• Title/Summary/Keyword: Horizontal Fin

Search Result 85, Processing Time 0.022 seconds

An Experimental study on Heat Characteristics of Horizontal Tubes with Fin in Fluidized Bed Combustor (유동층 연소로 내에서 수평 휜 전열관의 열전달 특성에 관한 실험적 연구)

  • Kang, Hyung-Soo;Chung, Tae-Yong
    • Journal of the Korean Society of Combustion
    • /
    • v.1 no.1
    • /
    • pp.19-29
    • /
    • 1996
  • This study is to investigate the characteristics of heat transfer of a horizontal tube, with radial fins of various configuration, immersed in a high temperature fluidized bed. The experimental heat transfer variation is compared with that of a smooth tube. The finned tubes and smooth tube, with outside and inside diameter of 48.6mm and 30.6mm, are made of steel tubes. The depth of the fin is 5mm, the rake angles of fin are $25^{\circ},\;35^{\circ},\;45^{\circ}$ and the widthes of fin for each rake angle are 0mm, 1mm, 2mm and 3mm. A bed temperature is fixed at $880\;{\pm}\;10^{\circ}C$. A granular refractory(silica sand) is used as a bed material with mean particle diameters of 1.22mm and 1.54mm. The maximum heat transfer coefficient is achieved with the rake angle of $25^{\circ}$ and the width of 0mm for the mean particle size 1.22mm. The coefficient is 2.14 times larger than that for a smooth tube. The rake angle for the maximum heat transfer coefficient depends on the particle size of bed material. Also the transfer coefficient decreases as the width of fin increases.

  • PDF

Condensation heat transfer characteristics of R-22 and R-407C in micro-fin tubes (마이크로핀관에서의 냉매 R-22, R-407C의 응축전열특성에 관한 연구)

  • Roh, Geon-Sang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.1
    • /
    • pp.50-56
    • /
    • 2008
  • Experimental results for forced convection condensation of Refrigerant-22 and ternary Refrigerant-407C(HFC-32/125/134a 23/25/52 wt%) which is being considered as a substitute R-22 inside a horizontal micro-fin tube are presented. The test section was horizontal double-tube counterflow condenser with a length 4,000 mm micro-fin tube, having 8.53 mm ID, 0.2 mm fin height and 60 fins. The range of parameters of mass velocity were varied from 102.1 to 301.0 kg/(m2.s) and inlet quality 1.0. At the given experimental conditions. the average heat transfer coefficients for R-407C were lower than that for R-22 at a micro-fin tube. Over the mass velocity range tested. the PF(penalty factor) for R-22, R-407C were lower than the increasing ratio of heat transfer area by fins, and the EF(enhancement factor) for R-22, R-407C were higher than the increasing ratio of heat transfer area by fins.

An Investigation of Radiation Heat Transfer on The Horizontal Fin of An External Fuel Tank by Flame of a Flying Flare (날아가는 섬광탄이 연료탱크 수평핀에 미치는 복사열전달 연구)

  • Jung, Daehan;Kang, Chihang;Kim, Sitae
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.197-203
    • /
    • 2014
  • In this paper, the effect of unsteady radiation on the horizontal fin of an external fuel tank by flame of a flying flare was analysed to see the temperature increase of the fin and the thermal impact on the fin. Radiation between two surfaces was calculated using the concept of radiation resistance of surface and space including radiation, irradiation and shape factor for two flying trajectories of a flare, maximum temperature of 2200 K, emissivity of 0.95, flying velocity of 30 m/s, and thermal surface area of $0.01m^2$. The result shows that the temperature increase of the fin is 0.236 K, and the thermal effect on the fin is ignorable. And it was found that temperature is increased a little because small amount of heat energy can be radiated due to the short exposure time to the heat source.

