• 제목/요약/키워드: Hospital guide

검색결과 442건 처리시간 0.034초

동영상과 책자를 이용한 교육이 환자의 입원생활 이해도와 만족도에 미치는 영향 (The Effect of In-patient Guide Movie and Booklet Programs on Understanding of Hospital Life and Satisfaction with the Programs)

  • 정현철
    • 간호행정학회지
    • /
    • 제14권1호
    • /
    • pp.45-50
    • /
    • 2008
  • Purpose: This study was intended to determine how an in-patient guide movie enhanced the understanding of hospital life. Method: A non-equivalent control group post-test design was used for the study. The experimental group was allowed to watch the in-patient guide movie. The in-patient guide booklets were given to the control group for reading. The understanding and satisfaction of the respective programs were surveyed with questionnaires. The data was analyzed using SPSS. Result: The movie watching experimental group had better understanding on the hospital life than the booklet reading control group. The movie watching group had more satisfaction with the guide program than the booklet reading group. The understanding of the hospital life and satisfaction with the program had relevance. Conclusion: This study suggests that the in-patient guide movie would help the would-be in-patients understand and adapt to the hospital life better. Therefore, the in-patient guide movie is considered to be a useful medium to educate in-patients for their hospital life.

  • PDF

경피적 관상동맥 확장 성형술 도중 우관상동맥 뒤가쪽가지에서 발생한 유도철사 부러짐 (Guide wire fracture during percutaneous coronary intervention)

  • 김학로;임태훈;김병철;이호준;오홍근;주현식;김태진;김용복
    • Journal of Yeungnam Medical Science
    • /
    • 제33권1호
    • /
    • pp.52-55
    • /
    • 2016
  • Guide wire fracture during percutaneous coronary intervention (PCI) is rare. It can cause fatal complications such as thrombus formation, embolization, and perforation. Guide wire fracture could occur during intervention for severely calcified stenotic lesions, and rarely from distal small branches of stenotic lesions. There are several methods for its management depending on the material character, position, length of the remnant, and the patient's condition. If percutaneous retrieval was not achieved, the surgical procedure should be considered for prevention of potential risks, although the remnant guide wire does not usually cause complications. We experienced a patient with a guide wire fracture during PCI, and managed to prevent its complications through surgical removal of the remnant wire. We report this case here.

입원환자의 의료질 향상(QI)을 위한 입원생활 안내문의 효과 (A Study in the Medical Service Improvement at University Hospitals with Concentration upon Life in Hospital Guide)

  • 박선경;한상숙;백승남
    • 동서간호학연구지
    • /
    • 제9권1호
    • /
    • pp.74-82
    • /
    • 2004
  • Purpose: This study has been conducted as a quality improvement activity in order to confirm the assessment of patients, their guardians and nurses by providing them with a Life in Hospital Guide. Method: Nursing with Life in Hospital Guide provision was conducted at an University Hospital with patients admitted within 5 days or less and their guardians, a control group of 375 persons and a comparison group of 372 persons, and the data have been collected from the 26th of May to the 10th of October 2003. A Life in Hospital Guide, in the form of a leaflet, that contained useful information such as meals, facilities, car parking, documents, linen products etc, was used. The collected data have been analysed using SPSS windows programme 11.0 for percentage, $X^2$-test, and t-test. Result: The comparison group who were provided with a Life in Hospital Guide will know better about the articulars needed to live in hospital than the control group who were not,' the average of the comparison group (4.04) was higher than the control group (3.04), which is a significant difference (t=-27.06, p=.000). Conclusion: As a results of this study, it was confirmed that life in hospital guidance through a leaflet each as a quality improvement activity, are effective.

  • PDF

Mixed reality visualization in shoulder arthroplasty: is it better than traditional preoperative planning software?

  • Sejla Abdic;Nicholas J. Van Osch;Daniel G. Langohr;James A. Johnson;George S. Athwal
    • Clinics in Shoulder and Elbow
    • /
    • 제26권2호
    • /
    • pp.117-125
    • /
    • 2023
  • Background: Preoperative traditional software planning (TSP) is a method used to assist surgeons with implant selection and glenoid guide-pin insertion in shoulder arthroplasty. Mixed reality (MR) is a new technology that uses digital holograms of the preoperative plan and guide-pin trajectory projected into the operative field. The purpose of this study was to compare TSP to MR in a simulated surgical environment involving insertion of guide-pins into models of severely deformed glenoids. Methods: Eight surgeons inserted guide-pins into eight randomized three-dimensional-printed severely eroded glenoid models in a simulated surgical environment using either TSP or MR. In total, 128 glenoid models were used and statistically compared. The outcomes compared between techniques included procedural time, difference in guide-pin start point, difference in version and inclination, and surgeon confidence via a confidence rating scale. Results: When comparing traditional preoperative software planning to MR visualization as techniques to assist surgeons in glenoid guide pin insertion, there were no statistically significant differences in terms of mean procedure time (P=0.634), glenoid start-point (TSP=2.2±0.2 mm, MR=2.1±0.1 mm; P=0.760), guide-pin orientation (P=0.586), or confidence rating score (P=0.850). Conclusions: The results demonstrate that there were no significant differences between traditional preoperative software planning and MR visualization for guide-pin placement into models of eroded glenoids. A perceived benefit of MR is the real-time intraoperative visibility of the surgical plan and the patient's anatomy; however, this did not translate into decreased procedural time or improved guide-pin position.

