• Title/Summary/Keyword: Hot Season

Search Result 236, Processing Time 0.027 seconds

Effects of Mulching Treatments on Fall Cultivation of Potato (피복처리가 감자추작에 미치는 영향)

  • Jung-Hyun Choi;Jae-Young Cho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.23 no.2
    • /
    • pp.126-132
    • /
    • 1978
  • To examine the effects of P.E. film and rice straw mulching on fall grown potato(Shimabara cultivar) in the middle region of Korea, sprouted seed tuber pieces were transplanted with six kinds of mulching treatments on 24th July and harvested on 25th October. P.E. film mulching from transplanting resulted the perfect rot of transplanted seed pieces due to the excessive high soil temperature (noon soil temperature of about 4$0^{\circ}C$ continued until the middle of August). P.E. film mulching from 15th September to harvest increased the marketable tuber yields by 35% due to the raising of soil temperature by 1-3$^{\circ}C$ and maintaining of available soil moisture in dry season. Rice straw (whole or cut in 10cm length) mulching lowered the soil temperature in hot season and raised it in cool season and maintained available soil moisture in dry season. Therefore better emergence, growth and yields were induced. Effects of whole straw, whole growing season and thicker mulching were greater than cut straw, half growing season and thinner mulching. 6cm mulching of whole or cut straw during whole growing season resulted the increasing of marketable tuber yields by 56 or 48%.

  • PDF

Protein Status of Indigenous Nguni and Crossbred Cattle in the Semi-arid Communal Rangelands in South Africa

  • Mapiye, C.;Chimonyo, M.;Dzama, K.;Marufu, M.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.23 no.2
    • /
    • pp.213-225
    • /
    • 2010
  • The objective of the current study was to determine factors influencing concentrations of protein-related blood metabolites in indigenous Nguni and crossbred cattle in the semi-arid communal rangelands in South Africa. The body condition scores (BCS), packed cell volume (PCV) and serum concentrations of protein-related metabolites were determined seasonally in 100 cattle raised on communal rangelands from August 2007 to May 2008. Nguni cattle had lower (p<0.05) albumin-globulin ratio, albumin, urea and creatinine, and higher (p<0.05) globulin concentrations than the local crossbreds. Local crossbreds had higher (p<0.05) alanine aminotransferase and alkaline phosphatase concentrations and lower (p<0.05) aspartate aminotransferase concentrations in the postrainy season than Nguni cattle. The creatinine concentrations of Nguni and crossbred cattle were lowest in the sour rangeland during the hot-wet season. The albumin concentrations of Nguni and crossbred cattle were higher (p<0.05) whilst PCV, albumin-globulin ratio and creatine kinase concentration were lower (p<0.05) in the sour rangeland than in the sweet rangeland. Total protein, albumin, globulin, aspartate aminotransferase and creatine kinase concentrations of Nguni and crossbred cattle were lower (p<0.05) in the hot-wet and late cool-dry seasons than in other seasons across rangeland types. Urea concentrations in both breeds were highest in the sweet rangeland in the hot-dry season compared to other seasons. It was concluded that Nguni cattle had lower concentrations of protein metabolites than local crossbreds and protein deficiencies were most prominent in the sweet rangeland during the cool-dry seasons.

A Experimental Study for Horizontal Geothermal Heat Exchanger System Performance during Intermediate Season (중간기 수평형 지중열교환기의 성능 검토를 위한 실험적 연구)

  • Hwang, Yong Ho;Cho, Sung Woo
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.2
    • /
    • pp.1-6
    • /
    • 2015
  • The horizontal earth-to-air heat exchanger (HEAHES) thermal performance is excellent on cooling and heating season in hot arid regions was reported. But the HEAHES thermal performance results is difficult to find on intermediate season. This paper was performed full scaled experiment to investigate HEAHES thermal performance on intermediate season (Oct. 10th ~ 12th Nov. 12th). When the air entering to HEAHES is the lowest $2.3^{\circ}C$, outlet air temperature from HEAHES is $15.95^{\circ}C$ through PVC pipe that buried length 60m and depth 3m. When the air entering to HEAHES is the highest $24.8^{\circ}C$, outlet air temperature from HEAHES is $22.05^{\circ}C$. During intermediate season, the HEAHES COP is 2.71 in daytime and 6.53 in evening.

