• Title/Summary/Keyword: Hot Spots

Search Result 255, Processing Time 0.021 seconds

PHOTOMETRIC SOLUTIONS AND SPOT MODEL OF THE CONTACT BINARY AB ANDROMEDAE (접촉쌍성 AB Andromedae의 측광해와 흑점모델)

  • Lee, Jae-Woo;Kim, Chun-Hwey;Han, Won-yong;Jin, Ho;Oh, Kyu-Dong
    • Journal of Astronomy and Space Sciences
    • /
    • v.20 no.2
    • /
    • pp.123-132
    • /
    • 2003
  • We performed CCD photometric observations of the W-type contact binary AB And for 10 nights from November 1995 to December 1999 using the 61-cm reflector and BVR filters at Sobaeksan Optical Astronomy Observatory. From our observations, the seasonal light curves of AB And for 1995, 1996 and 1999 were completed and 8 new times of minimum light were determined. Newly obtained light curves show that strong light variations occurred in AB And during the past five years. We adopted the 1996 light curves as reference ones and obtained the photometric solutions of them with contact mode in the Wilson-Devinney binary code. Assuming such light variations were produced by the existence of a star spot (or star spots) in the analysis, we derived the system parameters and analyzed the 1995 and 1999 light curves by adjusting only the spot parameters. As the results, we interpreted that those light variations are produced by the simultaneous existence of a hot spot and a cool spot on the secondary. We could infer that the hot spot on the secondary is produced due to mass exchange between the components suggested by Lee (1999).

Dosimetric Comparison between Intensity Modulated Radiotherapy and 3 Dimensional Conformal Radiotherapy in the Treatment of Rectal Cancer

  • Simson, David K;Mitra, Swarupa;Ahlawat, Parveen;Sharma, Manoj Kumar;Yadav, Girigesh;Mishra, Manindra Bhushan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.11
    • /
    • pp.4935-4937
    • /
    • 2016
  • Objective: To compare dosimetric parameters of 3 dimensional conformal radiotherapy (3 DCRT) and intensity modulated radiotherapy (IMRT) in terms of target coverage and doses to organs at risk (OAR) in the management of rectal carcinoma. Methods: In this prospective study, conducted between August 2014 and March 2016, all patients underwent CT simulation along with a bladder protocol and target contouring according to the Radiation Therapy Oncology Group (RTOG) guidelines. Two plans were made for each patient (3 DCRT and IMRT) for comparison of target coverage and OAR. Result: A total of 43 patients were recruited into this study. While there were no significant differences in mean Planning Target Volume (PTV) D95% and mean PTV D98% between 3 DCRT and IMRT, mean PTV D2% and mean PTV D50% were significantly higher in 3 DCRT plans. Compared to IMRT, 3 DCRT resulted in significantly higher volumes of hot spots, lower volumes of cold spots, and higher doses to the entire OAR. Conclusion: This study demonstrated that IMRT achieves superior normal tissue avoidance (bladder and bowel) compared to 3 DCRT, with comparable target dose coverage.

CERAMOGRAPHY ANALYSIS OF MOX FUEL RODS AFTER AN IRRADIATION TEST

  • Kim, Han-Soo;Jong, Chang-Yong;Lee, Byung-Ho;Oh, Jae-Yong;Koo, Yang-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.42 no.5
    • /
    • pp.576-581
    • /
    • 2010
  • KAERI (Korea Atomic Energy Research Institute) fabricated MOX (Mixed Oxide) fuel pellets as a cooperation project with PSI (Paul Scherrer Institut) for an irradiation test in the Halden reactor. The MOX pellets were fitted into fuel rods that included instrumentation for measurement in IFE (Institutt for Energiteknikk). The fuel rods were assembled into the test rig and irradiated in the Halden reactor up to 50 MWd/kgHM. The irradiated fuel rods were transported to the IFE, where ceramography was carried out. The fuel rods were cut transversely at the relatively higher burn-up locations and then the radial cross sections were observed. Micrographs were analyzed using an image analysis program and grain sizes along the radial direction were measured by the linear intercept method. Radial cracks in the irradiated MOX were observed that were generally circumferentially closed at the pellet periphery and open in the hot central region. A circumferential crack was formed along the boundary between the dark central and the outer regions. The inner surface of the cladding was covered with an oxide layer. Pu-rich spots were observed in the outer region of the fuel pellets. The spots were surrounded by many small pores and contained some big pores inside. Metallic fission product precipitates were observed mainly in the central region and in the inside of the Pu spots. The average areal fractions of the metallic precipitates at the radial cross section were 0.41% for rod 6 and 0.32% for rod 3. In the periphery, pore density smaller than 2 ${\mu}m$ was higher than that of the other regions. The grain growth occurred from 10 ${\mu}m$ to 12 ${\mu}m$ in the central region of rod 6 during irradiation.

