• Title/Summary/Keyword: Hospital performance

Search Result 2,928, Processing Time 0.028 seconds

A Study on the Factors that Determine the Initial Success of Start-Up (스타트업의 초기 성공을 결정하는 요인에 관한 연구)

  • Lee, Hyun Ho;Yun, Hwangbo;Gong, Chang-Hoon
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.12 no.1
    • /
    • pp.1-13
    • /
    • 2017
  • The purpose of this study is to find out which factors determine the success of start-up in the initial market and what are the most important determinants. For the empirical analysis, the questionnaire related to the analysis of success factors for start-up success was designed according to the quantitative analysis (AHP technique). First, we selected 8 representative success factors for successful start-up in the initial market. In order to determine the degree of priority among these factors, we surveyed 12 entrepreneurs who are interested in entrepreneurship, universities, research institutes, and public officials. As a result of the empirical analysis, 51% of the funds in the tier 1 were ranked as the top priority to determine success factors. Followed by research and development (32.5%), management (8.7%) and marketing (7.8%). In particular, when each of the four items is calculated as 100 according to the result of the tier 1, and the tier 2 is converted, the foreign investment is analyzed as 43.7%. It was followed by 15.14% of R & D facilities, 14.07% of ideas, 8.7% of managerial ability, 7.29% of domestic investment, 5.85% of buyer feedback, 3.3% of development strategy and 1.95% of marketing strategy. Among the eight success factors, overseas investment items showed the closest preference to half, and it was the most important variable that determines the success or failure of market entry. The implication of this study is that many start-ups in Korea expect to receive investment and support from overseas accelerators. This means that overseas investment itself has been recognized as a start-up that makes services and products that can be used in the global market. A high preference for attracting foreign investment is due to the fact that the amount of investment is larger than that of Korea and that it can flexibly cope with the pressure on the performance compared to domestic investors. In this study, it was meaningful that we could confirm this fact through questionnaires of start-up experts. In future research, we need to find a viable alternative through studying how to provide start-up to foreign direct investment at the national level.

  • PDF

Clinical Characteristics in Patients for Mental Disability Assessment Following Traumatic Brain Injury -Comparison between Patients with and without Abnormal Brain Imaging- (두부외상 후 장애평가 환자들의 임상적 특징 -뇌영상검사 이상유무에 따른 비교-)

  • Ha, Kang-Su;Kim, Sang-Hoon;Kim, Hack-Ryul;Park, Sang-Hag;Pyo, Kyung-Sik;Cho, Yong-Rae
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.9 no.1
    • /
    • pp.28-36
    • /
    • 2001
  • Objectives : This study was undertaken to identify the clinical and psychological characteristics in patients of mental disability assessment following traumatic brain injury who had the finding with or without abnormal brain imaging study. Methods : A consecutive series of 59 patients were assessed in hospital from January 1994 to December 1998. Patients were divided into 2 groups based on normal or abnormal brain imaging and the two groups were compared in demographic characteristics, psychiatric symptoms, type of head injury, clinical psychological findings. There were 27 patients with abnormal findings and 32 with normal findings in brain imaging study. Results : Abnormal finding group in brain imaging study had significantly higher incidence of psychosis, decreased memory, decreased appetite, increased nihilistic idea, and intracranial hemorrhage. Also, abnormal finding group showed significantly lower level of performance on the block design subtest of K-WAIS and had significantly lower scores on F, hypochodriasis, depression, hysteria, psychopathic deviate, psychasthenia and schizophrenia subscale of the MMPI. Conclusion : The findings suggest that the patients undergone brain surgery due to intracranial hemorrage at that time of brain injury may have higher frequency of abnormal findings in brain imaging study, complain more cognitive and affective symptoms, and have lower the abstract concept formation and perceptual organization abilities.

