• Title/Summary/Keyword: Hospital medical devices

Search Result 317, Processing Time 0.025 seconds

Development of shielding device for bremsstrahlung radiation from Y-90 microspheres (Y-90 microsphere 로부터 생성되는 제동복사선의 차폐를 위한 차폐체 개발 연구)

  • Park, Jun Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.50-53
    • /
    • 2019
  • Purpose Yttrium-90 (Y-90) is high-energy beta emitters ($E{\beta}$, max = 2.28 MeV) with the mean penetration depth of 2.5 mm in tissue. Radioactive microspheres containing Y-90 is widely used for the transarterial radioembolization of hepatocellular carcinoma. However, bremsstrahlung radiation from Y-90 can cause the external radiation exposure to medical staff who handle the Y-90 microspheres. In this study, shielding device for Y-90 microspheres was developed to minimize the external radiation exposure. Materials and Methods Y-90 microsphere shielding device was made from 6 mm thicknesses of tungsten including the lead glass window. Radiation shielding ability of Y-90 microsphere shielding device was evaluated using 4 GBq of $SIR-Spheres^{(R)}$ Y-90 microspheres. The bremsstrahlung radiation was measured using radiation survey meter. Results The mean radiation dose of Y-90 microspheres in acrylic shield was $261.7{\pm}2.3{\mu}Sv/h$ (n=5) at 10 cm away from the shield. With the additional tungsten shielding device, it was $23.7{\pm}1.3{\mu}Sv/h$ (n=5). Thus, the bremsstrahlung radiation dose was decreased by 90.9%. At 50 cm away from the shield, bremsstrahlung radiation was reduced by 89.2% after using tungsten shielding device. Conclusion During the preparation and radioembolization of Y-90 microsphere, medical staff are exposed to external radiation. In this study, we demonstrated that the use of tungsten shielding device devices significantly reduced the amount of bremsstrahlung radiation. Y-90 microsphere tungsten shielding device can be highly effective in reducing the bremsstrahlung radiation.

A Study on Regulations Through Analysis of the Status of Radiation Workers and Related Workers and Satisfaction Survey in the Radiology Department (방사선작업종사자 및 방사선관계종사자의 현황 분석과 교내 실습 만족도 조사를 통한 방사선(학)과의 규제에 대한 고찰)

  • Jung, Hyunseo;Lee, Yong-Ki;Ahn, Sung-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.327-334
    • /
    • 2022
  • In this study, the purpose of this study was to conduct a basic study on the effectiveness and feasibility of the regulation of the Nuclear Safety Act for the department of radiology by examining the questionnaire on the satisfaction of on-campus practice while attending the department of radiology and the current status of radiation workers and radiation related workers. As for the satisfaction of the workers who were designated as frequent visitors while attending the department of radiology and did not handle and operate the radiation generator during on-campus training, 34.62% of the workers answered 'not satisfied'. On the other hand, 50% of workers who were designated as radiation workers while attending school or who were enrolled in school before the regulation of the nuclear safety act and handled and operated radiation generators were 'satisfied' at 50%. In addition, the annual exposure dose of radiation workers in educational institutions was found to be less than 0.05 mSv. If you look at the trends of radiation workers and radiation workers, it can be seen that students who graduate from the Department of Radiology find the most employment in the field dealing with diagnostic radiation generators registered as radiation workers among medical institutions. Therefore, by easing the regulations of the current Nuclear Safety Act or by amending the medical act and the rules on the safety management of diagnostic radiation generating devices, etc. It is presumed that something is necessary.

A Preliminary Study for Evaluating on Demonstration Project of Community-based Home Health Care Nursing Services by the Seoul Nurses Association (지역사회중심 가정간호 시범사업 성과평가를 위한 기초연구- 서울시 간호사회 주관 -)

