• 제목/요약/키워드: Hospital ward

검색결과 673건 처리시간 0.018초

User Satisfaction with Their Ward Environments for User-Oriented Design (사용자 중심적인 병동부 디자인을 위한 사용자 만족도 조사 - 부산시 A 종합병원에 대한 사례연구를 중심으로 -)

  • 이양경;오찬옥
    • Korean Institute of Interior Design Journal
    • /
    • 제38호
    • /
    • pp.173-181
    • /
    • 2003
  • This study was intended to investigate the satisfaction degree of users with ward design, and on the basis of this, to suggest the design guidelines of user-oriented general hospital ward. A general hospital in Busan was case-studied. Subjects were 49 patients, 50 families, 50 nurses in this hospital. The results were as follows; The satisfaction degree of users with the psychological factors of ward design was relatively low, while the user satisfaction degree with the functional aspects was relatively high. As for the difference among users, the satisfaction degree of patients and their families with the functional aspects of ward design was higher than that of nurses, and there were no many cases to show the difference among users' satisfaction degree with the psychological factors.

A Study on the Air Counts and the Infection of Maternity in n General Hospital (병실 낙하균 및 산모감염에 관한 연구)

  • 이남희
    • Journal of Korean Academy of Nursing
    • /
    • 제9권2호
    • /
    • pp.17-26
    • /
    • 1979
  • This research is to prevent the infection of maternity in the hospital by examining the microbes contaminations in maternity through airbone microbes and those who are engaged in the ward of O.B. & G.Y. and to furnish the basic data available to hospital management. The bacterial growth of airbone microbes contaminations in nosocomial air and who thor the nasal cavity of passers by (doctors, nurses, parturient women) who went to the ward of O.B. & G.Y. contaminated or not were examined in“E”Univ. Hospital from July to August, 1979 by using thioglycollate broths and agar plates. The following results were obtained: 1. The average colony number of airborne microbes revealed as follows the pediatric ward (36 colonies), the internal ward (33 colonies), the ward of O.B. & G.Y. (30 colonies), the ward of surgery (24 colonies), delivery-waiting room (11 colonies), and the delivery room (3 colonies). 2. The bacterial growth beforenoon differed from that of afternoon. Namely, the latter (24 colonies) was higher than the former (21 colonies). 3. The type of strains isolated from the air of the ward revealed staphylococci (82%), Gram negative bacilli (18%), fungi (17%), Gram positive diplococci (13%), and Bacillus subtilis (2.8%). 4. The strains isolated in the delivery-waiting room revealed staphylococci (66.7%), Gram negative bacilli (33.6%), and revealed staphylococci (75%), Gram positive diplococci (8.3%), and fungi (8.3%), in delivery room. 5. Most of strains isolated in the ward of O.B. & G.Y. revealed staphylococci (100.0%), Gram positive diplococci (8.3%), and Gram negative bacilli (6.7%). 6. The strain isolated in the surgical ward revealed staphylococci (91.7%), fungi (33.3%), Gram positive diplococci (25%), Gram negative bacilli (25%) and Bacillus subtilis (8.3%). 7. The strain isolated in the pediatric ward revealed staphylococci (75%), fungi (25%), Gram positive diplococci (8.3%), Bacillus subtilis (8.3%), and Gram negative bacilli (8.3%). 8. The strain isolated in the internal ward revealed staphylococci (91.7%), fungi (33.3%), Gram positive diplococci (25%), and negative bacilli (16.7%). The strains isolated from the nasal cavity of those doctors and nurses who and enaged in the ward of O.B. & G.Y. revealed staphylococci (80%), Bacillus subtilis (10%), and Gram negative bacilli (10%), from doctors and Gram positive diplococci (10%), instead of Gram negative bacilli (10%), from nurses. 10. The strain isolated from nasal cavity of parturient women on admission revealed staphylococci (90%), and Gram negative bacilli (10%), but after admission revealed staphylococci (70%), Gram positive diplococci (10%), and Gram negative bacilli (10%). 11. Of the total 91 staphylococci isolated from the air of the ward, the Coagulase pastive was 36 (39.6%), and the negative 55 (60.4%), As a result of the coagulase experiment of the staphylococci isolated from the nasal cavity of those who are engaged in the ward of O.B. & G.Y. all were revealed as negative that belonged to non-pathogenic. 12. Consequence of the biochemic examination of the gram negative bacilli isolated from the air of the ward the aerobacter aerogens revealed was (16.7%) E-coli 5% in the nasal cavity of those came and went to the of O.B. & G.Y. and Aerobacter aerogens 7.5%.