  • PDF

Analysis of characteristics affecting the score-groups by supervisor and subordinate rating (하향평가와 상향평가 결과에 영향을 미치는 특성 분석)

  • Shin Ki Soo;Cho Woo Hyun;Park Young Yo;Jung Sang Huyk;Lee Hye Jean
    • Health Policy and Management
    • /
    • v.15 no.1
    • /
    • pp.97-117
    • /
    • 2005
  • This study was designed to compare the differences m results of supervisor and subordinate rating. Data was collected from personnel evaluation and subordinate rating results for middle managers(n=68) in hospital from 3rd January to 20th March in 2004. Supervisor rating consisted of performance, ability and attitude evaluation. Subordinate rating consisted of leadership, ability and attitude evaluation. Collected data included sociodemographic characteristics, work department, work level, years of work, years at present level and whether working in a patient serving department. The difference of standardized supervisor and subordinate rating score was used to define groups as 'higher in supervisor rating group'. Groups were defined in total score, ability score and attitude score. Main results were as follows: 1. In total score, sectional chiefs were apt to be 'higher in subordinate rating group' while chief clerks were apt to be 'similar group' or 'higher in supervisor rating group'. Staffs in patient serving department were likely to be 'higher in supervisor rating group' and staffs in non-patient serving department were likely to be 'higher in subordinate rating group'. All these results were statistically significant. 2. In ability score, there were no statistically significant differences in age, sex, years of education, work department, work level, years of work and whether working in a patient serving department among 'higher in supervisor rating group', 'similar group' and 'higher in subordinate rating group'. 3. In attitude score, staffs in the department of medical affairs and the department of administration were apt to be 'higher in subordinate rating group'. Staffs in the department of nursing were apt to be 'higher in supervisor rating group'. Staffs in a patient serving department were likely to be 'higher in supervisor rating group' and staffs in a non-patient serving department were likely to be 'higher in subordinate rating group'. All these results were statistically significant. 4. Logistic analysis about total score showed that sectional chiefs had higher Odds Ratio(OR) to be in 'higher in subordinate rating group'. Staffs in a non-patient serving department had higher OR to be in 'higher in subordinate rating group'. Both these results were statistically significant. 5. Logistic analysis about ability score showed that sectional chiefs had higher OR to be in 'higher in subordinate rating group'. Staffs in a non-patient serving department had higher OR to be in 'higher in subordinate rating group'. These results were not statistically significant. 6. Logistic analysis about total score showed that sectional chiefs had higher OR to be in 'higher in subordinate rating group', but the difference was not statistically significant. Staffs in a non-patient serving department had significantly higher OR to be in 'higher in subordinate rating group'. In conclusion, there is no clear superiority between supervisor and subordinate rating in personnel evaluation. It would be better to use a mixed model. It's also suggested to use an intervening rate of application or scores considering work levels and work department in personnel evaluation. These results would be helpful for hospitals planning a supervisor and subordinate rating system for personnel evaluation.

Effects of Contrast Improvement on High Voltage Rectification Type of X-ray Diagnostic Apparatus (X선 진단장치의 고압정류방식이 대조도 향상에 미치는 영향)

  • Lee, Hoo-Min;Yoon, Joon;Kim, Hyun-Ju
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.187-193
    • /
    • 2014
  • The purpose of this study was to analyze the effect on the selectivity on of high-voltage rectification device that measured the performance of the grid, and the contrast improvement ability (K factor) by measuring the scattered radiation content of the transmitted X-rays. The scattered radiation generated when the X-ray flux comes from the diagnostic X-ray generator that passes through an object. Targeting four different rectifications of X-ray generators, the mean value of the tube voltage and the tube current was measured in order to maximize the accuracy of the generating power dose within the same exposure condition. Using fluorescence meter, the content of the scattered rays that are transmitted through the acrylic was measured depending on the grid usage. When grid is not used, the content of the scattered rays was the lowest (34.158%) with the single-phase rectifier, was increased with the inverter rectifier (37.043%) and the three-phase 24-peak rectification method (37.447%). The difference of the scattered radiation content of each device was significant from the lowest 0.404% to the highest 3.289% while using 8:1 grid, the content of the scattered ray was the lowest with the single content of the scattered ray was the lowest with the single-phase rectifier (18.258%), was increased with the rectifier (25.502%) and the 24-peaks rectification (24.217%). Furthermore, there was difference up to content 7.244% to the lowest content 1.285% within three-phase 24-peaks rectification, inverter rectifications, and single-phase rectifier depending on the selectivity of the grid. Drawn from the statistical analysis, there was a similar relationship between the contrast improvement factor and the K factor. As a result, the grid selectivity and the contrast were increased within the single-phase rectifier rather than the constant voltage rectifier.