Genioplasty using a simple CAD/CAM (computer-aided design and computer-aided manufacturing) surgical guide

  • Lim, Se-Ho;Kim, Moon-Key;Kang, Sang-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제37권
    • /
    • pp.44.1-44.6
    • /
    • 2015
  • Background: The present study introduces the design and fabrication of a simple surgical guide with which to perform genioplasty. Methods: A three-dimensional reconstruction of the patient's cranio-maxilla region was built, with a dentofacial skeletal model, then derived from CT DICOM data. A surgical simulation was performed on the maxilla and mandible, using three-dimensional cephalometry. We then simulated a full genioplasty, in silico, using the three-dimensional (3D) model of the mandible, according to the final surgical treatment plan. The simulation allowed us to design a surgical guide for genioplasty, which was then computer-rendered and 3D-printed. The manufactured surgical device was ultimately used in an actual genioplasty to guide the osteotomy and to move the cut bone segment to the intended location. Results: We successfully performed the osteotomy, as planned during a genioplasty, using the computer-aided design and computer-aided manufacturing (CAD/CAM) surgical guide that we initially designed and tested using simulated surgery. Conclusions: The surgical guide that we developed proved to be a simple and practical tool with which to assist the surgeon in accurately cutting and removing bone segments, during a genioplasty surgery, as preoperatively planned during 3D surgical simulations.

Spiritual Care Guide in HospiceㆍPalliative Care

  • Kyung-Ah Kang;Do-Bong Kim;Su-Jin Koh;Myung-Hee Park;Hye Yoon Park;Deuk Hyoung Yoon;Soo-Jin Yoon;Su-Jeong Lee;JI-Eun Choi;Hyoung-Suk Han;Jiyoung Chun
    • Journal of Hospice and Palliative Care
    • /
    • 제26권4호
    • /
    • pp.149-159
    • /
    • 2023
  • The Spiritual Care Guide in HospiceㆍPalliative Care is evidence-based and focuses on the universal and integral aspects of human spirituality-such as meaning and purpose, interconnectedness, and transcendence-which go beyond any specific religion. This guide was crafted to improve the spiritual well-being of adult patients aged 19 and older, as well as their families, who are receiving end-of-life care. The provision of spiritual care in hospice and palliative settings aims to assist patients and their families in finding life's meaning and purpose, restoring love and relationships, and helping them come to terms with death while maintaining hope. It is recommended that spiritual needs and the interventions provided are periodically reassessed and evaluated, with the findings recorded. Additionally, hospice and palliative care teams are encouraged to pursue ongoing education and training in spiritual care. Although challenges exist in universally applying this guide across all hospice and palliative care organizations in Korea-due to varying resources and the specific environments of medical institutions-it is significant that the Korean Society for Hospice and Palliative Care has introduced a spiritual care guide poised to enhance the spiritual well-being and quality of care for hospice and palliative care patients.

무지 외반증의 수술비 및 보험 (Operation Fee and Insurance Charge of Hallux Valgus Surgery)

  • 송하헌;심대무;김동철;권석현;김종윤
    • 대한족부족관절학회지
    • /
    • 제10권2호
    • /
    • pp.238-241
    • /
    • 2006
  • Purpose: The purpose of this study was to figure out the appropriate and systemic insurance charge for the hallux valgus operations. Materials and Methods: 5 Hospitals for hallux valgus operations were analyzed how they have been charging the national health insurance corporation for their operation fees and how to use the estimated guide and authoritive interpretation through the guide book of health insurance medical treatment grant expense and the guide book of Health insurance medical treatment. Results: There are nothing for guiding principle of hallux valgus operations in both books but a guide of Mcbride operation which is approved 'JA-93-KA and JA-31' for operation fee. So majority of hospitals have charged operation fee depending on their own interpretations they like. According to the guide books, there was a authoritive interpretation that simultaneous operation of osteotomy and tendon transfer for cerebral palsy and flat foot can be eatimated as 'osteotomy+JA-93-NA'. Conclusion: Distal soft tissue procedure should be approved as 'JA-93-NAx100%+JA-31x50%' according to the the estimated guide and authoritive interpretation if transected adductor hllucis is transfered to first metatarsal head. So distal chevron osteotomy could be 'JA-30-1-RAx100%+JA-31x50%', proximal metatarsal osteotomy could be 'JA- 93-NAx100%+JA-31-50%+JA-30-1-RAx50%', first metatarsocuneiform joint arthrodesis could be 'JA-93-NAx100%+ JA-31x50%+JA-73-RAx50%'.

