• Title/Summary/Keyword: Hot environments

Search Result 185, Processing Time 0.021 seconds

Corrosion Mechanism and Bond-Strength Study on Galvanized Steel in Concrete Environment

  • Kouril, M.;Pokorny, P.;Stoulil, J.
    • Corrosion Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.69-75
    • /
    • 2017
  • Zinc coating on carbon steels give the higher corrosion resistance in chloride containing environments and in carbonated concrete. However, hydrogen evolution accompanies the corrosion of zinc in the initial activity in fresh concrete, which can lead to the formation of a porous structure at the reinforcement -concrete interface, which can potentially reduce the bond-strength of the reinforcement with concrete. The present study examines the mechanism of the corrosion of hot-dip galvanized steel in detail, as in the model pore solutions and real concrete. Calcium ion plays an important role in the corrosion mechanism, as it prevents the formation of passive layers on zinc at an elevated alkalinity. The corrosion rate of galvanized steel decreases in accordance with the exposure time; however, the reason for this is not the zinc transition into passivity, but the consumption of the less corrosion-resistant phases of hot-dip galvanizing in the concrete environment. The results on the electrochemical tests have been confirmed by the bond-strength test for the reinforcement of concrete and by evaluating the porosity of the cement adjacent to the reinforcement.

Perspectives on the Hot Components for Rocket Nozzle and Thrusters (고성능 로켓노즐 및 추력기용 내열부품 현황)

  • Lim, Seong-Taek;Kim, Jung-Keun;Kang, Yun-Koo;Kim, Hyeong-Won;Kim, Yeon-Chul
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.67-71
    • /
    • 2008
  • Rocket nozzle components and thrusters for next-generation solid rocket with variable thrust, and small uncooled liquid rocket thrusters are required to withstand ultra-high temperature upto $2500^{\circ}C$. In this survey, the operationg environments are investigated with the suggeations of proper materials and their fabrication methods. Especially, It is suggested that Rhenium and other competative matrials are exploited to $2500^{\circ}C$ hot components, and thus needed to be developed.

  • PDF

New Corrosion-Resistant Zn-Al-Mg Alloy Hot-Dip Galvanized Steel Sheet

  • Kohei Tokuda;Yasuto Goto;Mamoru Saito;Hiroshi Takebayashi;Takeshi Konishi;Yuto Fukuda;Fumiaki Nakamura;Koji Kawanishi;Kohei Ueda;Hidetoshi Shindo
    • Corrosion Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.121-130
    • /
    • 2024
  • In recent years, Zn-Al-Mg alloy galvanized steel sheets have been widely used as coated steel sheets to support social capital in the infrastructure field. A feature of Zn-Al-Mg alloy-coated steel sheets is that they provide a better corrosion protection period than Zn-coated steel sheets. In this study, the corrosion resistance of a new Zn-Al-Mg alloy-coated steel sheet was investigated and compared to that of conventional commercially available coated steel sheets. The investigation confirmed that increasing the Mg concentration in the Zn-Al-Mg-coated steel sheet improved corrosion resistance, which was more than 10 times that of the galvanized steel sheet specified in JIS G 3302. The study findings also confirmed that the corrosion resistance reached more than twice that of the coated steel sheet specified in JIS G 3323. If such galvanized steel sheets are applied to social infrastructures that are exposed to severely corrosive environments, the service life of the infrastructure might be extended.

Characteristics of Hot-Dip Znmgal Coatings with Ultra-High Corrosion Resistance

  • Sungjoo Kim;Seulgi So;Jongwon Park;Taechul Kim;Sangtae Han;Suwon Park;Heung-yun Kim;Myungsoo Kim;Doojin Paik
    • Corrosion Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.289-295
    • /
    • 2024
  • Zn-Mg-Al alloy hot-dip galvanized steel sheet has high corrosion resistance. Compared to conventional Zn coating with the same coating thickness, the high corrosion resistance Zn-Mg-Al coating is more corrosion-resistant. Various coating compositions are commercially produced and applied in diverse fields. However, these steel sheets typically contain up to 3 wt% magnesium. In recent years, there has been a growing demand for higher corrosion resistance in harsh corrosive environments. Therefore, variations in Mg and Al contents were investigated while evaluating primary properties and performance. As a result, we developed new alloy-coated steel with ultra-high corrosion resistance. A Zn-5 wt%Mg-Al coated steel sheet was evaluated for its corrosion resistance and various properties. As the amount of Mg added increased, the corrosion loss tended to decrease. The corrosion resistance of the coated steel sheet in a particular composition, the Zn-5 wt%Mg-Al coating sheet, was about 1.5 to 2 times higher than that of the conventional Zn-3 wt%Mg-Al coating sheet. Ultimately, this ultra-high corrosion-resistance coated steel sheet will provide a robust solution to conserve Zn resources and contribute to a low-carbon society.

