)

  • Kang, Wook;Lee, Hyoung-Woo;Chung, Woo-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.7-14
    • /
    • 2006
  • Three-dimensional distribution and variation of moisture content of boxed-heart square timber of Pinus densiflora was investigated to find the safe and rapid drying methods. As results, microwave-drying method could dry the boxed-heart square timber with sectional dimension of $150{\times}150mm$ under 10% moisture content (MC) within 72 hours with less surface checks, compared with hot-air drying. In case of microwave drying, the MC distribution during drying had a close relation with the initial MC distribution. In case of hot air drying, however, it was independent on the intial one except for the intial drying stage.

Predicting the Effective Thermal Conductivity of Sand-Water Mixtures Used for Grouting Materials (그라우팅 재료로 사용되는 모래-물 혼합물의 열전도도 예측)

  • Sohn, Byong-Hu;Lim, Hyo-Jae
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.761-768
    • /
    • 2008
  • This paper presents the results of a laboratory study on the thermal conductivity of sand(silica, quartzite, limestone, sandstone, granite and masonry sand)-water mixtures used in ground heat exchanger backfilling materials. Nearly 260 tests were performed in a thermal conductivity measuring system to characterize the relationships between the thermal conductivity of mixtures and the water content. The experimental results show that the thermal conductivity of mixtures increases with increasing dry density and with increasing water content. The most widely used empirical prediction models for thermal conductivity of soils were found inappropriate to estimate the thermal conductivity of unsaturated sand-water mixtures. An improved model using a exponential relationship to compute the thermal conductivity of dry sands and empirical relationship to assess the normalized thermal conductivity of unsaturated sand-water mixtures is presented.

  • PDF

An Experimental Study on the Performance of a Cross-Flow-Type, Indirect Evaporative Cooler Made of Paper/Plastic Film (종이와 플라스틱 필름의 이종 재질로 구성된 직교류형 간접증발소자의 성능에 대한 실험적 연구)

  • Kwon, Mi-Hye;Go, Min-Geon;Kim, Nae-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.9
    • /
    • pp.475-483
    • /
    • 2015
  • In Korea, a typically hot and humid summer means that air-conditioners consume a large quantity of electricity; accordingly, the simultaneous usage of an indirect evaporative cooler may reduce the sensible-heat level and save the amount of electricity that is consumed. In this study, the heat-transfer and pressure-drop characteristics of an indirect evaporative cooler made of paper/plastic film were investigated under both dry and wet conditions; for the purpose of comparison, an indirect evaporative cooler made of plastic film was also tested. Our results show that the indirect evaporative efficiencies under a wet condition are greater than those under a dry condition, and the efficiencies of the paper/plastic sample (109% to 138%) are greater than those (67% to 89%) of the plastic sample; in addition, the wet-surface, indirect evaporative efficiencies of the paper/plastic sample are 32% to 36% greater than those of the plastic sample. Further, the wet-surface pressure drops of the paper/plastic sample are 13% to 23% larger than those of the plastic sample, and this might have been caused by the surface roughness of the samples. A rigorous heat-transfer analysis revealed that, for the plastic sample, 30% to 37% of the wet channels remained dry, whereas all of the channels were wet for the paper/plastic sample.

The Effect of Blast Drying System on Garlic just after Harvest (마늘의 수확직후(收穫直後)의 열풍건조(熱風乾燥) 효과(效果))

  • Lee, Woo Sung;Lee, Byung Chul
    • Current Research on Agriculture and Life Sciences
    • /
    • v.1
    • /
    • pp.151-158
    • /
    • 1983
  • This study was performed to obtain a basic materials for improvement of garlic storage ability. The "Namhae jaerae" of southern strain and the "Dalsung jaerae" of northern strain were harvested by period, their stems were cut at 7cm and 25cm from disk and then placed them in blast drying system 12 hours per day at $40^{\circ}C$ for 4 days, or in natural state. The decrease rate of bulb weight was compared and rooting, sprouting, the rate of decay was investigated between natural dry(conventional method) and hot-air dry (blast drying system). The results obtained were as follows. In the case of the decrease rate of bulb weight after hot-air dry; 7cm plot" "Namhae jaerae" was similiar to one of 13th day of natural dry and 25cm plot 14th day. In "Dalsung jaerae" 7cm plot of early, common and late harvest was respectively similiar to one of 22nd, 18th and 16th day of natural dry, 25cm plot of early, common and late harvest showed the same decrease rate of bulb weight as that of 18th, 16th and 14th day of natural dry respectively. In the case of rooting and sprouting in sand culture at the early period of storage, hot-air dry showed more prolonged tendency than conventional drying method. In the case of clove state in the latter period of storage, number of eatable cloves was more numerous and number of decayed cloves were less in blast drying system than in conventional method.

  • PDF

Prediction of Latent Heat Load Reduction Effect of the Dehumidifying Air-Conditioning System with Membrane (분리막 제습공조시스템의 잠열부하 저감효과 예측)

  • Jung, Yong-Ho;Park, Seong-Ryong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.1
    • /
    • pp.15-20
    • /
    • 2017
  • The summer climate is very hot and humid in Korea. The humidity is an important factor in determining thermal comfort. Recently, the research for dehumidification device development has been attempted to save energy that is required for the operation of the current dehumidifiers on the market. Existing dehumidification systems have disadvantages such as wasting energy to drive a compressor. Meanwhile, dehumidification systems with membranes can dehumidify humid air without increasing the dry bulb temperature so it doesn't have to consume cooling energy. In this paper, the cooling energy savings was studied when a dehumidification system was applied in a model building instead of a chiller. The sensible heat load was almost the same result, but the latent heat load was decreased by 38.9% and the total heat load was decreased by 8.5%. As a result, electric energy used to drive the compressor in a chiller was saved by applying a membrane air-conditioning system instead.