• Title/Summary/Keyword: Horizontal concentration

Search Result 325, Processing Time 0.028 seconds

An Effect of Heat Input on Thermal Storage for Horizontal Thermal Storage Tank with Heat pipe (열 파이프용 수평 축열조에서의 열 입력이 축열에 미치는 영향)

  • 최우석;박이동;김철주;황영규
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.69-76
    • /
    • 1995
  • The horizontal thermal storage tank with heat pipe which is suitable for the sensible heat storage system is able to store a hot water from the heat source such as heating pad efficiently and to supply a hot water to load rapidly. Therefore Arrangement of heating pad affects thermal flow and thermal storage efficiency. So, if effective arrangement is decided for condition of constant number of heating pad, the more rapid thermal flow effect and higher thermal storage efficiency is obtainable by active heat transfer. In this experiments, number of heating pad is ranged from three, five and nine, and when number of heating pad is constant, arrangement are two types of concentration-type and dispersion-type. As a result, for the case of concentration-type of heating pad, strong entrainment take place in horizontal thermal storage tank with heat pipe by active heat transfer and in the constant number of heating pad, the concentration-type has the higher efficiency with about 5∼6% than the dispersion-type. Therefore, when heating pad is equipted to horizontal thermal storage tank with heat pipe, concentration-type of heating pad is an efficient design in constant number. of heating pad.

  • PDF

Evaluation of the disinfectant concentration used on livestock facilities in Korea during dual outbreak of foot and mouth disease and high pathogenic avian influenza

  • Kim, Seongjoon;Chung, Hansung;Lee, Hyesook;Myung, Donghoon;Choi, Kwanghoon;Kim, Sukwon;Htet, Swe Lynn;Jeong, Wooseog;Choe, Nonghoon
    • Journal of Veterinary Science
    • /
    • v.21 no.3
    • /
    • pp.34.1-34.10
    • /
    • 2020
  • Background: A nationwide outbreak of foot-and-mouth disease (FMD) in South Korea caused massive economic losses in 2010. Since then, the Animal and Plant Quarantine Agency (QIA) has enhanced disinfection systems regarding livestock to prevent horizontal transmission of FMD and Avian influenza (AI). Although the amount of disinfectant used continues to increase, cases of FMD and AI have been occurring annually in Korea, except 2012 and 2013. Objectives: This study measured the concentration of the disinfectant to determine why it failed to remove the horizontal transmission despite increased disinfectant use. Methods: Surveys were conducted from February to May 2017, collecting 348 samples from disinfection systems. The samples were analyzed using the Standards of Animal Health Products analysis methods from QIA. Results: Twenty-three facilities used inappropriate or non-approved disinfectants. Nearly all sampled livestock farms and facilities-93.9%-did not properly adjust the disinfectant concentration. The percentage using low concentrations, or where no effective substance was detected, was 46.9%. Furthermore, 13 samples from the official disinfection station did not use effective disinfectant, and-among 72 samples from the disinfection station-88.89% were considered inappropriate concentration, according to the foot-and-mouth disease virus guidelines; considering the AIV guideline, 73.61% were inappropriate concentrations. Inappropriate concentration samples on automatic (90.00%) and semi-automatic (90.90%) disinfection systems showed no significant difference from manual methods (88.24%). Despite this study being conducted during the crisis level, most disinfectants were used inappropriately. Conclusions: This may partially explain why horizontal transmission of FMD and AI cannot be effectively prevented despite extensive disinfectant use.

A Study on the Diffusion of Atmospheric Pollutants over Taegu (대구상공에서의 대기 오염 물질 확산에 관한 연구)

  • Yun, Il-Hui;Min, Gyeong-Deok;Park, Dong-Jae
    • Journal of Environmental Science International
    • /
    • v.3 no.3
    • /
    • pp.241-252
    • /
    • 1994
  • Meteorological parameters In the atmospheric boundary layer and the vertical and horizontal dispersion parameters were determined by analyzing the data obtained by the special upper-air observations of one clear day for each season from October 1991 to August 1992. The concentration of the aklospheric pollutants over Taegu was analyzed by using the application of the Gaussian diffusion model. In the diurnal variation of diffusion of atmospheric pollutants, vertical diffusion due to turbulence is active in daytime while horizontal diffusion due to wind is active in nighttime. The mean concentration of pollutants in the side of downwind is higher during the daytime than the nighttime. Thus, the height of the mixed-layer at the nighttime considered as the most important parameter of the mean concentration of pollutants. In the seasonal variation of diffusion of atmospheric pollutants, vertical diffusion due to strong solar radiation is active in summer case day, and horizontal diffusion due to strong wind is active in winter case day. In winter case day, the mean concentration of pollutants in the side of downwind is maximum in the daytime. However, in summer case day, that is maximum in the nighttime.