Hot environment on reproductive performance, immunoglobulins, vitamin E, and vitamin A status in sows and their progeny under commercial husbandry

  • Amavizca-Nazar, Alejandra;Montalvo-Corral, Maricela;Gonzalez-Rios, Humberto;Pinelli-Saavedra, Araceli
    • Journal of Animal Science and Technology
    • /
    • v.61 no.6
    • /
    • pp.340-351
    • /
    • 2019
  • Hot environments can affect feed intake and lactation, and the subsequent unavailability of important micronutrients to the newborn piglet can impair piglet growth, reduce the viability of newborn piglets and limit their subsequent performance. This work addresses the effects of hot environments (summer season) upon the reproductive performance of sows during gestation and lactation as well as on the serum levels of vitamins and the concentration of immunoglobulins in their litters in comparison with the winter season. Fourteen sows were evaluated over 100 ± 2 days of gestation in each season. The temperature and humidity index (THI) was used as an indirect measure of heat stress during gestation. The reproductive performance, milk yield, and body condition of the sows were recorded. The concentrations of vitamin E and vitamin A in piglets and in sow serum, colostrum, milk and feed were determined by HPLC; immunoglobulins were assessed by an ELISA. The THI index indicated that animals were subject to heat stress only in during the summer. Although the effect was not significant, there were a lower number of piglets at birth and at weaning and the milk yield in summer compared with winter. There was no difference (p > 0.05) in the body condition of sows between seasons. Season had an effect (p < 0.05) on the vitamin A concentration of postpartum sow serum (0.29 ㎍/mL in winter vs 0.21 ㎍/mL in summer) and on the vitamin E concentration before birth (2.00 ㎍/mL in winter vs 0.90 ㎍/mL in summer). Vitamin E in milk was higher (p < 0.05) in winter than in summer (2.23 vs 1.81 ㎍/mL). Serum levels of vitamins A and E in piglets at birth were lower (p < 0.05) in winter than in summer. The concentrations of immunoglobulins (IgG and IgA) in colostrum and milk were similar between seasons (p > 0.05), but the IgA in piglet serum was higher in winter than in summer (p < 0.05). High temperatures produced heat stress in sows, which affected certain aspects of production that can be translated into economic losses for this sector.

The Effect of Various Hot Environments on Physiological Responses and Information Processing Performance Following Firefighting Activities in a Smoke-Diving Room

  • Hemmatjo, Rasoul;Motamedzade, Majid;Aliabadi, Mohsen;Kalatpour, Omid;Farhadian, Maryam
    • Safety and Health at Work
    • /
    • v.8 no.4
    • /
    • pp.386-392
    • /
    • 2017
  • Background: Fire service workers often implement multiple duties in the emergency conditions, with such duties being mostly conducted in various ambient temperatures. Methods: The aim of the current study was to assess the firefighters' physiological responses, information processing, and working memory prior to and following simulated firefighting activities in three different hot environments. Seventeen healthy male firefighters performed simulated firefighting tasks in three separate conditions, namely (1) low heat (LH; $29-31^{\circ}C$, 55-60% relative humidity), (2) moderate heat (MH; $32-34^{\circ}C$, 55-60% relative humidity), and (3) severe heat (SH; $35-37^{\circ}C$, 55-60% relative humidity). It took about 45-50 minutes for each firefighter to finish all defined firefighting activities and the paced auditory serial addition test (PASAT). Results: At the end of all the three experimental conditions, heart rate (HR) and tympanic temperature (TT) increased, while PASAT scores as a measure of information processing performance decreased relative to baseline. HR and TT were significantly higher at the end of the experiment in the SH ($159.41{\pm}4.25beats/min$; $38.22{\pm}0.10^{\circ}C$) compared with the MH ($156.59{\pm}3.77beats/min$; $38.20{\pm}0.10^{\circ}C$) and LH ($154.24{\pm}4.67beats/min$; $38.17{\pm}0.10^{\circ}C$) conditions (p < 0.05). There was no significant difference in PASAT scores between LH and MH (p > 0.05). Nonetheless, there was a measurable difference in PASAT scores between LH and SH (p < 0.05). Conclusion: These consequences demonstrate that ambient temperature is effective in raising the physiological responses following firefighting activities. It is therefore argued that further increase of ambient temperature can impact firefighters' information processing and working memory during firefighting activity.

