• Title/Summary/Keyword: Horizontal cell

Search Result 229, Processing Time 0.024 seconds

NUMERICAL SOLUTIONS OF AN UNSTEADY 2-D INCOMPRESSIBLE FLOW WITH HEAT AND MASS TRANSFER AT LOW, MODERATE, AND HIGH REYNOLDS NUMBERS

  • AMBETHKAR, V.;KUSHAWAHA, D.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.21 no.2
    • /
    • pp.89-107
    • /
    • 2017
  • In this paper, we have proposed a modified Marker-And-Cell (MAC) method to investigate the problem of an unsteady 2-D incompressible flow with heat and mass transfer at low, moderate, and high Reynolds numbers with no-slip and slip boundary conditions. We have used this method to solve the governing equations along with the boundary conditions and thereby to compute the flow variables, viz. u-velocity, v-velocity, P, T, and C. We have used the staggered grid approach of this method to discretize the governing equations of the problem. A modified MAC algorithm was proposed and used to compute the numerical solutions of the flow variables for Reynolds numbers Re = 10, 500, and 50000 in consonance with low, moderate, and high Reynolds numbers. We have also used appropriate Prandtl (Pr) and Schmidt (Sc) numbers in consistence with relevancy of the physical problem considered. We have executed this modified MAC algorithm with the aid of a computer program developed and run in C compiler. We have also computed numerical solutions of local Nusselt (Nu) and Sherwood (Sh) numbers along the horizontal line through the geometric center at low, moderate, and high Reynolds numbers for fixed Pr = 6.62 and Sc = 340 for two grid systems at time t = 0.0001s. Our numerical solutions for u and v velocities along the vertical and horizontal line through the geometric center of the square cavity for Re = 100 has been compared with benchmark solutions available in the literature and it has been found that they are in good agreement. The present numerical results indicate that, as we move along the horizontal line through the geometric center of the domain, we observed that, the heat and mass transfer decreases up to the geometric center. It, then, increases symmetrically.

Analysis of Lateral Inhibitive-Function and Verification of Local Light Adaptive-Mechanism in a CMOS Vision Chip for Edge Detection (윤곽검출용 CMOS 시각칩의 수평억제 기능 해석 및 국소 광적응 메커니즘에 대한 검증)

  • Kim, Jung-Hwan;Park, Dae-Sik;Park, Jong-Ho;Kim, Kyoung-Moon;Kong, Jae-Sung;Shin, Jang-Kyoo;Lee, Min-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.57-65
    • /
    • 2003
  • When a vision chip for edge detection using CMOS process is designed, there is a necessity to implement local light adaptive-function for detecting distinctive features of an image at a wide range of light intensities. Local light adaptation is to achive the almost same output level by changing the size of receptive-fields of the local horizontal cell layers according to input light intensities, based on the lateral inhibitive-function of the horizontal cell. Thus, the almost same output level can be obtained whether input light intensities are much or less larger than background. In this paper, the horizontal cells using a resistive network which consists of p-MOSFETs were modeled and analyzed, and the local light adaptive-mechanism of the designed vision chip using the resistive network was verified.

Development of a Real-Time Measurement System for Horizontal Soil Strength

  • Cho, Yongjin;Lee, Dong Hoon;Park, Wonyeop;Lee, Kyou Seung
    • Journal of Biosystems Engineering
    • /
    • v.40 no.3
    • /
    • pp.165-177
    • /
    • 2015
  • Purpose: Accurate monitoring of soil strength is a key technology applicable to various precision agricultural practices. Soil strength has been traditionally measured using a cone penetrometer, which is time-consuming and expensive, making it difficult to obtain the spatial data required for precision agriculture. To improve the current, inefficient method of measuring soil strength, our objective was to develop and evaluate an in-situ system that could measure horizontal soil strength in real-time, while moving across a soil bin. Methods: Multiple cone-shape penetrometers were horizontally assembled at the front of a vertical plow blade at intervals of 5 cm. Each penetrometer was directly connected to a load cell, which measured loads of 0-2.54 kN. In order to process the digital signals from every individual transducer concurrently, a microcontroller was embedded into the measurement system. Wireless data communication was used between a data storage device and this real-time horizontal soil strength (RHSS) measurement system travelling at 0.5 m/s through an indoor experimental soil bin. The horizontal soil strength index (HSSI) measured by the developed system was compared with the cone index (CI) measured by a traditional cone penetrometer. Results: The coefficient of determination between the CI and the HSSI at depths of 5 cm and 10 cm ($r^2=0.67$ and 0.88, respectively) were relatively less than those measured below 20 cm ($r^2{\geq}0.93$). Additionally, the measured HSSIs were typically greater than the CIs for a given numbers of compactor operations. For an all-depth regression, the coefficient of determination was 0.94, with a RMSE of 0.23. Conclusions: A HSSI measurement system was evaluated in comparison with the conventional soil strength measurement system, CI. Further study is needed, in the form of field tests, on this real-time measurement and control system, which would be applied to precision agriculture.

