• Title/Summary/Keyword: Homogeneity Index

Search Result 170, Processing Time 0.032 seconds

The comparison of treatment planning between stereotactic radiosurgery planning systems (정위방사선수술 치료계획시스템간의 치료계획비교)

  • 김기환;조문준;김재성;김준상;신교철;김진기;오영기;정동혁;김정기
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.171-175
    • /
    • 2001
  • We analyze the relation of dose volume histogram, conformity index and homogeneity index based on RTOG9005 for treatment planning result between framed based stereotactic radiosurgery(SRS) system and frameless SRS/T system to verify the difference of two systems in the intracranial target. There is same treatment planning result by two treatment planning systems.

  • PDF

Homogeneity of Climate Aridity Index Trends Using Mann-Kendall Trend Test (Mann-Kendall 추세분석을 이용한 건조지수 추세의 동질성)

  • Rim, Chang-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.7
    • /
    • pp.643-656
    • /
    • 2014
  • The homogeneity analysis of temporal (monthly, seasonal and annual) climate aridity index trend was accomplished for 43 climate measurement stations in South Korea. Furthermore, 43 stations were grouped into 9 different regions and the temporal and regional homogeneity of climate aridity index trends in each region and entire 9 regions were analyzed. For analysis, monthly, seasonal and annual climate aridity indexes of 43 study stations were estimated using precipitation and potential evapotranspiration calculated from FAO Penman-Monteith equation. The Mann-Kendall statistical test for significant trend was accomplished using the estimated climate aridity indexes and the results of trend test (Z scores) were used to analyze the temporal and regional homogeneity of climate aridity index trends. The study results showed the temporal and regional homogeneity of climate aridity index trends for individual and entire 9 regions. However, the homogeneity and the extent of aridity index trend showed different patterns temporally and regionally.

A Simple Scoring Method to Calculate the Homogeneity and Coverage Indices of Dose Volume Histogram (DVH를 이용한 선량 균등률 및 덮임률 지수에 관한 연구)

  • Yoon Myong-Geun;Park Sung-Yong;Shin Dong-Ho;Park Jung-Hun;Lee Se-Byeong;Kim Dae-Yong;Kim Joo-Young;Cho Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.6-16
    • /
    • 2006
  • The goal of this study was to develop new indices for effectively evaluating the dose coverage and homogeneity based on the target-volume dose-volume histogram (TV-DVH) of intensity-modulated radio-therapy treatment plans. A new coverage Index and a new homogeneity index were developed by integrating a modified TV-DVH and by fitting a TV-DVH with a modified step function, respectively. The coverage index, named the l-index, indicates whether the dose coverage for the target volume is adequate based on user-defined criteria. A lower l-index indicates higher dose coverage of the tumor volume. The index for assessing dose homogeneity in a target volume, named the n-index, is more accurate than the conventional method in evaluating the dose homogeneity in a tumor volume. The baseline treatment plan for a target volume coverage and homogeneity is discussed. The proposed simple indices have been demonstrated to be effective in evaluating the dose coverage and homogeneity for TV-DVHs.

  • PDF

Effect of Processing Conditions on the Homogeneity of Partially Degummed Silk Evaluated by FTIR Spectroscopy

  • Kim, Hyun Ju;Chung, Da Eun;Um, In Chul
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.26 no.1
    • /
    • pp.54-60
    • /
    • 2013
  • The partial degumming of silk has recently attracted researchers' attention because of its ability to produce silk textiles with new tactile properties, intermediate between the softness of fully degummed silk and the hardness of raw silk. However, it is difficult to obtain partially degummed silk in a homogenously degummed state due to the heterogeneous character of sericin removal. It is also difficult to examine the homogeneity of degumming. In the present study, Fourier transform infrared (FTIR) spectroscopy with attenuated total reflection (ATR) geometry was used to evaluate the effect of processing conditions on the degumming of silk yarns. The crystallinity index, calculated from FTIR spectra, showed an increase with the degumming ratio. Therefore, the homogeneity of degumming could be evaluated by the variation of crystallinity index for 30 different spots in silk yarns. The homogeneity of degumming was influenced by the total degumming time, the content of surfactant, and the liquor rate. No effect was observed upon changing the number of degumming cycles at the same total degumming time.

