• Title/Summary/Keyword: Hollow-fiber Membrane

Search Result 425, Processing Time 0.029 seconds

Application and Development of Dehumidication Systems - Focusing on Membrane Dryer (제습시스템의 응용과 발전 - Membrane Dryer를 중심으로)

  • 남상용;임지원;황해영;하성용
    • Membrane Journal
    • /
    • v.14 no.1
    • /
    • pp.1-17
    • /
    • 2004
  • Dehumidification systems have been developed for the various applications, especially for the production of dry compressed air. Compressed air producing system attach $\varepsilon$ d with dehumidification unit have advantages such as high reliability, low error ratio, comfortable working conditions, etc. Conventional dehumidification systems have several economical drawbacks like high electric cost, high cost of adsorbent and it is not environmentally friendly system because freezing agent like a Freon has been used. Membrane dryer is emerging system which have economical advantages and environmental merits.

Membrane Contactors for Water Carbonation

  • Alessandra Criscuoli;Enrico Drioli
    • Korean Membrane Journal
    • /
    • v.1 no.1
    • /
    • pp.59-64
    • /
    • 1999
  • A theoretical and experimental study made in order to determine the performance of mem-brane contactors in water carbonation is presented. In particular on the basis of experimental results pre-viously obtained it has been derived an expression in which the effect of some parameters as temprera-ture water and {{{{{CO }_{2 } }}}}} flow rate {{{{{CO }_{2 } }}}}} pressure trans-membrane pressure on the performance of the process is taken into account. The study refers to hollow fiber membrane contactors used for the experimental tests. The main scope has been to verify if by membrane contactors it is possible to reach the same de-gree of water carbonation as by trditional methods (1-5 g/1) and to derive for the module used a cor-relation able to describe the performance of the process at several operating conditions. The high {{{{{CO }_{2 } } }}}} removal observed confirms the interesting potentialties of membrane contactors also in gas streams purification.

  • PDF

STATUS OF MEMBRANE TECHNOLOGY IN KOREA

  • Im, Hoagy-K;Won, Jang-mook
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1999.07a
    • /
    • pp.3-7
    • /
    • 1999
  • Government efforts on membrane technology started in early 1980 with Membrane Development Program supported by the Ministry of Science and Technology. Several independent research projects on liquid separation, gas separation, hollow fiber producing program etc. were carried out during the 1980s. The RaCER was commissioned by MOCI for the general management of the project which had its aims in establishing the base for developing membranes, modules and systems for liquid separation in August 1993. More recently, in June 1995, a program for developing membranes for oxygen separation, nitrogen separation and hydrogen separation was initiated. This paper outlines the brief history of membrane technology development in Korea from the introduction of membrane filtration technology during the late 1960s to present.

  • PDF

Gas Transfer and Hemolysis Characteristics of a New Type Intravenous Lung Assist Device (혈관 내 신형 폐보조장치의 기체전달 및 용혈 특성)

  • 김기범;권대규;정경락;이삼철
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.2
    • /
    • pp.121-126
    • /
    • 2003
  • The purpose of this work was to assess and quantify whether the beneficial effects in long-term gas exchange at exciting frequency were obtained at different frequencies as well and then to develop a vibrating intravascular lung assist device(VIVLAD), for Patients suffering from acute respiratory distress syndrome(ARDS) or chronic respiratory problems. We investigate the optimal condition of the frequency band excited with new vibrator at state of limit hemolysis when blood hemolysis came to through a membrane vibration action. The experimental design and procedures were given for a device used to assess the effectiveness of membrane vibrations. Quantitative experimental measurements were performed to evaluate the performance of the device . and to identify membrane vibration dependence on blood hemolysis. We developed an analytical solution for the hydrodynamics of flow through a bundle of sinusoidally vibrated hollow fibers that is used to provide some insight into how wall vibrations might enhance the performance of the VIVLAD. In the result, it was measured that the effect of various excited frequencies in gas transfer rate and hemolysis from the maximum gas transfer rate at no vibration when the maximum gas transfer rates showed at module type 6, module type 6 consisted of 675 hollow fiber membranes The maximum oxygen transfer rate was caused by the occurrence of maximum amplitude and transfer of vibration to hollow fiber membranes when it was excited by the frequency band of 7Hz at each blood flow rate. because this frequency became the End mode resonance frequency of the flexible in blood flow. Also, when module type 6 was excited at an excited frequency of 7Hz. blood hemolysis was low. Therefore, we decided that the limit of hemolysis frequency is 7Hz . because maximum amplitude occurred at this frequency.