COMPUTER GAME PLAYING PATTERNS AND PSYCHOPATHOLOGY IN SCHOOL-AGE CHILDREN (학령기 아동의 컴퓨터게임 이용 양상과 정신병리)

  • Lim Seoung-Hu;Jeong Seoung-Shim;Park Jeone-Hwan;Kim Ji-Hae;Hong Sung-Do
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.17 no.1
    • /
    • pp.19-26
    • /
    • 2006
  • Objectives : The object of this study was to examine computer game playing patterns and psychopathologies related to computer game addiction in school-age children. Methods : The subjects were 533 elementary school students (4th to 6th grade) in Kangdonggu, Seoul. We evaluated computer playing patterns of all subjects using computer game playing pattern questionnaire, and determined the risk group of computer game addiction by internet game addiction scale score. We evaluated subscale score of K-CBCL from parents of all subjects, and conducted correlation analysis and logistic regression analysis between computer game addiction and subscale score of K-CBCL. Results : In 488 responders, 10.2% of started playing computer game in preschool age, and 67.2% started at low grade of elementary school. The mean frequency of computer game play per week was 3.66 days. Mean time spent playing computer games per day was 1.89 hours. 'Simply for fun' was the most common reason far playing computer games (40.8%). Male subjects showed statistically significant differences in age of starting computer game, frequency of computer game play per week, reasons for playing computer game and computer game addiction scale scores. There were significant correlations between computer game addiction scale scores and academic performance, somatic complaints, attention problems, and internalizing problems in K-CBCL. But In logistic regression analysis, only attention problems among K-CBCL subscales showed significant predictability to computer game addiction. Conclusion : Upper grade elementary school students experienced computer game playing at the very early age, and spend much time in playing computer games. There were significant correlation and predictability between computer game addiction and attention problems.

  • PDF

The efficacy of denture cleansing agents: A scanning electron microscopic study (수종 의치세정제의 세척 효과에 관한 주사전자현미경적 비교 연구)

  • Yun, Bo-Hyeok;Yun, Mi-Jung;Hur, Jung-Bo;Jeon, Young-Chan;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.57-64
    • /
    • 2011
  • Purpose: The purpose of this study was to compare the cleansing performance of a distilled water, a diluted solution of sodium hypochlorite as a household bleaching cleanser and three alkaline peroxide cleansers in vivo plaque deposits by using scanning electron microscope. Materials and methods: Five individuals were selected from department of the prosthodontics in Pusan National University Hospital, and each of them was inserted with specimens for plaque accumulation in their temporary dentures for 48 hours. The specimens were removed and cleaned by each cleansing agents for 8 hours. Scanning electron micrographs were made from the specimens at a magnification of ${\times}2,000$. A panel of ten persons with a dental or paradental background, but not directly involved in the study, was selected to analyze the photomicrographs to determine which denture cleanser was more effective in removing plaque. Results: Diluted solution of sodium hypochlorite was the most effective at removing plaque following $Polident^{(R)}$, $Cleadent^{(R)}e$, $Bonyplus^{(R)}$ and distilled water in order. But there was no significant difference of cleansing efficacy between diluted solution of sodium hypochlorite and $Polident^{(R)}$, $Polident^{(R)}$ and $Cleadent^{(R)}e$, $Cleadent^{(R)}e$ and $Bonyplus^{(R)}$, respectively (P > .05). Alkaline peroxide cleansers by themselves cannot adequately remove accumulated plaque deposits, especially if the deposits are heavy. Corrosion could be seen on the surface of non-precious alloy specimens immersed in diluted solution of sodium hypochlorite. Conclusion: It is recommended to use of alkaline peroxide type cleansers with brushing whenever possible, since denture cleanliness is often poor due to the relative inefficiency of these cleansers.