Estimation of Link-Based Traffic-Related Air Pollutant Emissions and the Exposure Intensity on Pedestrian Near Busy Streets (유동인구 밀집지역 인근의 도로구간별 배출량 산정 및 보행자 노출 강도 평가)

  • Lee, Sangeun;Shin, Myunghwan;Lee, Seokjoo;Hong, Dahee;Jang, Dongik;Keel, Jihoon;Jung, Taekho;Lee, Taewoo;Hong, Youdeog
    • Journal of ILASS-Korea
    • /
    • v.23 no.2
    • /
    • pp.81-89
    • /
    • 2018
  • The objective of this study is to estimate the level of exposure of traffic-related air pollutants (TRAPs) on the pedestrians in Seoul area. The road network's link-based pollutant emission was calculated by using a set of mobile source emission factor package and associated activity information. The population information, which is the number of pedestrian, was analyzed in conjunction with the link-based traffic emissions in order to quantify exposure level by selected 23 spots. We proposed the Exposure Intensity, which is defined by the amount of traffic emission and the population, to quantify the probability of exposure of pedestrian. Link-based traffic NOx and PM emissions vary by up to four times depending on the location of each spot. The Hot-spots is estimated to be around 1.8 times higher Exposure Intensity than the average of the 23 selected spots. The information of Exposure Intensity of each spot allows us to develop localized policies for air quality and health. Even in the same area, the Exposure Intensity over time also shows a large fluctuation, which gives suggestions for establishing site-specific counter-measures.

Operation Characteristics of Bypass Diode for PV Module (태양전지 모듈의 바이패스 다이오드 동작 특성 분석)

  • Kim, Seung-Tae;Park, Chi-Hong;Kang, Gi-Hwan;Lawrence, Waithiru C.K.;Ahn, Hyung-Keun;Yu, Gwon-Jong;Han, Deuk-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.1
    • /
    • pp.12-17
    • /
    • 2008
  • In this paper, an I-V characteristics of bypass diode has been studied by counting the shading effect in photovoltaic module. The shadow induces hot spot phenomenon in PV module due to the increase of resistance in the current path. Two different types of PV module with and without bypass diode were fabricated to expect maximum output power with an increasing shading rate of 5 % on the solar cell. Temperature distribution is also detected by shading the whole solar cell for the outdoor test. From the result, the bypass diode works properly over 60 % of shading per cell with constant output power. Maximum power generation in case of solar cell being totally shaded with bypass diode decreases 41.3 % compared with the one under STC(Standard Test Condition). On the other hand, the maximum output power of the module without bypass diode gradually decreases by showing hot spot phenomenon with the increase of shading ratio on the cell and finally indicates 95.5 % of power loss compared with the output under STC. Finally the module temperature measured increases around $10^{\circ}C$ higher than that under STC due to hot-spots which come from the condition without bypass diode. It has been therefore one of the main reasons for degrading the PV module and shortening the durability of the PV system.

Comparison of Counter-Current Cooling and Pool Boiling System Through Modeling and Simulation of a Pilot-Scale Fixed bed Reactor for Dimethyl Ether(DME) Synthesis (Dimethyl Ether(DME) 합성을 위한 파일럿 규모의 고정층 반응기의 모델링과 모사를 통한 향류 냉각방식과 포화액체 풀비등 방식의 비교)

  • Song, Daesung;Go, Jae Wook;Yoon, En Sup
    • Korean Chemical Engineering Research
    • /
    • v.47 no.4
    • /
    • pp.446-452
    • /
    • 2009
  • The behavior of a one-step fixed bed reactor which directly synthesizes dimethyl ether(DME) from Natural Gas was simulated. In the reactor, the prevention of the occurrence of hot spots which can cause deactivation of catalysts is pivotal, since methanol synthesis and dehydration reaction involved in the synthesis of DME are highly exothermic. Therefore, we simulated and compared performance of the reactor with counter-current cooling and pool boiling system that can be applied to a commercial plant. As a result, we found that counter-current cooling system is more effective in terms of CO conversion and DME productivity. However, pool boiling system can operate in a small temperature gradient that can decrease problems caused by hot spot. And, the system can operate in a safer range.