Optimum Structural Design of a Triaxial Load Cell for Wind Tunnel Test (풍동용 3 축 로드셀의 구조최적설계)

  • Lee, Jae-Hoon;Song, Chang-Kon;Park, Seong-Hun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.2
    • /
    • pp.226-232
    • /
    • 2011
  • In this study, an optimized design of a triaxial load cell has been developed by the use of finite element analysis, design of experiment and response surface method. The developed optimal design was further validated by both stress-strain analysis and natural vibration analysis under an applied load of 30 kgf. When vertical, horizontal, and axial loads of 30 kgf were applied to the load cell with the optimal design, the calculated strains were satisfied with the required strain range of $500{\times}10^{-6}{\pm}10%$. The natural vibration analysis exhibited that the fundamental natural frequency of the optimally designed load cell was 5.56 kHz and higher enough than a maximum frequency of 0.17 kHz which can be applied to the load cell for wind-tunnel tests. The satisfactory sensitivity in all triaxial directions also suggests that the currently proposed design of the triaxial load cell enables accurate measurements of the multi-axial forces in wind-tunnel tests.

Comparison of Cell and Nuclear Size Difference between Diploid and Induced Triploid in Marine Medaka, Oryzias dancena

  • Goo, In Bon;Im, Jae Hyun;Gil, Hyun Woo;Lim, Sang Gu;Park, In-Seok
    • Development and Reproduction
    • /
    • v.19 no.3
    • /
    • pp.127-134
    • /
    • 2015
  • The influence of triploidization on cell and nucleus size characteristics of the same tissues of erythrocyte, retina, kidney, hepatocyte and midgut epithelium in marine medaka, Oryzias dancena has been determined histologically. Induced triploid fish are produced by cold shock treatments. Likewise, the size of horizontal cell nucleus in inner nuclear layer of retina, ganglion cell nucleus in ganglion cell layer of retina, proximal tubule cell of kidney, hepatocytes and nuclear height of midgut epithelium all appear to be significantly larger than diploid (P<0.05). On the other hand, retina thickness is larger in diploid than induced triploid (P<0.05). Induced triploid shows low density of cell number. Results of this study suggest that same characteristics in the induced triploid exhibiting larger cells and nucleus sizes with fewer number of cells than the diploid can be useful criteria for the distinction between diploid and induced triploid, and also the ploidy level in marine medaka.

Numerical investigation on the bifurcation of natural convection in a horizontal concentric annulus (수평동심환상공간내 자연대류의 다중해에 관한 수치적 연구)

  • Jeong, Jae-Dong;Kim, Chan-Jung;Lee, Jun-Sik;Yu, Ho-Seon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.2
    • /
    • pp.252-263
    • /
    • 1997
  • Steady-state two-dimensional natural convective heat transfer in horizontal cylindrical annuli was studied by solving the governing equations based on the primitive variables. Emphasis was put on the occurrence of the multiple solutions at a given set of parameter values, and on the determination of the bifurcation points at which those multiple solutions begin to branch out. The multicellular flow pattern from the results of melting process in an isothermally heated horizontal cylinder for high Rayleigh numbers, was used as initial guesses for the field variables. This was succeeded in new bifurcation point to tetracellular solutions for an identical set of parameter variables of previous works. The close examination of flow pattern transition around bifurcation point was also conducted. It was found that the mechanisms of flow transition are different depending on the critical Rayleigh number of bifurcation point.

