• Title/Summary/Keyword: Hot Water Supply

Search Result 202, Processing Time 0.027 seconds

Variation of Energy Consumption in Barracks through Simulation by Year of Completion

  • Choi, Doo-Sung;Jeon, Hung-Chan;Cho, Kyun-Hyong;Yoo, Jeong-Seong
    • KIEAE Journal
    • /
    • v.16 no.1
    • /
    • pp.21-28
    • /
    • 2016
  • Purpose: The purpose of this study is to analyze & suggest the variation of energy consumption consequent on thermal insulation performance strengthening from early 2000s when modernization of barracks began until the present targeting a large barracks. Method: To carry out this research, this study surveyed the standard of thermal insulation by year, which is being applied to a barracks by conducting literature search, and selected the standard model for a barracks. Also, this study analyzed energy consumption by year & region by performing simulation(ECO2)of the selected standard model. Result: As a result, it was analyzed that in case of a building which was completed in 2015, the energy consumption for air-conditioning & heating, lighting, and hot water supply over the year 2000 reduced by 11% on the average in central district, 10% on the average in southern district, and 17% on the average in Jeju, respectively.

Characteristics of Energy Consumption in an Office Building located in Seoul (사무소건물의 용도 및 측정기간에 따른 에너지 소비 특성)

  • Park Byung-Yoon;Chung Kwang-Seop
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.82-87
    • /
    • 2005
  • The purpose of this study is to suggest the characteristics and actual state of energy consumption by the analysis of energy consumption data in an office building. This study examines and analyzes daily and monthly energy consumption of an office building located in Seoul, Korea regarding type of load and business classification within a building. The results are as follows. 1) Energy consumption of office building for each type of load show similar consumption patterns, regardless of seasons such as cooling period and heating period. 2) Out of all annual energy consumption, consumption for lighting took about $43\;\%,$ general electric Power about $23\;\%,$ emergency power $25\;\%,$ computer center $5\;\%$ and cooling power $4\;\%,$ showing that the consumption for lighting was highest, and the percentage of energy consumption for cooling power for operation of cooling facilities took the lowest percentage. 3) Annual gas consumption used for heating and hot water supply were $38,\;36\;\%$ for officetel and office respectively, and $26\;\%$ for arcade. 4) Electricity consumptions used for cooling power for each use of building, office and officetel recorded in July and August of cooling seasons. Even though it shows different patterns for each month, energy consumption showed unique pattern throughout the cooling seasons.

A Study on the Application Plan of Air-Conditioning and New and Renewable Systems in the Large High Schools (대규모 고등학교의 냉난방 및 신재생에너지시스템 적용방안에 관한 연구)

  • Kim, Ji-Yeon;Park, Hyo-Soon;Kim, Seong-Sil;Suh, Seung-Jik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.10
    • /
    • pp.564-574
    • /
    • 2009
  • The study is conducted to study a new, optimum and new and renewable energy application method that can cover the minimum energy and operation costs within a range of school budgets. By deriving the optimum application method, it is expected to maximize the cooling/heating and hot water supply energy saving efficiencies for educational facilities. Therefore, this research implemented a study on the new and renewable energy utilization technique diffusion expansion method and the optimum method. As a result, the first optimum plan was introduced with the multi-type geothermal heat pump 475.6 kW+highly efficient electronic cooling/heating device(EHP) 545.2 kW. On the other hand, the second optimum plan was induced as the multi-type geothermal heat pump 261kW+solar heat collector $240\;m^2$+highly efficient electronic cooling/heating device(EHP) 759.8 kW.

