• 제목/요약/키워드: Horizontal channel

검색결과 265건 처리시간 0.022초

수중음향 수평 배열 플랫폼의 거동 해석과 시험 (Analysis and Tests of the Behavior of an Underwater Acoustic Horizontal Array Platform)

  • 이종무;김기훈;변성훈
    • 한국해양공학회지
    • /
    • 제32권4호
    • /
    • pp.222-227
    • /
    • 2018
  • Most underwater acoustic arrays for low frequency operation are deployed vertically, but a mid-range frequency horizontal array system is being developed by the Korea Research Institute of Ships and Ocean Engineering (KRISO). The horizontal array platform is deployed underwater and kept in place by weather vaning mooring. This is essential because it is nearly impossible to keep a submerged body at a given position in the water without any external force. Hence, the horizontal array platform can maintain the desired position in the presence of a weak tidal current. The objective of this study is to design an underwater platform that can maintain its horizontal position in a weak current. First, the authors investigated various virtual models, selected one of the models, and performed a small model test of the selected model at a basin. We calculated the external forces associated with the 2D motion, and then we conducted a large basin test followed by a circulation water channel test for the manufactured array platform. The results of the simplified 2D motion calculation essentially matched the results of the underwater test.

PDP에서 가중치 오차확산 보정 (Weighted error diffusion in PDP)

  • 정한영;이동호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.179-181
    • /
    • 2005
  • There is asymmetric in horizontal and vertical side of PDP cell. Every vertical line has BM(Black Mask) to improve luminance contrast. When error diffusion is processed in PDP system, these problems make an error bigger. In 4 inch PDP system, every red, green, blue color of test pattern is presented and each luminance is measured. That is called horizontal(H), diagonal right(R), diagonal left(L) and vertical(V). In red channel, high luminance descending order is V-H-R-L. In green channel, V-H-L-R. In blue channel, V-M-R=L. After average luminance of each direction is calculated. new weighted error diffusion(Weighted ED) is proposed. In digital image signal processing, the error in weighted ED is differ from ED's. The image of weighted ED is more less error compare to conventional ED and close to original image. As the gray level linearity and big size panel is adopted, weighted ED could produce good image.

  • PDF

개방된 캐비티를 가진 채널 내에서의 혼합대류 유동과 열전달 특성 (Characteristics of the Mixed Convection Flow and Heat Transfer in a Channel with Open Cavity)

  • 고영창;배대석;김남식
    • 동력기계공학회지
    • /
    • 제11권4호
    • /
    • pp.56-64
    • /
    • 2007
  • A numerical simulation is carried out mixed convection in horizontal channel with a heat source from below of rectangular cavity. Finite volume method was employed for the discretization and PISO algorithm was used for calculating pressure term. The parameters governing the problem are the Reynolds number ($10^{-2}{\leq}Re{\leq}50$), the Rayleigh number ($10^3{\leq}Ra{\leq}2.06{\times}10^5$), the Prandtl number ($0.72{\leq}Pr{\leq}909$), the aspect ratio ($0.5{\leq}AR=W/H{\leq}2$) and the angle of inclination ($0^{\circ}{\theta}60^{\circ}$). Mean Nusselt number distributions were obtained and effect of Reynolds number, Rayleigh number and Prandtl number on mixed convection in the horizontal channel with rectangular cavity were investigated.

  • PDF

Quantitative observation of co-current stratified two-phase flow in a horizontal rectangular channel

  • Lee, Seungtae;Euh, Dong-Jin;Kim, Seok;Song, Chul-Hwa
    • Nuclear Engineering and Technology
    • /
    • 제47권3호
    • /
    • pp.267-283
    • /
    • 2015
  • The main objective of this study is to investigate experimentally the two-phase flow characteristics in terms of the direct contact condensation of a steam-water stratified flow in a horizontal rectangular channel. Experiments were performed for both air-water and steam-water flows with a cocurrent flow configuration. This work presents the local temperature and velocity distributions in a water layer as well as the interfacial characteristics of both condensing and noncondensing fluid flows. The gas superficial velocity varied from 1.2 m/s to 2.0 m/s for air and from 1.2 m/s to 2.8 m/s for steam under a fixed inlet water superficial velocity of 0.025 m/s. Some advanced measurement methods have been applied to measure the local characteristics of the water layer thickness, temperature, and velocity fields in a horizontal stratified flow. The instantaneous velocity and temperature fields inside the water layer were measured using laser-induced fluorescence and particle image velocimetry, respectively. In addition, the water layer thickness was measured through an ultrasonic method.

한 개의 등온사각빔이 부착된 채널에서의 대류열전달 (Convective Heat Transfer in a Channel with an Isothermal Rectangular Beam)

  • 권순석;이재신
    • 태양에너지
    • /
    • 제14권2호
    • /
    • pp.75-90
    • /
    • 1994
  • 본 연구에서는 한 단역벽에 한개의 등온사각빔이 부착된 2차원 수평과 수직단열채널에서의 열 에너지 이송에 대하여 수치해석적으로 연구하였다. 빔의 형상비는 H/B=$0.25{sim}4$, Reynolds수는 Re=$50{\sim}500$ 그리고 Grashof수는 Gr=$0{\sim}5{\times}10^4$범위에서 해를 구하였다. Re=100인 경우 수평과 수직채널에서 빔의 평균 Nusselt수는 Gr=0에서는 같은 값을 나타내며, Grashof수가 증가할수록 증가하였으며, 형상비가 증가할수록 감소하였다. Gr=$10^4$, Re=100인 경우 수평과 수직채널에서 빔의 평균 Nusselt수는 수직채널이 수평채널에 비하여 $0.25{\leq}H/B<1.1$에서는 높게, $1.1{\leq}H/B{\leq}4.0$에서는 낮게 나타났다. Re=100, $0<Gr{\leq}5{\times}10^4$인 경우 수평과 수직채널에서 빔의 평균 Nusselt수 분포는 수직채널이 수평채널에 비하여 H/B=0.25에서는 높고 H/B=4.0에서는 낮으며 H/B=1.0에서는 다소 높게 나타났다. 실험으로 얻은 간섭사진의 등온선과 수치계산으로 구한 등온선이 비교적 잘 일치하여 수치해석의 타당성을 입증하였다.