Natural Convection Heat Transfer from a Horizontal Heat Exchanger Tube with a Fin (單一핀을 가진 水平管에서의 自然對流 熱傳達)

  • 정한식;권순석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.2
    • /
    • pp.279-286
    • /
    • 1987
  • An numerical and experimental study has been performed on natural convection heat transfer from a horizontal heat exchanger tube with a fin. At s bare tube, by increasing $C_{T}$ (tube conduction parameter), mean Nusselt number and outer wall temperature are apparently increased at $C_{T}$.leq.300, slightly increased at $C_{T}$>300 and they can be represented in an exponential function of $C_{T}$. Natural convection heat transfer characteristics for the tube with a fin at given Rayleigh number are well agreed by those for an isothermal cylinder at a modified Rayleigh number. The local fin Nusselt number of the tube with a downward fin is much higher than that of the tube with an upward fin. The comparisons between numerical and experimental results showed good agreement.reement.

A Kinematic Comparison of Start Motion Between the Swimming and Fin-Swimming (수영과 핀수영 스타트 동작의 운동학적 비교)

  • Kim, Seung-Kwon
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.1
    • /
    • pp.97-105
    • /
    • 2008
  • The kinematic variables for swimming and fin-swimming start motions were analyzed and compared using 3-dimensional cinematography. For the swimming start, the arm segment moved towards the upper rear and trunk towards the upper front followed by a descent towards the lower front, while the fin-swimming start motion showed movement towards the lower front for all segments. The total body center of gravity for the swimming start showed horizontal movement far to the front followed by a rapid descent while the fin-swimming start showed close movement towards the lower front in a short period of time. Upon entering the water, the center of gravity for swimming showed high vertical velocities while fin swimming had high horizontal velocities. For both swimming and fin swimming, the upper extremity velocity had more influence on the total center of gravity velocity than the lower extremities. Flexion of the hip joint was observed before the jump for the fin swimming start while the swimming start showed two flexions in mid-air succeeding the jump. The flexion and extension movements at the knee joint during the fin-swimming start motion were shown to be larger and more rapid than those of fin-swimming.

An Experimental Study on Natural Convection from a Conducting Tube with Two Axial Fins to a Surrounding Cylinder (두개의 축방향핀을 가진 전도관과 원통사이의 자연대류에 관한 실험적 연구)

  • Ahn, C.R.;Chung, T.H;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.1
    • /
    • pp.26-33
    • /
    • 1991
  • An experimental study has been performed on the heat transfer by the natural convection from a conducting tube with two axial fins to a surrounding cylinder. In case of vertical fins, the maximum local Nusselt number of conducting tube appears at ${\theta}{\fallingdotseq}145^{\circ}$ and that of outer cylinder appears at ${\theta}=0^{\circ}$, for $l_F=0.3$. In case of horizontal fins, the maximum local Nusselt number of conducting tube appears at ${\theta}=180^{\circ}$ and that of outer cylinder appears at ${\theta}=0^{\circ}$. The local Nusselt number of the upper fin and the downward fin shows negative values for $l_F=1.0$. The local Nusselt number of the lower fin and the downward fin shows higher values than that of the upper fin and the upward fin. The mean Nusselt number of conducting tube in case of vertical fins are increased in order of $l_F=0.6$, 0.3, 1.0 and 0.0, but in case of horizontal fins, in order of $l_F=1.0$, 0.6, 0.3, and 0.0. The mean Nusselt number of outer cylinder in case of vertical fins are increased in order of $l_F=1.0$, 0.0, 0.3 and 0.6, but in case of horizontal fins, in order of $l_F=0.6$, 1.0, 0.3, and 0.0.

  • PDF

Experimental Studies on the Evaporative Heat Transfer Characteristics of CO2/Propane Refrigerant Mixtures in Horizontal Smooth and Micro-fin Tubes (이산화탄소/프로판 혼합냉매의 수평평활관 및 마이크로 핀관에서의 증발열전달에 관한 실험적 연구)

  • Cho, Jin-Min;Kim, Yong-Jin;Kim, Min-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.4
    • /
    • pp.290-299
    • /
    • 2008
  • Evaporation heat transfer characteristics of $CO_2$/propane mixtures in horizontal smooth and micro-fin tubes have been investigated by experiment. The experiments were carried out for several test conditions of mass fluxes, heat fluxes, compositions of $CO_2$/propane refrigerant mixtures and tube geometries. Direct heating method was used for supplying heat to the refrigerant where the test tube was uniformly heated by electric current which was applied to the tube wall. Heat transfer coefficient data during evaporation process of $CO_2$/propane mixtures were measured for 5 m long smooth and micro-fin tubes with outer diameters of 5 mm, respectively. The tests were conducted at mass fluxes of 318 to 997 $kg/m^2s$, heat fluxes of 6 to 20 $kW/m^2$ and for several mixture compositions (100/0, 75/25, 50/50, 25/75, 100/0 by wt% of $CO_2$/propane). The differences of heat transfer characteristics between smooth and micro-fin tubes for various compositions of $CO_2$/propane refrigerant mixtures and the effect of mass flux, and heat flux on enhancement factor (EF) and penalty factor (PF) were presented.