  • PDF

Reliability of a chairside CAD-CAM surgical guide for dental implant surgery on the anterior maxilla: An in vitro study

  • Phyo Ei Ei Htay;Richard Leesungbok;Suk Won Lee;Yu-Jin Jee;Kyung Lhi Kang;Sung Ok Hong
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권5호
    • /
    • pp.259-270
    • /
    • 2023
  • PURPOSE. This study evaluated the reliability of the chair-side CAD-CAM surgical guide (CSG) in the anterior maxilla by comparing its accuracy with the laboratory 3D-printed surgical guide (3DSG) and manual surgical guide (MSG) concerning different levels of dentists' surgical experience. MATERIALS AND METHODS. Ten surgical guides of each type (MSG, 3DSG, and CSG) were fabricated on a control study model with missing right and left central incisors. Sixty implants were placed in 30 study models by two dentists (one inexperienced and one experienced) using three different types of surgical guides. Horizontal deviations at shoulder and at apex, vertical, and angular deviations were measured after superimposing the planned and placed implant positions in the software. Kruskal-Wallis and Mann-Whitney U tests were used to compare the accuracy of three types of surgical guides in each dentist group and the accuracy of each surgical guide between two dentists (α = .05). RESULTS. There were no significant differences in any deviations between CSG and 3DSG, apart from angular deviation, for both dentists' groups. Moreover, both CSG and 3DSG showed no significant differences in accuracy between the two dentists (P > .05). In contrast, MSG demonstrated significant differences from CSG and 3DSG and a significant difference in accuracy between the two dentists (P < .05). CONCLUSION. CSG provides superior accuracy to MSG in implant placement in the maxillary anterior region and is comparable to 3DSG at different levels of surgical experience, while offering the benefits of shorter manufacturing time and reduced patient visits.

진료실 CAD-CAM에 의한 컴퓨터 가이드 임플란트 수술과 즉시 임시보철치료: 증례보고 (Computer-guided implant surgery and immediate provisionalization by chair-side CAD-CAM: A case report)

  • 현상우;이성복;이석원;조영은
    • 대한치과보철학회지
    • /
    • 제59권4호
    • /
    • pp.478-486
    • /
    • 2021
  • 치과와 기공실을 오가며 복잡하게 진행되는 기존 CAD-CAM 컴퓨터 가이드 제작 방식을 단 순화하기 위하여, 진료실에 설치한 바로가이드 시스템(VARO Guide, CAD, Pre-Guide, VARO-mill, NeoBiotech, Seoul, South Korea)을 통하여 Top-Down 개념과 수복 주도개념을 적용하여 1-day 수술과 임시보철을 완료하는 증례를 보고하고자 한다. Pre-Guide를 통해 환자의 중심위에서 교합을 채득하고 CT를 촬영하며, 진료실 내 컴퓨터에서 CAD를 통해 바로가이드를 1시간 내에 제작하였다. 미리 제작된 광중합 레진이 담긴 Pre-Guide 트레이를 술부에 위치시킨 후 중심위에서 CT를 촬영하였다. CT 데이터가 진료실 내 컴퓨터로 전송되면 수복 위치를 정한 후 이어서 3차원적으로 턱뼈에서 임플란트를 식립할 위치를 디자인하여 STL 파일로 추출하였다. 그리고 진료실에 설비된 밀링 기계(VARO-mill)에 Pre-Guide를 고정하여 수술용 가이드를 15분 내에 제작한다. 이 가이드로 환자는 한번 내원하여 임플란트를 계획한 위치에 안전하고 정확하게 수술해 줌과 더불어, 초기고정력이 양호한 임플란트에 대해서는 즉시임시치아까지 장착해 주어 환자에게 즉시 기능이 가능하도록 할 수 있었다.

Invention of the Guide Catheter Irrigation Monitoring Device for Neuroendovascular Therapy

  • Ozkul, Ayca;Park, Jong-Hyun;Shin, Dong-Seung;Yilmaz, Ali;Kim, Bum-Tae
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권4호
    • /
    • pp.471-474
    • /
    • 2017
  • Objective : The thromboembolic events during neuroendovascular therapy (NET) are the major complications of concern that can be occasionally fatal. The thrombotic occlusion of the guide catheter for NET is thought to be the risk of the thromboembolic events. We have developed an idea for inventing the monitoring system of the continuous irrigation through the guide catheter. We herein present a unique invention of the guide catheter irrigation monitoring device. Methods : We have developed ideas for preventing the thrombotic occlusion of the guide catheter. In order to design a convenient device working in the practical use, we have consulted and shared the ideas with the electrical engineers about putting the invention. Results : The guide catheter irrigation monitoring device (GCIMD) consisted of three parts of optical sensor, main body and electric adapter. In brief, the basic principles of working of the GCIMD are as follows. The optical sensor is attached to the dripping chamber of the line to irrigation solution. The main body had the small light and speaker to make an alarm sounds. The sensor monitors the dripping of flush solution. If the dripping stops more than three seconds, a warning alarm has been activated. So, the operating physicians can concentrate and check the guide catheter irrigation. After the use of the GCIMD, there was no major thromboembolic complication in conjunction with the thrombotic occlusion of the guide catheter in our institute. Conclusion : We have developed a brilliant invention of the GCIMD for NET.