• 제목/요약/키워드: Hospital medical devices

검색결과 317건 처리시간 0.034초

The Short Term Effects of the Decompression (KNX $7000^{(R)}$) and Traction Device on Pain in Patients with Chronic Low Back Pain with or without Radicular Pain (만성 요통 및 하지방사통 환자에서 감압치료(KNX $7000^{(R)}$)와 견인치료의 단기 치료 효과)

  • Park, So-Hyun;Kim, Chul-Seoung;Lee, Dong-Gyu;Ahn, Sang-Ho
    • The Journal of Korean Physical Therapy
    • /
    • 제23권5호
    • /
    • pp.29-34
    • /
    • 2011
  • Purpose: The purpose of this study is to evaluate the short term effects of the traction and decompression device, which is a newly developed domestic medical device, on pain and functional activity in patients with chronic low back pain with or without radicular pain. Methods: Forty patients with chronic low back pain were included and allocated to decompression (n=20) and traction groups (n=20). They received decompression or traction therapy for 20 minutes a day, 3 days per week for two weeks. For evaluating pain and functional activity, a visual analogue scale (VAS) for low back pain and the Oswestry back pain disability index (ODI) were obtained on pre-treatment, and at 6, 12 and 15 days after treatment. Patients'satisfaction levels were measured 15 days after treatment. Results: VAS was significantly decreased at 12 days and 15 days post-treatment compared to pre-treatment in both groups (p<0.05). ODI was significantly decreased at 12 days and 15 days post-treatment compared to pre-treatment in the decompression group (p<0.05). However, there was no significant difference between the two groups in the VAS and ODI scales (p>0.05). Patients' satisfaction levels were significantly higher in the decompression group than in the traction group (p<0.05). Conclusion: These findings suggest that decompression therapy might be effective for increasing functional activity in patients with low back pain and could provide patients with higher satisfaction than traction therapy. This study provided validity data for the therapeutic effects of the decompression device in patients with low back pain and it will be useful for medical cost development and patient education of this device.

Driveline Infections Incidence According to Dressing Methods for Patients with Left Ventricular Assist Device Implantation (좌심실보조장치 수술 환자의 드레싱 방법에 따른 드라이브라인 감염 실태)

  • Choi, Nam Gyung;Choi, Su Jung;Choi, Ji Yeon;Park, Sun Hee
    • Journal of Korean Clinical Nursing Research
    • /
    • 제28권2호
    • /
    • pp.167-176
    • /
    • 2022
  • Purpose: Driveline infection (DLI) is one of the major adverse events of Left Ventricular Assist Device (LVAD). The purpose of this study was to explore the incidence of DLI according to the driveline dressing methods. Methods: This study was a retrospective cohort study that investigated the medical records of 75 patients who implanted LVAD from January 2015 to December 2020 at a hospital in Seoul, Korea. Traditionally, sandwich dressing method was applied until October 2019, after which newly winded dressing method was adopted for driveline dressing to LVAD patients. The outcome variables were compared between sandwich dressing method applied group (n=41) and winded dressing method applied group (n=34). The follow-up period for DLI was 1 year. Results: When compared participants' characteristics, there was no difference between the two groups, except the type of LVAD device. The incidence of DLI was 17.1% in sandwich dressing group, while no infection was found in winded dressing group (p=.011). Conclusion: Although there were difference in the LVAD devices, it is considered that winded dressing contributed to the reduction of DLI. Further research on standardized dressing methods was required for DLI prevention in Korea.

User-friendly Application for operability with HL7 in mobile agent of Ubiquitous Health Environment

  • Lee, JeongHoon;Kwock, DongYeup;Moon, KangNam;sahama, Tony;Kim, Jung-Tae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국해양정보통신학회 2009년도 추계학술대회
    • /
    • pp.866-870
    • /
    • 2009
  • Mobile Health (M-Health) system is a recent term for medical and public health practice supported by mobile devices, such as mobile phones, PDAs, and other wireless devices. Mobile Health system has been successfully establishing at few general hospital in Korea. However, to use diverse devices manufactured by various company cause inoperability, and lack of security disappoints customers often. Although the outstanding health environment, most of hospitals are unavailable to share electronic patient records due to lack of standard protocol to handle the interoperability each other. Health Level 7 (HL7) is the best solution for the problem. In this paper, we will analyse a current M-Health service in terms of security and mobile device, and suggest iPhone for the best device against hospital environment. Also, for keep confidentiality of health information and patient privacy, enhanced security mechanism is introduced. As a consequence, interoperable standard, and most appropriate device for supporting staffs and M-Health performance, and enhanced securirty mechanism will be integrated in order to propose improved M-health model.

