• 제목/요약/키워드: Hot-Cold

검색결과 1,451건 처리시간 0.023초

열간 단조 공정의 금형 수명 평가 (Evaluation of die life during hot forging process)

  • 이현철;박태준;고대철;김병민
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.1051-1055
    • /
    • 1997
  • Hot forging is widely used in the manufacturing of automotive component. The mechanical, thermal load and thermal softening which is happened by the high temperature die in hot forging. Tool life of hot forging decreases considerably due to the softening of the surface layer of a tool caused by a high thermal load and long contact time between the tool and workpieces. The service life of tools in hot forging process is to a large extent limited by wear, heat crack, plastic deformation. These are one of the main factors affecting die accuracy and tool life. It is desired to predict tool life by developing life prediction method by FE-simulation. Lots of researches have been done into the life prediction of cold forming die, and the results of those researches were trustworthy, but there have been little applications of hot forming die. That is because hot forming process has many factors influencing tool life, and there was not accurate in-process data. In this research, life prediction of hot forming die by wear analysis and plastic deformation has been carried out. To predict tool life, by experiment of tempering of die, tempering curve was obtained and hardness express a function of main tempering curve.

  • PDF

Study on the global distribution of far-ultraviolet emission in our Galaxy

  • Jo, Young-Soo;Seon, Kwang-Il;Min, Kyoung-Wook;Edelstein, Jerry
    • 천문학회보
    • /
    • 제40권2호
    • /
    • pp.52.1-52.1
    • /
    • 2015
  • FIMS/SPEAR is a dual-channel far-ultraviolet imaging spectrograph on board the Korean microsatellite STSAT-1, which was launched on 2003 September 27. The primary mission goal of FIMS was to conduct a survey of diffuse far UV emissions in our Galaxy. For this purpose, FIMS completed a survey of about 84% of the sky during its operation of a year and a half. The present study aims to analyze this survey data made in the far UV wavelengths to understand the global evolution of our Galaxy. The far UV wavelength band is known to contain important cooling lines of hot gas: hence, the study will show how the hot gas in our Galaxy, produced by stellar winds and supernova explosion, evolves globally to cool down and become mixed with ambient cooler medium. One of the main findings from previous analyses of the FIMS data is that molecular hydrogen exists ubiquitously in our Galaxy. This discovery leads to another important scientific question: how is molecular hydrogen distributed in our Galaxy and how does it affect globally the evolution of our Galaxy as a cold component? Hence, the present study will cover both the hot and cold components of the ISM, which will also provide the opportunity to investigate the interactions between the two.

  • PDF

1kW급 고체산화물 연료전지 발전시스템 자열운전 (Self-sustainable Operation of a 1kW class SOFC System)

  • 이태희;최진혁;박태성;유영성
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.57-60
    • /
    • 2008
  • KEPRI has studied planar type SOFC stacks using anode-supported single cells and kW class co-generation systems for residential power generation. A 1kW class SOFC system consisted of a hot box part, a cold BOP part and a water reservoir. A hot box part contains a SOFC stack made up of 48 single cells and ferritic stainless steel interconnectors, a fuel reformer, a catalytic combustor and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation. A cold BOP part was composed of blowers, pumps, a water trap and system control units. When a 1kW class SOFC system was operated at $750^{\circ}C$ with hydrogen after pre-treatment process, the stack power was 1.2kW at 30 A and 1.6kW at 50A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about 1.3kW with hydrogen and 1.2kW with city gas respectively. The system also recuperated heat of about 1.1kW by making hot water.

