• Title/Summary/Keyword: Homeotropic polymer

Search Result 27, Processing Time 0.02 seconds

EO Characteristic in the Advanced Vertical Alignment (VA)- π Cell a Homeotropic Blended Polymer (수직 복합폴리머 표면을 이용한 Advanced VA-π cell의 전기 광학 특성)

  • 황정연;이경준;조용민;서대식
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.9
    • /
    • pp.826-832
    • /
    • 2003
  • Blending effects for generating a pretilt angle in nematic liquid crystal (NLC) with negative dielectric anisotropy on the blended polyimide (PI) of homeotropic and homogeneous alignment surface were studied. Also, we investigated the EO performances for the advanced VA- $\pi$ cell using this homeotropic blended PI surface. A many decrease of tilt angle on the polymer surface to blend homeotropic PI and homogeneous PI with side chain type was measured, and the tilt angle decreased as blended ratio and rubbing strength increase. However, a small decrease of tilt angle on the polymer surface to blend homeotropic PI and homogeneous PI with main chain type was measured. The blended effects for generating a pretilt angle were clearly observed, and the many decrease of tilt angle can be achieved by using the blended PI surface. The electro-optical (EO) characteristics using the advanced VA- $\pi$ cell using the homeotropic blended PI surface than that of conventional VA cell can be improved. We suggest that the developed advanced VA-$\pi$ cell on a homeotropic blended PI surface is a promising technique for the achievement of a fast response time, and a high contrast ratio.

EO Characteristics in the Vertical Alignment (VA)-$\pi$ mode LCD Using the Tilt Angle Decrease Effect on the Blended Polymer (혼합된 polymer에서의 틸트 감소 효과를 이용한 VA-$\pi$ mode LCD의 전기광학 특성)

  • Lee, Kyung-Jun;Hwang, Jeoung-Yeon;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05d
    • /
    • pp.53-56
    • /
    • 2003
  • Blending effects for generating a pretilt angle in nematic liquid crystal (NLC) with negative dielectric anisotropy on the blended polyimide (PI) of homeotropic and homogeneous alignment surface were studied. Also, we investigated the EO performances for the advanced VA-$\pi$ cell using this homeotropic blended PI surface. A many decrease of tilt angle on the polymer surface to blend homeotropic PI and homogeneous PI with side chain type was measured, and the tilt angle decreased as blended ratio and rubbing strength increase. The blended effects for generating a pretilt angle were clearly observed, and the many decrease of tilt angle can be achieved by using the blended PI surface. The electro-optical (EO) characteristics using the advanced VA-$\pi$ cell using the homeotropic blended PI surface than that of conventional VA cell can be improved. We suggest that the developed advanced VA-$\pi$ cell on a homeotropic blended PI surface is a promising technique for the achievement of a fast response time, and a high contrast ratio.

  • PDF

Study of Homeotropic Liquid Crystal Characteristics Using Photo-polymer and Homeotropic Polyimide Blended Alignment Layer via UV Irradiation Method (UV 광배향법을 통한 광폴리머와 수직 폴리이미드 혼합 배향막의 수직 배향 특성 연구)

  • Lee, Jin-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.12
    • /
    • pp.996-999
    • /
    • 2012
  • From UV irradiation, we achieved homeotropic liquid crystal alignment on blended photo-polymer layer which is composed of polyvinyl-cinnamate (PVCi) and homeotropic polyimide (PI). From vertical alignment (VA) mode, we measured threshold voltages by various PVCi doping concentration. Also, the rise time and fall time of VA cells were measured to verify the best doping concentration. Transmittance curves showed about 70% value between 380 nm and 780 nm wavelength which mean visible region.

EO Characteristics in the Advanced Vertical Alignment VA-$\pi$ Cell on a Homeotropic Blended Polymer (수직 복합 폴리머 표면을 이용한 Advanced VA-$\pi$ cell의 전기광학 특성)

  • Lee, Kyung-Jun;Hwang, Jeoung-Yeon;Hahn, Eun-Joo;Paek, Seung-Kwon;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.530-533
    • /
    • 2002
  • Blending effects for generating a pretilt angle in nematic liquid crystal (NLC) with negative dielectric anisotropy on the blended polyimide (PI) of homeotropic and homogeneous alignment surface were studied. Also, we investigated the EO performances for the advanced VA-$\pi$ cell using this homeotropic blended PI surface. A many decrease of tilt angle on the polymer surface to blend homeotropic PI and homogeneous PI with side chain type was measured, and the tilt angle decreased as blended ratio and rubbing strength increase. The blended effects for generating a pretilt angle were clearly observed, and the many decrease of tilt angle can be achieved by using the blended PI surface. The electro-optical (EO) characteristics using the advanced VA-$\pi$ cell using the homeotropic blended PI surface than that of conventional VA cell can be improved. We suggest that the developed advanced VA-$\pi$ cell on a homeotropic blended PI surface is a promising technique for the achievement of a fast response time, and a high contrast ratio.