  • PDF

A Study on the Architectural Planning for Integrated Nursing Care Service in Ward of Public Hospital - Focused on the Regional Public Hospital in Korea - (간호·간병통합서비스를 위한 국내 공공병원 병동부에 대한 건축 계획적 연구 - 국내 지역거점 지방의료원을 중심으로 -)

  • Han, Suk-Bum;Park, Jae-Seung
    • Korean Institute of Interior Design Journal
    • /
    • 제26권3호
    • /
    • pp.121-129
    • /
    • 2017
  • The study is to identify the status of the ward of public hospital for integrated nursing care service. Integrated nursing service has expanded nationwide from 2016 but 10 out of 34 public hospitals are currently unable to operate as nurses due to the shortage. Analyze each floor plan and space program of ward and provide the basic data for the construction of the architecture plans for Integrated nursing care service. For this study, selecting 14 wards of public hospital in Korea and then analyzes space organization, distance from NS to bedroom and NS to core(Elevator) and spatial hierarchy of them. Among the 14 public hospitals, there are 7 types of double-loaded corridor, 4 types of double corridor and 3 types of single corridor. If NS is placed centrally, the control of the outsider and the patient's control would be efficient, but most of NS are lean on one side of floor. the placement of NS should be independent of individual arrangements, but it should be smooth alignment with patient spaces, staff spaces, and public spaces. This study could serve as basic research for the architectural plan for future integrated nursing care in ward of public hospital.

Characteristics of Spatial Environment in Psychiatric Wards through the Analysis by Patient's Preferred Healing Environment in Observational Ward Structure Dividing Staff Area and Patient Area (정신요양 병동에서의 관리영역과 환자의 요양 공간영역의 관찰적 시선에 따른 병동구조와 요양 공간환경의 특성에 관한 연구)

  • Joo, Yongsun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • 제27권2호
    • /
    • pp.57-64
    • /
    • 2021
  • Purpose: The relationship between the staff area and the patient's private area is the key factor in designing the structure and the environmental characteristics of ward spaces in a psychiatric hospital. Recent research has found that for the purpose of treatment and securing privacy, psychiatric patients need to be in an open space of relief rather than closed confined environment and under the watch of nursing staffs. Methods: A survey at three kinds of wards in a private psychiatric hospital in Japan was conducted in October 2002. These wards include an acute ward, a psychiatric convalescence ward, and a stress care ward. All three kinds of wards have the same structure. At each ward, spatial preferences of the 145 psychiatric inpatients were surveyed and data concerning the patient's diagnostic category, symptoms, and activities of daily living were recorded. Results: The patients in the stress care ward prefer to stay in private spaces than public spaces. On the other hand, in the acute ward the patients seem to have a preference between managed public spaces where are monitored by nursing staffs and their private rooms where the nurse station is close. In addition, the patients in the psychiatric convalescence ward spend most of their time in the public space, such as the hallways or the day room. Implications: Base on this research, the spaces at the acute ward that could be monitored by the nursing station serves effectively as a safety space for patients was concluded. However, in the stress care ward, the patients may perceive the monitoring by the nursing staff as interruption or nuisance to their relaxation. In order to design an ideal healing environment for psychiatric patients in psychiatric ward, it is important to consider how environmental characteristics of space affect the environmental sense of patients in each ward.

Assessment of Thermal Comfort in a General Hospital in Winter Using Predicted Mean Vote (PMV) (Predicted Mean Vote(PMV)를 이용한 겨울철 종합병원의 실내 온·열 환경의 평가)

  • Lee, Boram;Kim, Jeonghoon;Kim, KyooSang;Kim, Hyejin;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • 제41권6호
    • /
    • pp.389-396
    • /
    • 2015
  • Objectives: A hospital is a complex building that serves many different purposes. It has a major impact on patient's well-being as well as on the work efficiency of the hospital staff. Thermal comfort is one of the major factors in indoor comfort. The purpose of this study was to determine thermal comfort in various locations in a hospital. Methods: Various indoor environmental conditions in a general hospital were measured in February 2014. The predicted mean vote (PMV) and carbon dioxide ($CO_2$) concentration were measured simultaneously in the lobby, office, restaurant, and ward. Results: The ward was the most thermally comfortable location (PMV=0.44) and the lobby was the most uncomfortable (PMV = -1.39). However, the $CO_2$ concentration was the highest in the ward (896 ppm) and the lowest in the lobby (572 ppm). The average PMV value was the most comfortable in the ward and the lowest in the lobby. In contrast, for concentration of carbon dioxide, the highest average was in the ward and the lowest in the lobby. Due to air conditioner operation, during operating hours the PMV showed values close to 0 compared to the non-operating time. Correlation between PMV and $CO_2$ differed by location. Conclusion: The PMV and concentration of carbon dioxide of the hospital lobby, office, restaurant and ward varied. The relationship between PMV and carbon dioxide differed by location. Consideration of how to apply PMV and carbon dioxide is needed when evaluating indoor comfort.

A Study on The Architectural Planning of The Ward's Character of The Women's Hospital (여성전문병원 병동부의 특성에 관한 건축계획적 연구)

  • Moon, Byung-Geon;Park, Jae-Seung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • 제8권2호
    • /
    • pp.7-16
    • /
    • 2002
  • Modern society gradually change into diversification and specialization, the field of medical service also is specialized in these days. According to changes, A medical institution stress the need of women's min space of the concept "Well Women Clinic" Therefore, this study aims to propose improve way and architectural data after analysis the developing circumstances and problem on the architectural planning on the ward of women's hospital by case studies on the ward of women's hospital builded recently in korea.