  • PDF

온수를 이용한 열전발전기에서 유량변화에 따른 발전 특성 (Characteristic of Electric Generation for the Water Flow Rate in Thermoelctric Generator Using Hot Water)

  • 우병철;이희웅;서창민
    • 대한기계학회논문집B
    • /
    • 제26권10호
    • /
    • pp.1333-1340
    • /
    • 2002
  • The objective of this study is to develop a thermoelectric generation system which converts unused energy from close-at-hand sources such as garbage incineration heat and industrial exhaust etc. into electricity. This paper presents applicability of a commercially available thermoelectric generator f3r waster heat recovery. The test facility consists of water heater, pump, thermoelectric module and aluminium tubes and hot and cold water is used as heat source and sink fluids. It is shown that the three components of thermoelectric research exist in manufacturing a thermoelectric generator. The first component is fabrication of thermoelectric materials, the second is manufacturing of thermoelectric generator with 32 thermoelectric modules. The last one is characteristic measuring of thermoelectric generator with 32 thermoelectric modules of two types, cooling and power purpose. It was found that the rate of cold and hot water is 25 and 37 liter per minute and the maximum power of thermoelectric generator is 28Watts and its efficiency is 1.04%.

대향류형 보텍스 튜브의 노즐형상 변화011 따른 튜브 내부의 온도분포에 관한 실험적 연구 (An Experimental Study on the Characteristics of Temperature Distribution in Internal Space of a Tube for the Formal Change of Counterflow Type Vortex Tube)

  • 황승식
    • 한국자동차공학회논문집
    • /
    • 제10권4호
    • /
    • pp.69-76
    • /
    • 2002
  • The aim of this study is to provide fundamental informations that make it possible to use a cool stream and a hot stream simultaneously. We changed the pressure of compressed air that flows into a tube, the inner diameter of orifice that a cold stream exits, and the mass flow rate ratio. And in each case, we measured the temperature of a cold stream and a hot stream in each exit of a tube. Also we measured the axial and the radial temperature distribution in internal spare of a tube. From the study, fellowing conclusive remarks 7an be made. First, As the number of nozzles increase, separation point move into the hot exit. Second, When we use guide vane type nozzle, the axial temperature distribution constant over the 0.75 of air mass flow rate radio. Third, When we use Spiral type nozzle, axial and radial temperature distribution in the inner space is higher than another nozzle. Fourth, Axial and radial temperature distribution in the inner space vortex-tube is determined by separation point. And separation point is moved by changing of air mass flow rate ratio. At last, A heating apparatus is possible far vortex-tube to use.

액상 연료 용 $kW_e$급 SOFC 시스템 사전 연구 및 개발 (Preliminary study and development of $kW_e$-class liquid fuel based SOFC system)

  • 윤상호;김선영;배중면;백승환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.21-24
    • /
    • 2008
  • We have developed a $kW_e$ class liquid fuel based solid oxide fuel cell (SOFC) system. Our final target is to develop the 1 $kW_e$ diesel based SOFC system for residential power generator(RPG). In this study, we present the conceptual design of SOFC system. System is composed of hot-box and cold-box. Planar typed SOFC stack, heat exchanger, combustor for stack tail gas, and fuel processor, such as fuel reformer and desulfurizer, are contained in the hot-box. And several balance of plants(BOP), such as fuel suppliers and controller, are contained in the cold-box. Before the SOFC system fabrication, we have already operated the selfsustaining fuel processor, and heat exchange of all heat-related components is simulated using ASPEN HYSYS, because heat maintenance and management in hot-box are important for stable operation of SOFC system. The self-sustained fuel processor was successfully operated for about 250 hours, and heat exchange is enough to operate the SOFC system.

  • PDF

A Novel Memory Hierarchy for Flash Memory Based Storage Systems

  • Yim, Keno-Soo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제5권4호
    • /
    • pp.262-269
    • /
    • 2005
  • Semiconductor scientists and engineers ideally desire the faster but the cheaper non-volatile memory devices. In practice, no single device satisfies this desire because a faster device is expensive and a cheaper is slow. Therefore, in this paper, we use heterogeneous non-volatile memories and construct an efficient hierarchy for them. First, a small RAM device (e.g., MRAM, FRAM, and PRAM) is used as a write buffer of flash memory devices. Since the buffer is faster and does not have an erase operation, write can be done quickly in the buffer, making the write latency short. Also, if a write is requested to a data stored in the buffer, the write is directly processed in the buffer, reducing one write operation to flash storages. Second, we use many types of flash memories (e.g., SLC and MLC flash memories) in order to reduce the overall storage cost. Specifically, write requests are classified into two types, hot and cold, where hot data is vulnerable to be modified in the near future. Only hot data is stored in the faster SLC flash, while the cold is kept in slower MLC flash or NOR flash. The evaluation results show that the proposed hierarchy is effective at improving the access time of flash memory storages in a cost-effective manner thanks to the locality in memory accesses.

