• Title/Summary/Keyword: Hollow fiber

Search Result 628, Processing Time 0.022 seconds

Analysis of Hollow Optical Fiber with Graded-Index Profile (언덕형 Hollow Optical Fiber의 전계 해석)

  • Pee, Joong-Ho;Jeong, Woo-Jin;Kim, Chang-Min
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.6
    • /
    • pp.493-499
    • /
    • 2006
  • Arbitrary graded-index HOF(Hollow Optical Fibers) are analyzed using the modified Airy function, and the corresponding eigenvalue equation that renders precise results is derived. For graded index HOF, the gradient of an evanescent field in hollow region could be adjusted more sharply than the conventional step-index HOF and the feasibility of more effective atom-guiding is confirmed.

A Study on Bonded Joints of Composite Hollow Bushing (Composite Hollow Bushing의 접합기술에 관한 연구)

  • Cho, Han-Goo;Kang, Hyung-Kyung;Yoo, Dea-Hoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.493-494
    • /
    • 2008
  • During the last years hollow core insulators started their success story in the field of high voltage engineering for electrical apparatus, substituting porcelain insulators. The termination, also named top and bottom fittings are used for the connection to the rest of the electrical apparatus. The top and bottom flange are attached to the composite to transmit mechanical load and also ensure the gas tightness. They are bonded by epoxy glue with a glass transition temperature of about $130^{\circ}C$-$150^{\circ}C$ the glass reinforced epoxy tube of filament winding. This paper describes the results of a study on the bonded joints of fiber reinforced epoxy tube and cast aluminum. This suggests that surface roughness and glue types play an important role in evaluating of gas sealing capability on the flange and fiber reinforced epoxy tube in the composite hollow bushing.

  • PDF

Cross Flow Filtration of Pichia stipitis by a Hollow Fiber Membrane (Hollow Fiber 막에 의한 Pichia stipitis의 Cross Flow여과)

  • Kim, H.;Chung, I. S.
    • KSBB Journal
    • /
    • v.4 no.1
    • /
    • pp.57-61
    • /
    • 1989
  • The feasibility of separating Pichia stipitis from a fermentation broth using a hollow fiber membrane was evaluated. The permeate flux was affected by such parameters as cell concentration, pH, content of antifoam agents, suction pressure, and recirculation rate. A minor effect of temperature on the flux loss was also observed. A microcomputer-aided backflush was proven effective in alleviating membrane fouling and allowing long term separation of P. stipitis from a fermentation broth.

  • PDF

Separation of Cr(VI) from Heavy Metal Salts Mixed Solution by using Hollow Fiber Module (실관막모듈에 의한 중금속염 혼합용액으로부터 Cr(VI) 분리)

  • 최대웅
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.3
    • /
    • pp.107-112
    • /
    • 2001
  • This work reports the application of a hollow fiber module(HFM) for Cr(VI) extraction from heavy metal salts mixed solution by using microporous hydrophobic hollow fiber module. In HFM configuration, the organic extraction used for the extraction of Cr(VI) was di-(2-ethyl hexyl) phosphoric acid(D2EHPA) diluted with n-heptane. The study of HFM includes the influence of hydrodynamic and chemical condition, i.e., the flow rate of feed solution, the time of reactive extraction, the concentration of feed solution, and the pH of aqueous phase solutions. Several experiments with synthetic solution of different mixed components system of Cr(VI) solutions established optimum condition to achieve a clean separation of Cr(VI). It was possible to separate Cr(VI) in the presence of metal salts mixed solution, such as Zn(II), Ni(II), Cu(II), and Cd(II) using the HFM technique.

  • PDF

Removal of toluene using the 2-stage hollow fiber membrane-hybrid reactor (중공사막을 적용한 2단 멤브레인 하이브리드 반응기에 의한 톨루엔 제거)

  • Kim, Jin-Sung;Gu, So-Hee;Kim, Tae-Hyeong;Lee, Myoung-Joo;Hwang, Sun-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.3
    • /
    • pp.287-293
    • /
    • 2010
  • In this study, the toluene gas in VOCs was removed using bioreactor which applied with hollow fiber membrane and Pseudomonas sp. TDB-4. The EBRT of each reactor are controlled 60 sec(R-1) and 30 sec(R-2) and inlet tolune concentration of both R-1 and R-2 is controlled from 25ppm to 500 ppm. Up to 500 ppm of toluene concentration, the toluene removal efficiency of R-1 and R-2 are 92% and 81%, and theirs removal capacities are about 100 g/$m^3$/hr and 180 g/$m^3$/hr, respectively. In addition, according to this study, toluene removal efficiencies at the hollow fiber are approximately 70%(60 sec) and 45%(30sec).