Thrust Measurement System for High Altitude Simulation Test of the KSLV-I Kick Motor (KSLV-I 킥모터 개발을 위한 고공환경모사시험용 추력측정장치)

  • Lee, Jung-Ho;Cho, Sang-Yeon;Cho, Kie-Joo;Jung, Dong-Ho;Lee, Han-Ju;Oh, Seung-Hyub;Yoon, Kyung-Youl;Kim, Dong-Cheol
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.428-431
    • /
    • 2008
  • Korea Aerospace Research Institute(KARI) is achieving the Korea Space Launch Vehicle(KSLV) program according to National Space Technology Development Program. KSLV-I will be composed to liquid propellant(first stage) and solid propellant(second stage) propulsion system. The propulsion system of KSLV-I second stage is solid kick motor with high expansion ratio and its starting altitude is 300km high. In order to verify the performance of upper stage propulsion system designed to operate in the upper atmosphere, test facility which can simulate high altitude is needed. High Altitude Simulation Test Facility is composed to Thrust Measurement System, Control & Measurement system, Diffuser, SKID for cooling water supply to diffuser, CCTV, fire protection system and so on. This paper introduces TMS adapted to High Altitude Simulation Test for KSLV-I Kick Motor Development and results of hot firing test for its performance verification.

  • PDF

Study on the Impacts and Countermeasures of Climate Change on Livestock Agriculture (축산부문에 미치는 기후변화의 영향 및 대응방안 연구)

  • Ji, Eun-Sook;Park, Kyu-Hyun
    • Journal of Animal Environmental Science
    • /
    • v.21 no.2
    • /
    • pp.47-54
    • /
    • 2015
  • Climate change has directly impacted environmentally dependent first industry. The changes of amount and frequency of precipitation have caused unstable drinking water supply for grassland and feed crop, and have changed the variety of grassland and feed crop. Rising temperature has caused heat stress on livestock, which has impacted feed intake and livestock products, and also has threatened to the health of livestock by widening the range of sources of diseases. In order for livestock industry to confront climate change, new technology development for climate change adaptation and measures of greenhouse gas mitigation are essential. Agroforestry is the one of alternative measures to mitigate greenhouse gases and to adapt to climate change. Agroforestry is the way rearing livestock and cultivating plants in forest, which is suitable to Korea where mountain area is over 68%. Feedstock such as maize, soybean, rice, and grass grown by agroforestry would decrease feed cost. Agroforestry will decrease heat stress of livestock during hot weather and will be possible to pasture, which increases livestock welfare.

The Performance Test and the Feasibility Study for a Dual-Source Heat Pump System Using the Air and Ground Heat Source (공기 및 지열 이용 Dual-Source 히트펌프 시스템의 성능실험 및 경제성 분석)

  • Nam, Yujin;Chae, Ho-Byung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.212-217
    • /
    • 2014
  • Recently, the use of renewable energy has been increased due to growing concern on the energy-saving at buildings and the reduction of $CO_2$ emission. In the field of architecture, to reduce the energy consumption of heating, cooling and hot water supply, heat pump systems with renewable energy has been developed and used in various applications. However, there have been many of researches on the large-scale commercial heat pump systems, but the research and the field application of a compact heat pump system is rare. Therefore, in order to develop the compact heat pump for the small-scale residential building, this study conducted the performance test and feasibility study for a hybrid heat pump using the heat source of air, solar and ground. In the results of experiments through a trial product, the average COP of cooling mode with ground heat source was 4.75, and it of heating mode was 4.03. Furthermore, the average COP of cooling mode with air heat source was 2.60, and it of heating mode was 2.92. Finally, payback period of the system was calculated as 9.2 years.

The feasibility study for the building integrated geothermal system using the horizontal heat exchanger (수평형 지중열교환기를 이용한 건물일체형 지열시스템의 도입타당성 분석)

  • Chae, Ho-Byung;Nam, Yujin;Yoon, Sung-Hoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.1
    • /
    • pp.81-87
    • /
    • 2015
  • Recently, in order to prevent increasing energy usages in the international community, many countries have attempted to develop the innovative renewable energy systems. Among the renewable energy systems, Ground source heat pump(GSHP) system which supply the heating, cooling and hot water in the building has been attracted by its stability of heat production and high efficiency. However, the initial drilling costs become very expensive and the construction period takes longer the other systems, because GSHP system needs more than 100 m depth drilling. In this study, in order to reduce initial costs of the GSHP, the building integrated geothermal system using the horizontal heat exchanger was developed. The heating and cooling load in the standard housing model was calculated by a simulation and the system design capacity in the high-rise apartment was decided by the total load. Based on the system design capacity, the high-rise apartments were applied to a BIGS and vertical GSHP system and there are analyzed about initial costs. In the result, the initial cost of BIGS could reduce 24% of the initial cost of the vertical GSHP system.

