• 제목/요약/키워드: Hot-Spot Analysis

검색결과 255건 처리시간 0.032초

블록의 리프팅 동적 구조해석을 위한 다물체 동역학 프로그램의 내장형 자동화 라이브러리 개발 (Development of an Automation Library in Multi-Body Dynamics Program for Dynamic Structural Analysis of Block Lifting Process)

  • 정다운;차주환;송창용;이충형
    • 대한조선학회논문집
    • /
    • 제53권2호
    • /
    • pp.135-143
    • /
    • 2016
  • In this study, an embedded system composed of equipment setting, block importing, scenario setting and output reporting is developed in multi-body dynamics program, ADAMS, for conducting dynamic structural analysis of block lifting process. First, equipment used for block lifting process is set in the simulation environment and the shapes and functions of two lifting beams, and six block loaders are provided as the equipment. Second, the modal analysis result of the lifting block is imported from the static structural analysis system, NASTRAN. Third, the lifting scenarios, such as hoisting, waiting, trolley moving, and wire connecting, are set in the system. Finally, output results in the forms of plots, texts and tables, are reported after the dynamic structural analysis. The test examples conducted in a shipyard are applied into the developed system in various condition and scenarios. The loads at the lug points, the stress contours, and the hot spot tables of the developed system are compared with the result of the static analysis system.

수치해석을 통한 용접구조물의 구조응력 추정에 관한 연구 (On the Numerical Procedure for Estimating Structural Stress of Welded Structures)

  • 강성원;김명현
    • 대한조선학회논문집
    • /
    • 제42권4호
    • /
    • pp.388-395
    • /
    • 2005
  • A numerical procedure is proposed as a mesh-size insensitive structural stress definition that gives a stress state at a weld toe with relatively large mesh size. The structural stress values obtained using different finite element types, i.e. shell element and solid element, are examined for typical weld structures. The calculation procedures are performed using the balanced nodal forces and moments obtained from finite element solutions. A consistent formulation based on work equivalent argument has been implemented to transform the balanced nodal forces and moments from shell to line force and line moments at each nodal position. The mesh-insensitivity, the effect of distance $\delta$(where the stress is calculated) and the potential limitations of the structural stress method are examined for various types of weldments. Based on the results from this study, it is expected to develop a more precise stress estimation technique for fatigue strength assessment of welded structures.

CFD를 이용한 환경친화형 전력용 변압기의 열유동해석 (Thermal Fluid Flow Analysis of Environment-Friendly Power Transformer Using CFD)

  • 김지호;김종왕;권동진;우정욱;구교선;이향범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.924-925
    • /
    • 2011
  • 본 논문에서는 환경친화적이고, 인화점 및 발화점이 높아 화재의 위험도가 낮은 식물성 절연우를 기존 변압기의 광유를 대체로 사용하기 위한 열적 특성을 열유동해석을 이용하여 온도분포를 수치해석을 통하여 예측하였다. 해석모델로는 154kV 급 단상 내철형 유입자냉식 변압기를 대상으로 CFD 해석을 수행하였으며, 광유와 식물성 절연유는 부하의 변화에 따른 온도특성을 파악하는 동시에 핫스팟(hot spot)을 예측하였다. 본 논문은 변압기를 3차원 모델링하여 유동 및 온도 분포를 해석한 결과, 변압기의 내부 온도 및 핫스팟 추적에 대하여 변압기의 수명에 대한 예측이 가능하며, 식물성 절연유를 사용한 전력용 변압기 온도 분포 해석결과는 식물성 절연유의 적용 및 냉각 설계 변경에 기초자료롤 활용될 것이다.