A Study for the Technology to Prevent Heat Stroke Deaths with Occupant Detection System in Hot Cars (차량 내 방치된 유아의 열손상 사망사고 방지를 위한 승객감지기술 및 최적 대응방안에 대한 연구)

  • Choi, Eunyoung;Yu, Minsang
    • Journal of Auto-vehicle Safety Association
    • /
    • v.12 no.3
    • /
    • pp.20-26
    • /
    • 2020
  • Many children have died (Heat stroke deaths) in the U.S. after being left alone in cars during hot weather, especially summer season. According to related report, more than 800 children have died of heat stroke from being trapped in a hot car since 1998. The regulation party, government has started to make not only technical regulation to prevent tragedy but also legislate to punish. However the 75% of accident has occurred unintended by their parents. So punishment is not the best solution for this case. So in this study, we analyze the trend of regulation and technology to save occupant who remained back seat. And finally we propose a countermeasure to prevent heat stroke deaths.

A Flow Quantity Distribution Characteristics of the Hot Water Header for Individual Room Control System (실별제어 온수분배기의 유량분배 특성)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.3
    • /
    • pp.175-180
    • /
    • 2008
  • Flow quantity to supply to a coil in floor heating system is important to achieve comfortable indoor air condition in the winter season. The hot water header is used to distribute the water into the coil. Experimental study has been performed using the water header that have 5 branches consisted of flow control valves and automatic shut-off valves. Each branch line connected it with X-L pipe. Experimental tests accomplished it to investigate the flow distribution characteristics of the hot water header. Experimental results show that the selection of the pump head and differential pressure are very important to save running energy of the system, and high differential pressure needs more friction loss in the case of suitable differential pressure for balancing of the header.

Thermal Performance Analysis of Renewable Hybrid heat Supply System for Zero Carbon Green Home of Apartment (공동주택의 제로카본 그린홈을 위한 신재생에너지 하이브리드 열공급 시스템의 열성능 분석)

  • Joo, Hong-Jin;Lee, Kyoung-Ho;Kwak, Hee-Youl
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.451-456
    • /
    • 2012
  • This study was carried out to evaluate thermal performance of the renewable hybrid heat supply system with solar thermal system and wood pellet boiler for Zero Carbon Green home of apartment houses. The hybrid heat supply system was set up at Korea Institute Energy Research in 2011. The system was comprised of the wood pellet boiler unit with heat capacity designed as 20,000 kacal/hr, a evacuated tubular solar collector 3.74 $m^2$ of aperture area at the $20^{\circ}$ install angle, a 0.3 $m^3$ hot water storage tank, a 0.15 $m^3$ hot water storage tank for space heating. Thermal performance tests for one-house of apartment house were carried out by hot water load and heating load in winter season through the hybrid heat supply system. As a result, hot water energy supplied by the hybrid heat supply system was 11kWh in a day. Solar thermal energy portion was 2.99kWh which is 27% of the total hot water energy supply. wood pellet boiler supply portion was 8.017kWh which is 73% of the total hot water energy supply.

  • PDF

Studies on the Cow Feces Composting in Cold Season (저온기간중 우분의 퇴비화에 관한 연구)

  • 정광화;김원호;김맹중;서성;고응규
    • Journal of Animal Environmental Science
    • /
    • v.4 no.1
    • /
    • pp.55-61
    • /
    • 1998
  • Cow feces excreted in cold season should be managed and composted properly, because the composted feces is distributed to pasture or cultivated land as a fertilizer in spring. Generally it is admitted that the effect of composting is suppressed by low temperature in cold season. In this study, composting piles were warmed by hot air until temperature of compost piles were reached at 35∼40$^{\circ}C$, to compare composting effect of experimental compost pile to control pile exposed in cold air. Some results obtained from the experiment during composting of cow feces mixed with bulking agent provide a possibility of active composting of organic matters in cold season. The biodegradation ratios of organic matter during composting in four types of composts were 10.2% for the rice straw, 7.7% for the rice hull, 6.4% for the sawdust and 4.3% for the control. The highest temperatures of compost piles during composting period were 76$^{\circ}C$ in sawdust, 80$^{\circ}C$ in rice hull, 68$^{\circ}C$ in rice straw, 45$^{\circ}C$ in control. Moisture content, pH, C/N, volume of compost were decreased during composting period, but EC value was increased with ionization of organic molecular by fermentation.