  • 유호신;이소우;문희자;황나미;박성애;박정숙;최행지;정기순;한상애
    • Journal of Korean Academy of Nursing
    • /
    • v.30 no.6
    • /
    • pp.1488-1502
    • /
    • 2000
  • This study, based on current home nursing services, aims at promoting measures for establishing a community-based home nursing system derived from the pilot home nursing demonstration project conducted by the Seoul Nurses Association. The study was based on an analysis of home nursing records from march 1993 to December 1999. The following is a summary analysis, based on individual characteristics of the patients, the organization, which recommended the service for their patients and personnel services. 1. The service has been used by many elderly people 60years of age or older(66.4%). and married people(60.9%). The average number of visits by service personnel for patients of city government was 23.5. This is 2.5 times as many visits by general patients. General patients(20.2%) had only one visit from service personnel, while 65.5% of patients of city government had 10 or more visits. Particularly, for government recommended patients, 72.7% of the patients were recommended by nurses, while only 21.9% where referred to the services by doctors. The main focus of a home nursing service was to maintain present health status (53.4%), and hospice(11.6%). Also to increase hospital-based home nursing services focused on recovery(55.9%) and maintain present health conditions (19.0%). 2. For general patients, 42.0% of patients were suffering from problems related to CVA, 11.3% from high blood pressure, and for patients referred from city, 21.2% from skeletal muscular disease. Results of home nursing services 29.4% of patients were able to recover or maintain their health status, but 48.9% of the patients died. Another main point of community-based home nursing services is medication(6.7%), other basic nursing services(6.1%), special treatment, instructions on how to use medical devices(5.9%), change of physical posture(4.6%), and training on changing physical positions(4.7%). As mentioned above there were some differences between the characteristics of patients who used the pilot home nursing service conducted by the Seoul Nurses Association and those hospital-based service users. The results are believed to be useful to support a community-based home nursing service model. Particularly, patients under medical supervision and patients recommended by government-run health clinics show a higher frequency and longer use of home nursing services compared to general patients or hospital-based home nursing service users. According to the study, nurses accounted for a large number of recommendations for home nursing services. Many patients with CVA, high blood pressure, skeletal muscular disease and bedsores used community-based home nursing services, while others used the service for minor treatments or maintaining their current health status. Based on the study, the researchers make several suggestions to establish a community- based home nursing service system. First, different ways of setting up a community-based home nursing system have to be mapped out based on the evaluation of the pilot home nursing service conducted by the Seoul Nurses Association. Secondly, a new, community-based, home health care nursing service model, and reimbursement payment system have to be developed. This is based on the outcome of the analysis, and implemented policy. Accordingly, efforts are needed to develop a community- based home nursing system with an intermediary role to promote the visiting nursing services of government-run health centers.

  • PDF

Clinical Analysis of 500 Cases of Coronary Artery Bypass Grafting (관상동맥 우회술 500례의 임상적 고찰)

  • Shin, Yoon-Cheol;Kim, Ki-Bong;Ahn, Hyuk;Chae, Hurn;Rho, Joon-Ryang;Suh, Kyung-Phill
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.525-531
    • /
    • 1999
  • Background: We analyzed five hundred patients who underwent either isolated or concomitant coronary artery bypass grafting(CABG) between November 1981 and June 1997. Material and Method: There were 330 males and 170 females with a mean age of 57.4$\pm$8.9 years. To evaluate the preoperative status, we performed electrocardiograghy, echocardiography, MIBI scan, Duplex sonogram, common blood test including CK and LDH and coronary angiography. Result: Preoperative clinical diagnoses were unstable angina in 282 (56.4%), stable angina in 141 (28.2%), postinfarction angina in 58 (11.6%), acute myocardial infarction in 8 (1.6%), variant angina in 7 (1.4%) and failed percutaneous transluminal coronary angioplasty in 4 (0.8%) patients. Preoperative angiographic diagnoses were three-vessel disease in 263 (52.6%), two-vessel disease in 93 (18.6%), one-vessel disease in 71 (14.2%), left main disease in 68 (13.6%), and others in 5 (1.0%) patients. Patients had various risk factors for coronary disease, and the frequency of the risk factors such as hypertension, diabetes and smoking showed increasing tendency year by year. We used saphenous vein grafts in 1143, internal thoracic artery grafts in 442, radial artery graft in 17, and gastroepiploic artery graft in 1 anastomosis. The mean number of grafts was 3.2$\pm$1.2 per patient. Concomitant operations were prosthetic valve replacement or valvuloplasty in 31, coronary endarterectomy and angioplasty in 27, left main coronary angioplasty in 13, carotid endarterectomy in 5, and neurologic problems, bleeding, and perioperative myocardial infarction. The mean follow-up period was 25$\pm$23 months and there were 5 cases of reoperation. Conclusion: We hope that the surgical results would improve with the accumulation of experience, application of new myocardial protection technique, and timely intervention of mechanical assisted devices.