  • PDF

Filmwise Condensation of Freon Vapor Including Air on a Horizontal Tube (공기를 함유한 프레온 증기의 수평관 외부에서의 막응축)

  • Kim, K.H.;Ko, H.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.1
    • /
    • pp.20-29
    • /
    • 1995
  • A theoretical model for film condensation of a vapor including a relatively lighter noncondensable gas on a horizontal tube has been formulated on the basis of the conservation laws and other fundamental physical principles. The model is applied to the prediction of the condensation heat transfer characteristics for the Freon vapor in the presence of air on a horizontal tube. Calculated results for the mean heat transfer coefficient, which is shown to depend strongly on the bulk concentration of air, are in good agreement with the available experimental results for a range of operating conditions. The distributions of physical quantities along the surface of tube are also calculated, such as the boundary layer thickness and local heat transfer coefficient. The present model is readily reduced to the Nusselt model as the bulk concentration of air decreases to zero. Therefore, the transition from the condensation of pure vapor to that of vapor-air mixture occurs continuously not abruptly.

  • PDF

An Effect of Heat Input on Thermal Storage for Horizontal Thermal Storage Tank with Heat pipe (열 파이프용 수평 축열조에서의 열 입력이 축열에 미치는 영향)

  • Pak, Ee-Tong;Jeong, Un-Chul
    • Solar Energy
    • /
    • v.16 no.2
    • /
    • pp.39-47
    • /
    • 1996
  • The horizontal thermal storage tank with heat pipe which is suitable for the sensible heat storage system is able to store a hot water from the heat source such as heating pad efficiently and to supply a hot water to load rapidly. And arrangement of heating pad play an important role in thermal flow and thermal storage efficiency. In this experiments, number of heating pad is ranged from three, five and nine, and when there is no change on number of heating pad, arrangements are two types of concentration-type and dispersion-type. Strong entrainment take place in the case of concentration-type of heating pad, and rapid temperature rise(${\Delta}{\doteqdot}1.6{\sim}3.2^{\circ}C$) in the tank is obtainable on the concentration-type than dispersion-type. In the constant number of heating pad, the concentration-type has the higher efficiency with about $5{\sim}6%$ than the dispersion-type Therefore, concentration-type of heating pad is an efficient design in constant number of heating pad.

  • PDF

Influence of Refrigeration Oil on Evaporation Heat Transfer of R-134a in a Horizontal Micro-Fin Tube (냉동유가 수평 마이크로 핀관내 R-134a의 증발열전달에 미치는 영향)

  • 배상철;강태욱;김정훈;정찬영;김종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.1
    • /
    • pp.140-150
    • /
    • 1996
  • CFC-12, which has been used most widely in automobile air conditioners and household refrigerators is scheduled to be phased out soon because of its high ozone depletion potential. Now HFC-134a is suggested as an alternative refrigerant for CFC-12. In this Study, we intended to investigate how PAG oil influence evaporation heat transfer and flow pattern, using R-134a and PAG oil influences evaporation heat transfer and flow pattern, using R-134a and PAG oil in the horizontal miro-fin evaporation tube. Experiments were conducted under the flowing est conditions : mass velocity 86-250kg/$m^2$s, heat flux 5-30 ㎾/$m^2$, oil concentration 0-21 wt.% and saturation temperature 5$^{\circ}C$. Local evaporation heat transfer coefficients were found to be higher at the top, side and bottom of the tube in this order. Average heat transfer coefficients turned out to increase with oil concentration increment up to 3 wt.% oil concentration, whereas heat transfer coefficients gradually decreased over 3 wt.% oil concentration, because of oil-rich liquid film was formed on the heat transfer surface. Flow patterns were rapidly transitioned to annular regimes up to 3 wt.% oil concentration. In case of pure refrigerant, measured heat transfer coefficients in the experiments were similar to those of Kandlikar's correlation.