Clinical Value of a Desktop Spirometer (HI-801) for Spirometry Screening (선별 검사를 위한 탁상용 폐활량기 (HI-801)의 임상적 유용성에 관한 고찰)

  • Choi, Hye Sook;Choi, Cheon Woong;Park, Myung Jae;Kang, Hong Mo;Yoo, Hong Ji
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.4
    • /
    • pp.276-283
    • /
    • 2007
  • Background: A national health care initiative recommends routine spirometry screening of all smokers over age 45 or patients with respiratory symptoms. In response to the recommendation, new, simple, and inexpensive desktop spirometers for the purpose of promoting widespread spirometric screening were marketed. The performance of these spirometers was evaluated in vivo testing with healthy subjects. However, the clinical setting allows spirometric assessment of various pathologic combinations of flow and volume. Objective: The aim of this study was to compare the accuracy of a desktop spirometer to a standard laboratory spirometer, in a clinical setting with pathologic pulmonary function. Method: In a health check-up center, where screening pulmonary funct test was performed using the HI-801 spirometer. Subjects who revealed the ventilation defect in screening spirometry, performed the spirometry again using the standard Vmax spectra 22d spirometer in a tertiary care hospital pulmonary function laboratory. Pulmonary function test with both spirometer was performed according to the guidelines of the American Thoracic Society. Results: 109 patients were enrolled. Pulmonary function measurements (FVC, $FEV_1$, PEFR, FEF25%-75%) from the HI-801 correlated closely (r=0.94, 0.93, 0.81, 0.84, respectively) with those performed with the Vmax spectra 22d and showed the good limits of agreement and differences between the 2 devices; FVC +0.35 L, $FEV_1$ +0.16 L, PEFR +1.85 L/s, FEF25%-75%-0.13 L/s. With the exception of $FEV_1$, FEF25%-75%, these differences were significant(p<0.05) but small. Conclusion: The HI-801 spirometer is comparable to the standard laboratory spirometer, Vmax spectra 22d, with high accurary for $FEV_1$ and FVC and acceptable differences for clinical use.

Definition of Tumor Volume Based on 18F-Fludeoxyglucose Positron Emission Tomography in Radiation Therapy for Liver Metastases: An Relational Analysis Study between Image Parameters and Image Segmentation Methods (간 전이 암 환자의 18F-FDG PET 기반 종양 영역 정의: 영상 인자와 자동 영상 분할 기법 간의 관계분석)

  • Kim, Heejin;Park, Seungwoo;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Ji, Young Hoon;Yi, Chul-Young;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.99-107
    • /
    • 2013
  • The surgical resection was occurred mainly in liver metastasis before the development of radiation therapy techniques. Recently, Radiation therapy is increased gradually due to the development of radiation dose delivery techniques. 18F-FDG PET image showed better sensitivity and specificity in liver metastasis detection. This image modality is important in the radiation treatment with planning CT for tumor delineation. In this study, we applied automatic image segmentation methods on PET image of liver metastasis and examined the impact of image factors on these methods. We selected the patients who were received the radiation therapy and 18F-FDG PET/CT in Korea Cancer Center Hospital from 2009 to 2012. Then, three kinds of image segmentation methods had been applied; The relative threshold method, the Gradient method and the region growing method. Based on these results, we performed statistical analysis in two directions. 1. comparison of GTV and image segmentation results. 2. performance of regression analysis for relation between image factor affecting image segmentation techniques. The mean volume of GTV was $60.9{\pm}65.9$ cc and the $GTV_{40%}$ was $22.43{\pm}35.27$ cc, and the $GTV_{50%}$ was $10.11{\pm}17.92$ cc, the $GTV_{RG}$ was $32.89{\pm}36.8$4 cc, the $GTV_{GD}$ was $30.34{\pm}35.77$ cc, respectively. The most similar segmentation method with the GTV result was the region growing method. For the quantitative analysis of the image factors which influenced on the region growing method, we used the standardized coefficient ${\beta}$, factors affecting the region growing method show GTV, $TumorSUV_{MAX/MIN}$, $SUV_{max}$, TBR in order. The result of the region growing (automatic segmentation) method showed the most similar result with the CT based GTV and the region growing method was affected by image factors. If we define the tumor volume by the auto image segmentation method which reflect the PET image parameters, more accurate and consistent tumor contouring can be done. And we can irradiate the optimized radiation dose to the cancer, ultimately.