  • PDF

Skin Damage Sustained During Head-and-Neck and Shoulder Radiotherapy Due to the Curvature of Skin and the Use of Immobilization Mask (머리-목 그리고 어깨의 방사선 치료 시 피부곡면과 고정장치로 인한 피부손상연구)

  • Kim, Soo-Kil;Jeung, Tae-Sig;Lim, Sang-Wook;Park, Yeong-Mouk;Park, Dahl
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.86-92
    • /
    • 2010
  • The purpose of this study was to measure curvature contour skin dose using radiochromic film and TLD for a conventional open field. We also attempted to quantify the degradation of skin sparing associated with use of immobilization devices for high energy photon beams and to calculate the skin dose with a help of Monte Carlo (MC) simulation. To simulate head-and-neck and shoulder treatment, a cylindrical solid water phantom 11 cm in diameter was irradiated with 6 MV x-rays using $40{\times}40\;cm^2$ field at 100 cm source axis distance (SAD) to the center of the phantom. Aquaplastic mesh mask was placed on the surface of the cylindrical phantom that mimicked relevant clinical situations. The skin dose profile was obtained by taking measurements from $0^{\circ}$ to $360^{\circ}$ around the circumference of the cylindrical phantom. The skin doses obtained from radiochromic film were found to be 47% of the maximum dose of $D_{max}$ at the $0^{\circ}$ beam entry position and 61% at the $90^{\circ}$ oblique beam position without the mask. Using the mask (1.5 mm), the skin dose received was 59% at $0^{\circ}$ incidence and 78% at $80^{\circ}$ incidence. Skin dose results were also gathered using thin thermoluminescent dosimeters (TLD). With the mask, the skin dose was 66% at $0^{\circ}$ incidence and 80% at $80^{\circ}$ incidence. This method with the mask revealed the similar pattern as film measurement. For the treatments of the head-and-neck and shoulder regions in which immobilization mask was used, skin doses at around tangential angle were nearly the same as the prescription dose. When a sloping skin contour is encountered, skin doses may be abated using thinner and more perforated immoblization devices which should still maintain immoblization.

An Exploratory Study on Smart Wearable and Game Service Design for U-Silver Generation: U-Hospital Solution for the Induction of Interest to Carry Out Personalized Exercise Prescription (U-실버세대를 위한 스마트 웨어러블 및 연동 게임의 서비스 디자인 방안 탐색: 개인 맞춤형 운동처방 실행을 위한 흥미 유도 목적의 U-Hospital 솔루션)

  • Park, Su Youn;Lee, Joo Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.22 no.1
    • /
    • pp.23-34
    • /
    • 2019
  • The U-Healthcare era has evolved with the development of the Internet of things (IoT) in the early stages of being connected as a society. Already, many changes such as increased well-being and the extension of human life are becoming evident across cultures. Korea entered the growing group of aging societies in 2017, and its silver industry is expected to grow rapidly by adopting the IoT of a super-connected society. In particular, the senior shift phenomenon has resulted in increased interest in the promotion of the health and well-being of the emergent silver generation which, unlike the existing silver generation, is highly active and wields great economic power. This study conducted in-depth interviews to investigate the characteristics of the new silver generation, and to develop the design for a wearable serious game that intends to boost the interest of the elderly in exercise and fitness activities according to their personalized physical training regimes as prescribed by the U-Hospital service. The usage scenario of this wearable serious game for the 'U-silver generation' is derived from social necessity. Medical professionals can utilize this technology to conduct health examinations and to monitor the rehabilitation of senior patients. The elderly can also use this tool to request checkups or to interface with their healthcare providers. The wearable serious game is further aimed at mitigating concerns about the deterioration of the physical functions of the silver generation by applying personalized exercise prescriptions. The present investigation revealed that it is necessary to merge the on / off line community activities to meet the silver generation's daily needs for connection and friendship. Further, the sustainability of the serious game must be enhanced through the inculcation of a sense of accomplishment as a player rises through the levels of the game. The proposed wearable serious game is designed specifically for the silver generation that is inexperienced in using digital devices: simple game rules are applied to a familiar interface grounded on the gourmet travels preferred by the target players to increase usability.