A Study on the Improvement of Indoor Thermal Performance of Floor Radiant Heating System Considering Valve Operation Characteristics (바닥복사 난방시스템의 밸브구동 특성을 고려한 실내 열환경 성능 개선 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.4
    • /
    • pp.36-45
    • /
    • 2021
  • In this study, to improve the indoor thermal environment of the radiant floor heating system, a study was conducted on the temperature change characteristics and energy consumption according to the change of the indoor air set temperature, the supply hot water temperature and the outdoor temperature. As for the control method, the on/off control and the thermal difference proportional control method proposed through previous studies were applied. In addition, in consideration of field applicability, numerical analysis was performed for the case where the indoor air temperature sensor was affected by the wall temperature. As a result, it was found that the temperature difference proportional control method is more effective for thermal comfort and energy saving than on/off control.

A System Simulation Model of Proton Exchange Membrane Fuel Cell for Residential Power Generation for Thermal Management Study (가정용 연료전지 시스템의 열관리 해석을 위한 시스템 운전 모델 개발)

  • Yu, Sang-Seok;Lee, Young-Duk;Ahn, Kook-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.19-26
    • /
    • 2010
  • A PEMFC(proton exchange membrane fuel cell) is a good candidate for residential power generation to be coped with the shortage of fossil fuel and green house gas emission. The attractive benefit of the PEMFC is to produce electric power as well as hot water for home usage. The thermal management of PEMFC for RPG is to utilize the heat of PEMFC so that the PEMFC can be operated at its optimal efficiency. In this study, thermal management system of PEMFC stack is modeled to understand the dynamic response during load change. The thermal management system of PEMFC for RPGFC is composed of two cooling circuits, one for controling the fuel cell temperature and the other for heating up the water for home usage. The different operating strategy is applied for each cooling circuit considering the duty of those two circuits. Even though the capacity of PEMFC system (1kW) is enough to supply hot domestic water for residence, heat-up of reservior takes some hours. Therefore, in this study, time schedule of the simulation reflects the heat-up process. Dynamic responses and operating strategies of the PEMFC system are investigated during load changes.

Experimental Study on Consumption of Energy and Heating Efficiency in Floor Water Heating System on Using Ondol Panel of Double Metal Rendering (이중금속융출형 온돌판넬을 이용한 바닥온수난방시스템의 난방성능과 에너지소비량에 관한 실험적 연구)

  • Bai, Dai-Kwon;Kim, Jin-Bong;Kim, Hwan-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.6167-6175
    • /
    • 2012
  • This study is experimental analysis to verify heating efficiency of Ondol in floor heating panel developed. For this one, an experiment tests producing an each test speciment and measuring heating efficiency. The result of an experiment, supplying hot water temperature is $45^{\circ}C$ and the result of measuring on parts temperature of test speciment on supplying for 8 hours, mortar surface that is superstructure plumbing of heating system developed is $49.4^{\circ}C$, the gap of piping on center of mortar surface is $44.1^{\circ}C$ and airspace is proved $25.3^{\circ}C$. In floor structure of standards, mortar surface is $46.2^{\circ}C$, the gap of piping on center of mortar surface $37.7^{\circ}C$ and airspace is $24.7^{\circ}C$. On the other hand, energy consumption accumulating of development technology is identified, in case of hot-water supply on $45^{\circ}C$ as 4,646 kcal and in existing technology, as 4,814 kcal. developing technology is verified and lower than existing technology.