Preliminary Study on the MR Temperature Mapping using Center Array-Sequencing Phase Unwrapping Algorithm (Center Array-Sequencing 위상펼침 기법의 MR 온도영상 적용에 관한 기초연구)

  • Tan, Kee Chin;Kim, Tae-Hyung;Chun, Song-I;Han, Yong-Hee;Choi, Ki-Seung;Lee, Kwang-Sig;Jun, Jae-Ryang;Eun, Choong-Ki;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.131-141
    • /
    • 2008
  • Purpose : To investigate the feasibility and accuracy of Proton Resonance Frequency (PRF) shift based magnetic resonance (MR) temperature mapping utilizing the self-developed center array-sequencing phase unwrapping (PU) method for non-invasive temperature monitoring. Materials and Methods : The computer simulation was done on the PU algorithm for performance evaluation before further application to MR thermometry. The MR experiments were conducted in two approaches namely PU experiment, and temperature mapping experiment based on the PU technique with all the image postprocessing implemented in MATLAB. A 1.5T MR scanner employing a knee coil with $T2^*$ GRE (Gradient Recalled Echo) pulse sequence were used throughout the experiments. Various subjects such as water phantom, orange, and agarose gel phantom were used for the assessment of the self-developed PU algorithm. The MR temperature mapping experiment was initially attempted on the agarose gel phantom only with the application of a custom-made thermoregulating water pump as the heating source. Heat was generated to the phantom via hot water circulation whilst temperature variation was observed with T-type thermocouple. The PU program was implemented on the reconstructed wrapped phase images prior to map the temperature distribution of subjects. As the temperature change is directly proportional to the phase difference map, the absolute temperature could be estimated from the summation of the computed temperature difference with the measured ambient temperature of subjects. Results : The PU technique successfully recovered and removed the phase wrapping artifacts on MR phase images with various subjects by producing a smooth and continuous phase map thus producing a more reliable temperature map. Conclusion : This work presented a rapid, and robust self-developed center array-sequencing PU algorithm feasible for the application of MR temperature mapping according to the PRF phase shift property.

  • PDF

Validation Study for Image Performance of I-131 Using GATE Simulation Program (GATE 시뮬레이션 프로그램을 이용한 I-131의 영상 특성의 타당성에 관한 연구)

  • Baek, Cheol-Ha;Kim, Dae Ho;Lee, Yong-Gu;Lee, Youngjin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.5
    • /
    • pp.133-137
    • /
    • 2017
  • The purpose of this study was to validate for GATE (Geant4 Application for Tomographic Emission) simulation by comparing the results of GATE simulation and experiment in real SPECT system. Futhermore, we want to prove that it is possible that the quantitative research of gamma camera/SPECT imaging for therapeutic radio isotope by using GATE simulation. In this study, the SPECT system on simulation referred to the parameters of Stream-R Forte version 1.2 (Philips Medical System, Best and Heerlen, Netherlands). To understand the I-131 image of gamma camera/SPECT system, we acquired the energy spectrum and measured the full width at half maximum (FWHM) which comes from line spread function (LSF) with and without scatter material in real SPECT system. And to compare with experiment, we also measured the FWHM and acquired the energy spectrum without scatter material in GATE simulation. As a result, without scatter material, the energy peak was almost same location, which are located nearby 364 keV, and other spectrum factors are same tendency in both cases. The FWHM was increased by increasing the distance of source to detector, and the error rate was approximately 3.8%. When we used the line source with scatter material, energy spectrum also indicated similar tendency in both cases. As you confirmed earlier, GATE simulation included real instrument and radioisotope characters for therapeutic radioisotope. Therefore this result that it was possible that various quantitative study for therapeutic radioisotope imaging in gamma camera/SPECT using GATE simulation.