  • PDF

Design of a Smart Safety Enforcement System for Patients with Dementia (치매 환자를 위한 지능형 안전강화 시스템 설계)

  • Pi, Kyungjoon;Lee, Kyungmi;Min, Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • 제20권6호
    • /
    • pp.59-64
    • /
    • 2020
  • As the number of elderly people rapidly increases, needs of patient safety monitoring system also increases in indoor and outdoor medical facilities. With developing technologies related to sensors and information and communication technology, various dementia patient monitoring systems have been proposed. However, previous studies that depend on wearable devices provides limited functionalities. In this paper, we designed an integrated system that includes smart devices to monitor patient's status, user friendly UI/UX, and interaction with hospital information system. Medical teams and carers can receive satus of each patient in real-time and trace the location of dementia patients outdoor as well as indoor by using the proposed system.

A Study on Quality Assurance(QA) Guideline for Diagnostic Monitor (판독용 모니터 정도관리 항목 및 시행기준안 개발 연구)

  • Son, Gi-Gyeong;Sung, Dong-Wook;Jung, Hae-Jo;Jeong, Jae-Ho;Kang, Hee-Doo;Shin, Jin-Ho;Lee, Sun-Geun;Kim, Yong-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • 제9권1호
    • /
    • pp.53-65
    • /
    • 2007
  • PACS has been run at the Kyung Hee University Medical Center(KHMC) since 2001, and the installation and operation of PACS have contributed to automation and quantification of KHMC's medical environment During these five years our greatest concern is how to make our own guiding principle of diagnostic monitor QA which is adapted to international standards. In accordance with the terms of 'KHMC QA Guideline', 'AAPM TG18', 'SMPTE RP133', 'DICOM Part14', 'DIN V 6868-57', 'JESRA X-0093', 'JIS Z4752-2-5' and 'KCARE', concern about quality assurance of medical images are on the increase. With the investigation of acceptance testing and quality control of international standards for medical display devices, and data collection and analysis for recommended guideline, it is reported that acceptance testing(quality control), including geometrical distortion, display reflection, luminance response, luminance uniformity, display resolution, display noise, veiling glare and color chromaticity being adequate and effective to domestic hospital environments for medical display devices and assessment methods according to each performance. Accordingly, KHMC classified the checkpoint items by period, at the time of monitor setting, monthly, quarterly, half-yearly and annually. Periodic classification of checkpoint items for monitor QA makes a good guideline for image QA/QC and useful guideline for persistent good quality of monitor.

  • PDF

A Web-based Survey for Assessment of Korean Medical Treatment Clinical Practice Patterns for Temporomandibular Disorders (턱관절 질환의 한의진료 임상현황조사를 위한 웹기반 설문조사)

  • Kim, Chang-Eun;Do, Ho-Jeong;Song, Hyun-Seop;Shin, Jae-Kwon;Lee, Won-Jun;Kim, Jong-Ho;Lee, Keun-Jae;Yoon, Young-Suk;Kim, No-Hyeon;Suh, Chang-Yong;Lee, Yoon-Jae;Kim, Mi-Riong;Cho, Jae-Heung;Kwon, Mi-Jung;Ha, In-Hyuk
    • Journal of Korean Medicine Rehabilitation
    • /
    • 제28권1호
    • /
    • pp.73-84
    • /
    • 2018
  • Objectives While Temporomandibular disorders (TMD) is highly prevalent in Korea, studies examining its Korean medical treatment are currently lacking. The aim of this study was to assess current Korean medical treatment practice patterns for TMD. Methods A preliminary questionnaire was developed to investigate current practice patterns of TMD treatment and underwent further revision through external review. The final questionnaire was distributed as a web-based survey to 18,289 potential respondents by email. Results The response rate was 2.23%. Most participants replied that they received multiple Korean medicine interventions for TMD treatment consisting of such methods as acupuncture, chuna manipulation, electroacupuncture. The percentage of treatment services among uncovered services, which need to be covered by national health insurance was high in the order of pharmacopuncture, chuna manipulation, and herbal medicine. The most commonly used diagnostic examination tools for TMD was Physical examination and next was Imaging diagnosis. The frequency of TMD treatment was the highest at 2~3 times per week (76%) and the period was from 4 to 12 weeks (63%). Conclusions This survey study helps determine current practice patterns of TMD, and recognizes the need for use of diagnostic devices in TMD treatment. These results are further anticipated to provide basic data for clinical practice guide lines (CPGs).

Developing Management System of Medical Image Information with USB 2.0 (USB 2.0을 활용한 의료 영상정보 관리시스템 개발)

  • Choi, Jung-Sang
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • 제29권2호
    • /
    • pp.51-57
    • /
    • 2006
  • This study is concerned with image information management system for small scale hospital. We intended to developing image management system which is used of the existing analog devices such as medical camera, supersonic analyser, endoscope etc. We developed a video in interface board based USB 2.0 for handling image in real time. It is capable of transmitting image input signal like as NTSC, PAL to personal computer through USB 2.0. The developed the board of 40 speeds compared with the exiting system based USB 1.0. Especially the developed system is very helpful for small hospital like as dental clinic, because it is easy and convenient to manage image information without expert. So it will provide reduction of time and cost for handling image information(collecting, saving, retrieval, transmitting image).