  • PDF

Effects of Channel Structure on the Quality Competition of Exclusively Distributed Products

  • Kang, Yeong Seon
    • Asia Marketing Journal
    • /
    • 제19권4호
    • /
    • pp.37-59
    • /
    • 2018
  • This study investigates the effects of the distribution channel structure on quality decisions under duopoly competition. I considers a set-up in which two retailers compete on product quality and retail price. In the set-up, the integrated retailer has the power to determine the quality of its exclusive product, while the decentralized retailer does not. For the decentralized retailer, the supplier determines product quality. I find that asymmetric pairs of a decentralized channel by one retailer and an integrated channel by the other retailer can be a Nash equilibrium in a simultaneous-channel-choice model. The two retailers select different levels of quality, and this quality competition benefits retailers by softening price competition. In a sequential-channel-choice model, I find that the leader can obtain a first-mover advantage. From the perspective of the supplier, which can decide the distribution channel structure and level of quality, both suppliers choose the decentralized channel in equilibrium.

The Effect of Technology Spillover on Business Efficiency: A Case Study in Vietnam

  • PHUNG, Mai Lan;HOANG, Vu Hiep;NGUYEN, Thi Thanh Huyen;PHAM, Thi Thanh Van;TRAN, Viet Tien;HOANG, Van Hoa
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제8권5호
    • /
    • pp.355-364
    • /
    • 2021
  • The main objective of this study is to examine the interactive effect of technology spillover channels on business efficiency within the case study of manufacturing industry of Vietnam during the period from 2012 to 2018. The research model was developed with business efficiency as dependent variable and the relevant factors affecting the technology spillover capacity as independent variables. With a sample of 2,776 cross-sectional enterprises, panel data analysis approach was adopted to estimate the impact of technology spillover issue. Different spillover channels were also included in the analysis to enhance the empirical result. The study reveals that technology spillovers positively influence manufacturing business efficiency, in which horizontal spillover channel produces negative impact and vertical spillover channel, creates positive impact. Several factors that negatively affect the technology spillover capacity of businesses could be mentioned such as limited skills and experiences of workers, methods of implementing R&D, and the existence of FDI enterprises. Meanwhile, the rise of other factors related to joint-venture activities can help to increase the technology spillover capacity of businesses. In addition, skill and experience transfer makes a partial impact since this variable only positively affect the vertical spillover channel and provide no evidence of impact regarding horizontal spillover channel model.

미세 수평 사각 유로에서의 비등 열전달에 대한 실험적 연구 (An Experimental Study on Flow Boiling Heat Transfer within Horizontal Rectangular Channels with Small Heights)

  • 이상용;이한주
    • 대한기계학회논문집B
    • /
    • 제25권9호
    • /
    • pp.1209-1218
    • /
    • 2001
  • The present paper proposes a new correlation for the flow boiling heat transfer coefficients in the low flow rate condition (Re(sub)LF$\leq$200) within horizontal rectangular channels with small gaps (heights). The gap between the upper and the lower plates of each channel ranges from 0.4 to 2mm while the channel width being fixed to 20mm. Refrigerant 113 was used as the test fluid. The mass flux ranges from 50 to 200kg/㎡s and the channel walls were uniformly heated with the heat flux range of 3-15kW/㎡. The quality range covers from 0.19 to 0.76 and the flow pattern is considered to be annular. The measured heat transfer coefficients increase with the mass flux and the local quality; however the effect of the heat flux appears to be minor. At the low mass flux condition, which is more likely with the smaller gap size, the heat transfer is primarily controlled by the liquid film thickness. The proposed F factor for the heat transfer coefficient in the range of Re(sub)LF$\leq$200 well represents the experimental data within the deviation of $\pm$20%. The Kandlikars flow boiling correlation covers the higher flow-rate range(Re(sub)LF>200) within the deviation of $\pm$20%.

간접냉각방식을 이용한 열원이 부착된 채널내의 열전달 촉진에 관한 연구 (The study on heat transfer enhancement using indirect cooling system in the channel with heat source)

  • 김광추;박만흥;윤준규
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.321-331
    • /
    • 1999
  • A numerical study is carried out for increasing heat removal using indirect cooling system. Computation is performed for nine cases as variation of flow condition in the lower channel. As the result of this study, water is more effective than air at the same pressure loss in spite of the lower inlet velocity. In channel configuration, the vertical channel is more effective than horizontal channel because of the buoyancy effect. Under the condition that heat generation is the same, counter flow effectively decreases the temperature difference among blocks. Parallel flow is more effective than counter flow when average temperature of all blocks is considered. In the case of installing obstacles in the lower channel, it is desirable to install obstacles in the bottom of lower channel. Heat transfer rate increases as the height of obstacles increases.

  • PDF