Regulation of Spider Mite Populations by Predacious Mite Complex in an Unsprayed Apple Orchard (장기간 약제 무살포 사과원에서 포식성 응애류에 의한 잎응애류 밀도 억제)

  • 김동순;정철의;김시용;전홍용;이준호
    • Korean journal of applied entomology
    • /
    • v.42 no.3
    • /
    • pp.257-262
    • /
    • 2003
  • Spider mites and their predacious mites were surveyed in an apple orchard where pesticides have not been applied for a long time, to understand the undisrupted predacious mite complex and their role in the controling spider mites. Spider mites occurring in the orchard were different to those in conventional orchards. A few Tetranychus urticae and Panonychus ulmi were observed, while T. kanzawai was abundant during growing season. Four species of phytoseiids, Amblyseius eharai, A. kokufuensis, A. womersleyi and Typhlodromus vulgaris, and one stigmaeid species of Agistemus terminalis were observed from leaf samples in the orchard. Among them, T. vulgaris occurred from early cool season with low T. kanzawai densities through to mid-and late-season. A. womersleyi was observed only during mid-season when T. kanzawai densities were high with hot weather. Amblyseius eharai and A. kokufuensis occured only in early season, but A. terminalis density increased from mid-season and lasted to late-season. The predacious mite complex regulated the density of T. kanzawai approximately under 8 mites per leaf. Tentatively concluding, T. vulgaris is an adaptable predator at lower prey density under cool weather condition, and A. womersleyi is effective predator at higher prey density under hot weather condition. Further, the biological control strategies of spider mites in Korean orchards were discussed based on the predacious mite complex.

Heat Transfer Characteristics of Coil Tube Heat Exchanger for Hot Water Heating of Greenhouse Thermal Tunnel (보온터널 난방을 위한 온수난방용 코일튜브 열교환기의 열전달 특성)

  • Ryou, Y.S.;Kang, K.C.;Kim, Y.J.;Paek, Y.;Kang, Y.G.;Lee, H.M.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.5 s.118
    • /
    • pp.430-435
    • /
    • 2006
  • Greenhouse horticulture in South Korea covered about 52,000 ha in 2005. Greenhouse area of about 12,000 ha has been heated during winter season with heating cost of $20{\sim}40%$ of total Production cost. Farmers engaged in greenhouse horticulture were changed into aged people. Therefore the laborsaving of working process and the saving of greenhouse heating cost should be accomplished simultaneously to increase income of greenhouse horticulture. The best method for saving of greenhouse heating cost is to install thermal tunnels into greenhouse. Then hot air heaters using fossil fuel should be changed into hot water heaters. In other words air heating using forced convection should be changed into natural convection system. In this research coil tube made of flexible PE pipe was designed as hot water heat exchanger and its heat exchanging characteristics were analyzed. This new heat exchanger has been adopted as a natural convection system for hot water heating of greenhouse horticulture.

Actual State of Practical Use and Thermal Environment of Greenhouses in Summer Season (하절기 온실의 활용실태 및 열환경분석)

  • 남상운;김문기
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.418-423
    • /
    • 1999
  • This study was performed to find an efficient method to overcome extremely high temperature within greehhouse in summer season. The actual states of practical use for greenhouse in hot summer season were investigated. About 21.6% of the investigated greenhouse farms were no cultivation, and most greenhouse farms were cultivating under the very inferior environment . To examine thermal enviornment of greenhouse according to cooling or assistant cooling , greenhouses were treated with natural ventilation, shading, roof sprinkling , and evaporative cooling with air cool fan. Shading and operating air col fan showed a drop in temperature of 3.8∼4.2$^{\circ}C$ as compared with natural ventilation, and most greenhouse air temperatures were maintained below 35$^{\circ}C$.

  • PDF