2 모듈 스택을 이용한 SOFC 시스템 운전결과 (Operation Results of the SOFC System Using 2 Sub-Module Stacks)

  • 이태희
    • 한국수소및신에너지학회논문집
    • /
    • 제21권5호
    • /
    • pp.405-411
    • /
    • 2010
  • A 5kW class SOFC cogeneration system consisted of a hot box part, a cold BOP (balance of plant) part, and a hot water reservoir. The hot box part contained a stack, a fuel reformer, a catalytic combustor, and heat exchangers. A cold BOP part was composed of blowers, pumps, a water trap, and system control units. A 5kW stack was designed to integrate 2 sub-modules. In this paper, the 5kW class SOFC system was operated using 2 short stacks connected in parallel to test the sub-module and the system. A short stack had 15 cells with $15{\times}15 cm^2$ area. When a natural gas was used, the total power was about 1.38 kW at 120A. Because the sub-modules were connected in parallel and current was loaded using a DC load, voltages of sub-modules were same and the currents were distributed according to the resistance of sub-modules. The voltage of the first stack was 11.46 V at 61A and the voltage of the second stack was 11.49V at 59A.

고온유동 조건의 분출냉각 실험을 위한 시험장치의 설계 및 해석 (Design and Analysis of Test Facility for the Experiment of Transpiration Cooling in Hot-flow Condition)

  • 이정민;나재정;강경택;권민찬;황기영
    • 한국추진공학회지
    • /
    • 제17권2호
    • /
    • pp.46-56
    • /
    • 2013
  • 고온 공기 공급시스템이 있는 시험장치는 분출냉각 소재를 개발하고 이를 실험적으로 평가하는데 필요한 장치이다. 본 연구에서 아크-플라즈마 발생기, 찬 공기가 공급되는 Plenum 챔버, 시험부로 구성된 시험장치를 설계하였으며, 내부 유동해석을 수행하였다. CFD 결과로부터 설계된 Plenum 챔버가 열적으로 안전하고 챔버 내부에서 초고온의 공기와 찬 공기가 잘 혼합되고 있음을 확인할 수 있었다. 또한, 시험부로 균질한 유동을 공급할 수 있는 구조로 시험장치가 설계되었음을 검증하였다.

형상기억복합재료의 저조공정 및 신뢰성 평가 (Fabrication Process and Reliability Evaluation of Shape Memory Alloy Composite)

  • 이진경;박영철;이규창;최일국;이준현
    • 비파괴검사학회지
    • /
    • 제21권6호
    • /
    • pp.634-641
    • /
    • 2001
  • 형상기억복합재료는 복합재료내에 압축잔류응력을 발생시킴으로써 재료의 인장강도를 증가시키는데 사용되어 지고 있다. 본 연구에서는 형상기억복합재료를 제조하기 위하여 TiNi 강화재와 A16061 기지재를 사용하였으며 핫프레스 방법에 의해 TiNi/A16061 형상기억복합재료를 제조하였다. 그러나 핫 프레스 방법에 의해 제조된 형상기억복합재료는 하중을 받을 시 강화재와 기지재 사이에 계면손상현상이 발생하였으며 이를 위하여 내간압연을 실시하였다. 냉간압연을 받은 시험편은 냉간압연을 받지 않은 시험편에 비하여 인장강도가 현저히 증가하였다. 또한 본 연구에서는 고온에서 형상기억복합재료의 미시적 손상을 평가하기 위하여 음향방출기법을 이용하였다.

  • PDF