  • PDF

하이드로포밍용 열연 강재의 레이저 용접성 및 성형 특성 (Laser Weldability and Formability of Hot Rolled Steels for Hydroforming Applications)

  • 이원범;이종봉
    • Journal of Welding and Joining
    • /
    • 제22권6호
    • /
    • pp.19-24
    • /
    • 2004
  • The laser welding and its analysis of thin-sheet carbon steels were carried out with high power $CO_{2}$ laser. The main factor of weld quality of laser welding is gap and edge quality. This work was preformed to focus on the gap tolerance problem during laser welding. First, bead on plate welding of thin sheet was examined to investigate the effect of laser welding variables, and to obtain optimum welding condition. Butt welding was also carried out to show the effect of gap on the laser weldability of thin sheet. In order to investigate the effect of gap on formability of welded thin sheet, LDH test was caried out. At high welding speed, the partial penetration was obtained by low heat input. Otherwise, porosity was formed in the bead at low weld speed because of too much heat input. The optimum welding condition of welding was derived from bead width, penetration and hardness property. The maximum gap tolerance on laser welding was observed to be about 0.2mm. This gap size has good relationship with beam size of laser spot(about 0.3mm). The formability of welded sheet was about $80{\%}$ value of base metal and the gap size has not affected on the formability, although weld quality is dependent on the gap size.

구조응력기반 마스터 피로 선도를 이용한 하중 비전달형 십자 필렛 용접조인트의 피로예측 (Fatigue Life Prediction of Non-Load-Carrying Cruciform Welded Joint using Master S-N Curve based on Structural Stress Approach)

  • 곽시영
    • Journal of Welding and Joining
    • /
    • 제33권6호
    • /
    • pp.49-54
    • /
    • 2015
  • Welding process is of importance to assemble products or structures, but also the process is structural weakness due to stress concentration in welding joint. The fatigue design of welded joint requires time & labor consuming fatigue test because the fatigue life is various according to the depth of joint, joint type and load type etc. In fatigue design codes, they guide to classify welding joints with their shape( BS7608, IIW Documents) and provide fatigue assessment information. In terms of numerical method for fatigue analysis, it is also difficult to decide the stress peak in joint because of mesh sensitivity which means that stress value is varies with element type or size on stress concentration zone. Hot-spot method is used generally, but Battelle of United States proposed Master S-N Curve based on structural stresses converted by mechanical equilibrium theory. In this research, we extracted master S-N curve from Battelle's fatigue test DB including test data of various welding joints to apply on Non-Load-Carrying cruciform Joint. Comparing fatigue results between the case of using normal stress and case of structural stress cor the cruciform Joint, The suggested Battelle method showed successive results.

Seamless and Secure Mobility Management with Location-Aware Service (LAS) Broker for Future Mobile Interworking Networks

  • Lee Minsoo;Kim Gwanyeon;Park Sehyun
    • Journal of Communications and Networks
    • /
    • 제7권2호
    • /
    • pp.207-221
    • /
    • 2005
  • The proliferation of wireless local area networks (WLANs) offering high data rate in hot spot area have spurred the demand for possible WLANs and third-generation (3G) cellular network integration solutions as the initiative step towards 4G systems. This paper provides a novel architecture for seamless location-aware integration of WLANs into 3G cellular networks and also an analysis for the efficient handover techniques. We introduce location as a key context in secure roaming mechanism for context-aware interworking in 4G systems. The fast secure roaming with location-aware authentication is implemented at an entity called location-aware service (LAS) broker that utilizes the concepts of direction of user and pre-warming zone. The location-ware interworking architecture supports seamless roaming services among heterogeneous wireless networks including WLANs, wireless metropolitan area networks (WMANs), and 3G cellular networks. This paper also includes a description of procedures needed to implement efficient mobility and location management. We show how the LAS broker with pre-warming and context transfer can obtain significant lower latency in the vertical handover.

50 kVA 주상용 몰드변압기의 설계 및 특성평가 (The Design and Performance Test of Mold Transformer for Outdoor Pole)

  • 조한구;이운용;황보국
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.132-137
    • /
    • 2002
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. The life of transformer is significantly dependent on the thermal behavior in windings. To analyse winding temperature rise, many transformer designer have calculated temperature distribution and hot spot point by finite element method(FEM). Recently, numerical analyses of transformer are studied for optimum design, that is electric field analysis, magnetic field, potential vibration, thermal distribution and thermal stress. In this paper, the temperature distribution of 50 kVA pole mold transformer for power distribution are investigated by FEM program and the temperature rise test of designed mold transformer carried out and test result is analyzed compare to simulation data. In this result, the designed mold transformer is satisfied to limit value of temperature and the other property is good such as voltage ratio, winding resistance, no-load loss, load loss, impedance voltage and percent regulation.

