2 모듈 스택을 이용한 SOFC 시스템 운전결과 (Operation Results of the SOFC System Using 2 Sub-Module Stacks)

  • 이태희
    • 한국수소및신에너지학회논문집
    • /
    • 제21권5호
    • /
    • pp.405-411
    • /
    • 2010
  • A 5kW class SOFC cogeneration system consisted of a hot box part, a cold BOP (balance of plant) part, and a hot water reservoir. The hot box part contained a stack, a fuel reformer, a catalytic combustor, and heat exchangers. A cold BOP part was composed of blowers, pumps, a water trap, and system control units. A 5kW stack was designed to integrate 2 sub-modules. In this paper, the 5kW class SOFC system was operated using 2 short stacks connected in parallel to test the sub-module and the system. A short stack had 15 cells with $15{\times}15 cm^2$ area. When a natural gas was used, the total power was about 1.38 kW at 120A. Because the sub-modules were connected in parallel and current was loaded using a DC load, voltages of sub-modules were same and the currents were distributed according to the resistance of sub-modules. The voltage of the first stack was 11.46 V at 61A and the voltage of the second stack was 11.49V at 59A.

열수처리가 신선 편의가공 양파의 저장품질에 미치는 효과 (Effect of Hot Water Treatment on Storage Quality of Minimally Processed Onion)

  • 홍석인;이현희;손석민;김동만
    • 한국식품과학회지
    • /
    • 제36권2호
    • /
    • pp.239-245
    • /
    • 2004
  • 신선 편의가공 채소류의 전처리기술로서 중온처리의 적용 가능성을 확인하고자 박피 양파의 열수처리에 따른 저장중 품질특성 변화를 살펴보았다. 건조외피 제거, 절단, 수세를 거친 양파 시료에 대해 $50-80^{\circ}C$의 열수로 1 분간 침지한 후 물기를 제거하고 $63\;{\mu}m$ 두께의 LDPE 필름에 밀봉 포장하여 $10^{\circ}C$에 저장하면서 이화학, 미생물, 관능적 특성 변화를 측정하였다. 생체 중량감소 및 절단 표면색 변화는 상대적으로 고온($70,\;80^{\circ}C$) 처리구에서만 유의적인 증가를 나타내었고, 미생물의 경누 열처리 직후 고온 처리구에서 90% 이상의 생균수 감균 효과를 확인할 수 있었으나, 저장 중기 이후에는 처리구별로 유의적인 생균수 차이를 구분할 수 없이 약 $10^6-10^7\;CFU/g$ 수준을 나타내었다. 관능 평가에서는 저장 28일까지 $60^{\circ}C$ 중온 처리구가 변색, 시듦, 부패 항목에서 상대적으로 가장 낮은 점수를 나타내었고 외관 품질도 비교적 우수하여 박피 양파의 저장중 품질유지에 가장 유리한 열수 처리온도임을 확인할 수 있었다.

삼중효용 LiBr/물 흡수식 냉방기의 사이클 시뮬레이션 (Cycle simulation of a triple effect LiBr/water absorption chiller)

  • 조광운;정시영;정은수
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.79-87
    • /
    • 1998
  • Basic design of a 50USRT(175㎾) triple effect absorption chiller driven by hot gas has been carried out for both parallel and series flow cycles. Parallel flow cycle showed higher COP, however, the temperature in the generator was also higher than that in series flow cycle. Dynamic operation behavior of a parallel flow system at off-design conditions, such as the change in heat transfer medium temperature or the construction change of the system components, has been investigated in detail. It was found that the cooling capacity was seriously decreased by reducing hot gas flow rate and UA-value in the high temperature generator. However, the system COP was improved, because thermal load in the system components was reduced. The COP and the cooling capacity was found to be improved as cooling water temperature decreased or chilled water temperature increased. The optimum ratio of solution distribution could be suggested by considering the COP, the cooling capacity and the highest temperature in the system, which is critical for corrosion.