A Study on the Power Performance Measurement of Transparent Thin-film PV Windows of BIPV Depending on the Inclined Angle (건물일체형 투명 PV복층창의 설치조건에 따른 단위출력당 발전특성 분석연구)

  • An, Young-Sub;Song, Jong-Hwa;Kim, Seok-Ge;Lee, Sung-Jin;Yoon, Jong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.55-60
    • /
    • 2008
  • This study is on the analysis of power output of transparent thin-film PV windows which are integrated into the building envelope instead of traditional windows. 3 installation angles of vertical, horizontal and $30^{\circ}C$ inclination are investigated. To measure power output of PV windows, full scale mock-up house was designed and constructed. The power performance of PV window system was analyzed for horizontal angle, declination angle and vertical angle according to incline angle. Monitoring data are gathered from November 2006 to August 2007 and statistical analysis is performed to analysis a characteristics of power performance of transparent PV windows. Results show that annual power output of PV window with horizontal angle is 844.4kWh/kWp/year, declination angle 1,060kWh/kWp/year and vertical angle 431.6 kWh/kWp/year.

  • PDF

Effect of Mixed Jet with Primary Nozzle Area Ratio of Ejector on Oxygen Transfer Characteristics (산소 전달 특성에 미치는 이젝터 구동 노즐 면적비에 따른 혼합 분류의 영향)

  • Park, Sang Kyoo;Yang, Hei Cheon
    • Journal of ILASS-Korea
    • /
    • v.27 no.3
    • /
    • pp.126-133
    • /
    • 2022
  • The objective of this is to experimentally investigate the effect of mixed jet on the oxygen transfer characteristics with the primary nozzle area ratio of an annular nozzle ejector for the application of a microbial fuel cell. A direct visualization method with a high speed camera system was used to capture the horizontal mixed jet images, and a binarization technique was used to analyze the images. The clean water unsteady state technique was used for the oxygen transfer measurement. The air-water mixed jet discharging into a water tank behaved similar to a buoyancy or horizontal jet with the primary nozzle area ratio. It was found that an optimum primary nozzle area ratio was observed where the oxygen transfer performance reached its maximum value due to the decrease of air volume fraction and the increase of jet length and air bubble dispersion.

NUMERICAL SIMULATION OF NATURAL CONVECTION IN A CUBICAL-CAVITY BY UNSTRUCTURED CELL-CENTERED METHOD (비정렬 셀 중심 방법에 의한 3차원 캐비티내의 자연대류 현상에 관한 수치해석)

  • Myong H. K.;Kim J. E.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.61-66
    • /
    • 2005
  • Natural convection flows in a cubical, air-filled cavity that has one pair of opposing faces isothermal at different temperatures, Th and Tc, the remaining faces having a linear variation from Tc to Th are numerically simulated by a new solution code(PowerCFD) using unstructured cell-centered method. Solutions are obtained for configurations with a Rayleigh number as high as 105 and three inclination angles ${\theta}$ of the isothermal faces from horizontal: namely ${\theta}=0$, 45 and $90^{\circ}$. Interesting features are presented in detail and comparisons are made with benchmark solutions and experimental results found in the literature. It is found that the code is capable of producing accurately the nature of the laminar convection in a cubical, air-filled cavity with differentially heated walls.

  • PDF

Influence of Rubbing Direction on the Electro-Optic Characteristics of Fringe Field Driven Hybrid Aligned Nematic Liquid Crystal Cell (프린지 필드에 의해 구동되는 하이브리드형 네마틱 액정 셀에서 러빙방향에 따른 전기광학 특성)

  • 김완철;안명환;이승희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.1
    • /
    • pp.75-82
    • /
    • 2004
  • We have studied the influence of rubbing directions on electro-optic characteristics of the fringe field driven hybrid aligned nematic liquid crystal (LC) cell by computer simulation. When a LC with positive dielectric anisotropy is used, the results show that the driving voltage and transmittance decreases as the rubbing direction with respect to horizontal electric field direction increases. The reason for decrease in light transmission is the increase of tilt angle on the center of common electrode. In this paper, we have studied how the rubbing angle effects on the transmittance of the cell by investigating a distribution of electric field and LC director.