  • PDF

Evaluation of Pathogenic Variability Based on Leaf Blotch Disease Development Components of Bipolaris sorokiniana in Triticum aestivum and Agroclimatic Origin

  • Sultana, Sabiha;Adhikary, Sanjoy Kumar;Islam, Md. Monirul;Rahman, Sorder Mohammad Mahbubur
    • The Plant Pathology Journal
    • /
    • 제34권2호
    • /
    • pp.93-103
    • /
    • 2018
  • Leaf blotch of wheat caused by Bipolaris sorokiniana is a major constraint to wheat production, causing significant yield reduction resulting in severe economic impact. The present study characterizes to determine and compare pathogenic variability exist/not based on components of leaf blotch disease development and level of aggressiveness due to agroclimatic condition of B. sorokiniana in wheat. A total of 169 virulent isolates of B. sorokiniana isolated from spot blotch infected leaf from different wheat growing agroclimate of Bangladesh. Pathogenic variability was investigated on a susceptible wheat variety 'kanchan' now in Bangladesh. A clear evidence of positive relationship among the components was recorded. From hierarchical cluster analysis five groups were originating among the isolates. It resolved that a large amount of pathogenic diversity exists in Bipolaris sorokiniana. Variation in aggressiveness was found among the isolates from different wheat growing areas. Most virulent isolates BS 24 and BS 33 belonging to High Ganges River Flood Plain agro-climatic zones considered by rice-wheat cropping pattern, hot and humid weather, high land and low organic matter content in soil. Positive relationship was found between pathogenic variability and aggressiveness with agro-climatic condition.

Structural stree를 이용한 피로실험 data 분석 (Data analysis for fatigue test of welded joint using structural stress)

  • 박형진;김유일;강중규;허주호
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2005년도 추계학술발표대회 개요집
    • /
    • pp.82-84
    • /
    • 2005
  • Fatigue assessment of welded structure is very sensitive to the method of local stress determination. Normally, hot spot stress which is surface stress extracted from 0.5t, 1.5t away from weld toe is widely used to obtain local stress. However, this method has a lot of limitation in the evaluation of fatigue strength. Therefore, mesh has to comply with strict requirements since stress extracted from this method strongly rely on mesh size and element types. And that method does not cover the stress gradient through thickness direction since only surface stress is considered. Recently, new method to obtain local stress is proposed, which is structural stress. This method has an advantage, which is mesh intransitiveness and covering the effect of both bending and axial stress in local area. In this paper, fatigue test data for various welded joints was analyzed to review the reliability of structural stress. As a result, it is verified that S-N curve using structural stress guaranteed single master curve for various joint type and testing condition.

  • PDF

고준위 펄스방사선에 의한 전자소자 Latchup의 발생시험 및 분석 (An Experimental Analysis for a High Pulse Radiation Induced Latchup Conformation)

  • 이남호;황영관;정상훈;김종열
    • 한국정보통신학회논문지
    • /
    • 제18권12호
    • /
    • pp.3079-3084
    • /
    • 2014
  • 펄스 방사선에 의해 전자소자가 받는 영향으로는 Upset, Latchup, Burnout 등이 있다. 이 가운데 Latchup은 대상 소자에 회복 불가능한 영구손상(Permanent Damage)을 가져오게 되며 Burnout으로도 이어져 장비전체에 치명적 기능마비를 유발하기도 한다. 본 연구에서는 전자소자의 내부 공정설계 및 구조정보 활용이 불가능한 상황에서 실험을 통해서 펄스 방사선에 의한 Latchup 발생을 분석하고자 시도하였다. 소자를 전자빔변환 고준위 펄스 감마선 조사한 직후 수행한 전원제공 회로의 차단, 적외선 카메라의 열원측정, 그리고 손상발생 소자의 내부 회로분석의 세 단계별 확인과정은 펄스 방사선에 의해 유발된 Latchup임을 검증하는 효율적 방안으로 여겨진다.