Analysis on the Circumference Wall Temperature in a Long Horizontal Pipe with Thermal Stratification

  • Ahn, Jang-Sun;Ko, Yong-Sang;Kim, Yu-Hwan;Park, Byeong-Ho;Kim, Eun-Kee
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.364-370
    • /
    • 1995
  • The One-dimensional fin model is used to analyze the angular wall temperature variation of long horizontal lines, where stratification could result in top-to-bottom differences in wall temperatures. The top and bottom sections are treated separately and coupled by boundary conditions. The thermal stratification analysis is focused on the effects of the heat transfer rates at the pipe surface. The results show that the heat transfer rate at the pipe surface is the controlling parameter which reduce significantly the temperature difference in pipe circumferential direction. The one-dimensional fin modelling analysis results are verified by comparison with the operating PWR test data. The circumferential temperatures of pipe calculated by one-dimensional fin modelling agree well with the PWR plant test data.

  • PDF

Conjugate Heat Transfer by Natural Convection from a Horizontal Heat Exchanger Tube with a Long Vertical Longitudinal Plate Fin (단일(單一) 긴 수직평판(垂直平板)핀을 가진 수평전도관(水平傳導管)으로 부터의 자연대류(自然對流))

  • Bai, Dai Sok;Kwon, Sun Sok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.1
    • /
    • pp.64-72
    • /
    • 1989
  • Laminar natural convection heat transfer from a horizontal heat exchanger tube with one infinitely long vertical plate fin has been studied by a finite-difference numerical procedure. In predicting convective heat transfer from a circular tube, the thermal boundary condition at solid fluid interface is usually assumed to be isothermal. However, in reality, the thermal boundary condition is not isothermal, and the tube has the thickness and the conductivity. So the temperature at the interface is not known a priori to the calculation. This problem has the conjugate phenomena which occur between the tube conduction and external natural convection, and between the fin conduction and external natural convection. Numerical results are obtained to determine the effects of the conductivity of solid wall and the thickness of tube wall on heat transfer. It is found that the conduction causes significant influence on the natural convection heat transfer at low K and high ${\delta}$.

  • PDF

Evaporating Heat Transfer Characteristics of R-290, R-600a Inside Horizontal Double Pipe Heat Exchangers (R-290, R-600a의 수평 이중관형 열교환기내 증발 특성)

  • 홍진우;노건상;권옥배;박기원;오후규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.309-314
    • /
    • 2000
  • Experimental results for heat transfer characteristics of natural refrigerants R-290, R-600a and HCFC refrigerant R-22 during evaporating inside horizontal double pipe heat exchangers are presented. The experimental apparatus is basically a vapour heat pump system, composed of a compressor, a condenser, expansion devices, a evaporator, and some other peripheral devices. The test sections were horizontal double pipe heat exchangers, which were a pair of smoothed tube, having 10.07 mm ID, 12.07 mm OD, and grooved inner fin tube, having 12.70 mm OD, 0.25 mm fin height, and 75 fins. The local evaporating heat transfer coefficients of natural refrigerants were not much affected with the mass velocity than R-22 and it could be interpreted that the local evaporating heat transfer coefficients of R-22 were increased more than those of R-290, R-600a according to the increment of mass velocity. Moreover, the maximum increment of the heat transfer coefficient was found in R-290. The average heat transfer coefficient was obtained the maximum value in R-290 and the minimum value in R-22. It reveals that the natural refrigerant can be used as a substitute for R-22. In the grooved inner fin tube, 70% of the increment of the heat transfer coefficient was obtained compared to the smoothed tube.

  • PDF