  • PDF

Dynamic Analysis of Precast Concrete Large Panel Structures with Horizontal Joints (수평 접합부를 고려한 프리캐스트 대형판 구조물의 동적 해석에 관한 연구)

  • 정일영;송진규;강해관
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1996.10a
    • /
    • pp.249-257
    • /
    • 1996
  • Dynamic Analysis of Precast Concrete Large Panel Structures with Horizontal Joints The damage in precast large panel structures subjected to destructive earthquakes is generally localized in the joints. Particularly, the horizontal joints influence on the stability and integrity of the overall structure. In this research a dynamic analysis was carried out by the macro model that idealized the horizontal joints as inelastic-nonlinear spring systems. It is capable of simulating the behavior of precast concrete structures using the mathematical model. As a result of the dynamic parametric study for the case of 0.12g peak base accelerations, it is found that all joints behave elastically for sliding and opening and that all forces are well distributed without excessive local concentration on my horizontal joints.

  • PDF

Temporal and Spatial Distributions of PM10, NOx and O3 around the Road (도로 주변의 PM10, NOx 및 O3의 시공간적 농도 분포 연구)

  • Kwon O-Yul;An Young-Sang
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.4
    • /
    • pp.440-450
    • /
    • 2006
  • PM10, NOx, and $O_3$ were measured at six locations, of which each three is horizontally and vertically distributed respectively, in an apartment complex around the heavily traffic road. Those were measured seven times a day with two hours interval starting from 8 o'clock in the morning for 15 days during May 2005 $\sim$ September 2005. PM10 and NOx showed high concentrations in rush hours while low concentrations in midday due to the direct emissions from automobiles in operation. Temporal variations of 01 showed very much similar trend appeared in normal urban atmospheres. The spatial distributions of PM10, NOx and $O_3$ showed that almost all of concentrations were higher in a row of Roadside > Surface at 130 m apart from the road > Surface at 230 m apart from the road > 3rd floor of apartment building > 15th floor of apartment building > 27th floor of apartment building. Model equations, which can project spatial concentration distributions, were constructed by combining the horizontal and the vertical linear regression equations derived from six mean values corresponding to six measuring locations. According to inter-comparison of PM10, NOx, and $O_3$ with the constructed model equations, concentration gradients were higher in a row of Vertical direction of NOx > Vertical direction of PM10 > Horizontal direction of NOx > Horizontal direction of PMIO > Vertical direction of $O_3$ > Horizontal direction of $O_3$. Why concentration gradient of particulate PM10 is lower than that of gaseous NOx is in question, and should be studied.

A Study on the Effect of Particulate Matter Concentration on the Reliability of Decomposition Model (미세먼지 농도가 직산분리 모델의 신뢰성에 미치는 영향에 관한 연구)

  • Lee, Sang-Hyuk;Lee, Kyung-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.4
    • /
    • pp.55-67
    • /
    • 2019
  • Recently, as the amount of particulate matter blowing from China increases, the domestic air environment is rapidly deteriorating. This pollution of the atmosphere greatly affects the light energy reaching the ground. Particularly, since the light enters the solar cell module in various forms, the amount of input energy of the solar power generation system may be changed depending on the ratio of direct beam irradiation and diffused horizontal irradiation. In this paper, we analyze how the ratio of direct beam component and diffused component on global horizontal irradiation varies with the atmospheric conditions. In addition, the reliability of the regression equation, designed to decompose the global horizontal irradiation into horizontal direct beam irradiation and diffused horizontal irradiation, was verified according to the level of air pollution. So, we derive the most suitable decomposition model for use in domestic climatic conditions in Korea by comparing the ratio of direct and diffuse component on the horizontal which is calculated with Perez model and Watanabe model using the meteorological weather data observed for 14 months. Finally, to reduce the error of the transposition result, we verified the reliability of the decomposition which depends on the atmospheric environment.

Composition of Fine Mesh Model for Explication of Mesoscale Wind Field (중규모 바람장 해석을 위한 Fine Mesh Model의 구성)

  • 이화운;김유근
    • Journal of Environmental Science International
    • /
    • v.4 no.2
    • /
    • pp.159-168
    • /
    • 1995
  • To predict reasonably the movement and the concentration of the pollutants in the coastal area. A simulation model should be prepared considering detail topography with land-sea and the urban effects, and the resolution near the source. The explicit method can not be applied due to the instability of the numerical calculation in high horizontal-grid resolution, while the ADI scheme satisfied with the high horizontal grid resolution and can be used in the fine mesh system which shows the detail topography, atmospheric flow The ADI method which studied the high horizontal grid resolution was excellent. The two dimensional model used in the study using ADI method is proved as a reasonable model to predict the wind field in any small scale area including mountainous coastal urban area.

  • PDF