A Study on the Liquid-Liquid Extraction by Use of Hydrophobic Hollow Fiber Module (소수성 중공사 모듈에 의한 액-액 추출에 관한 연구)

  • Kim, Young-II;Park, Dong-Won
    • Applied Chemistry for Engineering
    • /
    • v.7 no.2
    • /
    • pp.237-244
    • /
    • 1996
  • Liquid-liquid extractions by use of microporous hollow fiber modules are fast compared with conventional extraction equipment because of the large surface area per volume. In these modules, the extractant and feed can be contacted at high speed and two flows are completely independent, so there are no problems with loading and channeling. In this paper, it was investigated the extraction selectivities for liquid-liquid extraction of Fe(II) and Ni(II) from dilute aqueous solution into TOA (tri-n-octylamine) and EHPNA (bis(2-ethylhexyle)hydrogenphosphite) as organic extractants by using the hydrophobic hollow fiber module. To determine the rate controlling step for mass transfer in hollow fibers, we also examined the effect of inside and outside flow rates of the hollow fiber module. From these experiments, we identified for the extraction of system with high partition coefficient in hydrophobic hollow fibers, mass transfer in the inside aqueous feed dominated the overall mass transfer, and in this paper, correlation between $K_w$ and $v_t$ was obtained as $K_w{\frac{d}{D}}=6.22\(\frac{d^2v_t}{LD}\)^{1/3}$ On the other hand, for the system with low partition coefficient, the resistance in the inside of hollow fibers was much less than membrane resistance because the extraction was not simple in the micropore. Thus, for systems with high partition coefficients, hydrophobic hollow fibers would be a better choice.

  • PDF

Preparation of Chemical and Fouling Resistant Semicrystalline Membranes (내식성, 내오염성 결정성 고분자 분리막의 제조)

  • 유종범;송기국;김성수
    • Polymer(Korea)
    • /
    • v.24 no.3
    • /
    • pp.342-349
    • /
    • 2000
  • Hollow fiber membranes were prepared via thermally-induced phase separation process followed by stretching process from isotactic polypropylene and soybean oil system. Various operating parameters were examined in terms of their effects on the structure variation and performances of the membrane, and were optimized. Melt viscosity of the melt sample had influence on the formation of the microfibrils, and addition of nucleating agent increased the nucleation density to enhance the interspherulitic pore formation by stretching. Annealing the membrane at its stretched state relaxed the stress induced by stretching and helped the membrane maintain the stretched structure without shrinking. Solid-liquid Phase separation is more prevalent when the nucleating agent was added, and coagulation bath temperature determined the nucleation density, which affected the pore formation by stretching. In the absence of nucleating agent, nucleation was not effective and liquid-liquid phase separation governed the structure formation, which showed the opposite trend to that of the case with nucleating agent.

  • PDF

Enhancement of Mass Transfer Using Piezoelectric Material in Fluid Flow System

  • Kim, Gi-Beum;Chong, Woo-Suk;Kwon, Tae-Kyu;Hong, Chul-Un;Kim, Nam-Gyun;Jheong, Gyeong-Rak
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.165-170
    • /
    • 2004
  • The purpose of this work was to assess and quantify the beneficial effects of long-term gas exchange, at varying frequencies, for the development of a vibrating intravascular lung assistance device (VIVLAD), for patients suffering from acute respiratory distress syndrome (ARDS). The experimental design and procedure have been applied to the construction of a new device for assessing the effectiveness of membrane vibrations. An analytical solution has been developed for the hydrodynamics of flow through a bundle of sinusoidally vibrated hollow fibers, with the intention of gaining insight into how wall vibrations might enhance the performance of the VIVLAD. As a result, the maximum oxygen transfer rate was reached at the maximum amplitude and through the transfer of vibrations to the hollow fiber membranes. The device was excited by a frequency band of 7Hz at various water flow rates, as this frequency was the 2nd mode resonance frequency of the flexible beam. 675 hollow fiber membranes were also bundled, within the blood flow, into the device.