Research for Lateral Penumbra and Dose Distribution When Air Gap Changing in Proton Therapy Case (양성자치료시 Air Gap 변화에 따른 Lateral Penumbra와 선량분포 변화에 대한 비교 및 연구)

  • Kim, Jae-Won;Sim, Jin-Seob;Jang, Yo-Jong;Kang, Dong-Yun;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.47-51
    • /
    • 2010
  • Purpose: In the treatment of high-energy protons Air gap (the distance between the patient and the exit Beam) Lateral Penumbra of the changes to the increase in the radiation fields can form unnecessary and Increase the maximum dose at the site of treatment and reduced the minimum dose homogeneity of dose distributions can decline. Air gap due to this change in dose distribution compared to investigate studied. Materials and Methods: Received proton therapy at our institution Lung, Liver patients were selected and the size of six other Air gap in Field A and Field B 2, 4, 6, 8, 10 cm Proton external beam planning system by setting up a treatment plan established. Air gap according to the Lateral Penumbra area and DVH (Dose Volume Histogram) to compare the maximum dose and minimum dose of PCTV areas were compared. In addition, the dose homogeneity within PCTV Homogeneity index to know the value and compared. Results: Air gap (2, 4, 6, 8, 10 cm) at each change in field size were analyzed according to the Lateral Penumbra region Field A Change in the Air gap 2~10 cm by 1.36~1.75 cm, the average continuously increased about 28.7% and Field B Change in the Air gap 2~10 cm by 1.36~1.75 cm, the average continuously increased about 31.6%. The result of DVH analysis for relative dose of the maximum dose According to Air gap 2~10 cm is the mean average of 110.3% from 108.1% to a sustained increased by approximately 2.03% and The average relative dose of minimum dose is the mean average of 93.9% percent to 90.8 percent from the continuous decrease of about 3.31 percent. The result of Homogeneity index value to the according to Air gap 2~10 cm is the 2-fold increase from 1.09 to 2.6. Conclusion: In proton therapy case, we can see the increasing of lateral penumbra area when airgap getting increase. And increasing of Dmax and decreasing Dmin in the field are making increase homogeneity index, So we can realize there are not so good homogeneity in the PCTV. Therefore we should try to minimize air gap in proton therapy case.

  • PDF

Effect of Surfactant on Homogeneity of Partially Degummed Silk Fiber

  • Chung, Da Eun;Um, In Chul
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.28 no.1
    • /
    • pp.19-24
    • /
    • 2014
  • Silk has always been one of the most favored textile materials. Fully degummed silk fiber (i.e., silk fibers without sericin) shows better luster than raw silk fiber (with sericin); it is also softer. On the other hand, raw silk fiber feels cooler because of the presence of sericin, making it useful as a textile for the summer season. Recently, partially degummed silk has attracted researchers' attention because it provides better luster, feel, and dyeing properties. However, the partial degumming of silk is very difficult because it results in inhomogeneously degummed fiber. In the present study, silk yarns were degummed with surfactant aqueous solutions and the effects of each surfactant on the degumming ratio, crystallinity, and homogeneity of the degummed silk yarn were examined. The degumming ratio and crystallinity index of silk yarn varied depending on the type of surfactant. On the whole, anionic surfactants resulted in higher degumming ratios and better homogeneity than nonionic surfactants.

A Study on the Homogeneity of Powder Mixture (분말약품 혼합의 균일성에 관한 연구)

  • 김길수;이민화
    • YAKHAK HOEJI
    • /
    • v.21 no.2
    • /
    • pp.95-100
    • /
    • 1977
  • The effects of the particle size on the homogeneity of mixing and segregation of caffeine-lactose (1:99) mixture were studied. Using the two kinds of caffein, milled and unmilled caffein, V-type blender, the degree of mixing according to the particle size was predicted and the experiment on the change of mixedness by mixing time was carried out by the method derived from mixing index theory by Poole et al. and Hersey. the results could be summarized as follows; (1) The homogeneity of mixing was greatly affected by the particle size and the particle size should be reduced to the adepuate level to attain the desirable mixedness. (2) The homogeneity was not proportional to the mixing time and optimum mixing time for caffein-lactose was about 10 minutes. (3) Segregation tendency was increased by the particle size increase and greatly affected by the flow time in the segregation cell.