The Usefulness of a Wearable Device in Daily Physical Activity Monitoring for the Hospitalized Patients Undergoing Lumbar Surgery

  • Kim, Dong Hwan;Nam, Kyoung Hyup;Choi, Byung Kwan;Han, In Ho;Jeon, Tae Jin;Park, Se Young
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권5호
    • /
    • pp.561-566
    • /
    • 2019
  • Objective : Functional outcomes have traditionally been evaluated and compared using subjective surveys, such as visual analog scores (VAS), the Oswestry disability index (ODI), and Short Form-36 (SF-36), to assess symptoms and quality of life. However, these surveys are limited by their subjective natures and inherent bias caused by differences in patient perceptions of symptoms. The Fitbit $Charge^{(R)}$ (Fitbit Inc., San Francisco, CA, USA) provides accurate and objective measures of physical activity. The use of this device in patients after laminectomy would provide objective physical measures that define ambulatory function, activity level, and degree of recovery. Therefore, the present study was conducted to identify relationships between the number of steps taken by patients per day and VAS pain scores, prognoses, and postoperative functional outcomes. Methods : We prospectively investigated 22 consecutive patients that underwent laminectomy for spinal stenosis or a herniated lumbar disc between June 2015 and April 2016 by the same surgeon. When patients were admitted for surgery and first visited after surgery, preoperative and postoperative functional scores were recorded using VAS scores, ODI scores, and SF-36. The VAS scores and physical activities were recorded daily from postoperative day (POD) 1 to POD 7. The relationship between daily VAS scores and daily physical activities were investigated by simple correlation analysis and the relationship between mean number of steps taken and ODI scores after surgery was subjected to simple regression analysis. In addition, Wilcoxon's signed-rank test was used to investigate the significance of pre-to-postoperative differences in VAS, ODI, and SF-36 scores. Results : Pre-to-postoperative VAS (p<0.001), ODI (p<0.001), SF-36 mental composite scores (p=0.009), and SF-36 physical composite scores (p<0.001) scores were found to be significantly different. Numbers of steps taken from POD 1 to POD 7 were negatively correlated with daily VAS scores (r=-0.981, p<0.001). In addition, the mean number of steps from POD 3 to POD 7 and the decrease in ODI conducted one month after surgery were statistically significant (p=0.029). Conclusion : Wearable devices are not only being used increasingly by consumers as lifestyle devices, but are also progressively being used in the medical area. This is the first study to demonstrate the usefulness of a wearable device for checking patient physical activity and predicting pain and prognosis after laminectomy. Based on our experience, the wearable device used to provide measures of physical activity in the present study has the potential to provide objective information on pain severity and prognosis.

Strategies for dental aspiration and ingestion accidents that can lead to serious complications: a report of three cases and a review of articles

  • Shin, Youngjin;Hong, Sung ok;Kim, Rayeon;Jee, Yu-jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제48권5호
    • /
    • pp.318-325
    • /
    • 2022
  • Population aging and the usage of small devices in implant prosthetic procedures have led to many incidents of dental aspiration and ingestion. Various preventive measures have been introduced to prevent these accidents. However, accidents can occur at any time. Dental aspiration and ingestion lead to fatal consequences if the issue is not promptly and appropriately dealt with. Preparing a collaborative system for dealing with accidents before they occur can prevent further sequelae. This study involves ingestion and aspiration accidents that occurred during dental treatment: two ingestion cases and one aspiration case. All dental foreign bodies were removed according to the guidelines presented in our review. With the cooperation of other medical departments, the issues were quickly resolved. Simple and accurate protocols should be provided to all dentists and dental staff to respond to such dental emergencies. In addition, collaboration among other medical departments should be established before any accidental ingestion and aspiration events occur.

Isocenter Check and QA of Tactic Radiosurgery Devices Using EPID (EPID를 이용한 정위적방사선수술의 중심점 검사에 대한 연구)

  • Shin, Kyo Chul;Choi, Sang Gyu;Kim, Jung Kee;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • 제25권4호
    • /
    • pp.281-287
    • /
    • 2014
  • The Winston Lutz test, which checks the accuracy of the isocenter for stereotactic radiosurgery (SRS), was performed with the commercial electronic portal imaging device (EPID). The usual Winston Lutz test with film was also performed for comparison with the test with EPID. The maximum difference in isocenter between the two methods was 0.32 mm. The Winston Lutz test using EPID is practical as it can reduce time and avoid human errors compared to the test with film.