  • PDF

A Study on the Membrane Fouling Control by Ozone-Scrubbing (오존세정(洗淨)에 의한 막(膜) 폐색(閉塞) 억제(抑制)에 관한 연구(硏究))

  • Kim, Hyung-Soo;Fujita, Kenji
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.3
    • /
    • pp.78-87
    • /
    • 1995
  • A study on the fouling control by periodical ozone-scrubbing was conducted in a membrane filtration process for drinking water treatment. Hydrophilic hollow fiber polyethylene membrane with pore size of $0.1{\mu}m$ and its surface area of $0.42m^2$ was used. Dead-End filtration method was selected to obtain high efficiency of energy. Laboratory prepared synthetic raw water with kaolin was used and the membranes were scrubbed by ozone once in an hour and once in two hours. When the duration of ozone scrubbing was increased from 10 seconds to 20 seconds, the rate of membrane fouling was significantly decreased. Although the frequency of ozone-scrubbing was reduced from once in an hour to once in two hours. the effect of fouling control was unchanged. However, ozone-scrubbing was not effective after a membrane was fouled and washed with detergent for reuse. Among several possible working effects of ozone, bactericidal effect was confirmed to be the primary reason of fouling control.

  • PDF

THE REVERSE OSMOSIS PROCESS

  • Erickson, Steve
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1991.04a
    • /
    • pp.9-9
    • /
    • 1991
  • This paper will begin by describing osmosis and how reverse osmosis works. It will show how osmotic pressure affects reverse osmosis operations. It uill explain salt rejection, membrane flux, and recovery rates and the affect that salt built up has on membrane performance. It wil 1 explain the limitations of RO performance and why pretreatment is important. It will describe the two basic types of membrane, asymmetric and thin-film composite and explain the difference between these types plus compare cellulose acetate types to aromatic polyamide type membranes. It will discuss operating efficiences as it compares to feedwater pressure, concentration, temperature and pH. Finally, it will discuss the differences between tubular, plate and frame, hollow fiber and spiral wound element design. It will be a paper that talks about the basics of RO systems and should give a person who is unfamiliar with RO a basic introduction to this type of separation technology.

  • PDF

Effect of Addition of Cosolvent γ-Butyrolactone on Morphology of Polysulfone Hollow Fiber Membranes (폴리설폰 중공사막 구조에 대한 조용매 γ-Butyrolactone 첨가 영향)

  • Yun, Sukbok;Lee, Yongtaek
    • Applied Chemistry for Engineering
    • /
    • v.25 no.3
    • /
    • pp.274-280
    • /
    • 2014
  • Polysulfone (PSf) hollow fiber membranes were prepared via the nonsolvent induced phase separation technique. The cosolvent of ${\gamma}$-butyrolactone (GBL) was added to the polymer solution containing a mixture of PSf and N,N-dimethylacetamide (DMAc). Water was utilized as a precipitation nonsolvent. The morphology of prepared membranes was investigated using a field emission scanning electron microscopy. The fabricated membrane showed a typical asymmetric structure such as the dense layer on the porous support layer by the addition of GBL to the polymer solution. As the concentration of GBL increased, the asymmetric porous structure was shown to be more intensified. It was thought that the added GBL played a role of enhancing the liquid-liquid phase separation of the polymer solution, since the cosolvent of GBL might change the thermodynamic solubility parameter of the doping solution. Permeation properties through the prepared hollow fiber membranes were characterized by measuring the pure water flux and the solute rejection using $0.05{\mu}m$ polystyrene latex (PSL) beads. Experimental results revealed that the use of PEG as the internal coagulant enhanced the pure water flux up to 130 times compared to the use of EG while the rejection of the PSL beads decreased only 5%.