  • PDF

Comparison treatment planning with the measured change the dose of each Junction section according to the error of setup CSI Treatment with Conventional, IMRT, VMAT (Conventional, IMRT, VMAT을 이용한 CSI 치료시, Setup 오차에 따른 각 Junction부의 선량변화측정을 통한 치료계획 비교)

  • Lee, Ho Jin;Jeon, Chang Woo;Ahn, Bum Suk;Yu, Sook Hyeon;Park, So Yeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.217-224
    • /
    • 2014
  • Purpose : Conventional, IMRT, at CSI treatment with VMAT, this study compare the treatment plan with dose changes measured at Junction field according to the error of Setup. Materials and Methods : This study established Conventional, the IMRT, VMAT treatment planning for CSI therapy using the Eclipse 10.0 (Eclipse10.0, Varian, USA) and chose person in Seoul National University Hospital. Verification plan was also created to apply IMRT QA phantom for each treatment plan to the film measurements. At this time, the error of Setup was applied to the 2, 4, 6mm respectively with the head and foot direction. ("+" direction of the head, "-" means that the foot direction.) Using IMRT QA Phantom and EBT2 film, was investigated by placing the error of Setup for each Junction. We check the consistency of the measured Film and plan dose distribution by gamma index (Gamma index, ${\gamma}$). In addition, we compared the error of Setup by the dose distribution, and analyzing the uniformity of the dose distribution within the target by calculating the Homogeneity Index (HI). Results : It was figured out that 90.49%-gamma index we obtained with film is agreement with film scan score and dose distribution of treatment plan. Also, depend on the dose distribution on distance, if we make the error of Setup 2, 4, 6mm in the head direction, it showed that 3.1, 4.5, 8.1 at $^*Diff$(%) of Conventional, 1.1, 3.5, 6.3 at IMRT, and 1.6, 2.5, 5.7 at VMAT. In the same way, if we make the error of Setup 2, 4, 6mm in the foot direction, it showed that -1.6, -2.8, -4.4 at $^*Diff$(%) of Conventional, -0.9, -1.6, -2.9 at IMRT, and -0.5, -2.2, -2.5 at VMAT. Homogeneity Index(HI)s are 1.216 at Conventional, 1.095 at IMRT and 1.069 at VMAT. Discussion and Conclusion : The dose-change depend on the error of Setup at the CSI RT(radiation therapy) using IMRT and VMAT which have advantages, Dose homogeneity and the gradual dose gradients on the Junction part is lower than that of Conventional CSI RT. This a little change of dose means that there is less danger on patients despite of the error of Setup generated at the CSI RT.

Iterative SAR Segmentation by Fuzzy Hit-or-Miss and Homogeneity Index

  • Intajag Sathit;Chitwong Sakreya;Tipsuwanporn Vittaya
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.111-114
    • /
    • 2004
  • Object-based segmentation is the first essential step for image processing applications. Recently, SAR (Synthetic Aperture Radar) segmentation techniques have been developed, however not enough to preserve the significant information contained in the small regions of the images. The proposed method is to partition an SAR image into homogeneous regions by using a fuzzy hit-or-miss operator with an inherent spatial transformation, which endows to preserve the small regions. In our algorithm, an iterative segmentation technique is formulated as a consequential process. Then, each time in iterating, hypothesis testing is used to evaluate the quality of the segmented regions with a homogeneity index. The segmentation algorithm is unsupervised and employed few parameters, most of which can be calculated from the input data. This comparative study indicates that the new iterative segmentation algorithm provides acceptable results as seen in the tested examples of satellite images.

  • PDF