Influences of Cathodic Protection and Coating Properties on the Corrosion Control of Metallic Structure in Extremely Acidic Fluids

  • Chang, H.Y.;Yoo, Y.R.;Jin, T.E.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.4 no.6
    • /
    • pp.242-249
    • /
    • 2005
  • A lot of parts in FGD (Flue Gas Desulfurization) systems of fossil-fuel power plants show the environments in which are highly changeable and extremely acidic corrosive medium according to time and locations, e.g. in duct works, coolers and re-heaters etc. These conditions are formed when system materials are immersed in fluid that flows on them or when exhausted gas is condensed into thin layered acidic medium to contact materials of the system walls and roofs. These environments make troublesome corrosion and air pollution problems that are occurred from the leakage of the condensed solution. To cathodically protect the metallic structures in extremely acidic fluid, the properties of the protective coatings on the metal surface were very important, and epoxy Novolac coating was applied in this work. On the base of acid immersion tests, hot sulfuric acid decreased the hardness of the coatings and reduced greatly the content of $Na_2O$, $Al_2O_3$, and $SiO_2$ among the main components of the coating. A special kind of CP(Cathodic Protection) system has been developed and tested in a real scale of the FGD facility. Applied coating for this CP system was peeled off and cracked in some parts of the facility. However, the exposed metal surface to extremely acidic fluid by the failure of the coatings was successfully protected by the new CP system.

A Study on the Urban Heat Simulation Model Incorporating the Climate Changes (기후변화가 반영된 도시 열환경 시뮬레이션 모델의 연구)

  • Kang, Jonghwa;Kim, Wansoo;Yun, Jeongim;Lee, Joosung;Kim, Seogcheol
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.5
    • /
    • pp.697-707
    • /
    • 2018
  • A fast running model comprising the climate change effects is proposed for urban heat environment simulations so as to be used in urban heat island studies and/or the urban planning practices. By combining Hot City Model, a high resolution urban temperature prediction model utilizing the Lagrangian particle tracing technique, and the numerical weather simulation data which are constructed up to year of 2100 under the climate change scenarios, an efficient model is constructed for simulating the future urban heat environments. It is applicable to whole city as well as to a small block area of an urban region, with the computation time being relatively short, requiring the practically manageable amount of the computational resources. The heat environments of the entire metropolitan Seoul area in South Korea are investigated with the aid of the model for the present time and for the future. The results showed that the urban temperature gradually increase up to a significant level in the future. The possible effects of green roofs on the buildings are also studied, and we observe that green roofs don't lower the urban temperature efficiently while making the temperature fields become more homogeneous.

Anti-Corrosion Performance and Applications of PosMAC® Steel

  • Sohn, Il-Ryoung;Kim, Tae-Chul;Ju, Gwang-Il;Kim, Myung-Soo;Kim, Jong-Sang
    • Corrosion Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.7-14
    • /
    • 2021
  • PosMAC® is a brand of Zn-Mg-Al hot-dip coated steel sheet developed by POSCO. PosMAC® can form dense surface oxides in corrosive environments, providing advanced corrosion resistance compared to traditional Zn coatings such as GI and GA. PosMAC® 3.0 is available for construction and solar energy systems in severe outdoor environments. PosMAC®1.5 has better surface quality. It is suitable for automotive and home appliances. Compared to GI and GA, PosMAC® shows significantly less weight reduction due to corrosion, even with a lower coating thickness. Thin coating of PosMAC® provides advanced quality and productivity in arc welding applications due to its less generation of Zn fume and spatters. In repeated friction tests, PosMAC® showed lower surface friction coefficient than conventional coatings such as GA, GI, and lubricant film coated GA. Industrial demand for PosMAC® steel is expected to increase in the near future due to benefits of anti-corrosion and robust application performance of PosMAC® steel.

DEVELOPING U-CITY MARKET SCENARIOS THROUGH A SCENARIO PLANNING APPROACH

  • Yong-Ho Kwon;Jae-Jun Kim;Suk-Hee Han;Jin-Sik Kim;Yoon-Sun Lee
    • International conference on construction engineering and project management
    • /
    • 2007.03a
    • /
    • pp.459-468
    • /
    • 2007
  • The u-City construction project has become a hot topic in the construction market because it seems economic value-added field for construction firms. However, construction firms don't willingly participate in the u-City construction market because environments of the future business for the u-City are very uncertain. Scenario planning is a very powerful method in managing this uncertain planning situation and is based on scenarios that help each enterprise appropriately adapt itself to its own business environments. Therefore it is based on the main principles of systems thinking and multiple futures. For the purpose of dealing with such uncertainties, this paper attempts to develop the possible market scenarios of the u-City construction market in S.Korea through a scenario planning approach. From this perspective, we considered various aspects of the u-City construction such as market demands, technology development, policy level and management environment. After considering the relevant issues, we identified the main trends and key uncertainties. Finally, we developed three coherent u-City construction market scenarios. Construction firms can use these scenarios as a basic reference for market analysis and business strategy. Therefore, this paper is able to enhance the participation of construction firms in the u-City construction market.

  • PDF