  • PDF

A Case Study on the Interior Environment of Ward in Women's Hospital (여성전문병원 병동부의 실내환경 실태조사)

  • Kim, Yu-Yeon;Hwang, Yeon-Sook
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 한국실내디자인학회 2006년도 춘계학술발표대회 논문집
    • /
    • pp.79-82
    • /
    • 2006
  • Medical institution has changed into specialized spaces for patients. In particular, women's hospital is the most noticeable change among the medical institutions. The purpose of this study is to provide a basic interior design data through the analysis of case study. For this purpose this study has analyzed of 4 women's hospital built in Seoul since 2000. Especially, environment of ward, resting room, and corridor are analyzed. The results of this study are as follows : Ward needs lighting and room conditioning system which is adjustable for each patient. One-side corridor and alcove-style resting rooms are suitable for patients in general.

  • PDF

A Study on the Ward Module according to the External Design of the Hospital (병원 외주부 디자인에 따른 병실모듈 연구)

  • Lee, Hyunjin;Park, Wonbae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • 제27권3호
    • /
    • pp.71-78
    • /
    • 2021
  • Purpose: It is important to plan the ward module at a time when the size of beds, the floor area, and the construction budget are all set prior to the hospital design. In this context this study aims (1) to derive various factors affecting the ward module, and (2) to analyze the appropriate room module according to the type. Methods: Design factors related to hospital modules are derived through precedential studies, and the types of ward elevation are classified by reviewing the drawings of 18 case hospitals. And the detailed dimensions and area of the derived elements are analyzed. Results: The X-axis modules of the ward are switched to long span structural columns of 9.9 m, 12.6 m and 13.2 m, but the ward modules still represent 6.6 m. The Y-axis module of the ward shows a dimension of 9 to 9.9m in the process of changing a multi-person room into a four-person room. Type A of curtain wall with columns located on the wall of the room and type B of curtain wall located in the center of the room are analyzed due to their variations. The square window type, which forms the elevation of the square window by exposing the columns to the elevation, and the outframe type, which protrudes from the structural columns and beams, have elevation designs limited. There are, however, no obstacles to the interior space of the hospital room, so the wall composition and furniture arrangement are expected to be free. The ward area of Curtain Wall Type A, which can secure an effective area of 5.9m*5.0m, are 52.1m2. The Curtain Wall Type A, Square window type, and the outframe type are 49.8m2. Implications: As part of the hospital standard module plan for economical and reasonable hospital building planning, a type was proposed in this study in conjunction with the external design. It is hoped that it be a base for standard module research linked together to the Central Treatment department, Outpatient department and underground parking lot.

A Study on the Healing Rest Space in Pediatric Ward (소아병동의 치유적 휴게공간에 관한 연구)

  • Jung, So Young;Kim, Ye-Seul;Choi, Kwangseok
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • 제19권1호
    • /
    • pp.23-34
    • /
    • 2013
  • Purpose: Many researches have clearly begun to address the relationship between people and their physical environments. These represent that children experience traditional hospital environments as unpleasant and scary. More specifically, children in hospitals face many psychological and emotional challenges: isolation, painful procedures, separation from family members, all in unfamiliar settings. For this reason, some have argued that the children's experiences within hospital environments can lead to poorer health outcomes. This study has been started in order to provide basic informations for the planning of Healing rest space in pediatric ward. Methods: Literature reviewes and field surveys to rest space at pediatric ward in Korea and foreign country have been conducted for the data collection. Results: The result of this study can be summarized into eight environment factor for healing rest space in pediatric ward: family, noise, safe, choice opportunity, light, privacy, social support and distract from disease or death. Implications: In the rest space in pediatric ward, it is necessary to consider healing rest space for promoting healing from disease and normal developing of children.

A Study on Ward of Public Hospital for Spatial Composition of Efficient Integrated Nursing Care Service - Focused on the Regional Public Hospital - (효율적 간호·간병통합서비스 공간 조성을 위한 공공병원 병동부에 관한 연구 - 지역거점 지방의료원을 중심으로 -)

  • Han, Suk-Bum;Park, Jae-Seung
    • Korean Institute of Interior Design Journal
    • /
    • 제26권6호
    • /
    • pp.71-80
    • /
    • 2017
  • The purpose of this study is identify the status of the ward of public hospital for integrated nursing care service. Integrated nursing care service has been expanding on a national scale from 2016 but most of public hospitals are currently unable to operate due to nursing shortage. In this study 8 wards of public hospital have been chosen and analyzed. The measure of space program and area distribution(patient area percentage, staff area percentage, circulation area percentage), nurses's walking distance(distance from ns to patient room, distance from ns to core) were calculated by depthmapX and autocad programs. The result of this study is as follows. Nurse's walking distance is more than 24m so the efficiency of nurse's patient care is reduced. The percentage of patient area in double-corridor is higher and the patient feels more comfortable but the Nurse's walking distance is longer and the accessibility is lowered. NS should be located in the center of the ward and close to the core but some wards are not composed of proper space-separation and flow of human trrafic is overlapped. This study may serve as basic research for the architectural plan for future integrated nursing care ward.