  • PDF

벽체일체형 자연순환 태양열온수기의 동적거동과 열성능에 관한 실증연구 (An Empirical Study on the Thermal Performance and Dynamic Behavior of Wall Integrated Thermosiphon Solar Water Heater)

  • 백남춘;김성범;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제36권6호
    • /
    • pp.25-35
    • /
    • 2016
  • In this study, the evaluation of the dynamic behavior and thermal performance of the "Façade integrated Natural circulation Solar Water Heating System" installed in the residential house was carried out. Experimental tests were performed during the all year around in the rural houses of $166m^2$ in size. Facade integrated solar collector of $5m^2$ were installed on the south-facing. Electrical heater of 1 kW capacity as an auxiliary heater was installed at the upper part of the heat storage tank. The analyzing results are as follows. (1) Monthly average solar fraction was 51 to 87% and yearly average value is 64%. (2) Hot water supply temperature in December which has the lowest solar altitude is 37 to $76^{\circ}C$. The highest working fluid temperature of solar collector in this period was below $84^{\circ}C$. The temperature difference of working fluid between the collector inlet and outlet has been shown to be around 9 to $26^{\circ}C$. (3) Overheating which is one of the biggest problems during summer did not appear at all, but rather had hot water supply temperature is rather low as $30{\sim}47^{\circ}C$ in summer than winter, which is supplied by a small solar load. The solar collecting temperature has been shown to maintain below $55^{\circ}C$. (5) The thermal performance of Facade integrated solar collector can be increase due to the reduction of heat loss to the back of the collector wall integration of the collector is reduced. As a conclusion, Facade integrated natural circulation type Solar Water Heating System is a well-functioning without any pumps or controllers, and it was found that the disadvantages of conventional solar water heaters, hot water or hot water system can be greatly improved.

배열 이용형 흡수식 사이클 특성평가 (Characteristics Evaluation of Absorption Cycles using the Waste Heat)

  • 윤정인;권오경;문춘근
    • 태양에너지
    • /
    • 제18권4호
    • /
    • pp.23-32
    • /
    • 1998
  • Fuel cells supply electric power and heat at work, and their exhaust gas is comparatively clear. So they are in the limelight as one of the co-generation systems which behave friendly with the environment. Fuel cells discharge both steam and hot water. Accordingly, if we combine absorption heat pump driven by waste heat with fuel cells, we can construct an advanced energy conserving system. The purpose of this study is the objective for evaluating the possibilities of effectively utilizing waste heat of fuel cells as a heat source for the single and double effect absorption systems. Simulation studies on single and double effect absorption have been performed for water/lithium-bromide pair. The effectiveness of introducing a waste heat source of fuel cells is demonstrated. The result of this study showed that total efficiency was about 85% at rated operation and about 75% at 75% load operation. Absorption cycle moved to more strong concentration when fuel cell operated at 75% load.

  • PDF

황구지천 유역의 오염부하 특성 및 지류 영향 평가 (Evaluation on Pollution Load Characteristics and Influence of Tributaries in the Hwangguji Stream)

  • 임수진;임병란;이한샘;강주형;안태웅;신현상
    • 한국물환경학회지
    • /
    • 제37권4호
    • /
    • pp.249-262
    • /
    • 2021
  • This study investigated the pollution characteristics of the main pollution zone in the Hwangguji watershed and the influence of the tributary on the main stream. The characteristics of the main pollution zone, including, the water quality index (WQI), stream rating, load duration curve (LDC), delivery load density (DLD), and contribution of the tributary to the mainstream, were evaluated by time-series visual heatmap. The WQI of the mainstream of Hwangguji was lowered to the poor (IV) level from the inflow point of Suwon stream (SW) and the LDC excess rate in the T-P was higher than that of BOD5, especially for the wet season, suggesting that management of non-point source with T-P is preferred. The contribution (%) of the tributaries in the upstream section of Hwangguji watershed were BOD5 14.54%, TOC 15.67%, T-N 5.43%, and T-P 6.97%. In particular, the Suwon sewage treatment plant located in the mainstream showed a high contribution of BOD5 (64.40%) and T-P (53.54%), respectively, due to the high discharge rate (6.019 m3/sec). Meanwhile, Sammi and Gal stream have a large impact on the mainstream with high DLD and poor WQI. Thus, both streams were considered as pollution hot spots. These results provide useful basic data for preparing more effective water quality improvement and management plans in the watershed.

부하를 고려한 태양열온수시스템의 일간 집열효율에 대한 실험적 분석 (An Experimental Study on Daily Efficiency of Solar Collector with Heating Loads of Solar Water Heating System)

  • 이경호;주홍진;윤응상;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제32권2호
    • /
    • pp.19-27
    • /
    • 2012
  • This paper describes an experimental study on efficiency of solar collector in solar water heating system connected to hourly water heating load. In general, the functional form of solar efficiency is expressed as a function of fluid temperature entering solar collector, ambient temperature, and solar irradiance. When energy saving from solar heating of water heating system is analyzed on along-term basis such as one year with given solar irradiance data, simplified analysis is more convenient han detailed system simulation for quick assessment. However, the functional form of the efficiency is not convenient for approximately simplified energy analysis because the inlet temperature can be obtained through a detailed system simulation. In the study, solar collector efficiency is obtained with various daily water heating load sand daily solar irradiance using experimental tests. The study also considers large residential buildings such as apartment buildings for application of solar water heating systems. From test results, it is found that daily solar collector efficiency is proportional to daily water heating loads and daily solar irradiance. The data obtained from the study can be utilized to find a functional relation between daily solar irradiance and daily heating load in stead of collector inlet temperature for application of solar collector efficiency to long-term approximated energy analysis of solar heating system.

