• 제목/요약/키워드: Hot wire anemometer

검색결과 172건 처리시간 0.022초

열선 유속계에 대한 유체 온도의 보정 (The Correction of Fluid Temperature for Hot-wire Anemometer)

  • 심상학
    • 한국생산제조학회지
    • /
    • 제8권6호
    • /
    • pp.92-97
    • /
    • 1999
  • This paper reports by simple method that is quickly corrected the effects of fluid temperature for the hot wire anemometer. We are concerned with a variable output of hot wire anemometer on arbitrary fluid temperature. Hot wire by measuring boundary layer of turbulent flow has been calibrated by arbitrary temperature lower than 10$0^{\circ}C$, and velocity lower than 20m/s. As a result, we could pick up the temperature factor affected by output of hot wire anemometer from related in output of arbitrary temperature to output of room temperature. By using temperature factor on the output of hot wire anemometer, we also obtained that the relationship of velocity was of no effect by temperature of fluids. About results of calibrated hot wire, uncertainly of velocity is 2.15% at room temperature and 3.1% at arbitrary temperature.

  • PDF

유속에 따른 열선의 과열비 조정을 통한 열선유속계의 감도향상에 관한 연구 (Sensitivity Enhancement of a Hot-Wire Anemometer by Changing Overheat Ratio with Velocity)

  • 이신표;고상근
    • 대한기계학회논문집
    • /
    • 제19권10호
    • /
    • pp.2678-2689
    • /
    • 1995
  • In this study, a new hot-wire anemometer which has greater sensitivity than that of a constant temperature anemometer (CTA) was proposed. In contrast to CTA, the wire working resistance of the new anemometer increases with flow velocity, that is, the operating mode of the wire becomes variable temperature. The variable temperature anemometer(VTA) was made by substituting a voltage controlled variable resistor such as photoconductive cell or transistor for one of the resistors in the bridge. By positively feeding back the bridge top signal to the input side of these electronic components, the wire overheat ratio could be increased with velocity automatically. Static response analyses of the VTA, constant voltage anemometer (CVA) and CTA were made in detail and calibration experiments were performed to validate the proposed operating principle. The wire operating resistance of the CVA decreases with velocity and this leads to lower sensitivity than that of a CTA. But the sensitivity of the newly proposed VTA is superior to that of a CTA, since the wire overheat ratio increases with velocity. Consequently, it is found that the major factor that is responsible for large sensitivity of a VTA is not the working resistance itself but the change of the wire working resistance with velocity.

광도전성저항을 이용한 열선유속계의 하드웨어적 온도보상에 관한 연구 (Hardware temperature compensation technique for hot-wire anemometer by using photoconductive cell)

  • 이신표;고상근
    • 대한기계학회논문집B
    • /
    • 제20권11호
    • /
    • pp.3666-3675
    • /
    • 1996
  • A new hardware temperature compensation method for hot-wire anemometer is investigated and an analog compensating circuit is proposed in this article. A photoconductive cell is introduced here as a variable resistor in the anemometer bridge and the linearized output of a thermistor is used to monitor the input of the photoconductive cell. In contrast with the conventional method, any type of temperature sensor can be used for compensation if once the output of thermometer varies linearly with temperature. So the present technique can diversify the compensating means from a conventional passive compensating resistance to currently available thermometers. Because the resistance of a photoconductive cell can be set precisely by adopting a stabilizing circuit whose operation is based on the integration function of the operational amplifier, the accuracy of compensation can be enhanced. As an example of linearized thermometer, thermistor sensor whose output is linearized by a series resistor was used to monitor the fluid temperature variation. Validation experiment is conducted in the temperature ranged from 30 deg. C to 60 deg. C and the velocity up to 40 m/s. It is found that the present technique can be adopted as a compensating circuit for anemometer and hot-wire type airflow meter.

熱線流速計의 試作硏究 (Constriction of a hot-wire anemometer)

  • 이규한
    • 대한기계학회논문집
    • /
    • 제10권5호
    • /
    • pp.779-786
    • /
    • 1986
  • 본 연구에서는 난해한 수식을 구사한 새로운 제어회로에 관한 해석이나 설계 이론에 관한 것이 아니라 지금먼저 비금속 윅을 단독으로만 실험하여 해석해와의 일치 까지의 여러 연구자의 의론에 의하여 확립된 열선유속계의 기본계측이론을 충실하게 실현하는 단순화회로로 구조가 간단하고 취급이 간편하며 저렴한 가력으로 제작 할 수 있으며 성능면에서도 고가의 기성 상품에 비하여 그다지 손색이 없는 실용적인 정온도 형 열선유속계를 개발하는 것이다.

삼직교 열선유속계의 간편한 측정법 개발 (Development of Easy Measurement Method of Orthogonal Triple-Sensor Hot-Wire Anemometer)

  • 김진권;강신형
    • 대한기계학회논문집B
    • /
    • 제24권1호
    • /
    • pp.85-92
    • /
    • 2000
  • Easy measurement method of orthogonal triple-sensor hot-wire anemometer is developed. Advantages of the new method is that it does not require either the exact orthogonality of the installed wires which cannot be kept during the probe manufacture and repair, nor the knowledge of the wire installation angles and the yaw and pitch coefficient of the wires. The new method introduced yaw and pitch calibration coefficients which are designed to increase monotonically with yaw and pitch angles. So the resulting calibration network is simple to recognize compared with that of the previously suggested calibration method. Verification experiments showed good accuracy and independency of the directional calibration on velocity.