Geometric Calibration of Cone-beam CT System for Image Guided Proton Therapy (영상유도 양성자치료를 위한 콘빔 CT 재구성 알고리즘: 기하학적 보정방법에 관한 연구)

  • Kim, Jin-Sung;Cho, Min-Kook;Cho, Young-Bin;Youn, Han-Bean;Kim, Ho-Kyung;Yoon, Myoung-Geun;Shin, Dong-Ho;Lee, Se-Byeung;Lee, Re-Na;Park, Sung-Yong;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.209-218
    • /
    • 2008
  • According to improved radiation therapy technology such as IMRT and proton therapy, the accuracy of patient alignment system is more emphasized and IGRT is dominated research field in radiation oncology. We proposed to study the feasibility of cone-beam CT system using simple x-ray imaging systems for image guided proton therapy at National Cancer Center. 180 projection views ($2,304{\times}3,200$, 14 bit with 127 ${\mu}m$ pixel pitch) for the geometrical calibration phantom and humanoid phantoms (skull, abdomen) were acquired with $2^{\circ}$ step angle using x-ray imaging system of proton therapy gantry room ($360^{\circ}$ for 1 rotation). The geometrical calibration was performed for misalignments between the x-ray source and the flat-panel detector, such as distances and slanted angle using available algorithm. With the geometrically calibrated projection view, Feldkamp cone-beam algorithm using Ram-Lak filter was implemented for CBCT reconstruction images for skull and abdomen phantom. The distance from x-ray source to the gantry isocenter, the distance from the flat panel to the isocenter were calculated as 1,517.5 mm, 591.12 mm and the rotated angle of flat panel detector around x-ray beam axis was considered as $0.25^{\circ}$. It was observed that the blurring artifacts, originated from the rotation of the detector, in the reconstructed toomographs were significantly reduced after the geometrical calibration. The demonstrated CBCT images for the skull and abdomen phantoms are very promising. We performed the geometrical calibration of the large gantry rotation system with simple x-ray imaging devices for CBCT reconstruction. The CBCT system for proton therapy will be used as a main patient alignment system for image guided proton therapy.

  • PDF

Development of Porcine Pericardial Heterograft for Clinical Application (Microscopic Analysis of Various Fixation Methods) (돼지의 심낭, 판막을 이용한 이종이식 보철편의 개발(고정 방법에 따른 조직학적 분석))

  • Kim, Kwan-Chang;Choi, Chang-Hyu;Lee, Chang-Ha;Lee, Chul;Oh, Sam-Sae;Park, Seong-Sik;Kim, Woong-Han;Kim, Kyung-Hwan;Kim, Yong-Jiin
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.295-304
    • /
    • 2008
  • Background: Various experimental trials for the development of bioprosthetic devices are actively underway, secondary to the limited supply of autologous and homograft tissue to treat cardiac diseases. In this study, porcine bioprostheses that were treated with glutaraldehyde (GA), ethanol, or sodium dodecylsulfate (SDS) were examined with light microscopy and transmission electron microscopy for mechanical and physical imperfections before implantation, Material and Method: 1) Porcine pericardium, aortic valve, and pulmonary valve were examined using light microscopy and JEM-100CX II transmission electron microscopy, then compared with human pericardium and commercially produced heterografts. 2) Sections from six treated groups (GA-Ethanol, Ethanol-GA, SDS only, SDS-GA, Ethanol-SDS-GA and SDS-Ethanol-GA) were observed using the same methods. Result: 1) Porcine pericardium was composed of a serosal layer, fibrosa, and epicardial connective tissue. Treatment with GA, ethanol, or SDS had little influence on the collagen skeleton of porcine pericardium, except in the case of SDS pre-treatment. There was no alteration in the collagen skeleton of the porcine pericardium compared to commercially produced heterografts. 2) Porcine aortic valve was composed of lamina fibrosa, lamina spongiosa, and lamina ventricularis. Treatment with GA, ethanol, or SDS had little influence on these three layers and the collagen skeleton of porcine aortic valve, except in the case of SDS pre-treatment. There were no alterations in the three layers or the collagen. skeleton of porcine aortic valve compared to commercially produced heterografts. Conclusion: There was little physical and mechanical damage incurred in porcine bioprosthesis structures during various glutaraldehyde fixation processes combined with anti-calcification or decellularization treatments. However, SDS treatment preceding GA fixation changed the collagen fibers into a slightly condensed form, which degraded during transmission electron micrograph. The optimal methods and conditions for sodium dodecylsulfate (SDS) treatment need to be modified.