  • PDF

Electro-optical Characteristics of a Multi-domain Vertical-alignment Liquid Crystal Display on Homeotropic Photopolymer Layer

  • Hwang, Jeoung-Yeon;Lee, Kyung-Jun;Seo, Dae-Shik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.511-513
    • /
    • 2002
  • Electro-optical characteristics of new multi-domain vertical-alignment (MVA) liquid crystal displays (LCDs) with negative dielectric anisotropy on a homeotropic photopolymer were studied. Good voltage-transmittance (V-T) curves by the new MVA-LCD on the homeotropic photo-polymer were obtained. Also, the stable response time of MVA-LCD on the homeotropic photopolymer can be achieved. The viewing angle of the new MVA-LCD could be improved by the grating groove with UV exposure and development on the photo-polymer.

  • PDF

Study on the LC Alignment on Vertical Alignment Polymer Surface using the AFM (AFM을 이용한 수직배향막 폴리머 표면위의 액정배향에 관한 연구)

  • 김완철;송선애;전일철;이종문;이승희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.6
    • /
    • pp.510-514
    • /
    • 2003
  • We have studied the alignment of liquid crystals (LCs) on homeotropic polymeric surface that is scanned using an atomic force microscope (AFM) tip by optical polarizing microscopy and computer simulation. The scanned areas on one substrate are 5 $\mu\textrm{m}$ ${\times}$ 5 $\mu\textrm{m}$, 10 $\mu\textrm{m}$ ${\times}$ 10 $\mu\textrm{m}$, and 20 $\mu\textrm{m}$ ${\times}$ 20 $\mu\textrm{m}$ and this substrate is assembled to another substrate coated. with homeotropic polymer. The fabricated micro-LC cell using two substrates does not show any hysteresis and disclination lines inside the nano-rubbing areas, while changing voltage up and down. This indicates that the pretilt angle exists in the areas, thereby forming a hybrid LC configuration. From the experimental and computer simulation results, we can understand that the AFM rubbing clearly changes surface status of homeotropic alignment layer and causes the pretilt angle to an initial scanning direction.

Tilt Angle Generation in NLC on Homeotropic Polymer Surface with Ion Beam Irradiation as a Function of Incident Angle

  • Lee, Sang-Keuk;Seo, Dae-Shik;Choi, Dai-Seub
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.3
    • /
    • pp.120-122
    • /
    • 2008
  • We have studied the tilt angle generation on the homeotropic polyimide (PI) surface using a low intensity ion beam source as a function of incident angle. An excellent LC alignment of nematic liquid crystal (NLC) on the PI surface with ion beam exposure for all incident angles was observed. The tilt angle of NLC on the homeotropic PI surface for all incident angles was from 90 to 88 degree was observed. Also the tilt angle of NLC on the homeotropic PI surface with ion beam exposure of 400 eV had a tendency to increase as ion beam energy incident angle become more instance from 45 degree. Finally, a good LC alignment thermal stability on the homeotropic PI surface with ion beam exposure can be achieved.

Pretilt Angle Generation for Nematic Liquid Crystal on a Homeotropic Alignment Layer (수직배향층에서의 네마틱액정의 프리틸트각 발생)

  • 서대식;김형규;이승희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.2
    • /
    • pp.130-132
    • /
    • 2001
  • The mechanisms of pretilt angle generation in nematic liquid crystal (NLC) with negative dielectric anisotropy on a rubbed polyimide (PI) surface for homeotropic alignment were studied. The pretilt angle of negative type NLC was smaller than that of the positive type NLC for all rubbing strength regions on the rubbed PI surface. The pretilt angle generated in NLC does not attributable to steric interaction between the fluorine moiety of NLC and the polymer surface on the rubbed PI surface. Consequently, the mechanism of the pretilt angle generation for homeotropic alignment is different from the one for homogeneous alignment.

  • PDF

Control of High Pretilt Angle for Nematic Liquid Crystal of Negative Dielectric Anisotropy on Blending Polymer Surfaces (복합 폴리머 표면에서의 부의 유전율을 가진 네마틱액정의 고프리틸트각 제어)

  • 황정연;서대식;남상회
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.12
    • /
    • pp.1023-1026
    • /
    • 2001
  • The control of high pretilt angle for nematic liquid crystal (NLC) with negative dielectric anisotropy on the rubbed blending polyimide (PI) of homeotropic and homogeneous alignment surface was studied. High LC pretilt angle on the rubbing blending polyimide of homeotropic PI and SE-7492 surface was measured and the LC pretilt angle increased wish blending ratio and rubbing strength. However, the low LC pretilt angle on the rubbed blending polyimide of homeotropic PI and SE-150 surface was measured. The high pretilt angle of NLC can be achieved by using the blending PI surface.

  • PDF