Blood Compatibility of Hollow Fiber Membranes Treated with Plasma Polymerization (플라즈마 중합 처리된 중공사 막의 혈액 적합성)

  • Kwon O. S.;Lee S. C.
    • Korean Journal of Materials Research
    • /
    • v.15 no.8
    • /
    • pp.521-527
    • /
    • 2005
  • Surface modification of polypropylene hollow fiber membranes was peformed in order to develop blood-compatible biomaterials for use in the blood contacting and oxygenation membranes of a lung-assist device(LAD). Blood compatibility was determined by using anticoagulation blood and evaluating formation of blood clots on their surfaces as well as activation of plasma coagulation cascade, platelet adhesion, and aggregation. It was verified that the number of platelets on the silicone coated fibers was significantly lower than those on polypropylene. It was also found that the polypropylene hollow fiber membranes using plasma treatment exhibited suppression of complement activation in blood compatibility test.

Simultaneous Nitrification and Denitrification in a Fluidized Biofilm Reactor with a Hollow Fiber Double Layer Biofilm Media (이중층 중공사 생물막 담체를 이용한 유동층 생물막 반응기에서의 동시 질산화와 탈질)

  • 이수철;이현용;김동진
    • KSBB Journal
    • /
    • v.15 no.5
    • /
    • pp.514-520
    • /
    • 2000
  • Simultaneous nitrification and denitrification of ammonia and organic compounds-containing wastewater were performed in a fluidized bed biofilm reactor with polysulfone(PS) hollow fiber as a double layer biomass carrier. The PS hollow fiber fragment has both aerobic and anoxic environments for the nitrifiaction and denitrification at the shell and lumen-side respectively. The reactor system showed about 80% nitrification efficiency stably throughout the ammonia load conditions applied in the experiment. Denitrification efficiency depended on organic load and C/N ratio. High free ammonia concentration and low dissolved oxygen resulted in nitrite accumulation which leads to enhance organic carbon efficiency in denitrification when compared to nitrate denitrification. The simultaneous nitrification and denitrification reactor system has an economic advantages in reduced chemical cost of organic carbon for denitrification as well as compact reactor configuration.

  • PDF

Moisture Permeation Characteristics of Hollow Fiber Membrane Tube for Humidification According to Input Conditions of Wet Steam (습증기 투입 조건에 따른 가습용 중공사막 튜브 수분 투과 특성)

  • CHAE, JONGMIN;YU, SANGSEOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.6
    • /
    • pp.620-626
    • /
    • 2018
  • Recently, fuel cell field is receiving much attention as an environmentally friendly energy in the world. Among the various types of fuel cells, in the case of PEMFC, ions move through the membrane in the middle of the unit cell. Therefore, proper moisture is required inside the PEMFC. In the case of membrane type humidifier, flat membrane or hollow fiber membrane is mainly used. Since various parameters can change the performance, the performance investigation has to be carried out with parameters. In this study, water transport of hollow fiber membrane was investigated in terms of principle operating conditions such as temperature and flow rate.

Preparation of PVDF Hollow Fiber Membrane via TIPS (Thermally Induced Phase Separation) and Stretching (열유도 상분리와 연신공정을 이용한 PVDF 중공사막의 제조)

  • Park, Minsoo;Kim, Jinho;Jang, Moonseog;Kim, Sung Soo
    • Membrane Journal
    • /
    • v.24 no.2
    • /
    • pp.158-166
    • /
    • 2014
  • In this research, microporous and bicontinuous poly vinylidene fluoride(PVDF) hollow fiber membranes were prepared via hybrid process of the thermally induced phase separation (TIPS) and stretching method. The mechanism of the membrane preparation is based on liquid-liquid phase separation. The final membranes have characteristic structures which have both bicontinuous and fibrillar morphology by applying the stretching method. They showed quite different structure when compared with the spherulitic or nodular structure from S/L TIPS and bicontinuous structure from L/L TIPS. At first, PVDF hollow fiber precursors were prepared via TIPS method using various kind of diluent mixtures. We used gamma-butyrolacton, dimethyl phthalate (DMP), diethyl phthalate (DEP), dibutyl phthalate (DBP) as diluents. We could make hollow fiber membranes which had porous outer surface or dense outer surface by controling the parameters such as cooling conditions, PVDF concentration and the ratio of diluent mixtures. Finally, these hollow fiber were stretched at room temperature and diluents were extracted by ethanol. Effects of the stretching ratio on the membrane morphology were investigated using scanning electron microscope (SEM), and its effects on water flux, porosity, pore size, roughness and tensile strength were examined.