광도전성저항을 이용한 열선유속계의 온도보상 (Temperature Compensation of Hot-Wire Anemometer with Photoconductive Cell)

  • 이신표;고상근
    • 대한기계학회논문집B
    • /
    • 제20권1호
    • /
    • pp.295-303
    • /
    • 1996
  • A new temperature compensation technique for hot-wire anemometer is proposed in this article. In contrast to the available compensation techniques, a photoconductive cell is introduced here as a variable resistor in the bridge. The major advantage of adopting an active component such as photoconductive cell is that temperature compensation can be achieved by using any kind of temperature sensors, once the output of temperature sensor is given as a voltage. Thereby, the temperature compensation can be made automatically and intelligently by a computer software or a hardware device. Validation experiments using a photoconductive cell with a thermocouple-thermometer are conducted in the temperature range from 3$0^{\circ}C$ to 5$0^{\circ}C$ and the velocity ranges from 8 m/s to 18 m/s.

열선유개계에 의한 180$^{\circ}$곡관을 갖는 정사각 단면의 덕트에서의 난유유동특성의 측정 (Measurement of turbulent flow characteristics of a square duct with a 180.deg. bend by hot wire anemometer)

  • 양승효;최영돈;유석재
    • 대한기계학회논문집
    • /
    • 제12권4호
    • /
    • pp.900-915
    • /
    • 1988
  • 본 연구에서는 주유동 방향이 알려진 3차원 난류유동에서 열선유속계의 경사 형 프로브와 Ⅰ형 프로브를 회전시키므로써 3방향 속도성분과 6방향 레이놀즈 응력을 비교적 간편하고 정확히 측정하는 방법을 고안하여 사용하였다.

온도보상을 고려한 열선형 공기유량 측정시스템에 관한 실험적 연구 (Experimental study on hot-wire type air flow rate measurement system considering ambient temperature compensations)

  • 이민형;유정열;김사랑;고상근;윤준원;김동성
    • 오토저널
    • /
    • 제13권4호
    • /
    • pp.62-75
    • /
    • 1991
  • The purpose of this study is to perform modelings and experiments to measure air flow rate using hot-wires and a CTA(Constant Temperature Anemometer). The flow rate can be obtained by measuring the heat loss of the hot-wire due to the variations of flow velocity when the hot-wire is maintained at uniform temperature. But the defect of this method is that the output signal changes not only by the flow rate but also by the ambient temperature. Thus, in the present study, a method which compensates the variations of the ambient temperature has been introduced to measure exact flow rate. To be more specific, the bridge circuit of the usual hot-wire anemometer system has been modified in such a way that a temperature resistance sensor and a variable resistance are placed in one of the legs to compensate the different temperature coefficients of both the hot-wire and the temperature compensating resistance for flow velocity or for flow mass up to the flow temperature of 50 .deg.C. Comparing the modeling and experimental results, it has been shown that the compensating point differs as the flow rate varies. Therefore, optimum compensation points are sought to construct the circuit. The present modeling and experimental results may be applied to the design of actual air flow meters for automobiles.

  • PDF

회전하는 정사각단면 $90^{\circ}$ 곡덕트 내 내향 난류유동 측정 (Measurement of Inward Turbulent Flows in a Rotating with Square Cross-Section $90^{\circ}$ Duct)

  • 김동철;전건호;최영돈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.627-632
    • /
    • 2000
  • Developing turbulent flows in a rotating 90 degree bend with square cross-section were measured by a hot-wire anemometer. The six orientation hot-wire technique was applied to measured the distributions of 3 mean velocities and 6 Reynolds stress components. Effects of Coriolis and centrifugal forces caused by the curvature and rotation of bend on the mean motion and turbulence structures were experimentally investigated Productive addition of Coriolis and centrifugal forces to the outward radial direction in the entrance region of bend increases the secondary flow intensity according to the rotational speeds. However, after 45 degree of bend, centrifugal force due to the rotation of bend may promote the break down of counter rotating vortex pair into multi-cellular pattern, thereby decreasing the production rate of turbulence energy and Reynolds stresses.

  • PDF

열선 유속계를 이용한 3차원 유동의 계측 방법 (A method for measuring the three-dimensional flows by the hot-wire anemometers)

  • 강신형;유정열;백세진;이승배
    • 대한기계학회논문집
    • /
    • 제11권5호
    • /
    • pp.746-754
    • /
    • 1987
  • 본 연구에서는 X형 프로우브에 Mojolla의 방법을 적용하였으며, 경사프로우브 에는 프로우브의 경사각도와 회전각도에 따른 속도성분과 출력전압과의 관계를 유도하 여 적용하였으며, 이들 방법에 의한 3차원 유동계측의 정확성과 적용법위를 조사하였 다.