• Title/Summary/Keyword: Host and Equipment

Search Result 35, Processing Time 0.026 seconds

Analysis and Evaluation of Pathogen Contamination Status in Interventional Angiography Room (인터벤션실의 오염실태 분석 및 평가)

  • Kim, Kyung-Wan;Im, In-Chul
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.233-239
    • /
    • 2022
  • In the radiology department, where radiation is used in medical institutions to perform examinations with various equipment, the field of surgical treatment is the intervention angiography room. Accordingly, strict infection control is required. The purpose of this study was to determine the contamination status by detecting pathogens before and after disinfection in the intervention angiography room, and to determine the degree of death by using a disinfectant, sodium dichloride isocyanurate, which is mainly used in the intervention angiography room. The subjects were 10 medical institutions of general hospital level or higher with an intervention angiography room in the P city, and 12 places with high contact frequency during examinations and procedures were sampled and requested to an analysis institution. As for the sample collection method, up/down, left/right directions were used to increase precision. Before disinfection, all procedures were completed, and after disinfection, exposure was performed using a disinfectant for at least 10 minutes, and detection was performed using a transport medium. As a result, in the pathogen analysis, most pathogens were detected in a humid environment or in a place with high contact frequency for microorganisms to thrive. The detected pathogens were found in the general environment or were human flora. It is a pathogen that does not cause disease under normal healthy host conditions. However, it was found to be an opportunistic infection that causes opportunistic infection depending on the case or situation in which the body's resistance is weakened. In addition, as a result of using the disinfectant mainly used in the intervention angiography room, it was found that more than 93.3% of them died. Therefore, the data of this study will be used as good basic data for the evaluation of pathogens in the intervention angiography room and will be of great help in infection control.

Evaluation of Extended Canine Semen after Different Filtration Treatment (개 희석 정액의 다양한 filtration 처리 후 정자평가)

  • Kim, Yong-Jun;Kim, Jin-Young;Kim, Sue-Hee;Lee, Young-Jun
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.577-583
    • /
    • 2007
  • It is important to obtain semen with good quality for efficient fertilization and pregnancy. To obtain these semen, various methods have been developed but most of these methods are time consuming and require costly equipment. Therefore, the objective of this research is to investigate the usability of column filtration system as quick and simple method to get sperm with better quality. Ejaculates were obtained from 5 dogs and analyzed with basic quality parameters before each filtration. Sperm concentration was adjusted to $5{\times}10^7/ml$ after dilution. The experimental groups were divided into non-filtered group(control) and filtered groups(glass wool, Sephadex 5% and Sephadex 20%). Ejaculates were filtered through each filter system and assessed by recovery rate of sperm, motility, normal morphology, CFDA/PI stain and plasma membrane integrity(hypo-osmotic swelling test, HOST). The lowest recovery rate of spermatozoa was recorded in glass wool filtration group, followed by 20% Sephadex filtration group(p<0.05). There was no significant difference between control(non-filtered) and 5% Sephadex filtration poop. Also, there was no significant difference of sperm motility assessed under light microscope among experimental groups. Morphological normality of canine spermatozoa was the highest in the glass wool filtration group and the lowest in the 5% Sephadex filtration group with no significant differences versus 20% Sephadex filtration and control group, respectively(p<0.05). Viability of canine sperm assessed by CFCA/PI staining was the highest in the glass wool filtration poop with no significant difference versus the control group, and the lowest in the 20% Sephadex filtration group with no significant difference versus 5% Sephadex filtration group, respectively(p<0.05). HOS values of canine sperm was the highest in the 20% Sephadex filtration group with no significant difference versus 5% Sephadex filtration group, and the lowest in the control poop with no significant difference versus glass wool filtration group, respectively(p<0.05). Therefore, these results indicated that filtration treatment for extended canine sperm would be useful method to get sperm with better quality by trapping the damaged sperm, consequently filter would be physical barrier against injured or immotile sperm.

Development of a Photoplethysmographic method using a CMOS image sensor for Smartphone (스마트폰의 CMOS 영상센서를 이용한 광용적맥파 측정방법 개발)

  • Kim, Ho Chul;Jung, Wonsik;Lee, Kwonhee;Nam, Ki Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4021-4030
    • /
    • 2015
  • Pulse wave is the physiological responses through the autonomic nervous system such as ECG. It is relatively convenient because it can measure the signal just by applying a sensor on a finger. So, it can be usefully employed in the field of U-Healthcare. The objects of this study are acquiring the PPG (Photoplethysmography) one of the way of measuring the pulse waves in non-invasive way using the CMOS image sensor on a smartphone camera, developing the portable system judging stressful or not, and confirming the applicability in the field of u-Healthcare. PPG was acquired by using image data from smartphone camera without separate sensors and analyzed. Also, with that image signal data, HRV (Heart Rate Variability) and stress index were offered users by just using smartphone without separate host equipment. In addition, the reliability and accuracy of acquired data were improved by developing additional hardware device. From these experiments, we can confirm that measuring heart rate through the PPG, and the stress index for analysis the stress degree using the image of a smartphone camera are possible. In this study, we used a smartphone camera, not commercialized product or standardized sensor, so it has low resolution than those of using commercialized external sensor. However, despite this disadvantage, it can be usefully employed as the u-Healthcare device because it can obtain the promising data by developing additional external device for improvement reliability of result and optimization algorithm.