수경재배 온실의 양액냉각시스템 개발 (Development of Nutrient Solution Cooling System in Hydroponic Greenhouse)

  • 남상운;김문기
    • 한국농공학회지
    • /
    • 제36권3호
    • /
    • pp.113-121
    • /
    • 1994
  • Since it is difficult to expect the normal production of plants in greenhouses during hot summer season in Korea, certain provisions on the control of extreme environmental factors in summer should be considered for the year-round cultivation in greenhouses. This study was carried out to find a method to suppress the temperature rising of nutrient solution by cooling, which is able to contribute to the improvement of the plant growth environment in hydroponic greenhouse during hot summer season. A mechanical cooling system using the counter flow type with double pipe was developed for cooling the nutrient solution efficiently. Also the heat transfer characteristics of the system was analysed experimentally and theoretically, and compared with the existing cooling systems of nutrient solution. The cooling capacities of three different Systems, which used polyethylene tube in solution tank, stainless tube in solution tank, and the counter flow type with double pipe, were evaluated. The performance of each cooling system was about 41 %, 70% and 81 % of design cooling load in hydroponic greenhouse of 1 ,000m$^2$ on the conditions that the flow rate of ground water was 2m$^3$/hr and the temperature difference between two liquids was 10 ˚C According to the results analysed as above, the cooling system was found to have a satisfactory cooling capability for regions where ground water supply is available. Fer the other regions where ground water supply is restricted, more efficient cooling System should be developed.

  • PDF

Ultrasonic Welding Technology for Solar Thermal Collector

  • Kim, Sung-Wook;Chun, Chang-Keun;Kim, Sook-Hwan
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2009년 추계학술발표대회
    • /
    • pp.221-225
    • /
    • 2009
  • A solar thermal collector is a solar collector specifically intended to collect heat: that is, to absorb sunlight to provide heat. A flat plate is the most common type of solar thermal collector, and is usually used as a solar hot water panel to generate solar hot water. A flat plate collector consists basically of an insulated metal box with a glass or a plastic cover and a dark-colored copper absorber plate. Solar radiation is absorbed by the copper absorber plate and transferred to water that circulates through the collector in copper tubes. Ultrasonic welding is an industrial technique whereby high-frequency ultrasonic acoustic vibrations are locally applied to work pieces being held together under pressure to create a solid-state weld. In this study, we developed solar collector ultrasonic welding machine with digital controlled power supply and tested various welding conditions such as welding pressure, welding amplitude, welding speed. Welding speed was considered in 2~12m/min. The width of ultrasonic welds was increased with welding amplitude by 2.2~2.5mm. The fracture load of ultrasonic welds showed 20% higher than domestic products.

  • PDF

실측데이터를 이용한 에너지제로주택의 연간 에너지성능평가 (Annual Energy Performance Evaluation of Zero Energy House Using Metering Data)

  • 임희원;윤종호;신우철
    • KIEAE Journal
    • /
    • 제16권3호
    • /
    • pp.113-119
    • /
    • 2016
  • Purpose: In this study, we evaluate the annual energy performance of the detached house which was designed with the aim of zero energy. Method: The experimental house which was constructed in Gonju Chungnam in 2013, is the single family detached house of light weight wood frame with $100m^2$ of heating area. Thermal transmittance of roof (by ISO 10211) and building external walls are designed as $0.10W/m^2K$ and $0.14W/m^2$ respectively and low-e coating vacuum window glazing with PVC frame was installed. Also grid connected PV system and natural-circulation solar water heater was applied and 6kWp capacity of photovoltaic module was installed in pitched roof and $5m^2$ of solar collector in vertical wall facing the south. We analyzed the 2014 annual data of the detached house in which residents were actually living, measured though web-based remote monitoring system. Result: First, as a result, total annual energy consumption and energy production (PV generation and solar hot water) are 7,919kWh and 7,689kWh respectively and the rate of energy independence is 97.1% which is almost close to the zero energy. Second, plug load and hot water of energy consumption by category showed the highest numbers each with 33% and 31%, with following space heating 24%, electric cooker 8%, lighting 3% in order. Hot water supply is relatively higher than space heating because high insulation makes it decreased.