An Analysis on the Spatial Pattern of Local Safety Level Index Using Spatial Autocorrelation - Focused on Basic Local Governments, Korea (공간적 자기상관을 활용한 지역안전지수의 공간패턴 분석 - 기초지방자치단체를 중심으로)

  • Yi, Mi Sook;Yeo, Kwan Hyun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.1
    • /
    • pp.29-40
    • /
    • 2021
  • Risk factors that threaten public safety such as crime, fire, and traffic accidents have spatial characteristics. Since each region has different dangerous environments, it is necessary to analyze the spatial pattern of risk factors for each sector such as traffic accident, fire, crime, and living safety. The purpose of this study is to analyze the spatial distribution pattern of local safety level index, which act as an index that rates the safety level of each sector (traffic accident, fire, crime, living safety, suicide, and infectious disease) for basic local governments across the nation. The following analysis tools were used to analyze the spatial autocorrelation of local safety level index : Global Moran's I, Local Moran's I, and Getis-Ord's G⁎i. The result of the analysis shows that the distribution of safety level on traffic accidents, fire, and suicide tends to be more clustered spatially compared to the safety level on crime, living safety, and infectious disease. As a result of analyzing significant spatial correlations between different regions, it was found that the Seoul metropolitan areas are relatively safe compared to other cities based on the integrated index of local safety. In addition, hot spot analysis using statistical values from Getis-Ord's G⁎i derived three hot spots(Samchuck, Cheongsong-gun, and Gimje) in which safety-vulnerable areas are clustered and 15 cold spots which are clusters of areas with high safety levels. These research findings can be used as basic data when the government is making policies to improve the safety level by identifying the spatial distribution and the spatial pattern in areas with vulnerable safety levels.

A Study of a Game User Oriented Load Balancing Scheme on MMORPG (MMORPG 서버를 위한 게임 사용자 중심의 부하 분산 기법에 관한 연구)

  • Choi, Jong-Gwan;Kim, Hye-Young;Woo, Won-Sik
    • Journal of Korea Game Society
    • /
    • v.12 no.3
    • /
    • pp.69-76
    • /
    • 2012
  • At MMORPGs that has the numerous game users with many interactions at the same virtual world, massive loading that results in delays, resource shortages, and other such problems occur. To solve this, many developers devote research to load-balancing servers, yet due to steady and dynamic map divisions, such research is unreliable. This paper proposes a game user-oriented load balancing scheme for the load balancing of MMORPG servers. This scheme shows effectiveness at dealing with hot-spots and other gatherings of game users at specific servers compared to previous methods.

DESIGN OF ANNULAR REVERSIBLE COMBUSTOR WITH 3 DIMENSIONAL CFD ANALYSIS (3차원 CFD해석을 이용한 환형 역류형 연소기설계)

  • Na, S.K.;Shim, J.K.;Park, H.H.;Lee, S.J.;Chen, S.B.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.247-251
    • /
    • 2010
  • It is very difficult to understand and estimate the heat transfer and flow characteristics in the combustor, which is one of main components in the Auxiliary Power Unit (APU), because its flow filed has very complex structure. In this paper, specified is characteristics of injection and flow through different air goles in the liner, which consist of large circular holes film cooling holes, and tangential air swirl holes. The durability of the liner depends on whether the surface of the liner is exposed to the hot gas over 1000 $^{\circ}C$ of a temperature or net. It is proved that the locations of hot spots estimated from the calculation using CFD are matched well with that from the test. In this study, CFD simulations were performed to examine the heat transfer and temperature distributions in and about a liner wall with film cooling on the wall. This computational study is based on the ensemble average continuity, compressible Navier-Stokes, energy, and PDF combustion equations closed by the standard $k-{\varepsilon}$ turbulence model with standard wall functions for the gas phase and the Fourier equations for conduction in the solid phase.

  • PDF

Interaction Effects of Turbulent Flow and Chemical Reaction in a Swirl Combustor (스월연소기의 난류와 화학반응 간섭효과)

  • Sung, Hong-Gye;Kim, Jong-Chan;Yang, Vigor;Cha, Bong-Jun;Ahn, I-Ki
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.71-74
    • /
    • 2007
  • Large Eddy Simulation(LES) has been conducted to insight interaction effects of turbulent flow and chemical reaction of a lean-Premixed swirl combustor. The unsteady turbulent flame is carefully simulated so that the motion of flow and flame can be characterized in detail. Fuel lumps escaping from the primary combustion zone move downstream and consequently produce local hot spots conveying large vortical structures in the azimuthal direction. The correlation between pressure oscillation and unsteady heat release is examined by the spatial and temporal Rayleigh parameter.

  • PDF