A Study on Actual Conditions for Prevention of Infections by Dental Hygienists (치과위생사의 감염 예방 실태 조사)

  • Nam, Young-Shin;Yoo, Jung-Sook;Park, Myung-Suk
    • Journal of dental hygiene science
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • This study aimed to provide basic information on dental hygienists' practicing the prevention of infections by figuring out their actual conditions in dental clinics. The subjects of the study were the dental hygienists who participated in the continuing medical education of Incheon & Gyeonggi-do association and Seoul city association in October and November 2005 and the self-administered surveys were used for the prevention of infections. The results were as below. 1. In terms of education experiences of infection prevention, those who answered "there were" were 72 persons (42.9%) and those who followed the educational route for infection prevention were "through the in-house education from the hospital" and they were 42 persons (58%), which were highest. 2. In terms of the injury experiences, those who answered "there were" were 147 persons (87.5%) and the number of annual injury out of 147 persons with injury experiences was 7.7 time. For the tools that were damaged, 125 persons (75%) damaged the "explorer," which was highest. 3. For the experiences of being infected with contagious diseases, those who answered "there were" were 6 persons (3.6%) and there were four persons for "hepatitis B", one person for "rubella" and one person for "TB." 4. The questions with high practice scores were as in the following: "2. I wash my hands after conducting medical examinations (1.86 points)," "7. I always close the lid of a shot of Novocain after doing local anesthesia (1.86 points)" and "20. I separate and collect the wastes and give them to those who treat accumulated materials (1.85 points)". Meanwhile, the questions with low practice scores were as below: "16. I change my medical gowns (doctor wears) once a day (0.24 point)" and "I wash my medical gowns every time after examining patients with contagious diseases (0.52 points)." 5. The question with high knowledge was as below: "1. The contagion during the dental treatment is determined by source of infection, infection methods, infection routes and the host that is prone to infection (0.95 point)" and the question with the lowest knowledge was "5. HBV(hepatitis B) is destroyed after adding 95oC of heat for more than 5 minutes (0.27 points)." 6. The question with the highest organization-related factors was "I am always ready to use a mask, gloves, etc. if necessary" (0.89 points)" and the question with the lowest score was "There is a guideline that I can refer when I am exposed to dangerous situations related to the contagion in my workplace (0.33 point)." 7. In terms of the equipment conditions of protectors in medical environments, 168 persons for (disposable) mask (100%), 167 persons for disposable gloves (Latex) (99.4%), which meant that most of them were equipped with them. On the contrary, 108 persons (64.3%) are equipped with the protectors for frontal faces, which is the lowest and 165 persons (98.2%) said that they had autoclave in their disinfecting and sterilizing devices.

  • PDF

Development and Preliminary Evaluation of a Leukocyte Removal Aptamer Filter (압타머를 이용한 백혈구제거필터의 개발 및 예비평가)

  • Lee, Yangwon;Jung, Eun-Suk;Choi, Kyoung Young;Kim, Myung Han;Kwon, So Yong;Cho, Nam Sun;Kim, Jin Sook;Park, Han Jeong;Han, Byoung Don;Yoon, Soo-Young
    • The Korean Journal of Blood Transfusion
    • /
    • v.23 no.2
    • /
    • pp.107-114
    • /
    • 2012
  • Background: Leukocyte reduction filters are widely used to prevent transfusion reactions caused by leukocytes in blood components. Commercial filters are not sufficient for removal of leukocytes for prevention of transfusion associated graft-versus-host disease; therefore, irradiation of blood components was performed using expensive equipment. Techniques using an aptamer substituted for antibody have been developed and are available in clinical areas. The purpose of this study is to develop the aptamer filter system and to evaluate its efficiency and the possibility of its clinical application. Methods: Aptamers targeted to CD45 were selected by the Postech Aptamer Initiative. The aptamer filter in which aptamers attached to beads were bound to leukocytes and removed by magnetic field was developed. Filtration of 14 units of leukoreduction-red blood provided by Korean Red Cross Blood Services was performed using aptamer filters. Leukocyte removal rate and red cell recovery rate were evaluated and bacterial culture was performed. Results: After filtration using the aptamer filters, 45.6% of leukocytes were additionally removed and the red cell recovery rate was 92.8%. No growth in the bacterial culture was observed. Conclusion: In order to apply the cell depletion technique utilizing an aptamer to blood filter system, we developed and evaluated the aptamer filter system. Through improvement of the binding efficiency of the aptamer and the filtering process, and application of the various aptamers for other different cells, we suggest that this technique can be applied in the clinical area, such as a substitution for the irradiation process for TAGVHD prevention.