Comparison about adverse drug reaction report forms among Asian's countries using herbal medicine (한약을 사용하는 아시아권 국가의 유해사례 보고 양식에 관한 비교 연구)

  • Sun, Seung-Ho;Lee, Eun-Kyoung;Jang, Bo-Hyoung;Park, Sunju;Go, Ho-Yeon;Jeon, Chan-Yong;Ko, Seong-Gyu
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.19 no.3
    • /
    • pp.91-102
    • /
    • 2015
  • Objective : The purpose of this study is to find out the possibility of application to herbal medicine's report form for adverse drug reaction (ADR) by reviewing and analyzing Asian countries's ADR report forms. Method : We investigated, compared, and analyzed ADR report forms (ADR-RF) of Asian countries's ADR institutions (ACAI), such as, Korea institute of drug safety & risk management and Dongguk university Ilsan oriental hospital (DUIOH) in Korea, national center for ADR monintoring (NCAM) in China, pharmaceuticals and medical devices agency (PMDA) in Japan, Ministry of Health and Welfare (MOHW) in Taiwan, and drug office, department of health, the government of the Hong Kong special administrative region (GHKSAR) in Hong Kong. Results : ADR-RF for ACAI included common contents, such as, patients information (name(initial), gender, age, weight), adverse event (AE)'s report information (Recognition and report for AE occurrence, first or follow up report, Severe AE), the detailed information of AE (the title of AE, onset & closing date of AE symptoms, the progress & results detailed test of AE), the information of AE's medicine (the types of medicine, product name, ingredient name, suspected or combination drug, single dose & frequency, dosage form, administration route, dealing for AE-suspected medicine), and AE reporter's information (reporter's information, institution's information). Taiwan had ADR-RF and the department exclusively for herbal medicine (HM), but others (except DUIOH) had not only no ADR report form but also contents for HM. Conclusion : ADR-RF for HM have to include the common contents of ACAI at least, as well as HM information related to ADR, such as the title, composition and types of HM, history related to HM's ADR, and the contents of drug-induced liver injury and so on. In addition, the main department of government for HM's ADR will be needed.

Applicability and Safety of in Vitro Skin Expansion Using a Skin Bioreactor: A Clinical Trial

  • Jeong, Cheol;Chung, Ho Yun;Lim, Hyun Ju;Lee, Jeong Woo;Choi, Kang Young;Yang, Jung Dug;Cho, Byung Chae;Lim, Jeong Ok;Yoo, James J.;Lee, Sang Jin;Atala, Anthony J.
    • Archives of Plastic Surgery
    • /
    • v.41 no.6
    • /
    • pp.661-667
    • /
    • 2014
  • Background Tissue expansion is an effective and valuable technique for the reconstruction of large skin lesions and scars. This study aimed to evaluate the applicability and safety of a newly designed skin expanding bioreactor system for maximizing the graft area and minimizing the donor site area. Methods A computer-controlled biaxial skin bioreactor system was used to expand skin in two directions while the culture media was changed daily. The aim was to achieve an expansion speed that enabled the skin to reach twice its original area in two weeks or less. Skin expansion and subsequent grafting were performed for 10 patients, and each patient was followed for 6 months postoperatively for clinical evaluation. Scar evaluation was performed through visual assessment and by using photos. Results The average skin expansion rate was $10.54%{\pm}6.25%$; take rate, $88.89%{\pm}11.39%$; and contraction rate, $4.2%{\pm}2.28%$ after 6 months. Evaluation of the donor and recipient sites by medical specialists resulted in an average score of 3.5 (out of a potential maximum of 5) at 3 months, and 3.9 at 6 months. The average score for patient satisfaction of the donor site was 6.2 (out of a potential maximum of 10), and an average score of 5.2 was noted for the recipient site. Histological examination performed before and after the skin expansion revealed an increase in porosity of the dermal layer. Conclusions This study confirmed the safety and applicability of the in vitro skin bioreactor, and further studies are needed to develop methods for increasing the skin expansion rate.